Background High-power short-duration (HPSD) ablation strategy has emerged as a popular approach for treating atrial fibrillation (AF), with shorter ablation time. The utilized Smart Touch Surround Flow (STSF) catheter, with 56 holes around the electrode, lowers electrode-tissue temperature and thrombus risk. Thus, we conducted this prospective, randomized study to investigate if the HPSD strategy with STSF catheter in AF ablation procedures reduces the silent cerebral embolism (SCE) risk compared to the conventional approach with the Smart Touch (ST) catheter. Methods From June 2020 to September 2021, 100 AF patients were randomized 1:1 to the HPSD group using the STSF catheter (power set at 50 W) or the conventional group using the ST catheter (power set at 30 to 35 W). Pulmonary vein isolation was performed in all patients, with additional lesions at operator’s discretion. High-resolution cerebral diffusion-weighted magnetic resonance imaging (hDWI) with slice thickness of 1 mm was performed before and 24–72 h after ablation. The incidence of new periprocedural SCE was defined as the primary outcome. Cognitive performance was assessed using the Montreal Cognitive Assessment (MoCA) test. Results All enrolled AF patients (median age 63, 60% male, 59% paroxysmal AF) underwent successful ablation. Post-procedural hDWI identified 106 lesions in 42 enrolled patients (42%), with 55 lesions in 22 patients (44%) in the HPSD group and 51 lesions in 20 patients (40%) in the conventional group ( p = 0.685). No significant differences were observed between two groups regarding the average number of lesions ( p = 0.751), maximum lesion diameter ( p = 0.405), and total lesion volume per patient ( p = 0.669). Persistent AF and CHA 2 DS 2 -VASc score were identified as SCE determinants during AF ablation procedure by multivariable regression analysis. No significant differences in MoCA scores were observed between patients with SCE and those without, both immediately post-procedure ( p = 0.572) and at the 3-month follow-up ( p = 0.743). Conclusions Involving a small sample size of 100 AF patients, this study reveals a similar incidence of SCE in AF ablation procedures, comparing the HPSD strategy using the STSF catheter to the conventional approach with the ST catheter. Trial registration Clinicaltrials.gov: NCT04408716. Graphical Abstract AF = Atrial fibrillation, DWI = Diffusion-weighted magnetic resonance imaging, HPSD = High-power short-duration, ST = Smart Touch, STSF = Smart Touch Surround Flow.
Left atrial appendage thrombus (LAAT) is a surrogate of thromboembolic events in patients with nonvalvular atrial fibrillation (NVAF). We aimed to investigate the risk factors for LAAT formation before catheter ablation and cardioversion beside the CHA2DS2-VASc score. In this case-control study, patients with NVAF who underwent transesophageal echocardiography (TEE) were included. Demographic data, laboratory results, and echocardiographic measurements were retrospectively collected. Logistic regression analysis was performed to determine risk factors predicting LAAT. Of the 543 included patients, LAAT was identified in 50 patients (9.2%). Multivariable logistic regression analysis for the entire cohort showed that NT-proBNP (per 500 ng/L increase, OR (95% CI): 1.09 (1.00–1.19), p = 0.038) and LDL-C (per 1 mmol/L increase, OR (95% CI): 1.70 (1.05–2.77), p = 0.032) were independently correlated with the presence of LAAT after the adjustment for CHA2DS2-VASc score and anticoagulant therapy. The subgroup analysis of patients without anticoagulant therapy also yielded similar results. Regarding patients with CHA2DS2-VASc scores ≤ 1, a higher level of LDL-C (per 1 mmol/L increase, OR (95% CI): 6.31 (2.38–16.74), p < 0.001) independently correlated with the presence of LAAT. The present study suggests that beyond CHA2DS2-VASc score, raised NT-proBNP and LDL-C are additional predictors for LAAT in NVAF patients.
Intramural or epicardial locations of the arrhythmogenic substrate are regarded as one of the main reasons for radiofrequency (RF) catheter ablation failure. This study aims to conduct a comprehensive analysis of various factors including baseline impedance, irrigant and electrode configuration at similar ablation index (AI) value.
心房颤动传统标准功率射频消融术存在手术时间长、传导恢复率高等缺点。高功率短时程射频消融通过增加阻抗热损伤,减少传导热损伤,同常规功率相比,形成的损伤更宽且略浅,其在显著缩短手术时间、增加损伤连续性的同时,不增加相关并发症的发生率。目前已有多项动物实验及临床研究初步验证了其应用于心房颤动环肺静脉隔离术的有效性及安全性,现对其研究进展进行综述。