Organophosphorus (OP) nerve agents are a group of lethal small molecules. Fieldable detection of nerve agents is an on-going challenge that typically relies on mass spectrometry and infrared spectroscopy but not nuclear magnetic resonance (NMR) spectroscopy because of the portability limitations of superconducting magnets. However, Earth’s field NMR (EFNMR) demonstrates a unique signature space for OP compounds and can be made into a portable detector for OP nerve agents. Here we demonstrate a systematic study to develop the EFNMR signature space of 31 nerve-agent-related OP compounds, including surrogates, simulants, synthetic precursors, decomposition products, pesticides, and threat agents identified by the National Institutes of Health. The EFNMR spectral signatures are a diagnostic fingerprint of the molecular structure, and this study establishes the structure–signature relationships of this relatively unexplored signature space. The results indicate that EFNMR is a powerful analytical capability to distinguish and identify the unique structure of OP compounds, including nerve agents. While aimed at detection of nerve agents, this study also lays the foundations of using EFNMR for detection of any OP compound in the laboratory or in the field.
Los Alamos National Laboratory has a long history of developing and fielding high explosive pulsed power (HEPP) components and systems. In recent years, the Ranchero flux compression generator (FCG or generator) has been modified for improved high current performance, and a new helical flux compression generator (HFCG), the MK-X, has been designed to provide higher initial flux for Ranchero FCGs than can be achieved with the existing capacitor bank at Los Alamos HEPP test facilities. Integrating these two FCGs into a system is the focus of current development, and the first full system test has been performed. The system consists of a MK-X coupled efficiently to an R43S6 FCG with an exploratory pulse forming network (PFN) connecting the FCGs to the load. "R43S6" has become the shorthand designation for a Ranchero module with a 43 cm coaxial section and a Swooped output using a 6 inch diameter coaxial high explosive charge. The goal is to deliver ~50 MA to physics loads on microsecond time scales, and the following material illuminates the design philosophy and summarizes the outcome of the discussions and tests. Analysis of test data is still in progress, and a preliminary synopsis of results is given. Details of our PFN work are given by Gianakon [1] in this conference.
In recent years, it has been realized that low and ultra-low field (mT-nT magnetic field range) nuclear magnetic resonance spectroscopy can be used for molecular structural analysis. However, spectra are often hindered by lengthy acquisition times or require large sample volumes and high concentrations. Here, we report a low field (50 μT) instrument that employs a linear actuator to shuttle samples between a 1 T prepolarization field and a solenoid detector in a laboratory setting. The current experimental setup is benchmarked using water and 13C-methanol with a single scan detection limit of 2 × 1020 spins (3 µl, 55M H2O) and detection limit of 2.9 × 1019 (200 µl, 617 mM 13C-methanol) spins with signal averaging. The system has a dynamic range of >3 orders of magnitude. Investigations of room-temperature relaxation dynamics of 13C-methanol show that sample dilution can be used in lieu of sample heating to acquire spectra with linewidths comparable to high-temperature spectra. These results indicate that the T1 and T2 mechanisms are governed by both the proton exchange rate and the dissolved oxygen in the sample. Finally, a 2D correlation spectroscopy experiment is reported, performed in the strong coupling regime that resolves the multiple resonances associated with the heteronuclear J-coupling. The spectrum was collected using 10 times less sample and in less than half the time from previous reports in the strong coupling limit.
A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed here as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (and the gyromagnetic ratios (gamma) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for gamma was discussed in a previous study. A Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T-2* of samples for an added parameter for more accurate identification of unknown samples.
Nuclear magnetic resonance (NMR) spectroscopy in portable, permanent magnet-based spectrometers is primarily limited to nuclei with higher gyromagnetic ratio, γ, such as 1H, 19F, and 31P due to the limited field strength achievable in these systems. Overhauser effect dynamic nuclear polarization (O-DNP), which transfers polarization from an unpaired electron to a nucleus by saturating an electron paramagnetic resonance transition with an oscillating radio frequency magnetic field, B1e, can increase the polarization of low γ nuclei by hundreds or even thousands, enabling detection in a portable system. We have investigated the potential for O-DNP to enhance signals using (4-amino-2,2,6,6-tetramethylpiperidin-1-yl)oxyl (TEMPO hereafter) as a source of unpaired electrons in a homebuilt ultra-low field (ULF) O-DNP-NMR spectrometer. We have found, in general, that larger concentrations of TEMPO are required for effective O-DNP with low γ nuclei, which has a number of important effects. Spin exchange effects cause the EPR lines to overlap and ultimately merge at high concentrations of TEMPO, fundamentally increasing the maximum possible enhancement, while the electron–electron dipolar interaction reduces both longitudinal and transverse relaxation times for the electrons, dramatically increasing the required B1e strength. The relationship between TEMPO concentration, B1e magnitude and O-DNP enhancement is quantified, and strategies for achieving these fields are discussed.
Using a simple low-field NMR system, we monitored water content in a living tree in a greenhouse over 2 months. By continuously running the system, we observed changes in tree water content on a scale of half an hour. The data showed a diurnal change in water content consistent both with previous NMR and biological observations. Neutron imaging experiments show that our NMR signal is primarily due to water being rapidly transported through the plant, and not to other sources of hydrogen, such as water in cytoplasm, or water in cell walls. After accounting for the role of temperature in the observed NMR signal, we demonstrate a change in the diurnal signal behavior due to simulated drought conditions for the tree. These results illustrate the utility of our system to perform noninvasive measurements of tree water content outside of a temperature controlled environment.
DC745U is a silicone elastomer originally manufactured by Dow Corning under the name of Silastic® DC745U at their manufacturing facility in Kendaville, Indiana. Currently DC745U is available through Xiameter® or Dow Corning’s distributor R. D. Abbott Company. This silicone elastomer is used in numerous parts of weapon systems, including outer pressure pads, aft cap support in W80 and pressure pad in the B61. DC745U is a proprietary formulation and limited information about its composition and properties is provided to the customer. Thus, Los Alamos National Laboratory and Lawrence Livermore National Laboratory have performed a variety of characterization experiments on this material.
Nuclear magnetic resonance (NMR) and magnetic resonance imaging have long been used to study water content in plants. Approaches have been primarily based on systems using large magnetic fields (~1 T) to obtain NMR signals with good signal-to-noise. This is because the NMR signal scales approximately with the magnetic field strength squared. However, there are also limits to this approach in terms of realistic physiological configuration or those imposed by the size and cost of the magnet. Here we have taken a different approach--keeping the magnetic field low to produce a very light and inexpensive system, suitable for bulk water measurements on trees less than 5 cm in diameter, which could easily be duplicated to measure on many trees or from multiple parts of the same tree. Using this system we have shown sensitivity to water content in trees and their cuttings and observed a diurnal signal variation in tree water content in a greenhouse. We also demonstrate that, with calibration and modeling of the thermal polarization, the system is reliable under significant temperature variation.
for sample interrogation over a large range of relevant energies, vastly improving scan times. Our system’s core advantage is a potential breakthrough ability to provide detection discrimination of threat materials by their elemental composition (e.g. water vs. hydrogen peroxide) without opening the container. However, several technical and computational challenges associated with this technique have yet to be addressed. There are several open questions: what is the sensitivity to different materials, what scan times are necessary, what are the sources of background, how do each of these scale as the detector system is made larger, and how can the system be integrated into existing scanning technology to close current detection gaps? In order to prove the applicability of this technology, we will develop a validated model to optimize the design and characterize the uncertainties in the measurement, and then test the system in a real-world scenario. This project seeks to perform R&D and laboratory tests that demonstrate proof of concept (TRL 3) to establishing an integrated system and evaluating its performance (TRL 4) through both laboratory tests and a validated detector model. The validated model will allow us to explore our technology’s benefits to explosive detection in various applications.