Complex structures in living cells and tissues induce wavefront errors when light waves pass through them, and images observed with optical microscopes are undesirably blurred. This problem is especially serious for living plant cells because images are strikingly degraded even within a single cell. Adaptive optics (AO) is expected to be a solution to this problem by correcting such wavefront errors, thus enabling high-resolution imaging. In particular, scene-based AO involves wavefront sensing based on the image correlation between subapertures in a Shack-Hartmann wavefront sensor and thus does not require an intense point light source. However, the complex 3D structures of living cells often cause low correlation between subimages, leading to loss of accuracy in wavefront sensing. This paper proposes a novel method for scene-based sensing using only image correlations between adjacent subapertures. The method can minimize changes between subimages to be correlated and thus prevent inaccuracy in phase estimation. Using an artificial test target mimicking the optical properties of a layer of living plant cells, an imaging performance with a Strehl ratio of approximately 0.5 was confirmed. Upon observation of chloroplast autofluorescence inside living leaf cells of the moss Physcomitrium patens, recovered resolution images were successfully obtained even with complex biological structures. Under bright-field illumination, the proposed method outperformed the conventional method, demonstrating the future potential of this method for label- and damage-free AO microscopy. Several points for improvement in terms of the effect of AO correction are discussed.
Adaptive optics (AO) is a powerful tool for correcting wavefront errors induced by complex structures of biological samples which significantly causes image degradation. A scene-based sensing technique is being popular in microscopic AO systems with Shack-Hartmann (SH) wavefront sensors. A problem in application of the technique is that the shapes of images observed on SAs vary dependently to their positions on the aperture, especially when using microscopic objectives with higher NAs. To mitigate this problem, a differential sensing technique is used that enables measuring image shifts with high correlations over the aperture. Experiments using an artificial testing target including fluorescent beads, which simulates the leaf of moss, were conducted to investigate imaging performances of the present AO system. Unbiased maximum ratios were measured from blurred and AO-corrected images, and then the Strehl ratios were derived from them. Resultant Strehl ratios were around 0.58.
Significance: A scene-based adaptive-optics (AO) system is developed and a method for investigating its imaging performance is proposed. The system enables derivation of Strehl ratios from observed images via collaboration with computer simulations. The resultant Strehl ratios are comparable with those of other current AO systems. Aim: For versatile and noninvasive AO microscopy, a scene-based wavefront-sensing technique working on a Shack-Hartmann wavefront sensor is developed in a modal control system. The purpose of the research is to clarify the imaging performance of the AO system via the derivation of Strehl ratios from observed images toward applications in microscopy of living cells and tissues. Approach: Two imaging metrics that can be directly measured from observed images (i.e., an energy concentration ratio and unbiased maximum ratio) are defined and related to the Strehl ratio via computer simulations. Experiments are conducted using artificial targets to measure the imaging metrics, which are then converted to Strehl ratios. Results: The resultant Strehl ratios are >0.7 and 0.5 in the cases of defocus and higher aberrations, respectively. The half-widths at half-maximum of the AO-corrected bead images are favorably comparable to those of on-focus images under simple defocus aberration, and the AO system works both under bright-field illumination and on fluorescent bead images. Conclusions: The proposed scene-based AO system is expected to work with a Strehl ratio of more than 0.5 when applied to high-resolution live imaging of cells and tissues under bright-field and fluorescence microscopies. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.