BACKGROUND:Pulsed field ablation (PFA) is effective for pulmonary vein isolation (PVI), but phrenic nerve stimulation during applications may induce diaphragmatic contractions and destabilize catheter positioning. This study evaluated whether neuromuscular blockade improves catheter stability. METHODS:Seventy-six patients undergoing PFA under general anesthesia were prospectively enrolled across three centers. Curarization was assessed using train-of-four (TOF). Catheter motion was measured fluoroscopically, including diaphragmatic excursion, lateral displacement, axial entry into the vein, and inadvertent venous intubation. RESULTS:Sixty-five patients (85%) received curare. In right pulmonary veins, catheter and diaphragmatic motion increased progressively with higher TOF. Compared with TOF 0, absence of curare resulted in greater diaphragmatic excursion, increased lateral and axial catheter movement, and more frequent venous intubation (all p < 0.001). Higher TOF (≥ 4) remained an independent predictor of excessive motion. Left-sided veins showed limited motion across TOF levels. CONCLUSION:Inadequate neuromuscular blockade is strongly associated with catheter instability during right-sided PFA. Maintaining TOF ≤ 3 improves stability and may enhance procedural safety. Larger studies are needed to assess long-term impact.
BACKGROUND:Cardiac rhythm irregularities, including atrial fibrillation, atrial premature beats and ventricular premature beats, are the reason for about 33% of electrocardiogram tests performed by general practitioners. Artificial intelligence has shown diagnostic accuracy in electrocardiogram analysis equivalent to that of cardiologists, and single-lead electrocardiograms offer simplified usability. AIMS:To assess the acceptability and utility of a simplified single-lead electrocardiogram device in general practice, integrated with artificial intelligence-based interpretation and a clinical decision support tree derived from artificial intelligence analysis. METHODS:A decision tree based on artificial intelligence-interpreted electrocardiography was developed for managing cardiac irregularities, and validated by expert cardiologists. Between October 2023 and March 2024, a survey was conducted among 1102 general practitioners in France to assess all the study objectives. RESULTS:Of the 221 general practitioners who responded to the survey, 44% owned an electrocardiogram device, and 58% routinely performed electrocardiograms when rhythm irregularities are suspected. Seventy-seven percent believed that a single-lead electrocardiogram device would simplify electrocardiogram use in practice. A key factor for general practitioners that would enhance electrocardiogram use in their practice is publication of official guidelines. Seventy-two percent of general practitioners reported that they would use electrocardiograms more often if artificial intelligence were available for interpretation, and 57% of general practitioners considered artificial intelligence to be a diagnostic aid, rather than a fully autonomous system. The relevance of the decision tree was rated at 8 out of 10. CONCLUSIONS:This general practitioner survey suggests that a single-lead electrocardiogram tool, integrating artificial intelligence-based trace interpretation with a decision tree derived from artificial intelligence analysis, could streamline the management of cardiac rhythm irregularities in general practice. However, its adoption requires the development of guidelines by scientific societies and approval from the national insurance system for reimbursement. Further research is needed to evaluate its feasibility and clinical relevance in real-world settings.
AIMS:There is still conflicting evidence if women with persistent atrial fibrillation (AF) profit from a pulmonary vein isolation (PVI) plus strategy. We evaluated the efficacy of a spatio-temporal dispersion-targeted ablation strategy in women from the TAILORED-AF trial. METHODS AND RESULTS:In TAILORED-AF, 370 patients were randomised to either a personalised, artificial intelligence (AI)-guided tailored ablation or to PVI-only. AF substrate mapping data and 12-month ablation outcomes were compared between women and men. Overall, 21% patients were female (70.4 ± 6.9 vs. 64.5 ± 8.5 years for men, P < 0.001). While spatio-temporal dispersion extent was similar between groups, left atrial low-voltage surface area (<0.2 mV) was significantly larger in women (P < 0.01). In women, the single-procedure freedom from AF (76% vs. 50%, log-rank P < 0.001) and any atrial arrhythmia (56% vs. 38%, log-rank P < 0.05) were significantly superior to PVI alone with a tailored procedure. In the PVI-only group, the single-procedure freedom from AF (50% vs. 70%, log-rank P < 0.001) and any atrial arrhythmia (38% vs. 61%, log-rank P < 0.001) were significantly lower in women. After a tailored ablation, no significant differences were observed between women and men regarding freedom from AF (76% vs. 91%, log-rank P = 0.07) or any atrial arrhythmia (56% vs. 62%, log-rank P = 0.69) free survival. CONCLUSION:Compared to men, PVI-only in women with persistent AF leads to a significantly lower freedom from atrial arrhythmia. A personalised spatio-temporal dispersion-targeted ablation strategy led to a higher rate of freedom from any atrial arrhythmia than standard PVI after a single procedure in women and comparable outcomes between women and men. REGISTRATION IDENTIFICATION:clinicaltrials.gov NCT04702451.
Background:Most data on atrial fibrillation (AF) ablation using the first available pentaspline pulsed field ablation (PFA) catheter (Farapulse, Boston Scientific Inc) come from retrospective center-level registries collected in highly experienced centers. Objective:This study aimed to provide exhaustive and prospective patient-level data on this new ablation modality. Methods:FRANCE-PFA is a nationwide registry (NCT06497933) that included all patients undergoing a first AF ablation using the pentaspline PFA catheter since the introduction of this technology in France. All French centers using this technology participated. Procedural data were prospectively collected at a patient level. Results:This registry included 5223 patients from 33 centers between March 2021 and February 2024 (mean age 65 ± 11 years, 55.4% paroxysmal AF). The procedure duration was 54 ± 23 minutes. Acute pulmonary vein isolation was achieved in 5211 patients (99.8%). The total number of PFA applications was 50 ± 22 with >70 applications in 746 patients (14.3%). Pulmonary vein isolation only was performed in 64.7% of patients (82.7% of paroxysmal AF, 44.5% of persistent AF, and 26.6% of long-standing persistent AF). The most common location for additional PFA lesion sets was the left atrium posterior wall in 1335 patients (25.6%), left atrium roof in 999 patients (19.1%), and mitral isthmus in 514 patients (9.8%). Major complications occurred in 50 patients (0.96%), with no esophageal complication or symptomatic phrenic nerve palsy reported in past hospital discharge. Conclusion:In this prospective and nationwide registry, AF ablation using the pentaspline PFA catheter seemed to be safe and acutely efficient, despite considerable heterogeneity in the number of patients treated at each center. Trial Registration:NCT06497933.
Although pulmonary vein isolation (PVI) has become the cornerstone ablation procedure for atrial fibrillation (AF), the optimal ablation procedure for persistent and long-standing persistent AF remains elusive. Targeting spatio-temporal electrogram dispersion in a tailored procedure has been suggested as a potentially beneficial alternative to a conventional PVI-only procedure. In this multicenter, randomized, controlled, double-blind, superiority trial, patients with drug-refractory persistent AF were randomly assigned to a tailored ablation procedure targeting areas of spatio-temporal dispersion, as detected by an artificial intelligence (AI) algorithm, in addition to PVI (tailored arm, n = 187, 23% women) or to a conventional PVI-only procedure (anatomical arm, n = 183, 19% women). The primary efficacy endpoint was freedom from documented AF with or without antiarrhythmic drugs at 12 months after a single ablation procedure. Secondary endpoints included freedom from any atrial arrhythmic events, and the secondary composite safety endpoint consisted of death, cerebrovascular events, or treatment-related serious adverse events. One year post-procedure, the trial met its primary efficacy endpoint, which was achieved in 88% of patients in the tailored arm compared with 70% of patients in the anatomical arm (log-rank P < 0.0001 for superiority). However, no significant difference between arms was observed for the freedom from any atrial arrhythmia endpoint after one ablation. The safety endpoint did not differ between arms, with procedure and ablation times being twice as long in the tailored arm. These results show that AI-guided ablation of spatio-temporal dispersion areas in addition to PVI is superior to PVI alone in eliminating AF at 1-year follow-up in patients with persistent and long-standing persistent AF. Ablation of subsequent organized atrial tachycardias may be needed to maintain sinus rhythm long term. ClinicalTrials.gov identifier: NCT04702451 .
AIMS:Integrating remote monitoring (RM) into existing healthcare practice for heart failure (HF) patients to improve clinical outcome remains challenging. The ECOST-CRT study compared the clinical outcome of a comprehensive RM scheme including a patient questionnaire capturing signs and symptoms of HF and notifications for HF specific parameters to traditional RM in patients with cardiac resynchronization therapy (CRT) devices. METHODS AND RESULTS:Patients were randomized 1:1 to standard daily RM (notification for technical parameters and ventricular arrhythmias; control group) or comprehensive RM (adding a monthly symptom questionnaire and notifications for biventricular pacing, premature ventricular contraction, atrial arrhythmias; active group). The primary endpoint was all-cause mortality or hospitalization for worsening HF (WHF). Six hundred fifty-two patients (70.4 ± 10.3 years, 73% men, left ventricular ejection fraction 29.1 ± 7.6%, 68% CRT-Defibrillators, 32% CRT-Pacemakers) were enrolled. The COVID-19 pandemic caused an early termination of the study, so the mean follow-up duration was 18 ± 8 months. No statistically significant difference in the primary endpoint was found between the groups [59 (18.3%) control vs. 77 (23.3%) active group; log-rank test P = 0.13]. Among the secondary endpoints, the MLHF questionnaire showed a larger share of patients with improvement of quality of life compared to baseline in the active group (78%) vs. control (61%; P = 0.03). CONCLUSION:The study does not support the notion that comprehensive RM, when compared to standard RM, in HF patients with CRT improves the clinical outcome of all-cause mortality or WHF hospitalizations. However, this study was underpowered due to an early termination and further trials are required. REGISTRATION:Clinical Trials.gov Identifier: NCT03012490.
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for similar to 1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.
Left bundle branch area pacing is an innovative technique employed to maintain left ventricular synchrony. However, the operator can face challenges in penetrating the lead into the septum during screwing. Two pitfalls-helix-only penetration and shallow penetration-hinder lead penetration. The research, conducted in 2 phases on patients and swine hearts, tested 2 techniques to overcome these issues. The results highlight the impact of endocardial involvement and suggest that the optimal technique involves intentionally creating an endocardial breach rather than simply unscrewing and rescrewing. This solution could facilitate the procedure by minimizing the number of attempts to reach the pacing site and thus reducing the risk of complications.
BACKGROUND Among heart failure (HF) patients undergoing cardiac resynchronization therapy (CRT), those with unfavorable electrical characteristics (UEC) are less frequently CRT responders. OBJECTIVES In this study, the authors sought to evaluate the relationship between preprocedural echocardiographic parameters of electromechanical dyssynchrony (EMD) and outcome following CRT. METHODS Among 551 patients receiving CRT, 121 with UEC, defined as atypical left bundle branch, presence of right bundle branch block, or unspecified intraventricular conduction disturbance, were enrolled. Indices of EMD were presence of septal flash, apical rocking, septal deformation patterns, and global wasted work (GWW), determined with the use of speckle-tracking strain echocardiography. Endpoints were response to CRT, defined as a relative decrease in left ventricular end-systolic volume >= 15% at 9-month postoperative follow-up, and all-cause death or HF hospitalization during follow-up. RESULTS Among the 121 patients, 68 (56%) were CRT responders. In multivariate analysis, GWW >= 200 mm Hg% (adjusted odds ratio [aOR]: 4.17 [95% CI: 1.33-14.56]; P = 0.0182) and longitudinal strain septal contraction patterns 1 and 2 (aOR: 10.05 [95% CI: 2.82-43.97]; P < 0.001) were associated with CRT response. During a 46-month follow-up (IQR: 42-55 months), survival free from death or HF hospitalization increased with the number of positive criteria (87% for 2, 59% for 1, and 27% for 0). After adjustment for established predictors of outcome in patients receiving CRT, absence of either of the 2 criteria remained associated with a considerable increased risk of death and/or HF hospitalization (adjusted HR: 4.83 [95% CI: 1.84-12.68]; P = 0.001). CONCLUSIONS In patients with UEC, echocardiographic assessment of EMD may help to select patients who will derive benefit from CRT. (Echocardiography in Cardiac Resynchronization Therapy [Echo-CRT]; NCT02986633) (c) 2023 by the American College of Cardiology Foundation.
In patients with cardiac resynchronization therapy defibrillators (CRT-Ds), the need for implantable cardioverter-defibrillator (ICD) back-up may be questionable at time of CRT-D replacement (REP) if ICD implant criteria are no longer met due to an improved left ventricular ejection fraction (LVEF) and if no major ventricular arrhythmic event (VAE) occurred during the CRT-D lifetime. The aim of our study was to assess the relevance of ICD back-up and predictors of VAE after REP in primary prevention CRT-D patients. The prospective, observational, international BioCONTINUE study investigated the rate of patients with at least 1 sustained VAE (sVAE) post-REP and searched for predictive factors of sVAE. Two hundred seventy-six patients (70 ± 10 years, 77% men, mean LVEF 40.6 ± 12.6%) were followed for 28.4 ± 10.2 months. The rate of patients with sVAE was 8.3%, 10.3%, and 21.2% at 1, 2, and 4 years post-REP. Patients without persistent ICD indication at REP still had a sVAE rate of 5.7% (95% CI 2.3–11.5%) at 2 years. In multivariate analysis, predictive factors of subsequent sVAE were (i) persistent ICD indication (hazard ratio (HR) 3.6; 95% CI 1.6–8.3; p = 0.003); (ii) 64–72 years of age as compared to ≥ 79 years (HR 3.7; 95% CI 1.4–9.7; p = 0.008); and (iii) ischemic heart disease (HR 4.4; 95% CI 2.1–9.3; p < 0.0001). The risk of sVAE (21.2% at 4 years post-REP) depends on age, ischemic heart disease, and ICD indication at the time of REP. A non-trivial risk of sVAE remains in patients without persistent ICD indication. NCT02323503.
Background: Electrocardiogram (ECG) is used to a small extent in general medicine, because of general practitioner (GP) apprehension about interpretation and time consumption. Aim: This study tested the hypothesis that user-friendly EASI ECG improves GP diagnosis of cardiovascular symptoms. Method: Patients over 18 years with recent cardiovascular symptoms or auscultation rhythm abnormalities were included in this prospective, multicentric study (10 practices, 17 GPs). ECG recordings were made with Cardiosecur (R) (4-lead ECG connected to a handheld computer for EASI (TM) processing). Besides clinical data, diagnosis/patient referral were noted before and after ECG and interpretation. GP diagnosis and ECG interpretation were compared with a reference diagnosis made by ECG specialist. Results: There were 338 patients; 66% had cardiovascular risk factors. ECGs were performed for chest pain (41%), auscultation rhythm abnormalities (33%) or palpitations (19%). Average time to perform ECG was 4.7 +/- 2.1 min, with possible home recordings. Compared with standard ECG, improvement provided by Cardiosecur (R) was scored 9/10 (range 7-10) by GPs. GPs correctly interpreted ECG normality/abnormality in 77% of patients. Diagnosis was correctly changed for 14% of patients thanks to the ECG, and wrongly changed for 2%. One new appropriate final diagnosis was achieved for 9 ECG recordings (p < 0.001). Diagnostic certainty increased 1.9 +/- 2.1/10 (p < 0.001). ECG brought about changes in GP decision making: referral or treatment changed for 82 patients (24%) and complementary test for 69 patients (20%). Conclusion: The EASI (TM) algorithm coupled with a handheld computer facilitates ECG recordings in the primary care setting, providing improved diagnosis.
INTRODUCTION:Multiple groups have reported on the usefulness of ablating in atrial regions exhibiting abnormal electrograms during atrial fibrillation (AF). Still, previous studies have suggested that ablation outcomes are highly operator- and center-dependent. This study sought to evaluate a novel machine learning software algorithm named VX1 (Volta Medical), trained to adjudicate multipolar electrogram dispersion. METHODS:This study was a prospective, multicentric, nonrandomized study conducted to assess the feasibility of generating VX1 dispersion maps. In 85 patients, 8 centers, and 17 operators, we compared the acute and long-term outcomes after ablation in regions exhibiting dispersion between primary and satellite centers. We also compared outcomes to a control group in which dispersion-guided ablation was performed visually by trained operators. RESULTS:The study population included 29% of long-standing persistent AF. AF termination occurred in 92% and 83% of the patients in primary and satellite centers, respectively, p = 0.31. The average rate of freedom from documented AF, with or without antiarrhythmic drugs (AADs), was 86% after a single procedure, and 89% after an average of 1.3 procedures per patient (p = 0.4). The rate of freedom from any documented atrial arrhythmia, with or without AADs, was 54% and 73% after a single or an average of 1.3 procedures per patient, respectively (p < 0.001). No statistically significant differences between outcomes of the primary versus satellite centers were observed for one (p = 0.8) or multiple procedures (p = 0.4), or between outcomes of the entire study population versus the control group (p > 0.2). Interestingly, intraprocedural AF termination and type of recurrent arrhythmia (i.e., AF vs. AT) appear to be predictors of the subsequent clinical course. CONCLUSION:VX1, an expertise-based artificial intelligence software solution, allowed for robust center-to-center standardization of acute and long-term ablation outcomes after electrogram-based ablation.
Background: The relationship between myocardial work assessment using pressure-strain loops by echocardiography before cardiac resynchronization therapy (CRT) and response to CRT has been recently revealed. Among myocardial work parameters, the impact of left ventricular myocardial global wasted work (GWW) on response to CRT and outcome following CRT has been seldom studied. Hence, the authors evaluated the relationship between preprocedural GWW and outcome in a large prospective cohort of patients with heart failure (HF) and reduced ejection fraction receiving CRT. Methods: The study included 249 patients with HF. Myocardial work indices including GWW were calculated using speckle-tracking strain two-dimensional echocardiography using pressure-strain loops. End points of the study were (1) response to CRT, defined as left ventricular reverse remodeling and/or absence of hospitalization for HF, and (2) all-cause death during follow-up. Results: Median follow-up duration was 48 months (interquartile range, 43-54 months). Median preoperative GWW was 281 mm Hg% (interquartile range, 184-388 mm Hg%). Preoperative GWW was associated with CRT response (area under the curve, 0.74; P < .0001), and a 200 mm Hg% threshold discriminated CRT non responders from responders with 85% specificity and 50% sensitivity, even after adjustment for known predictors of CRT response (adjusted odds ratio, 4.03; 95% CI, 1.91-8.68; P < .001). After adjustment for established predictors of outcome in patients with HF with reduced ejection fraction receiving CRT, GWW < 200 mm Hg% remained associated with a relative increased risk for all-cause death compared with GWW >= 200 mm Hg% (adjusted hazard ratio, 2.0; 95% CI, 1.1-3.9; P = .0245). Adding GWW to a baseline model including known predictors of outcome in CRT resulted in an improvement of this model (chi(2) to improve 4.85, P = .028). The relationship between GWW and CRT response and outcome was stronger in terms of size effect and statistical significance than for other myocardial work indices. Conclusions: Low preoperative GWW (<200 mm Hg%) is associated with absence of CRT response in CRT candidates and with a relative increased risk for all-cause death. GWW appears to be a promising parameter to improve selection for CRT of patients with HF with reduced ejection fraction.
Abstract Aims We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. Methods and results Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37–97) days. Median daily wear time of WCD was 23.4 (22.2–23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95–0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). Conclusion Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.
BACKGROUND:Despite having an indication for cardiac resynchronization therapy according to current guidelines, patients with heart failure with reduced ejection fraction who receive cardiac resynchronization therapy do not consistently derive benefit from it. AIM:To determine whether unsupervised clustering analysis (phenomapping) can identify distinct phenogroups of patients with differential outcomes among cardiac resynchronization therapy recipients from routine clinical practice. METHODS:We used unsupervised hierarchical cluster analysis of phenotypic data after data reduction (55 clinical, biological and echocardiographic variables) to define new phenogroups among 328 patients with heart failure with reduced ejection fraction from routine clinical practice enrolled before cardiac resynchronization therapy. Clinical outcomes and cardiac resynchronization therapy response rate were studied according to phenogroups. RESULTS:Although all patients met the recommended criteria for cardiac resynchronization therapy implantation, phenomapping analysis classified study participants into four phenogroups that differed distinctively in clinical, biological, electrocardiographic and echocardiographic characteristics and outcomes. Patients from phenogroups 1 and 2 had the most improved outcome in terms of mortality, associated with cardiac resynchronization therapy response rates of 81% and 78%, respectively. In contrast, patients from phenogroups 3 and 4 had cardiac resynchronization therapy response rates of 39% and 59%, respectively, and the worst outcome, with a considerably increased risk of mortality compared with patients from phenogroup 1 (hazard ratio 3.23, 95% confidence interval 1.9-5.5 and hazard ratio 2.49, 95% confidence interval 1.38-4.50, respectively). CONCLUSIONS:Among patients with heart failure with reduced ejection fraction with an indication for cardiac resynchronization therapy from routine clinical practice, phenomapping identifies subgroups of patients with differential clinical, biological and echocardiographic features strongly linked to divergent outcomes and responses to cardiac resynchronization therapy. This approach may help to identify patients who will derive most benefit from cardiac resynchronization therapy in "individualized" clinical practice.
AIMS Pacemaker implantation (PI) after atrioventricular nodal re-entry tachycardia (AVNRT) ablation is a dreadful complication. We aimed to assess periprocedural, early, and late risks for PI. METHODS AND RESULTS All 27 022 patients who underwent latest AVNRT ablation in France from 2009 to 2017, were identified in the nationwide medicalization database. A control group of 305 152 patients hospitalized for arm, leg, or skin injuries with no history of AVNRT or supraventricular tachycardia were selected. After propensity score matching, both groups had mean age of 53 ± 18 years and were predominantly female (64%). During this 9-year period, 822 of 27 022 (3.0%) AVNRT patients underwent PI, with significant higher risk in propensity-matched AVNRT patients compared to propensity-matched controls [2.9% vs. 0.9%; hazard ratio 3.4 (2.9-3.9), P < 0.0001]. This excess risk was significant during all follow-up, including periprocedural (1st month), early (1-6 months), and late (>6 months) risk periods. Annualized late risk per 100 AVNRT patients was 0.2%. In comparison to controls, excess risk was 0.2% in <30-year-old AVNRT patients; 0.7% in 30-50-year-old; 1.1% in 50-70-year-old and 6.5% over 70-year-olds. Risk for PI was also significantly different according to three procedural factors: centres, experience, and ablation date, with a 30% decrease since 2015. CONCLUSION Periprocedural, early, and late risks for PI were higher after AVNRT ablation compared to propensity-matched controls. Longer follow-up is needed as the excess risk seems to persist late after AVNRT ablation.
The ability to visualize the right atrium (RA) by echocardiography allows a quantitative, highly reproducible assessment of the RA volume (RAV). The aim of this study is to evaluate the relation between RAV and long-term mortality in a prospective cohort of heart failure and reduced ejection fraction patients in sinus rhythm receiving cardiac resynchronization therapy. 172 patients were included. The right atrium volume index (RAVI) was calculated using Simpson's method from the apical four-chamber view and indexed to body surface area. The relation between RAVI and mortality during follow up was studied. Median follow up was 68 months (interquartile range 62 to 73 months). Mean RAVI was 27 +/- 14 mL/m(2) (IQR 22 to 33 mL/m(2)). Cumulative 5-year all-cause mortality was 22 +/- 6% in patients with RAVI <= 19 mL/m(2), 24 +/- 6% for RAVI 19 to 29 mL/m(2) and 58 +/- 7% for RAVI >29 mL/m(2) (p for trend <0.001). After adjustment on clinical and echocardiographic predictors of outcome including indices of right ventricular function, there was a significant increase in overall mortality risk with increasing RAVI (adjusted hazard ratio 1.02 [95% confidence interval, 1.00 to 1.03], per 1 mL/m(2) increment; p = 0.042). Patients in the highest tertile (RAVI >29 mL/m(2)) had significantly greater risk of death compared with those with RAVI <= 29 mL/m(2) (adjusted hazard ratio 2.01 [95% confidence interval, 1.15 to 3.50]; p = 0.014). In conclusion, RA enlargement is a powerful and highly reproducible independent predictor of long-term mortality in patients with heart failure and reduced ejection fraction in sinus rhythm receiving cardiac resynchronization therapy. (C) 2018 Elsevier Inc. All rights reserved.
Background: We hypothesized that preoperative electromechanical dyssynchrony amenable to cardiac resynchronization therapy (CRT) and QRS narrowing immediately after CRT are both correlated and have a cumulative impact on response and outcome after CRT. Methods: A total of 233 CRT candidates (heart failure New York Heart Association classes II-IV, ejection fraction < 35%, QRS >= 120 milliseconds, 44% women, 71 +/- 11 years old) were prospectively included. Preoperative electromechanical dyssynchrony amenable to CRT was assessed by septal deformation patterns using speckle tracking echocardiography. QRS narrowing was calculated from 12-lead electrocardiograms before and immediately after CRT implantation. The primary endpoint was overall mortality during long-term follow-up. The NTC clinical trial number is NCT02986633. Results: Eighty-seven percent of patients with preoperative electromechanical dyssynchrony experienced QRS narrowing after CRT (118/ 136), whereas 69% of patients without preoperative electromechanical dyssynchrony (67/97) experienced QRS narrowing after CRT (P < 0.001). By Cox multivariate analysis, both preoperative electromechanical dyssynchrony and lack of postoperative QRS narrowing were independently associated with an increased risk of mortality during follow-up (adjusted hazards ratio [HR] 2.24, 95% confidence interval [CI] 1.43-3.50 and HR 1.90, 95% CI 1.06-3.38, respectively). Compared with patients with preoperative electromechanical dyssynchrony, patients without both electromechanical dyssynchrony and postoperative QRS narrowing experienced a considerable increased risk of mortality during follow-up (adjusted HR 3.70, 95% CI 1.96-6.97). Conclusions: Lack of postoperative QRS narrowing after CRT is associated with preoperative electromechanical dyssynchrony. Both preoperative electromechanical dyssynchrony and postoperative QRS narrowing have a favourable cumulative impact on outcome after CRT.