Cervical laminoplasty is widely used for multilevel cervical stenosis. However, a known complication is C5 palsy, which usually occurs within 1 week postoperatively and is attributed to nerve root traction associated with posterior spinal cord shift. Therefore, we conducted a prospective study to clarify early changes in spinal cord shift within 1 week after cervical laminoplasty. The cohort comprised 51 patients who underwent cervical double-door laminoplasty including the C4/5 level. Spinal cord shift and dural expansion were evaluated on MRI obtained on postoperative day 1 and 1 week postoperatively. A spinal cord shift of ≥ 3 mm at C4/5 was defined as a “great shift,” and contributing factors were analyzed based on demographic and radiographic data. The mean spinal cord shift at C4/5 was 1.4 ± 0.9 mm on postoperative day 1 and 0.6 ± 0.6 mm 1 week postoperatively. The shift was significantly greater on postoperative day 1 than at 1 week from C2/3 to C6/7 (p < 0.001). Six patients exhibited a great shift (mean 3.2 ± 0.3 mm). Multivariate analysis showed that the preoperative anteroposterior diameter of the dura mater at C5/6 was significantly associated with a great shift (OR = 0.46, 95
Background: The use of augmented reality (AR) in orthopaedics is growing rapidly but is mainly limited to pre-operative planning and teaching. This study is one of the first to describe the intraoperative application within revision arthroplasty for the positioning of customised partial pelvic replacements. Methods: In a proof-of-concept study an AR environment was used during surgery in 11 cases to enhance implant positioning. Postoperatively, a voxel-based CT deviation analysis was carried out to determine the COR deviation and the cup plane deviation angle. Additionally, digital implant superimposition was conducted. Results: Implantation was possible in all cases with a mean COR deviation vector of 4.2 (SD 2.5; 1.2-9.3) mm and a cup plane deviation angle of 4.4 (SD 2.5; 0.7-8.1)°. The implant analysis showed a superimposition of 0.69 (SD 0.15; 0.38-0.88) (Dice-Score calculation). Conclusions: This study is able to report promising results for AR in orthopaedic surgery, showing improved intraoperative feedback in complex operations, resulting in increased accuracy. However, the integration of AR poses a new challenge to the surgical team, especially because the AR users are facing a significantly increased level of intraoperative stress. Further development of this auspicious tool, as well as a conceivable combination with navigation, is necessary to facilitate broader usage.
A biopsychosocial assessment of a person with low back pain (LBP) should include the detection of psychological risk factors. Pragmatically, clinicians often use their clinical impression rather than questionnaires to screen for psychological risk factors. This scoping review explores how accurately depression, anxiety, and psychological distress can be identified by musculoskeletal (MSK) or spinal clinicians using clinical impression alone. The study protocol was pre-registered on Open Science Framework (OSF) https://osf.io/pt3a6/ . A comprehensive search strategy using five databases (MEDLINE, CINAHL, Academic Search Complete, APA PsycInfo, APA PsycArticles) was conducted by two independent reviewers, with additional searching of references. Studies must have included adults with LBP, who were assessed by MSK or spinal clinician for depression, anxiety or psychological distress using their clinical impression as well as a reference standard questionnaire. Data were synthesised descriptively and thematically for each psychological factor separately. Eight studies involving MSK clinicians (n = 4) and spinal clinicians (n = 4) were eligible. Four different reference standard questionnaires were used. Overall MSK and spinal clinicians were not accurate at identifying depression, anxiety or psychological distress in adults with LBP using only clinical impression. Mean sensitivity for accurate identification of high reference standard questionnaire scores for depression, anxiety, and psychological distress ranged between 12.0
In high tibial osteotomy (HTO) fixed with a locking compression plate (LCP), overcorrection or undercorrection of knee alignment frequently occurs because the LCP applies not only proximal displacement but also valgus rotation to the distal tibia. We have developed a quantitative technique to precisely fix the tibia with the LCP at the preoperatively planned correction angle in inverted V-shaped HTO. Preoperatively, simulation of the HTO using the LCP is performed with a radiograph, and the distance of the most proximal locking screw from the articular surface is measured. During surgery, a marker wire is precisely inserted into the proximal tibia at the preoperatively planned position of the most proximal locking screw. By inserting the first screw along this marker wire, the LCP is precisely installed on the proximal tibia at the planned position. Then, a compression screw is inserted into the distal tibia through the LCP. This screw pulls the distal tibia toward the distal part of the LCP while applying proximal displacement and valgus rotation. Thus, the tibia is precisely fixed at the planned correction angle.
PURPOSE:Osteoarthritis (OA) of the knee significantly impairs mobility and quality of life. Knee arthroplasties have dramatically improved patient outcomes, allowing individuals to regain independence. Unicompartmental knee arthroplasty (UKA) is a surgical option for patients with isolated single-compartment disease, offering the benefits of reduced surgical time and minimized surgical risks. However, the appropriateness of UKA is often underestimated. Therefore, this study aims to determine the proportion of patients with varus knee OA who are suitable candidates for UKA. METHODS:A prospective cross-sectional study was conducted on 207 knees undergoing knee arthroplasty surgery for varus knee OA. Pre-operative radiographs were graded using both the Kellgren-Lawrence (KL) and modified Keyes classifications. Intra-operatively, the knees were inspected, and photographs of the tibial cut were reviewed by a neutral observer. The appropriateness of UKA was determined based on these evaluations. RESULTS:The lateral compartment was not involved in 169 (81.6%) knees. Only six (2.9%) knees had a KL grade 4 involvement of the lateral compartment. After excluding patients with isolated medial compartment OA, no radiographic evidence of lateral and patellofemoral involvement, and a grade 1 on the modified Keyes classification, we found that 79 (38.2%) patients were suitable candidates for a medial UKA. Intraoperatively, 84 (40.6%) patients had a functional ACL with no observable wear in the lateral and patellofemoral joint (PFJ) compartments. CONCLUSION:In patients with varus knee OA, a significant proportion have wear patterns suitable for management with a UKA. Identifying these patients requires targeted examinations and specific radiographic views.