Wiss, Janney, Elstner Associates, Inc. (WJE) is an American corporation of architects, engineers, and materials scientists specializing in the investigation, analysis, testing, and design of repairs for historic and contemporary buildings and structures. Founded in 1956, WJE is headquartered in Northbrook, Illinois, and has over 600 professionals in twenty offices across the United States. WJE personnel are specialized in architectural, structural, and civil engineering; materials conservation, chemistry and petrography, and testing and instrumentation.
The Getty Conservation Institute, in collaboration with Myanmar's Department of Archaeology and National Museum, initiated a long-term project to develop a holistic and sustainable approach for conserving and managing the Bagan World Heritage Site, a Buddhist cultural landscape encompassing over 3,500 monuments. After the 2016 Chauk earthquake damaged more than four hundred structures, the project prioritized seismic research, structural assessment, repair and retrofitting, conservation of decorated elements, digital documentation, and capacity building. The Repair and Retrofitting of Monuments component classified buildings by structural typology and conducted advanced research and modeling on representative buildings to develop targeted repair and retrofitting strategies. Eleven papers in this special issue present the outcomes of this work, covering typology classification, traditional construction systems, conservation history, seismic hazard modeling, numerical simulations of masonry behavior, digital documentation, 3D modeling, seismic analysis, assessment of nonstructural elements, and standardized post-earthquake damage evaluation. Integrating structural engineering, materials research, and conservation practice, these studies provide a comprehensive knowledge base to guide future interventions and enhance seismic resilience. The project demonstrated the importance of a holistic, research-driven, and collaborative approach to large-scale heritage conservation, offering methodologies and tools applicable to other historic sites facing similar challenges worldwide.
This study focuses on understanding the performance of LC3 at 27 degrees C and 50 degrees C. The roles of two parameters, namely the carbonate source and clinker fineness, were investigated. The effect of carbonate sources on the temperature sensitivity of LC3 was investigated by adding limestone, dolomite, and marble dust to produce blends with commercial cement. Cements with varying fineness were produced in the laboratory by grinding clinker to study the effect of clinker fineness on the temperature sensitivity. The presence of calcined clay inhibits the later-age clinker hydration and strength development in LC3 cured at 50 degrees C. Alternative carbonate sources did not improve the performance of LC3 at higher temperatures. However, the sensitivity of strength development in LC3 to temperature was observed to decrease with clinkers having higher fineness. An increase in the degree of hydration of clinker phases and compressive strength was observed in the LC3 with higher clinker fineness.
The primary parking structure serving O’Hare International Airport was opened for use in 1973 with 10,000 parking spaces and over 240,000 square meters of supported slabs. The six-story concrete structure was primarily reinforced using button-head post-tensioning. A condition assessment was performed in January of 2018 and identified structural deterioration which included freeze-thaw deterioration of concrete, corrosion-related delamination and spalling, and localized eruption of failed button-head tendons. Waterproofing deterioration consisted primarily of wear of waterproofing membranes and damage and wear of expansion joint seals. The resulting multi-year restoration program to extend the service life of the parking structure began in September 2020 and was completed in September 2022. Concrete and post-tensioning repairs to the slab, beams, girders, and columns were performed throughout. Sealant and expansion joint seal replacement were also performed to address leaks. Additionally, a unique structural strengthening repair was implemented at one of the columns that supports a signature helical ramp.
This paper reviews the regulatory and technical framework for inspections of existing structures in the United States of America (USA), focusing on building facades, exterior steel structures, water-tank supports, fire escapes, and bridges. It examines the roles of the IEBC, IBC, ASCE/SEI 11, ACI 562, AISC standards, municipal ordinances, and the National Bridge Inspection Standards. Chicago and New York City facade programs are compared in terms of scope, inspection intervals, reporting, unsafe-condition classification, and required protective measures. Common deterioration mechanisms—corrosion, section loss, cracking, spalling, connection failure, and water damage—are summarized together with inspection methods and the consequences of delayed repairs. The paper emphasizes periodic, risk-based assessment by qualified professionals as essential for public safety, timely maintenance, and rehabilitation.
Static structural health monitoring of masonry and heritage structures typically consists of tracking crack width evolution over time. However, the health evaluation of the current structural condition is not easily relatable to the actual cracks widths. In this paper, crack patterns in masonry walls are related to a stress increase indicator based on data generated through simulations employing accurate block-based numerical models of masonry walls damaged by differential settlements- and earthquake-like scenarios. Such stress increase indicator is defined through a percentile of the static cumulative minimum principal stresses distribution in a damaged wall, so it can be straightforwardly related to the occurrence of crushing failure. Driven by this simulation- generated dataset, a machine learning predictor is trained, validated and tested to provide stress increase indicators in damaged masonry walls by using as only input the crack width distributions of the walls. This allows to originally provide a crack pattern-based real-time damage prognosis tool in static monitoring of cracked masonry walls and structures.