• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Journal of Prosthetic Dentistry

    Journal of Prosthetic Dentistry

    JournalISSN 0022-3913eISSN 1097-6841中科院 医学 3区

    年发文量

    研究主题

    论文(19285)

    排序
    1NewResponse to Letter to the Editor: “minimally Invasive Approach to Hypoplastic Stains with Complementary Color Neutralization: A Clinical Report”
    Bruna Ferreira Lage, Ana Clara M. Barcelos, Amanda S. Silva, João Paulo A. Rocha, Alice M. Barcelos,Ricardo R. Oliveira, Hugo H. Alvim
    2026
    引用
    AI阅读
    加入学术空间
    2NewDigital Technique for Fabricating Complete Dentures with Detachable 3D Printed Cheek Plumper Prostheses Using Integrated Attachments
    Sarthak Singh Tomar,Manu Rathee, Mathiyazhagan Stalin, Senthilvelpalani Balavignesh
    2026
    引用
    AI阅读
    加入学术空间
    3NewInfluence of Patient Head Position and Facial Scanner Viewing Angle on the Accuracy of the True Horizontal Plane Located Using an App-Based Facial Scanner
    Marta Revilla-León,Edgar García-Zea, Juan Carlos Gallardo-Bastidas,Abdul B. Barmak,John C. Kois

    Statement of problem App-based facial scanners capable of automatically generating reference planes, including the true horizontal plane (THP), have been developed to integrate virtual patient representations and transfer them to the virtual articulator. However, the influence of the patient head position and the facial scanner viewing angle on the accuracy of the THP located using an app-based facial scanner remains unknown. Purpose The purpose of this in vivo study was to evaluate the influence of the patient's head position and facial scanner viewing angle on the accuracy of the THP located using an app-based facial scanner (FS) integrated into a smartphone. Material and methods A total of 5 landmarks were placed on the face of a volunteer. Three scans (reference scans) were acquired with an app-based FS (Qlone) integrated into a smartphone (iPhone Pro 17) and an extraoral scan body (Kois Scan Body) capable of registering the THP relative to the natural head position (NHP). Two groups were defined depending on the volunteer’s head position: without (NoNHP group) and with (NHP group) the self-balance and mirror technique to obtain NHP. Two subgroups were created based on the facial scanner viewing angle: at the level (Level subgroup) of or above the interpupillary line (Above subgroup) (n=15). Each reference and experimental scan with the THP generated by the FS was exported. The reference scans were mounted into the virtual articulator (Panadent PCH) by using the THP contained in the extraoral scan body (DentalCAD). Linear measurements were obtained from the landmarks to the auxiliary plane parallel to the articulator’s reference table. Each experimental scan was registered to the reference scan using the landmarks as common points without altering the orientation of the corresponding THP. The THP was then oriented parallel to the sagittal plane of the upper arm of the articulator. Lastly, the same linear measurements were calculated. The average of the linear measurements obtained from the 3 reference scans was used as the reference to calculate distortions for each experimental scan. Two-way ANOVA and Tukey tests were used to analyze trueness. The Levene test was used to analyze precision (α=.05). Results Posterior right plane discrepancies were found between the groups (P<.001) and subgroups (P<.001) with a significant group×subgroup interaction (P=.008). Overall anterior plane discrepancies were revealed between the groups (P<.001) and subgroups (P<.001). Overall posterior left plane discrepancies were found between the groups (P<.001) and subgroups (P<.001), with a significant group×subgroup interaction (P<.001). The NHP group obtained significantly better overall posterior right and anterior and posterior left THP trueness than the NoNHP group. The Same subgroup demonstrated significantly better overall posterior right and anterior and posterior left THP trueness than the Above subgroup. The NoNHP group had better overall posterior right THP precision than the NHP group. The Above subgroup demonstrated better overall posterior right and left THP precision than the Level subgroup. Conclusions The patient head position and facial scanner viewing angle influenced the accuracy of the THP located using the app-based FS tested.

    2026
    引用
    AI阅读
    加入学术空间
    4NewInfluence of Occlusal Plane Inclination and Digital Camera Type on the Accuracy of Maxillary Cast Transfer to a Virtual Articulator
    Marta Revilla-León,Jonathan M. Zeitler,Abdul B. Barmak,John C. Kois

    Statement of problem Two-dimensional (2D) photographs have been described to transfer the maxillary cast to a virtual articulator. However, the influence of occlusal plane inclination and camera type on the accuracy of the maxillary cast transfer remains uncertain. Purpose The purpose of this in vitro study was to assess the influence of the occlusal sagittal plane inclination and camera type on the accuracy of the maxillary cast transfer. Material and methods A dentate maxillary stone cast was mounted in an articulator (Panadent PCH) using the mounting table so that the occlusal plane was horizontal. Fiducial markers were attached to the stone teeth. The cast was digitized with a laboratory scanner (T710). The stone cast was positioned on a calibrated table to control the sagittal tilting of the cast. Twelve groups were created: 0, +1, +2, +3, +4, +5, +6, +7, +8, +10, +12, and +14 degrees. Two subgroups were created: a mirrorless camera (Z8) with a macro lens or a smartphone (iPhone 17 Pro Max) (n=30). In the 0-degree group, the maxillary scan was transferred into the articulator by registering the mounting plate with the mounting platform using a dental program (DentalCAD). A total of 10 linear measurements (3 in the posterior right, 4 in the anterior, and 3 in the posterior left) were obtained between the fiducial markers and an additional plane coincident with the mounting table. The mounted maxillary scan was exported while maintaining the software program’s coordinate system (reference 0-degree scan file). The 0-degree images of mirrorless and smartphone subgroups were then used to transfer the maxillary scan into the same articulator, followed by obtaining the same 10 measurements for each specimen. To obtain the reference mounted scan of the tilted groups, the reference 0-degree scan file was imported into a program (Meshmixer) to tilt the occlusal plane, reproducing the inclinations generated by the calibrated table. In the +1-degree group, the reference +1-degree scan file was imported into the dental program while maintaining the coordinate system, thereby allowing automatic mounting in the articulator. The same 10 linear measurements were obtained for each specimen. In the +2, +3, +4, +5, +6, +7, +8, +10, +12, and +14-degree groups, the same procedures were followed as in the +1-degree group, using the corresponding reference scan file. The measurements obtained in the reference scan files were used as a reference to obtain discrepancies with the maxillary scan transfer for each subgroup specimen in the maxillary plane transfer into the virtual articulator. Trueness was analyzed by using 2-way ANOVA followed by the Tukey tests. Precision was evaluated by using the Levene and pairwise comparisons Wilcoxon rank sum tests (α=.05). Results Significant posterior right and anterior and posterior left trueness discrepancies were found between the groups (P<.001) and subgroups (P<.001), with a significant group×subgroup interaction (P<.001). Overall, the higher the degree of occlusal plane inclination, the higher the posterior right and anterior and posterior left discrepancies. The mirrorless subgroup obtained significantly better posterior right (P<.001) and anterior (P<.001) and posterior left (P<.001) trueness than the smartphone subgroup. The Levene test showed significant posterior right (P<.001) and anterior (P<.001) and posterior left (P<.001) precision discrepancies among the groups and anterior precision discrepancies among the subgroups (P=.024) tested. Conclusions The occlusal plane inclination and the type of digital camera tested influenced the accuracy of the maxillary posterior right and anterior and posterior left plane transfer.

    2026
    引用
    AI阅读
    加入学术空间
    5NewAre There Differences in the Optical Properties of Subtractively and Additively Manufactured Zirconia Restorations? A Systematic Review and Meta-Analysis
    Seyed Ali Mosaddad,Narges Tavahodi, Setareh Hosseinpour,Alexis Ioannidis,Pedro Molinero-Mourelle,Gülce Çakmak

    STATEMENT OF PROBLEM Whether additively manufactured (AM) and subtractively manufactured (SM) zirconia differ in optical behavior under staining and aging remains uncertain. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate differences in color stability (ΔE), translucency (TP), and translucency change (ΔTP) between AM and SM zirconia after aging. MATERIAL AND METHODS An electronic search was conducted across the PubMed, Embase, Scopus, Web of Science, the Cochrane Library, and Google Scholar databases through October 2025. Eligible studies were English-language in vitro investigations directly comparing AM and SM zirconia for ΔE, TP, or ΔTP. The data were pooled using a random-effects model and expressed as weighted mean differences (WMDs) with 95% confidence intervals. Heterogeneity was analyzed using Cochran Q and I² statistics, and publication bias was examined with the Egger test and trim-and-fill correction. Risk of bias was assessed using the RoBDEMAT tool. RESULTS From 4218 records, 5 in vitro studies were included. AM zirconia showed lower ΔE (WMD=-0.226; 95% CI: -0.349 to -0.103; P<.001; I²=97.1%), lower TP (WMD=-4.191; 95% CI: -4.958 to -3.423; P<.001; I²=98.0%), and greater ΔTP after aging (WMD=0.887; 95% CI: 0.091 to 1.683; P=.029; I²=97.0%) compared with SM zirconia. CONCLUSIONS AM zirconia demonstrated less color alteration, lower initial translucency, and higher translucency variation after aging than SM zirconia. However, these optical differences remained within clinically acceptable thresholds.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 19285 篇论文

    高被引作者

    作者引用发文
    Charles J. Goodacre721369
    M. Kern445550
    Brånemark P I41521
    John A Sorensen405531
    Burak Yilmaz4031147
    Kitichai Rungcharassaeng389010
    JYK Kan389010
    William M. Johnston378075
    Steven M. Morgano375359
    Marta Revilla-León3751183

    高产作者

    作者引用发文
    Marta Revilla-León3751183
    Burak Yilmaz4031147
    Stephen F. Rosenstiel251297
    John C Kois136382
    William M. Johnston378075
    Mutlu Özcan340169
    Charles J. Goodacre721369
    Carol Lefebvre4668
    Abdul Basir Barmak114963
    Steven M. Morgano375359

    相关期刊

    Clinical Oral Implants Research
    Dental materials journal
    The International journal of oral & maxillofacial implants
    Journal of Prosthodontic Research
    The journal of advanced prosthodontics
    The Saudi dental journal
    International journal of implant dentistry
    Journal of Dentistry
    Journal of Esthetic and Restorative Dentistry
    Journal of Prosthodontics