• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Journal of Refrigeration

    Journal of Refrigeration

    JournalISSN 0253-4339

    年发文量

    研究主题

    论文(3732)

    排序
    1Flow and Heat Transfer of Nanofluid Microjet Heat Sinks for High-Performance Chip Cooling
    Sun Jian, Mei Yufei, Ye Fan, Li Jie

    The continuous increase in power density of high-performance electronic chips makes thermal management under high heat flux a critical issue to be solved urgently. Microjet impingement cooling offers both high heat transfer intensity and good temperature uniformity, making it a highly promising enhanced cooling solution. In this paper, an array microjet heat sink coupling triangular prism microchannels and hemispherical protrusions is designed. Graphene nanofluids with different mass fractions are prepared by a two-step method, and a closed-loop experimental setup is built. The effects of jet Reynolds number, impingement height, nanofluid concentration and heat flux on the heat transfer and flow characteristics of the heat sink are systematically investigated. The results show that, within the experimental range, 0.10 wt% graphene nanofluid exhibits superior heat transfer performance. Increasing the jet Reynolds number significantly enhances the convective heat transfer coefficient and reduces thermal resistance, but simultaneously increases the pressure drop, resulting in a notable decrease in the energy efficiency ratio. Reducing the impingement height effectively enhances heat transfer, while its impact on flow resistance is relatively small. Within the range of 80-120 W/cm², the heat flux has no significant effect on either the heat transfer coefficient or the pressure drop. The findings provide experimental guidance for the structural design of microjet heat sinks and the optimisation of chip thermal management conditions.

    2026
    引用
    AI阅读
    加入学术空间
    2Review of Thermal Energy Storage Technologies in Low-Carbon Buildings: from Application to Optimization
    Zhao Hengxin, Li Shiying,Wu Yifan,Lin Borong, Hou Wanglan

    SignificanceAgainst the backdrop of global carbon peaking and carbon neutrality goals, the building sector faces an urgent demand for low-carbon transformation. Heating, ventilation, and air-conditioning (HVAC) systems account for more than 60% of the building energy consumption, accompanied by a prominent temporal-spatial mismatch between energy supply and demand. Thermal energy storage (TES) technologies, which allow for the storage and release of thermal energy on demand, represent a pivotal solution to mitigate this mismatch and enhance the energy flexibility of buildings. However, the existing literature mainly focuses on the basic classification and conventional applications of TES while lacking a systematic summary of advanced-performance optimization systems and interdisciplinary innovative application schemes in building scenarios. To fill this research gap, the present study conducted a comprehensive review of the development status, application challenges, and optimization pathways of TES technologies in building applications, thereby providing valuable theoretical references for related research and engineering practices.ProgressThis paper elaborates on the classification and working mechanisms of three mainstream TES technologies: sensible heat storage, latent heat storage, and thermochemical storage. Water-based sensible heat storage is widely deployed owing to its technological maturity and low cost; however, it is constrained by its low energy density and considerable space occupation. Latent heat storage utilizing phase-change materials (PCM) features high energy density and a nearly isothermal charging-discharging process, thus emerging as a research hotspot in building energy storage. Thermochemical storage boasts of ultrahigh energy density and negligible heat loss during long-term storage, although most relevant technologies are still in the laboratory research stage. In terms of application scenarios, this study systematically summarizes the research progress and energy-saving performance of TES technologies from two perspectives: 1) integration with building envelopes and 2) coupling with HVAC systems. For building envelope applications, PCMs are embedded in walls, roofs, and floors to enhance the thermal inertia of the building envelope, dampen indoor temperature fluctuations, and reduce peak cooling and heating loads. For HVAC, TES systems are coupled with HVAC facilities to store thermal energy during off-peak electricity periods and release it during peak demand, thereby delivering notable peak load shifting benefits and economic returns. Furthermore, this study categorizes the performance enhancement approaches into two types: 1) material/structural optimization strategies (including material modification, structural optimization, and heat pipe coupling); 2) external-field strengthening methods (the use of external magnetic, electric, and ultrasonic fields to intensify internal heat transfer). Building upon the authors’ research achievements, two innovative building TES systems are proposed: 1) a new phase-change thermal diode energy storage roof and 2) a mobile cooling energy storage terminal. The roof integrates radiative sky-cooling films, thermal diodes, and PCM layers to achieve seasonal dynamic thermal regulation. The mobile terminal incorporates PCM modules and a convection‒radiation combined cooling structure, enabling targeted near-body cooling for scenarios with sparsely distributed occupants.Conclusion and Prospect TES technologies have demonstrated remarkable application value in building energy conservation and power grid demand response, serving as core enablers for the low-carbon transformation of the building sector. Nevertheless, the large-scale engineering deployment of TES is still hindered by multiple bottlenecks: the intrinsically low thermal conductivity of PCMs restricts the heat charge-discharge rate; the integration adaptability between TES systems and existing building energy systems remains inadequate; and there is a lack of comprehensive evaluation covering full life-cycle economic and environmental benefits. Future research efforts should be directed toward the following: developing high-performance composite PCMs, constructing intelligent TES regulation models integrated with building energy-consumption prediction, and strengthening the interdisciplinary integration of TES technologies with metamaterials and mobile robotics. With continuous material iteration and interdisciplinary integration, building TES technologies are expected to advance toward high efficiency, lightweight design and intelligent operation, providing solid technical support for achieving the carbon goals of the building sector.

    2026
    引用
    AI阅读
    加入学术空间
    3Optimization of Heat Transfer Performance and Economic Analysis for Phase-Change Sleeve-Type Ground Heat Exchanger
    Ding Shumei, Zhu Bairu, Wei Erjian

    A three-dimensional model of a phase-change sleeve-type ground heat exchanger (PCS-GHE) was developed using COMSOL to investigate the effects of a low PCM volume fraction in a phase-change sleeve on the heat transfer performance and construction cost economics. The heat-transfer performance of the PCS-GHE was improved by optimizing the PCM type, volume dosage, and thermal conductivity. The economic feasibility of construction was evaluated based on an engineering case study. The results show that PCM1, namely the CA-LA-metal thermal conductivity-enhancing material, exhibited a relatively high heat transfer performance, making it more suitable as a phase-change interlayer material for the sleeve. At the end of the third day, when the volume dosage of PCM1 increased from 10.73% to 30.60%, the total thermal resistance of the PCS-GHE increased by approximately 19.5%. The unit heat transfer power and backfill soil temperature decreased by approximately 20.3% and 0.85 ℃, respectively. When the thermal conductivity of PCM1 was increased from 0.6 to 1.8 W/(m·K), the thermal resistance of the PCM layer and the total thermal resistance of the PCS-GHE decreased by approximately 66.5% and 38.4%, respectively. The unit heat transfer power increases by approximately 42.6%. An increase in the volume dosage of PCM1 led to a higher construction investment for building cooling. In contrast, an increase in PCM thermal conductivity effectively reduces construction investment. When the PCM thermal conductivity was 1.8 W/(m·K), the construction cost of the PCS-GHE achieved the lowest cost, with the PCM cost and construction investment reduced by 26.3% and 20.5%, respectively.

    2026
    引用
    AI阅读
    加入学术空间
    4Study on Flow and Heat Transfer Performance of Piezoelectric Pump-Driven Microchannel Heat Sink with Fence Pin-Fin Walls
    Chang Rui,Huang Yongping, Zhou Jingjing,Liu Xiangdong,Zhang Chengbin

    ObjectiveWith the rapid increase in the integration level of microsystems, electronic components are continuously developing toward miniaturization, integration and high power, which renders high heat flux density heat dissipation a critical bottleneck restricting the development of high-end electronic devices. Piezoelectric micropumps are regarded as an ideal candidate for lightweight and thin heat dissipation systems owing to their high integration, high power-to-weight ratio and excellent controllability. In this paper, a microchannel heat sink with fence pin-fin walls driven by a piezoelectric pump is proposed. To evaluate the fluid flow and heat dissipation within the heat sink, a three-dimensional numerical modeling was performed, followed by experimental validations. The heat transfer enhancement mechanism of fence pin-fin walls is revealed, and the effects of fin spacing, area fraction and layout region of fence pin-fin walls on the thermal performance of the heat sink are analyzed.MethodsIn this study, numerical simulations of the microchannel heat sink are performed using Fluent software, where a no-slip coupled boundary condition is applied to the fluid-solid interface, mixed boundary conditions are assigned to the top and bottom surfaces of the heat sink, and no-slip adiabatic boundary conditions are adopted for the remaining walls. Grid independence verification is conducted, and the total number of meshes is determined to be approximately 7.56 million. With the Reynolds number of the working fluid ranging from 35~40, the laminar model is adopted for numerical calculation, and the convergence residual criterion is set to 10⁻⁸. Furthermore, experimental tests are implemented to validate the accuracy and reliability of the established numerical model.Results and DiscussionsNumerical results reveal the heat transfer enhancement mechanism of the fence pin-fin walls structure, and clarify the effects of fence pin-fin walls spacing, area fraction and layout region on the thermal performance of microchannel heat sinks. Compared with conventional microchannels with smooth continuous wall, the fence pin-fin walls heat sink with a fin spacing of 0.2 mm reduces pressure drop by 18.87 Pa and increases flow rate by 1.03 mL/h. Such improvements decrease the thermal resistance R by 4.31% and raise the TPF (Thermal performance factor) by 6.45%, indicating that the proposed structure synergistically strengthens flow disturbance and enlarges the heat transfer area. When the fin spacing increases to 1.0 mm, the average Nusselt number Nu¯ and TPF increase by 13.66% and 13.95%, respectively, while R decreases by 1.01%, compared with the 0.2 mm spacing case. Although the convective heat transfer area declines by 3.03% due to the reduced fin number, the average heat transfer coefficient h¯ increases by 13.66%, effectively improving the overall thermal performance. The enhanced convective capacity fully compensates for the performance loss caused by the reduced heat transfer area. At a fixed fin spacing of 0.6 mm, increasing the fence pin-fin walls area fraction from 4.19% to 18.15% reduces thermal resistance stepwise and improves Nu¯ and TPF. Furthermore, the fence pin-fin walls arranged in the heat source coverage region (e1~e3) play a dominate role in heat transfer enhancement and thermal resistance reduction, whereas extending this structure to the non-heat source region (e4~e6) yields lower enhancement benefits.ConclusionsSimulation results indicate that the microchannel heat sink with fence pin-fin walls achieves superior overall thermal performance compared with the smooth continuous wall microchannel heat sink. Appropriately enlarging pin-fin spacing strengthens the convective heat transfer inside channels, and such performance gain can offset the adverse effect arising from the reduction of heat transfer area. Within limited space, the fence pin-fin walls should be preferentially arranged in the core heat source region to fully utilize their advantages in reducing thermal resistance. According to the conclusions of this work, fence pin-fin walls with specific spacing are recommended to replace traditional smooth continuous walls in piezoelectric micropump-driven microchannels under low Reynolds number conditions. Deploying fence pin-fin walls structures preferentially in the heat source coverage region can yield better overall heat transfer performance.

    2026
    引用
    AI阅读
    加入学术空间
    5Field Measurement of Operating Performance and Analysis of Regulation Characteristics of a Multi-Zone Absorption Heat Exchanger Unit
    Duan Haojun,Xie Xiaoyun

    ObjectiveMulti-zone absorption heat exchanger (AHE) units integrate multiple AHE modules sharing a primary water circuit while serving independent secondary heating zones, thereby combining large-temperature-difference heat transfer with zone-specific heating. However, field operating data and an understanding of zone regulation characteristics remain scarce. This study aims to experimentally investigate the operational performance and independent zone regulation capability of dual-zone AHE units in actual district heating projects.MethodsField tests were conducted on two dual-zone AHE units serving two residential districts (Community A and Community B) in a city in Shanxi Province, China, during the 2025-2026 heating season. Both units use lithium bromide-water (LiBr-H2O) solution as the working pair, with design primary network temperatures of 105/20 ℃ and secondary network temperatures of 47/37 ℃. The rated heating capacities are 16 200 kW for Community A (model AHE162) and 10 800 kW for Community B (model AHE108). Temperatures at 18 measurement points covering the inlets and outlets of all generators, condensers, evaporators, absorbers, and plate heat exchangers (PHEs) were continuously recorded at 5-min intervals using temperature loggers with an accuracy of ±0.2 ℃ from January 23 to April 1, 2026. Two flow measurement campaigns were performed using clamp-on ultrasonic flow meters with an accuracy of ±0.5%. The coefficient of performance (COP) of each absorption stage and the overall unit effectiveness were evaluated, and a heat balance check was conducted. A temperature-heat flow (T-Q) diagram was constructed for the Community B unit, and the zone regulation characteristics in terms of temperature and load independence were analyzed.Results and DiscussionsThroughout the test period, the primary supply temperature ranged from 55 to 95 ℃, substantially below the design value of 105 ℃. Nevertheless, both units achieved deep cooling of primary water to 20-25 ℃, while secondary supply temperatures remained stable at 35-42 ℃, satisfying space heating demands. The overall effectiveness values were 1.33 for Community A and 1.36 for Community B, and the COP ranged from 0.6 to 0.8, comparable to reported values for conventional dual-stage AHEs (effectiveness of 1.2-1.43). The heat balance discrepancy was 13.12% for Community B, within the ±15% acceptance threshold, and 23.84% for Community A, which was attributed to large primary water temperature fluctuations during testing. For Community B, the low-zone COP (0.79) was notably higher than the high-zone COP (0.62). This was explained by the smaller log mean temperature difference (LMTD) of the low-zone solution heat exchanger (2.89 K versus 4.77 K), indicating more effective internal heat recovery that brought the dilute solution closer to saturation before entering the generator. The T-Q diagram revealed nearly parallel temperature profiles and small vertical gaps between hot and cold streams in the generator and absorber, indicating uniform heat transfer temperature differences, good thermal matching, and low entransy dissipation. Regarding zone regulation, the mean temperature difference between the high- and low-zone secondary returns was 2.01 ℃, whereas that between the secondary supplies was only 0.36 ℃, demonstrating that the two zones maintained nearly identical supply temperatures despite different return conditions. The zone heat loads could be independently adjusted: at Community A the high- and low-zone heat duties were similar (598 kW versus 589 kW), while at Community B they differed substantially (508 kW versus 852 kW, approximately 68% higher in the low zone), with the low-zone PHE carrying proportionally more primary flow (16.18 t/h versus 5.98 t/h), confirming adaptive load allocation between zones.ConclusionsThe dual-zone AHE units maintained high effectiveness and COP under off-design conditions with primary supply temperatures well below the design value, achieving deep primary cooling comparable to conventional single-zone AHEs while simultaneously satisfying the heating demands of two independent zones. The two zones exhibited independent temperature and load regulation, confirming the feasibility and operational flexibility of multi-zone AHE technology for high-rise building district heating.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 3732 篇论文

    高被引作者

    作者引用发文
    Bingfeng Yu6318
    Q Gao5992
    Xiangzhao Meng5723
    Z. Chen5641
    Guoliang Ding37984
    Jiangping Chen36167
    Fenghao Wang26918
    Ruzhu Wang24051
    Zhihua Wang23914
    Qinbo he2375

    高产作者

    作者引用发文
    Guoliang Ding37984
    Jiangping Chen36167
    Hua Zhang19957
    Ruzhu Wang24051
    Baolin Liu15942
    LeRen Tao21137
    Guangming Chen21137
    Huanxin Chen21136
    Junye Shi11836
    Yitai Ma17235

    相关期刊

    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
    Refrigeration and Air-Conditioning
    Chinese Journal of Power Sources
    Chinese Journal of Refrigeration Technology
    Journal of Engineering for Thermal Energy and Power
    Fluid Machinery
    Cryogenics & Superconductivity
    Journal of Appliance Science & Technology
    热科学与技术
    低温工程