Electronic devices that dissipate high heat flux need compact cooling solutions featuring low thermal resistance and high temperature uniformity. This study proposes a novel hybrid cooling configuration integrating array jet impingement with microchannel heat sinks (MCJHSs) for high-performance electronic thermal management and investigates its flow and thermal performance numerically. The proposed design synergizes the exceptional local convective heat transfer of array jet impingement with a large specific surface area of microchannel structures, while a porous skeleton of 0.15 mm thickness is embedded in the crossflow channel, providing a volumetric enhancement of the heated base. The incorporated porous framework effectively enhances fluid mixing and establishes continuous high-efficiency thermal conduction pathways, thereby delivering a substantially improved overall cooling capacity compared with conventional standalone microchannel and jet impingement cooling schemes. A prototype of the MCJHS was fabricated and tested; the measured outlet velocity and liquid temperature agree well with the simulation results, with the deviations within the respective sensor accuracies, verifying the reliability of the numerical model. On this basis, a comprehensive parametric analysis is performed to systematically quantify the thermal–hydraulic performance of the MCJHS across a wide operational range tailored to electronic cooling scenarios, covering jet velocity, porous filling thickness, and applied heat flux. Key performance metrics, including maximum surface temperature, temperature uniformity, average heat transfer coefficient, and pressure drop, are thoroughly evaluated to elucidate the coupled interaction mechanisms between jet momentum and porous filling thickness. The validated model reveals that the optimal combination of jet velocity and porous filling ratio augments the heat transfer coefficient by approximately 15% and reduces the wall temperature by 18 °C relative to the configuration without the porous skeleton, with the flow resistance remaining within a practically acceptable range. The validated model provides a feasible design strategy and technical reference for the advanced thermal management of next-generation high-power electronic components.
Conductive rollers in Ni-Cr electroplating require wear-resistant surfaces under current-carrying contact. Ag coatings are susceptible to deformation and wear, while the protective response of Ag-Cu coatings under lubricated current-carrying sliding remains insufficiently characterized. In this study, an Ag-Cu coating was prepared on a T2 Cu substrate by rotary spray deposition and evaluated through microstructural characterization, nanoindentation, and sliding tests. Current-carrying friction tests were conducted at 20 N under PAO 10 lubrication for 30 min. The coating exhibited a higher mean hardness (1.943 ± 0.997 GPa vs. 1.055 ± 0.070 GPa) than the substrate. At 20 A, the coating maintained a coefficient of friction of approximately 0.12 and exhibited a wear volume of 2.44 × 10−3 mm3 within the measured region, 19.7% lower than that of the substrate. Morphological and elemental observations were consistent with oxidation and material redistribution. No clear overall advantage was observed at 10 A, whereas severe damage occurred at 30 A despite lower friction. These results indicate a protective benefit at 20 A under the tested conditions and support further evaluation of Ag-Cu coatings for conductive roller protection.
In sliding electrical contact processes, the effects of applied electric current on frictional behavior and surface damage are not aligned, and elucidating the relationship between the two is critical for optimizing the performance of conductive friction pairs in continuous chromium plating systems. In this study, reciprocating friction tests on a self-lubricating copper alloy were performed under varying normal loads (5–20 N) and applied currents (0–5 A), and the frictional response and interfacial evolution of the material were characterized via 3D profilometry, SEM, EDS, and XRD. The results demonstrate that under a 10 N load, the applied current generally reduces the friction coefficient, while the wear-track volume exhibits a non-monotonic trend with current variation. Microstructural analysis reveals that current-carrying friction is accompanied by plastic flow of the Cu matrix, redistribution of carbon-enriched regions, and enhanced surface oxygen signals, reflecting dynamic interfacial evolution under the combined action of mechanical shear and electric current. This work uncovers the asynchronous relationship between current-carrying friction reduction and surface damage evolution, providing experimental evidence for operating condition optimization of sliding conductive materials in continuous chromium plating systems.
Cellulose (FCm) and polypropylene (PPm) fibrous microfiltration membranes with comparable dry-state porosities were compared in terms of wettability, hydration, effective porous structure, and pressure-driven water transport. FCm exhibited substantially greater water uptake than PPm. A parametric volume-balance analysis showed that the inferred hydrated porosity and model-dependent tortuosity of FCm were highly sensitive to the assumed allocation of retained water, preventing the assignment of unique hydrated-state structural values. FCm displayed an approximately Darcy-like pressure–flux response, whereas PPm exhibited nonlinear behavior over 8.5–33.8 kPa, consistent with a pre-Darcy regime. Condensed-tannin (TAM) incorporation was subsequently evaluated as a separate hydroalcoholic membrane-modification process. At a fixed contact time of 120 min and 8.0% (w/v) TAM, incorporation reached 9.90 ± 0.72% for FCm and 8.64 ± 1.64% for PPm. Gompertz analysis showed that operational stabilization depended on membrane type and TAM concentration; thus, 120 min did not represent a universal equilibrium condition. TAM incorporation also increased with temperature and exhibited substrate-dependent pH behavior. Spectroscopic and microscopic analyses supported the deposition of a polyphenolic phase, while aqueous washing revealed partial release of non-crosslinked TAM. Overall, comparable dry-state porosity did not imply equivalent aqueous hydraulic behavior, and TAM incorporation depended additionally on substrate chemistry and processing conditions.
Research into the application of protective beryllide coatings in thermonuclear devices and high-temperature structures is currently of great interest. In thermonuclear devices, beryllides serve as an alternative to pure beryllium. Because beryllides exhibit high corrosion resistance and thermal stability, it was proposed to explore the possibility of using tantalum beryllide as protective coatings for high-temperature structural components. Such structures are used, among other things, in nuclear and thermonuclear facilities. Magnetron tests of tantalum beryllide coatings on stainless steel were conducted under high-temperature oxidation conditions. This article presents new experimental results on the high-temperature corrosion resistance of tantalum beryllide coatings. Coatings subjected to high-temperature oxidation were investigated using gravimetry, RBS analysis, X-ray diffractometry, and high-resolution scanning electron microscopy. The data obtained from the various methods are consistent, enabling a well-founded assessment of the coatings’ durability. It has been determined that, following the tests, the coating thickness decreases by more than a factor of two. A maximum Be diffusion depth of 400 nm into the substrate is achieved at a test temperature of 900 °C. The test results showed relatively low coating resistance under high-temperature oxidation conditions. However, under the test conditions, they contributed to a reduction in corrosion damage to the substrate surface. This makes it possible to classify tantalum beryllide as a promising protective coating for high-temperature materials.