Heavy metal pollution in soil is becoming more and more serious. LIBS is one of the most promising technologies for rapid detection of heavy metal contamination in soil. However, due to the wide variety of soils and complex matrices, accurate quantification remains a challenge. In total, 451 soil samples were prepared and detected by the portable detector of LIBS, which were divided into six categories based on the compactness of the soil pellets, and a separate quantitative model for each type of soil sample was used for quantitative analysis by external standard method. It did not need a lot of data to train the model, and only a small number of calibration samples could be used for quantitative analysis of a large number of samples. The results showed that 78 standard samples and 334 collected samples were quantitatively analyzed by 39 standard samples. Compared with the standard value, the correlation coefficients were all above 0.95. A comparative experiment indicated that the portable LIBS system combined with soil classification and calibration methods can achieve fast and accurate quantitative detection.
沉积物的电子自旋共振测年是利用石英矿物中的顺磁中心浓度确定总辐射能量,进而推定石英矿物的埋藏年代.石英中可用于测年的顺磁中心包括E′心、Al心、Ti心和Ge心.E′心需要经过热活化后才能测年.Al心是一种电子空穴心,在低温下可观测到较强的信号值.光照可以使Al心漂白,但有残留值存在.Ti心、Ge心都是电子中心,Ti心在低温测试中可见,信号微弱.Ge心光晒退最敏感,在常温观测中可见.不同顺磁中心的形成机理不同,导致它们具有不同的特性,适用于不同沉积环境中的样品测年,在冰碛物中Ge心测年更具有可行性.电子自旋共振测试时降低温度可使信号增强,Ti心在10 K和15 K时信号强度最大;Al心在20 K时信号最强;Ge心在200 K时信号明显增强.在电子自旋共振测年中可根据不同顺磁中心信号强度的变化调整测试温度获得信号的最优值.在以后的电子自旋共振(ES R)测试中可以选取信号最强时的测试温度进行测试,以增强微弱信号的信噪比,有利于对复杂的信号形态的分辨确定,提高对信号强度定量的准确性.
蒸发效率和传输效率是影响电热蒸发-电感耦合等离子体质谱(ETV-ICP-MS)技术分析性能的关键因素.综述有关气溶胶传输效率的研究进展,在归纳常用的传输系统评价方法的基础上,重点对影响气溶胶传输效率的电热蒸发装置的改进、蒸发过程的探讨、基体改进剂的选择等研究现状进行评述.有关ETV蒸发过程中基体干扰的作用机制仍有待进一步系统研究,这对于校正策略的优化、新型校正技术的创新与集成具有重要的理论指导意义,可推动ETV-ICP-MS在地质、环境、生物等学科的更广泛应用.
为避免汞消解过程中产生的蒸发损失及前处理过程中产生器具与样品污染,通过配制汞总量为0~2、0~15和25~1 023 ng的三种不同汞浓度系列的标准工作曲线,选取9个土壤样品、3种国家土壤有证标准物质,同一样品分别进行6组平行测定,并抽取3个土壤样品进行3种不同浓度加标回收实验,以对其方法精密度和准确度进行论证,建立了催化裂解-金汞齐富集-冷原子吸收光谱法即直接测汞仪测定土壤样品中汞含量的方法.结果显示,仪器信号值与Hg总量之间均呈良好的线性关系.根据仪器多次测定空白数据结果,按照称样量0.1 g计算,方法检出为0.09 ng/g;平行测定结果相对标准偏差均小于10%,土壤标准物质测定值与参考值均相符,不同浓度的加标回收率范围为69.0%~97.0%.方法可用于批量土壤样品中汞含量的快速测定,精密度和准确度可满足测定要求,且实验过程中无需前处理消解,操作方便、快速高效.
The extracting agent of Mehlich 3 has been used to extract and determine various available nutrients in the soil.However, there are few studies on the influencing factors of this method.We selected two soil samples such as purple soil from Chongqing and aquatic soil from Hebei.Orthogonal test with L 9 (3~4)was designed four factors including the volume of extract solution(A),shaking time(B),shaking temperature(C),and pH of extraction solution(D)were set to study extraction conditions of using the Mehlich 3.The element concentrations of the extract were determined by inductively coupled plasma emission spectrometer(ICP-OES).The results showed the amount of soil available nutrients increased with increasing pH of the extract solution.oscillation temperature had less influence on the content of soil nutrients.Considering the economic benefits and significance, it is suggested that the optimal conditions for extracting soil nutrients by Mehlich 3 were A1B1C1D1.A portion of 5.00 g of the air-dried soil samples was added with 25.0 mL of Mehlich 3 extraction solution with a pH of 2.5,which was shaken at 20 ℃ for 5 min.Under optimal conditions, the relative standard deviation of elements is between 0.39% and 4.2%,with good precision except for the B element.The method is green, low-cost, practical, and suitable for the determination of soil nutrient content.