• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    IEEE International Ultrasonics Symposium : [proceedings]

    IEEE International Ultrasonics Symposium : [proceedings]

    ConferenceISSN 1948-5719

    年发文量

    研究主题

    论文(8774)

    排序
    1Human Mole Contrast-Free Microvascular Imaging Using Erythrocytes
    Ali Salari, Rikke Baarts, Mostafa Amin Naji,Borislav Gueorguiev Tomov,Michael Bachmann Nielsen,Jorgen Arendt Jensen

    SUper-Resolution ultrasound imaging using Erythrocytes (SURE) creates microvascular images without any contrast agent injection, with only a few seconds of acquisition time. This paper hypothesizes that it is possible to reveal the microvascular density and velocity estimation of a human mole without the use of contrast agents, with just two seconds of data acquisition. In this study, imaging results from a single volunteer are presented. The SURE density image obtained using a Verasonics research scanner is compared with the Power Doppler image acquired from a commercial GE LOGIQ E9 scanner. The SURE tracking pipeline successfully visualized and estimated the velocity map and velocity profile of vessels as small as 65 mu m in diameter, with flow velocities as low as 3.2 mm/s. It shows the feasibility of visualizing the vasculature of benign moles, which potentially can assist medical doctors in distinguishing between benign and malignant moles and prioritizing them for further investigation.

    2025
    引用
    AI阅读
    加入学术空间
    2A Method for Advanced Testing of Bone Implant Materials with Acoustic Emission (AE)
    Kianusch Pour Rahimi, Ute Urban, Fabian Mueller, Patrik Mueller, Roland Lachmayer, Ulrich P. Froriep

    Osseointegration is the main criterion for implantation success and remains a major challenge during implant development and patient treatment. Since conventional testing does not allow for accurate identification of implant loosening, we developed a new test stand where acoustic emission analysis is applied to the push-out testing process. This allows for more accurate data on implant loosening with similar loading conditions. This study investigates the interaction of mechanical behavior and acoustic emission (AE) characteristics of pork bone and sawbone samples during a combined push-out test. The primary aim is to analyze the AE data and correlate acoustic parameters. Therefore, 11 bone-implant samples of each material have been tested in a push-out process and analyzed with regards to the AE parameters. We conclude that identification of fracture types - shear or tensile - via rise angle and average frequency is a crucial step in the early detection of implant loosening. Although sawbone samples provide high reproducibility, they do not perfectly mimic natural bone, and animal bone offers more realistic results. Therefore, the proposed testing method is a promising tool for more accurate evaluation of bone-implant interactions in future osseointegrated samples.

    2025
    引用
    AI阅读
    加入学术空间
    3A High-sensitivity CMUT for Underwater Sensing Application
    Chi Zhang, Wenle Ye,Pengfei Niu,Zhuochen Wang,Hui Zhang

    Capacitive micromachined ultrasonic transducers (CMUTs) feature small size, wide bandwidth and good matching with acoustic impedance of water. The application of CMUTs in underwater sensing systems has the potential to reduce power consumption and save space. However, compared to traditional piezoelectric transducer, CMUTs exhibit lower sensitivity. To address this issue, this study designed a high-sensitivity CMUT device by reducing the silicon membrane thickness and optimizing the thickness of package material, and then characterized its acoustic performance. The results indicate that the CMUT exhibits significant advantages in terms of transmit sensitivity and bandwidth, and holds potential for applications in underwater sensing systems.

    2025
    引用
    AI阅读
    加入学术空间
    4Four-dimensional Optical Coherence Elastography (OCE) for Assessing Cutaneous Leishmaniasis Lesions and Treatment Response in Murine Model
    Yilong Zhang, Tianyu Zhang,Katrien Van Bocxlaer, Zhengshuyi Feng,Chunhui Li, Zhihong Huang

    Cutaneous leishmaniasis (CL) is the most common form of leishmaniasis, manifesting as skin lesions that can lead to scarring and may have lifelong impacts on wellbeing. Early and accurate assessment of lesion biomechanics could enhance diagnosis and therapeutic monitoring. In this study, we evaluate the feasibility of four-dimensional (4D) dynamic optical coherence elastography (OCE) for in vivo characterization of CL lesions in murine model. Four mice at distinct disease stages: healthy baseline, day 1 post-infection, developed lesion, and post-treatment, were scanned. Volumetric elasticity values were obtained by calculating local elastic wave velocities. Healthy skin exhibited uniform wave propagation with an average Young's modulus of 19 +/- 2 kPa, and a similar value was observed at day 1 post-infection (20 +/- 5 kPa). In contrast, developed lesions displayed markedly increased stiffness (511 +/- 238 kPa), which decreased following treatment (68 +/- 27 kPa). These findings demonstrate that 4D dynamic OCE can quantitatively and non-invasively detect biomechanical changes associated with CL progression and treatment response, supporting its potential as a diagnostic and monitoring tool in clinical settings.

    2025
    引用
    AI阅读
    加入学术空间
    5Magnetic Ultrasound Catheter with Forward- and Side-Looking Imaging Modes
    Zhengxin Yang, Lihao Liu,Zhangjian Li, Haili Yu,Ninghao Wang, Yaocao Cui,Yang Jiao

    Intravascular ultrasound (IVUS) serves as an important imaging technique for the diagnosis of cardiovascular diseases (CVDs). Commercial IVUS catheters use either a side-looking rotating transducer or a circumferential transducer array to provide cross-sectional ultrasound (US) images. However, it cannot visualize the path ahead of the catheter, which is necessary for applications such as chronic total occlusion (CTO) angioplasty. This study proposes a concept dual-mode magnetic US catheter, mainly consisting of a magnetic component and two miniature high-frequency US transducers, which can perform both forward-looking sectorial scanning and side-looking circular scanning B-mode US imaging by remote magnetic actuation. The fabricated prototype catheter has an outer diameter of 1.8 mm. The center frequencies of the two transducers are both 30 MHz. Preliminary experiments are conducted to validate the effectiveness.

    2025
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 8774 篇论文

    高被引作者

    作者引用发文
    Jørgen Arendt Jensen1559155
    Elisa E. Konofagou90379
    Herve Liebgott81981
    Tanter Mickael81848
    Hashimoto Kenya81784
    Lasse Løvstakken79161
    Matthew W. Urban72867
    Paul Dayton69167
    Shigao Chen67644
    Mark L. Palmeri62772

    高产作者

    作者引用发文
    Jørgen Arendt Jensen1559155
    Piero Tortoli582119
    Alessandro Ovidio Paris Ramalli47595
    Steven Freear33986
    Hashimoto Kenya81784
    Nico De Jong49682
    Herve Liebgott81981
    Georg Schmitz48980
    Elisa E. Konofagou90379
    Caterina Gallippi27877

    相关期刊

    IEEE Transactions on Biomedical Circuits and Systems
    Biomedical Circuits and Systems Conference
    Proceedings of IEEE Sensors
    Proceedings. IEEE International Conference on Micro Electro Mechanical Systems
    IEEE sensors letters
    IEEE Transactions on Biomedical Engineering
    IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
    Internaltional Ultrasonics Symposium
    IEEE Sensors
    IEEE JOURNAL of ELECTROMAGNETICS RF and MICROWAVES in MEDICinE and BIOLOGY