BACKGROUND:Total knee arthroplasty (TKA) offers significant relief for advanced knee osteoarthritis. With an aging population, TKA procedures are increasing, leading to a higher demand for revision surgeries. Rotating-hinge knee (RHK) prostheses have emerged as a solution for complex revisions, but the long-term durability of RHK prostheses and their effectiveness in infection-related revisions remain controversial. Therefore, this study aimed to evaluate the mid- to long-term clinical and survivorship outcomes of a single-design rotating hinge knee (SDRHK) system in revision TKA, comparing patients revised for infection with those revised for noninfectious causes. METHODS:This retrospective study analyzed 110 patients who underwent revision total knee arthroplasty (rTKA) with a SDRHK system from 2004 to 2023, with an average follow-up of 11.3 years. Patients were divided into an infection group (n = 51) and a noninfection group (n = 59) for comparative analysis. Preoperative diagnostic arthrocentesis was performed to evaluate synovial cell count, leukocyte differential, and microorganisms. Functional outcomes were assessed using Hospital for Special Surgery (HSS) knee score, range of motion (ROM), and Knee Society Score (KSS). Study outcomes included prosthesis survival, mechanical failure, and complications. Data were analyzed using Kaplan-Meier survival analysis, t test, and χ 2 test, with statistical significance set at p ≤ 0.05. RESULT:The infection group experienced symptom onset significantly earlier than the noninfection group (18.8 vs. 50 months, p = 0.003), had a shorter initial prosthesis lifespan (32.7 vs. 66.8 months, p = 0.001), and underwent more surgeries before revision (2.6 vs. 1.6, p = 0.004). Microbiological analysis indicated that coagulase-negative staphylococci and Staphylococcus aureus were the most commonly isolated pathogens. The 5- and 10-year prosthesis survival rates in the infection group were 78.4% and 71%, respectively, while those in the noninfection group were 83.1% and 74.6%. At the latest follow-up, survival rates for the two groups were 68.6% and 71.2%, showing similar outcomes. Functional scores in both groups improved postoperatively, with no significant differences in HSS, ROM, or KSS scores between the groups. CONCLUSION:This study highlights the important value of RHK prostheses in the treatment of prosthetic joint infection (PJI) after TKA. Despite challenges such as earlier symptom onset, shorter prosthesis lifespan, and higher complication rates in the infection group, their functional outcomes and prosthesis survival rates were comparable to those of the noninfection group, further validating the effectiveness of RHK prostheses. These findings provide useful references for clinical management of PJI and underscore the importance of continued innovation in revision techniques.
This study reports the mid-term outcomes of primary total hip arthroplasty (THA) and investigates the effect of bony ankylosis on postoperative hip function in patients with ankylosing spondylitis (AS). We identified 544 primary THAs performed in 319 consecutive patients with AS (median age, 33 years) from 2012 to 2017. Survivorship of the implants, complications, and patient satisfaction were investigated. Functional outcomes were assessed by the measurement of hip flexion–extension range of motion (ROM), the Harris hip score (HHS), and the Western Ontario and McMaster Universities Arthritis Index (WOMAC). The hips undergoing THA were divided into a bony ankylosis group and a hip stiffness group based on the severity of hip involvement. The postoperative functional results of the two groups at the most recent follow-up were compared. Survivorship was 99.8
Aims:The position of the centre of rotation (COR) for the best function and recovery of gait after total hip arthroplasty (THA) in patients with Hartofilakidis type B developmental dysplasia of the hip (DDH) remains controversial. This study aimed to compare the functional outcomes between two methods of reconstruction and quantify the optimal COR for the recovery of gait. Methods:Out of 1,359 THAs which were identified, 223 patients (223 hips) with unilateral Hartofilakidis type B DDH and a normal contralateral hip who underwent anatomical mirroring reconstruction using autografts (Group A, 115 hips) or high hip centre (HHC) reconstruction (Group H, 108 hips) between January 2011 and June 2021 were reviewed. Functional and radiological results, including patient-reported outcome measures (PROMs), the height of the COR and offset, and recovery of gait, were compared between the groups. Factors associated with a limp were identified by Cox regression analysis and used to develop a nomogram. A power analysis indicated that 54 patients were required to detect a 25% difference in recovery of gait (α = 0.05, power = 0.80). Results:During mean lengths of follow-up of 9.09 years (SD 3.21) and 8.62 years (SD 2.74) in Groups A and H, respectively, the Harris and Oxford Hip Scores significantly improved in both groups, with significantly better improvements in Group A than in Group H (both p < 0.001). Significantly more patients in Group A achieved recovery of gait than in Group H (103 (89.6%) vs 72 (66.7%); p < 0.001) at final follow-up. Early recovery of gait was significantly more likely in patients with smaller differences in COR height bilaterally (p < 0.001), younger patients (p = 0.021), and those who had not previously undergone a shelf acetabuloplasty (p < 0.001). The nomogram showed good performance (area under the receiver operating characteristic curve = 83.9%). Conclusion:Significant functional improvement, with the COR placed < 1.18 cm above the normal contralateral hip, was achieved in both groups, but mirroring reconstruction provided earlier and better recovery of gait. We recommend that surgeons use this nomogram to assess the odds of there remaining a limp postoperatively before undertaking THA, in order to improve expectations and rehabilitation.
Purposes Due to the morphological diversity of deformities, technical difficulties, improperly designed components, and so on, THA remains a challenging task in dysplastic hips, especially in highly dislocated hips. The purpose of this study was to comprehensively evaluate the clinical outcomes of robot-assisted THA in patients with DDH through a large cohort study, including the precision of acetabular cup positioning, indicators of inflammatory response, indicators of muscle damage, and complications. Methods We retrospectively analyzed patients with DDH who underwent THA in our prospectively constructed joint registry between August 2018 and August 2022. Finally, 147 manual THAs and 147 robotic-assisted THAs were included in the final analysis. Patient demographics, indicators of inflammation, indicators of muscle damage, operative time, Harris hip scores (HHS), and forgotten joint score (FJS) were recorded for analysis. The precision of the positioning of the acetabular component was assessed with plain radiographs. Results In the Crowe II/III groups, the reconstructed center of rotation (COR) in the robotic-assisted group was closer to the anatomical COR with less variation than the manual group (absolute horizontal distances of COR 3.5 ± 2.8 vs. 5.4 ± 4.9 mm, p < 0.05; absolute vertical distances of COR 6.4 ± 4.1 vs. 11.7 ± 8.2 mm, p = 0.001). For all Crowe subtypes, the robotic-assisted THA significantly increased the proportion of acetabular cups located in the safety zone within 5° (all p < 0.05). Interleukin-6 and creatine kinase levels were slightly lower and significantly different in the robotic-assisted group at three days postoperatively (all p < 0.05). Conclusions Compared to the manual technique, the robot-assisted technique improved the precision and reproducibility of acetabular component positioning, particularly in DDH patients with Crowe types II/III. The robotic-assisted technique did not increase operative time, bleeding, complications, or revision rates, and had a slighter early inflammatory response and muscle damage.
ObjectiveBoth porous metal cones and metaphyseal sleeves are excellent implants for reconstructing severe bone defects in the knee joint, but they both exhibit design limitations. The porous metal cone, especially, has significant room for improvement in its shape design. The existing porous metal cones often feature a conical external surface with a relatively small taper, potentially compromising both rotational and axial stability. To improve both axial and rotational stability in porous metal cones, we developed a 3D‐printed stepped porous metal cone. This study aimed to assess the short‐term clinical outcome of the 3D‐printed stepped porous metal cone and to compare it with the clinical outcome of patients who underwent revision total knee arthroplasty (rTKA) with the metaphyseal sleeves during the same period.MethodPatients who underwent total knee arthroplasty revision with metaphyseal bone defect reconstruction from 2019 to 2021 were retrospectively analyzed. A total of 61 patients were enrolled in the study, including 15 patients using 3D‐printed stepped porous metal cones and 46 patients using metaphyseal metal sleeves. Thirty patients using metaphyseal sleeves were screened by propensity score matching method and compared with those using stepped cones. Analysis included the American Knee Society Score, the Hospital for Special Surgery knee score, the Western Ontario and McMaster Universities Arthritis index, the Short Form 12 (SF‐12) health survey, and radiographic assessment with a mean follow‐up of 28.5 ± 8.3 months. To conduct comparative analyses, unpaired Student's t‐tests were employed for continuous variables, while categorical variables were analyzed using the appropriate Fisher exact or chi‐squared test.ResultsIn this study, the survival rates of both the stepped cone and metaphyseal sleeve were 100%. There was no statistically significant difference in postoperative knee function scores between the two groups (p > 0.05). However, patients in the cone group had significantly higher mental component summary scores on the SF‐12 scale (p < 0.05) and higher increases in mean postoperative physical component summary scores than patients in the sleeve group (p < 0.05). In addition, patients in the cone group experienced fewer intraoperative and postoperative complications compared to the sleeve group.ConclusionThe 3D‐printed stepped porous metal cone can effectively reconstruct bone defects in complex rTKA and provide satisfactory early clinical and radiographic results. The 3D‐printed stepped cone provides a more stable structure similar to the sleeve while maintaining the original benefits of the cone making it a promising choice for rTKA.
This study aimed to report the mid-term functional outcomes of total hip arthroplasty (THA) for the treatment of advanced hip involvement in ankylosing spondylitis (AS) and identify the factors associated with poor hip flexion range of motion (ROM) after THA in patients with AS. We retrospectively investigated the mid-term functional outcomes in 313 AS patients (538 hips) who underwent primary THA from 2012 to 2017, with a mean follow-up of 7 years (range, 4–9 years). Postoperative functional outcomes were assessed by hip flexion ROM, Harris hip score (HHS), and the Western Ontario and McMaster Universities Arthritis Index (WOMAC). The hips were divided into poor (≤ 90°) and good hip flexion ROM (> 90°) groups based on the degree of hip flexion ROM recorded at the most recent follow-up. We grouped factors related to postoperative hip flexion ROM into three categories: preoperative (or patient-related), intraoperative (or surgery-related), and postoperative factors. Multivariate logistic regression was performed to identify the independent factors associated with postoperative poor hip flexion ROM. The overall flexion-extension ROM improved significantly with a median from 0° (0 120°) to 100° (30 130°) after THA (P < 0.001), and the mean HHS increased from 37 to 90 (P < 0.001). There were 102 hips (19
Background: There are limited long-term results of using ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) in a large number of patient cohorts. The purpose of this study was to evaluate the minimum 10-year clinical and radiological outcomes and survivorship in a single surgeon series of CoC-THA.Methods: Among the 1,039 patients (1,391 hips) who underwent primary THA at our institution between 2008 and 2011, 49 patients (69 hips) experienced paralysis or death, and 194 patients (239 hips, 19%) were lost to follow-up. The remaining 796 patients (1,083 hips) were assessed at a mean of 11 years (range, 10 to 13 years) using the modified Harris hip score (mHHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a questionnaire on articular noises. Survival analysis was used to estimate the survivorship. Radiological evaluation was performed on 869 hips at the final follow-up.Results: Survivorship at 11 years was 98.3% for revision or aseptic loosening, and 98.2% for reoperation. At the final follow-up, the mean mHHS and WOMAC scores were 93 (range, 12 to 100) and 14.4 (range, 3 to 66), respectively. There were 131 (12%) hips that experienced squeaking, but no patient required revision. No fracture of the ceramic was observed. Radiological evaluation at the final follow-up revealed that 3 (0.3%) hips exhibited loosening, 2 (0.2%) had femoral osteolysis, 81(9.3%) acquired radiolucencies, and 35 (4%) showed heterotopic ossification.Conclusion: This CoC bearing for THA had a high survivorship and excellent functional outcomes for at least 10 years.& COPY; 2022 Published by Elsevier Inc.
Objective Management of bone loss in complex primary and revision total knee arthroplasty is key to the surgeries. Metaphyseal metal sleeves have been increasingly used recently to reconstruct severe knee metaphyseal bone defects. This study aimed to investigate the outcomes of the metaphyseal sleeve reconstructing Anderson Orthopedic Research Institute (AORI) type II and type III bone defects of knee joint. Methods From 2014 to 2019, a total of 44 knees were enrolled in this clinical retrospective study after the screening, including seven cases of primary TKA and 37 cases of revision TKA. The types of bone defects involved in this study were AORI types II and III, and did not involve AORI type I bone defects. Patients' knee function preoperatively and postoperatively as well as quality of life were recorded and analyzed. Analysis included the American Knee Society Score (KSS), hospital for special surgery knee score (HSS), the Western Ontario and McMaster Universities (WOMAC) index, the Short Form 12 (SF‐12) health survey, visual analogue scale score, and radiographic assessment with a mean follow‐up of 6.4 years. Paired t‐tests were used to determine the significance of changes in clinical scores and knee mobility. Results A mean follow‐up of 77.2 (±17.6, standard deviation [SD]) months was performed, and none of the patients underwent knee revision for infection or aseptic loosening. At the last follow‐up, the KSS knee score changed statistically from 37.1 (±19.7) preoperatively to 86.5 (±13.6, SD, p < 0.001) postoperatively and the KSS function score from 32.7 (±24.0) preoperatively to 78.3 (±15.6, SD, p < 0.001) postoperatively. The knee mobility improved from a mean of preoperative 72.61° (±33.42°, SD) to 108.52° (±24.15°, SD, p < 0.001). Postoperative radiographs showed that the host bone was tightly integrated with the metaphyseal metal sleeve, and there was no obvious translucent line formation around the sleeve. Of the patients, 86.4% had a postoperative satisfaction score ≥8 (10‐point scale). Conclusion At the mean follow‐up of 6.4 years, the survival rate of the metaphyseal sleeves was 100%. Metaphyseal sleeves combined with cementless stems is an excellent and viable option for reconstruction of AORI type II and type III bone defects of the knee.
Purpose:The aim of this study was to retrospectively analyze 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/ computed tomography (CT) images of non-infected hip arthroplasty patients and summarize findings that may be useful for clinical practice.Methods:18F-FDG PET/CT images of non-infected hip arthroplasty patients were collected from September 2009 to August 2021. The region of interest was independently delineated by two physicians and maximum standardized uptake values (SUVmax) were recorded and compared. Serologic data were also collected and the correlation between SUVmax and serologic parameters was analyzed, while the images were classified based on the 18F-FDG uptake pattern in the images using the diagnostic criteria proposed by Reinartz et al. (9). The interval between hip replacement and PET/CT was classified by year and the characteristics of the two groups were compared. The images of patients who underwent PET/CT multiple times were analyzed dynamically.Results:A total of 121 examinations were included; six patients underwent PET/CT twice and two patients had three scans. There were no significant correlations between SUVmax and serologic results. The interobserver agreement between the two physicians in the classification according to the criteria of Reinartz et al. (9) was 0.957 (P < 0.005). Although there was non-specific uptake in cases with an arthroplasty-to-PET/CT interval this was non-significant. Additionally, 18F-FDG showed potential utility for dynamic observation of the condition of the hip.Conclusion:SUVmax provided information independent of serologic results, meanwhile 18F-FDG showed potential applicability to the dynamic monitoring of hip arthroplasty-related diseases. However, the presence of blood vessels and muscles affected image interpretation and the specificity of 18F-FDG was not optimal. A more specific radionuclide is needed to maximize the benefits of using PET/CT for the assessment of periprosthetic joint infection (PJI).
BACKGROUND: Periprosthetic joint infection (PJI) is one of the worst complications following total joint arthroplasty (TJA). Unfortunately, effective prevention strategies to reduce the burden of PJI have not been fully determined in hip replacement patients with fracture and non-fracture. OBJECTIVE: This study aimed to analyze and compare the demographic characteristics, microbiological profiles and antibiotic resistance of PJI after hip replacement between patients with fracture and non-fracture. METHODS: We retrospectively analyzed the data of 132 patients who treated PJI. There were divided into two groups: non-fracture group (64 patients infected after hip replacement for fracture) and non-fracture group (68 patients infected after hip replacement for non-fracture). Microorganisms were obtained from the synovial fluid and infected necrotic tissue in the joint capsule, medullary cavity, or acetabulum in all patients, and microbiological profiles and antibiotic resistance were evaluated. RESULTS: Coagulase-negative staphylococci (CoNS) were the most common pathogenic microorganisms in all patients. Methicillin-resistant Staphylococcus (MRS) accounted for 25% in all pathogenic microbes. Staphylococci showed high drug resistance rates to clindamycin, levofloxacin, and all of the first- and second-generation cephalosporins. MRS isolates in nonfracture group had higher drug resistance rates to clindamycin and levofloxacin than than those in fracture group. Gramnegative bacilli (GNB) showed high drug resistance rates to Aztreonam, gentamicin and all of the third- and fourth-generation cephalosporins. Furthermore, GNB isolates in the non-fracture group showed higher resistance rates to gentamicin and all of the third- and fourth-generation cephalosporins. CONCLUSIONS: MRS isolates in the non-fracture group showed higher drug resistance rates to clindamycin and levofloxacin, and GNB isolates in non-fracture group showed higher drug resistance rates to gentamicin and all of the third- and fourth-generation cephalosporins.
OBJECTIVE To investigate the application of high offset femoral stem prosthesis in primary total hip arthroplasty. METHODS From January 2015 to June 2017, 51 patients with unilateral hip diseases who underwent primary total hip arthroplasty with Corail high offset femoral stem prosthesis(KHO type) were selected for retrospective study, including 20 females and 31 males;the age ranged from 21 to 71 years old with an average of(50.8±13.3) years old. The abduction arm, femoral offset, acetabular offset and the length of lower limbs were measured on the positive X-ray film of hip joint after operation. Harris scores before and after operation and related complications were recorded, and the stability of prosthesis was analyzed. RESULTS The femoral offset, combined offset and abduction arm of the affected side were significantly greater than those of the healthy side(P<0.05). There was no significant difference in acetabular offset between the affected side and the healthy side (P>0.05). The femoral offset of 17 hips (33.3%) was reconstructed normally, of which 15 cases (88.2%) had equal length of both lower limbs. The femoral offset of 34 hips (66.7%) was greater than that of the healthy side, and 34 cases (100%) had equal length of both lower limbs. All 51 patients were followed up for(42.3±7.3) months. The Harris score increased from 38.0±7.6 before operation to 92.1±3.1 at the final follow-up(P<0.001). CONCLUSION Although the high offset Corail prosthesis can not normally reconstruct the femoral offset in unilateral primary total hip arthroplasty, it does not affect the reconstruction of the length of lower limbs and the stability of the prosthesis.
Background Managing periprosthetic joint infections are variable in practices. Debridement, antibiotics, and implant retention (DAIR) is one of the favorable interventions. Given that the success rate of the two-stage revision total knee arthroplasty (rTKA) might be overestimated. The purpose of this study is to compare the success rate between DAIR and standard two-stage rTKA with a comparable intervention time. Methods We retrospectively reviewed the consecutive knee periprosthetic joint infection cases which underwent DAIR or two-stage rTKA (all procedures were performed by the senior author) within 12 weeks since their primary TKA between July 2009 and October 2019. Average follow-up was 72.20 ± 40.70 months (range 29–148 months) in the DAIR group compared to 89.14 ± 43.06 months after spacer insertion (range 29–163 months) in the two-stage revision group ( P = 0.156). According to different interventions, demographic data; timing of surgical intervention; hospital for special surgery knee score; and success rate were collected and compared between the DAIR group and two-stage revision group. Failure of treatment was based on the Delphi consensus and the fate of spacers. The pathogen types and failure cases were also recorded and analyzed. Results Average follow-up was 72.20 ± 40.70 months (range 29–148 months) in the DAIR group compared to 89.14 ± 43.06 months after spacer insertion (range 29–163 months) in the two-stage revision group. Time from index surgery was 3.90 ± 2.92 weeks (range 0–12 weeks) in the DAIR group, and 5.11 ± 2.86 weeks (range 0–12 weeks) in the 2-stage exchange group, respectively. The success rate was 70.0% and 75.0% in the DAIR group and two-stage revision group, respectively. But no significant differences were observed between the two groups. Conclusion DAIR demonstrated comparable effectiveness with two-stage rTKA. We recommended DAIR as a choice for patients with current infection within 12 weeks after primary TKA. For methicillin-resistant staphylococcal infections and fungal infections, two-stage rTKA might be preferred.
Abstract Background With the development of radiology and three-dimensional (3D) printing technology, custom-made 3D-printed titanium augments have been more widely used. However, the radiological and clinical outcomes of custom-made augments lack reports. To better understand the clinical effect of using 3D-printed titanium augments and the significance of accurate placement, the aim of this study was to assess the outcomes when using custom-made 3D-printed titanium augments and to validate the idea that surgical simulation should be done before designing custom-made augments. Methods A retrospective review was conducted on 31 surgical simulations and revision total hip arthroplasties using custom-made 3D-printed titanium augments. The safe zone, cup position, and hip rotation center were measured on anteroposterior radiographs. Clinical outcomes were assessed with a mean 21.1 months of follow-up. Results All patients were positioned within the safe zone, and none of the acetabular cups nor the custom-made augments had any evidence of migration at the latest follow-up. A strong correlation was found between the planned cup position and the postoperative position. The average vertical position of the center of rotation was significantly increased from 3.55 cm to 2.35 cm. The mean Harris Hip Score was increased from 40.81 preoperatively to 65.46 postoperatively. Complications included gait abnormality, groin pain, fracture of the greater trochanter, and partial palsy of the sciatic nerve. However, patient satisfaction reached 92.3%. Conclusion Surgical simulations help to design custom-made augments accurately and improve surgical plans. Acetabular components supported with custom-made 3D-printed augments is a useful method to bridge severe bone deficiencies. In this study, both the radiologic results and clinical outcomes were favorable. Level of evidence Level 4.
Aims There are no methods to assess patient’s squatting ability after TKA (total knee arthroplasty), this study aimed to evaluate the different squatting position of a series of patients who underwent primary TKA.Methods From May 2018 to October 2019, we retrospectively reviewed 154 videos recording the squattin-related motions of patients after TKA. Among the included patients, 119 were women and 35 were men. Their mean age at the index surgery was 61.4 years (range, 30 to 77). The median follow-up was 12 months (range, 6 to 156). We classified those squatting-related motions into three major variations according to squatting depth: half squat, parallel squat, and deep squat. The angle of hip flexion, knee flexion and ankle dorsiflexion were measured in the screenshots captured from the videos at the moment of squatting nadir.Results A total of 26 patients were classified as half squat, 75 as parallel squat, and 53 as deep squat. The angle of hip flexion, knee flexion and ankle dorsiflexion all differed significantly among the three squatting positions (p<0.001). In the parallel squat group, the mean knee flexion angle(°) was 116.5 (SD, 8.1; range, 97 to 137). In the deep squat group, the mean knee flexion angle(°) was 132.5 (SD, 9.3; range, 116 to 158). Among the three squatting positions, deep squat showed the highest hip, knee and ankle flexion angle. And the next was parallel squat.Conclusion Our squatting position classification offers a pragmatic approach to evaluating patient’s squatting ability after TKA. However, the relation between squatting position and daily activity requires further investigation.
OBJECTIVE:To explore the coronal alignment of tibial prosthesis after osteotomy using personalized extramedullary positioning technique on tibia side in total knee arthroplasty (TKA). METHODS:A clinical data of 170 patients (210 knees) who underwent primary TKA between January 2020 and June 2021 and met the selection criteria was retrospectively analyzed. Personalized and traditional extramedullary positioning techniques were used in 93 cases (114 knees, personalized positioning group) and 77 cases (96 knees, traditional positioning group), respectively. The personalized extramedullary positioning was based on the anatomical characteristics of the tibia, a personalized positioning point was selected as the proximal extramedullary positioning point on the articular surface of the tibial plateau. There was no significant difference between the two groups in gender, age, body mass index, surgical side, course of osteoarthritis, and Kellgren-Lawrence classification ( P>0.05). The preoperative tibial bowing angle (TBA) formed by the proximal and distal tibial coronal anatomical axes in the personalized positioning group was measured and the tibia axis was classified, and the distribution of personalized positioning point was analyzed. The pre- and post-operative hip-knee-ankle angle (HKA), the lateral distal tibial angle (LDTA), and the postoperative tibia component angle (TCA), the excellent rate of tibial prosthesis alignment in coronal position were compared between the two groups. RESULTS:In the personalized positioning group, 58 knees (50.88%) were straight tibia, 35 knees (30.70%) were medial bowing tibia, and 21 knees (18.42%) were lateral bowing tibia. The most positioning points located on the highest point of the lateral intercondylar spine (62.07%) in the straight tibia group, while in the medial bowing tibia and lateral bowing tibia groups, most positioning points located in the area between the medial and lateral intercondylar spines (51.43%) and the lateral slope of the lateral intercondylar spine (57.14%), respectively. The difference in HKA between pre- and post-operation in the two groups was significant ( P<0.05); while the difference in LDTA was not significant ( P>0.05). There was no significant difference in preoperative LDTA and HKA and the difference between pre- and post-operation between groups ( P>0.05). But there was significant difference in postoperative TCA between groups ( P<0.05). The postoperative tibial plateau prosthesis in the traditional positioning group was more prone to varus than the personalized positioning group. The excellent rates of tibial prosthesis alignment in coronal position were 96.5% (110/114) and 87.5% (84/96) in personalized positioning group and traditional positioning group, respectively, showing a significant difference between groups ( χ 2=7.652, P=0.006). CONCLUSION:It is feasible to use personalized extramedullary positioning technique for coronal osteotomy on the tibia side in TKA. Compared with the traditional extramedullary positioning technique, the personalized extramedullary positioning technique has a higher excellent rate of tibial prosthesis alignment in coronal position.
Abstract Objective To report the long‐term outcomes of total hip arthroplasty (THA) with fourth‐generation ceramic‐on‐ceramic (CoC) bearing in patients with ankylosing spondylitis (AS). Methods We retrospectively identified 180 primary THAs performed in 110 patients with AS, including 100 (90.9%) men and 10 women (9.1%), from 2009 to 2011.The mean age of the patients at surgery was 33 years (range, 16 to 65 years). Cementless prostheses with fourth‐generation CoC bearings were used in all patients. Survivorship of the implants and postoperative complications were calculated. Functional improvement was assessed by the hip flexion‐extension range of motion (ROM) and Harris hip score (HHS). A special noise assessment questionnaire was performed at the last follow‐up. The cumulative incidence of noise was calculated by the Kaplan–Meier method with 95% confidence intervals (CIs). Clinical characteristics and functional outcomes were compared in the hips with noise to those without noise. Results The mean follow‐up was 11 years (range, 10 to 12 years), and survivorship of the implants was 99.4% at the most recent follow‐up. The complications included dislocation (one hip, 0.6%), periprosthetic joint infection (one hip, 0.6%), mild to moderate pain (five hips, 2.8%), heterotopic ossification (12 hips, 6.7%), and noise (52 hips, 28.9%). The flexion‐extension ROM improved significantly with a median from 10° (range, 0 ~ 130°) to 100° (30 ~ 130°) after THA (p < 0.001), and the HHS increased significantly from 41 ± 20 to 90 ± 8 (p < 0.001). The cumulative incidence of noise at 0.5, 5, and 10 years was 6.1% (95% CI, 2.6 ~ 9.6), 16.7% (95% CI, 11.2 ~ 22.1), and 28.9% (95% CI, 22.2 ~ 35.5), respectively, and that of squeaking at 0.5, 5, and 10 years was 4.4% (95% CI, 1.4 ~ 7.4), 13.3% (95% CI, 8.4 ~ 18.3), and 23.9% (95% CI, 17.6 ~ 30.1), respectively. None of the patients with noise generation in the hip reported it affecting daily activities or causing dissatisfaction. No differences in age, sex, BMI, disease duration, bilateral THA, the frequency of bony ankylosis, the proportion of using a 36‐mm‐diameter femoral head, pre/postoperative flexion‐extension ROM, or pre/postoperative HHS were found between hips with noise and those without noise (p > 0.05). Conclusion THAs with fourth‐generation CoC bearings exhibit excellent long‐term survival and clinical outcomes in patients with AS, with a very low dislocation rate. The incidence of noise associated with CoC bearings in THA performed in patients increases over time, but it does not affect postoperative hip function or daily activities.
There would be a major effect on the cartilage regeneration characteristics of ceramic material in a substrate implant requiring biologically active biomaterials and the reinforcement phase. At this moment, we produced collagen-hyaluronic acid @ hydroxyapatite-halloysite nanotube-single walled carbon nanotube composites, which is a successful technique for making a scaffold with a superior counter for cartilage property. FTIR, XRD, and SEM-EDAX were used to perform morphological and structural studies. The prepared composite's surface feature was investigated and discovered by HRTEM-SAED analysis, and it observed porous nature. The simulated body fluids (SBF) assessment of the materials was noticed their bioactivity and chondrocytes to determine their biocompatibility. Hybrid composite displayed promise for cartilage tissue engineering despite mesenchymal stem cells compatibility effect and magnificently demonstrated an antibacterial effect without antibiotics. The live/dead cells analysis shows that the composite can significantly improve mesenchymal stem cells, and the composite has the potential ability for cartilage regeneration. The above characteristics make the material quite interesting and important in the area for regenerative medicinal uses.
Objective Early prediction of stem version aids in optimization of combined version during total hip arthroplasty (THA). This study aimed to analyze the discrepancy between stem version and native femoral version measured by different methods, and to explore which method can better predict the stem version. Methods We retrospectively reviewed 26 patients (39 hips) treated with robot‐assisted THA in our hospital between September 2019 and December 2019. A straight, single‐wedge, cementless stem (Accolade II) was used in all cases. Preoperative femoral version was measured at three levels on computerized tomography (CT) scan from the top to the middle level of femoral neck (Level 1 to Level 3). During THA, the version on cutting surface was measured prior to femoral broaching based on two reference lines: mid‐cortical line and T line (trochanteric fossa to the middle of medial cortex). After femoral broaching, stem version was measured based on the femoral neck trial using Mako system (Stryker). In the statistical analysis, the difference and absolute discrepancy between stem version and femoral version measured with various methods were examined using paired t‐test, and the relationship between stem version and various femoral versions were examined using correlation analysis. Results Mean femoral neck version (Level 1) was 9.5° ± 2.6° (range, −16.8°‐42.5°), while mean stem version measured by Mako system was 19.9° ± 2.0° (range, −8.0°‐49.0°). Femoral version measured with each method showed a moderate correlation with stem version (p < 0.05). There was a significant difference between stem version and femoral version except at Level 3, with a mean difference of 0.8° ± 13.6° (p = 0.729). With regard to the intraoperative estimation, stem version significantly increased compared to the value based on mid‐cortical line, with a mean difference of 8.4° ± 13.1° (p < 0.001). However, the mean value of stem version was a little smaller than that of femoral version measured by reference to T line, but without statistical significance (p = 0.156). No postoperative dislocations occurred during the study period. No revision was required for any component. Conclusions The middle level of femoral neck on CT scan and T line on cutting surface are better references to measure femoral version for predicting postoperative stem version. However, the relationship between stem version and predictive value was flexible. Therefore, further three‐dimensional studies of postoperative CT are needed to validate the press‐fit fixation and rotational freedom of the single‐wedge stem.