Objective:Objectives The aim of the study is to evaluate the mechanical performance, safety and efficacy of the novel robotic-assistant flexible ureteroscopy system (Ra-fURS) under in vitro and in vivo environments.Methods:Combing with commercial flexible ureteroscopes, the novel Ra-fURS was used for the in vitro test and animal model operation in October 2020. The study included three sections. ①Basic mechanical performance assessment: including endoscope motion control (dual deflection, axial rotation and forward/backward distance), reaction time and fiber regulation. ②Simulated surgery in ex-vivo 3D-printing renal collecting system model: including completion rate and time of calyxes exploration, directional movement and laser fragmentation [gypsum models (0.5×0.5×0.5 cm) were used to stimulate kidney stones]. ③Intrarenal surgeries in animal models (two 5-month female Yorkshire white pigs). In total, 32 surgeries was performed (8 surgeons × 2 pigs × 2 kidneys/pig). In vivo assessments were carried out including: ①consuming time for Ra-fURS installation and offloading; ②completion rate and time of calyxes exploration; ③comfort score (ranging from 0-10) as compared to the manual f-URS, which was corresponding to each Ra-fURS surgery. In simulated surgery and animal surgery sections, 8 surgeons were enrolled in the study (group A 4 without flexible ureteroscopy experience; group B: 4 highly experienced), and results were compared between two groups.Results:Under the Ra-fURS control, the flexible ureteroscope movement in three degrees of freedom (forward / backward: + 11 to -11 cm, axial rotation + 225°to -225°; active duel-flection: + 270°to -270°, as well as the laser fiber regulation + 2.5 to -2.5 cm). In simulated surgery tests, both groups achieved 100% completion rate of calyxes exploration, and there were no statistical differences in the time of the calyxes exploration between group A and group B (116.0±8.0)s vs.(110.3±15.4)s( P>0.05). Time-consumption for laser fragmentation of group B was shorter than that of group A (525.8±58.5)s vs. (780.5±141.2)s( P<0.01). In animal surgery, the installation time of Ra-fURS gradually shortened within the first 7 cases was(234.0±43.0)s, and became comparable in the later 8-32 cases was(149.3±8.0)s. The average uninstall time was (43.9 ±5.9)s and was relatively stable. There were 51 renal calyxes in two pigs. It was higher for the completion rate of calyxes exploration in group B than in group A [(95.5±9.1)% vs. (59.1±9.1)%, P<0.05], and the exploration time was also statistically variant between the two groups group A and group B[(274.8±34.6)s vs.(127.3±18.2)s, P<0.05]. For all the operators, the comfort scores were favorable to the Ra-fURS as compared to the manual f-URS (8.9±0.3 vs. 5.9±1.1, P<0.05). Conclusions:This preliminary study demonstrated that the novel Ra-fURS was capable of controlling flexible ureteroscope to perform retrograde intrarenal surgery and fragmenting stones with laser. Besides, other features, including easy installation, stable performance and comfortable manipulating environment, made it easy to use in clinical application.
OBJECTIVE To assess the immediate analgesic effect of wrist-ankle acupuncture on acute lumbago and the relationship between the analgesic effect and the expectation of patients. METHODS A randomized, single-blind, sham-controlled trial was designed. Sixty cases of acute lumbago were randomly divided into two groups, 30 cases in each one. In observation group, wrist-ankle acupuncture was adopted to the Lower 5 and Lower 6 bilaterally, no requirement of Deqi (arrival of qi). In control group, sham acupuncture was adopted. The treatment was applied once in either group, with the needles retained for 30 min. The Short-form McGill Pain Questionnaire (SF-MPQ) and the Modified-Modified Schober (MMS) test were used to assess the motion related pain and the situation of spinal flexion in 3 min before treatment and 5 min, 10 min, 15 min, during treatment and 30 min (needle removed), respectively. The Expectation and Treatment Credibility Scale (ETCS) was applied to analyze the relationship between the expectation of patients and the analgesic effect. The adverse reaction was recorded. RESULTS There were no statistically significant differences in SF-MPQ, MMS and ETCS before treatment between two groups (all P>0.05). In 5 min after needles insertion, the scores of the items in SF-MPQ in observation group were lower than those in control group (P<0.05, P<0.01). In 10 min after needles insertion, the scores of SF-MPQ in observation group were lower than those in control group and the scores of MMS were higher than those in control group (P<0.05). In 15 min after needles insertion, except the sensory pain rating index, the scores of the rest items in SF-MPQ in observation group were all lower than those in control group (P<0.05, P<0.01). In 30 min (needles removed), the scores of affective pain rating index of SF-MPQ and Visual Analogue Scale (VAS) in observation group were lower than those in control group (P<0.05, P<0.01). The expectation before treatment was negatively correlated with VAS scores in 5 min, 10 min, 15 min and 30 min after needle insertion separately in observation group (P<0.05), while the correlation was not found in control group (P>0.05). No adverse reaction was reported. CONCLUSION Wrist-ankle acupuncture can reduce acute lumbago immediately and significantly. The higher the expectation on the analgesic effect of wrist-ankle acupuncture the patients have, the better the analgesic effect will be. This therapy is highly safe in the treatment.