Background: Imageless computer navigation improves component placement accuracy in total hip arthroplasty (THA), but variations in the registration process are known to impact final accuracy measurements. We sought to evaluate the registration accuracy of an imageless navigation device during THA performed in the lateral decubitus position. Methods: A prospective, observational study of 94 patients undergoing a primary THA with imageless navigation assistance was conducted. Patient position was registered using 4 planes of reference: the patient's coronal plane (standard method), the long axis of the surgical table (longitudinal plane), the lumbosacral spine (lumbosacral plane), and the plane intersecting the greater trochanter and glenoid fossa (hip-shoulder plane). Navigation measurements of cup position for each plane were compared to measurements from postoperative radiographs. Results: Mean inclination from radiographs (41.5 degrees +/- 5.6 degrees) did not differ significantly from inclination using the coronal plane (40.9 degrees +/- 3.9 degrees, P = .39), the hip-shoulder plane (42.4 degrees +/- 4.7 degrees, P = .26), or the longitudinal plane (41.2 degrees +/- 4.3 degrees, P = .66). Inclination measured using the lumbosacral plane (45.8 degrees +/- 4.3 degrees) differed significantly from radiographic measurements (P < .0001). Anteversion measured from radiographs (mean: 26.1 degrees +/- 5.4 degrees) did not differ significantly from the hip-shoulder plane (26.6 degrees +/- 5.2 degrees, P = .50). All other planes differed significantly from radiographs: coronal (22.6 degrees +/- 6.8 degrees, P = .001), lumbosacral (32.5 degrees +/- 6.4 degrees, P < .0001), and longitudinal (23.7 degrees +/- 5.2 degrees, P < .0001). Conclusion: Patient registration using any plane approximating the long axis of the body provided a frame of reference that accurately measured intraoperative cup position. Registration using a plane approximating the hip-shoulder axis, however, provided the most accurate and consistent measurement of acetabular component position. (C) 2021 Elsevier Inc. All rights reserved.
CASE:This report describes a case of an unstable spine fracture in the setting of severe degenerative disc disease in a patient who underwent a direct anterior total hip arthroplasty (THA). The patient was positioned supine on a standard operating room table and postoperatively complained of back pain and neurologic deficits. Advanced imaging identified a T12-L1 extension-distraction injury, and the patient ultimately required surgical decompression and spinal fusion. CONCLUSION:This case outlines a serious complication of THA that can occur in patients with degenerative spine disease and highlights the importance of taking precautions to reduce stress on the spine during surgery.
Shoulder and elbow replacement arthroplasty both achieve a high degree of success in patients with inflammatory arthritis. When both arthroplasties are performed on the same side, a stress riser can occur in the humeral diaphysis between the tips of the 2 humeral components. When the shoulder arthroplasty is performed first, a short-stemmed humeral component is advised. If a long-stemmed humeral component at either joint is already in place, the cement column for the subsequent arthroplasty should extend to and include the cement column for the extant component.
Nine metal on polyethylene total wrist arthroplasties were revised for failure, including eight trispherical devices and one Volz implant. Causes of failure include sepsis in one patient, progressive wrist flexion contracture in two patients, and mechanical failure in six patients. The most common mode of mechanical failure was metacarpal loosening with dorsal perforation of the stem. This was associated with an intact articulation between the third metacarpal and the capitate, with a proximal position of the metacarpal component in the shaft, and with poor cement fill of the metacarpal shaft. The one infected wrist was managed with resection arthroplasty. Five patients had conversion to a wrist arthrodesis and three patients underwent revision total wrist arthroplasty with custom trispherical components. Followup averaged 3.3 years. All patients undergoing arthrodesis attained a solid painless fusion after a single operation at an average of 4.8 months. The three patients treated with revision arthroplasty had wrists that were pain free, functional, and had no evidence of loosening at latest followup. Failed total wrist arthroplasties can be salvaged successfully to either a fusion or a revision arthroplasty in most patients.
The results using the anterior sliding graft technique with rigid internal fixation for tibiotalar arthrodesis were reviewed. The indications for anterior sliding graft technique included posttraumatic arthritis, rheumatoid arthritis, pseudarthrosis following prior attempt at arthrodesis, and postinfectious arthrosis. The arthrodesis rate was 95%. The overall prevalence of complications was 33%. The complications related to this method were minor and easily managed. The authors concluded that the anterior sliding graft technique is performed with readily available resources, has a high rate of union, and avoids the routine use of iliac bone graft.
u nsta e or al e bl fl .I lb ows significantly reduce upper extremity and hand function.20 These elbow abnormalities may occur in a number of circumstances but most frequently follow ununited elbow fractures,‘9, 22 traumatically deficient elbow joints, and severe destructive rheumatoid disease.4, 21 In elbow instability the patient is unable to position or posture the hand for normal function. Independent function of the contralateral hand is also affected, because it is frequently required to support the forearm and hand of the involved extremity. It is particularly troublesome when the dominant elbow is affected. This study reports on our experience with total elbow arthroplasty in patients with unstable or flail elbow joints caused by ununited fractures, traumatically deficient elbow articulations, and severe joint destruction in rheumatoid arthritis.
This paper will concern itself with the two extremes of elbow problems. First, I will review the results for stiff and ankylosed elbows and second, with flail or unstable elbows. Each of these represent unusual and challenging anatomic problems [4]. The ankylosed elbow partly represents an excess of anatomic resources, whereas the flail or unstable elbow represents a paucity or damaged anatomical resources. In both situations, there are serious functional and disabling problems which must be addressed by the surgeon [3].
We used survival analysis to evaluate 113 consecutive semiconstrained total elbow arthroplasties (TEAs) in 95 patients at a maximum follow-up of 99 months. Our criteria for failure were mechanical malfunction, revision for any reason, and deep infection. The primary diagnosis was inflammatory arthritis in 86 elbows, post-traumatic arthritis in 6, supracondylar nonunion or fracture in 12, osteoarthritis in 2 and other causes in 3. Seven failures were due to deep infection, and five of these had a primary diagnosis of inflammatory arthritis. Eight failures were revised or had revision recommended for aseptic loosening, and six of these were in patients with post-traumatic arthritis or supracondylar nonunion. The cumulative survival for TEAs performed for post-traumatic arthritis, fractures or supracondylar nonunion was 73% at three years and 53% at five years, significantly worse than the cumulative three- and five-year survivals of 92% and 90%, respectively, for patients with inflammatory arthritis. TEA with a semiconstrained prosthesis appears to have a satisfactory survival in selected patients with arthritic disorders. The incidence of deep infection was reduced by improvements in surgical technique and postoperative management, and the routine use of antibiotic-impregnated cement. The incidence of aseptic loosening was low, except in patients with supracondylar nonunion or post-traumatic arthritis.
Fifty-five patients with rheumatoid arthritis were treated with 65 triple arthrodeses of the hindfoot from March 1975 through July 1985. Twelve patients (12 procedures) have died, and follow-up evaluation could not be completed on three patients (four procedures), leaving 40 patients (49 procedures) available for clinical and roentgenographic evaluation. There were 32 women and eight men, with an average age at the time of surgery of 50 years. The follow-up period averaged five years. Standard operative technique involved medial and lateral incisions with staple fixation and local bone grafting. Correction of deformity was performed with closing wedge osteotomies. All patients had moderate to severe pain preoperatively and difficulty with ambulation. Postoperatively, 94% of the patients had significant pain relief and 83% had complete pain relief. Ambulatory status was improved in 80% of the patients. Ninety percent were at least community ambulators at the time of review, whereas more than half the patients were limited to household ambulation preoperatively. Complications included four superficial wound infections, all of which responded to local care. One patient required revision surgery for pseudarthrosis, and three patients had progression of ankle disease and required pantalar arthrodeses. There was no significant progression of fore-foot or knee symptoms, however, and there was no progression of ankle symptoms in patients whose hindfeet were corrected to 0 degrees-10 degrees valgus. Triple arthrodesis in the rheumatoid population has a high union rate. Pain relief and ambulation improvement can be expected.
Twenty-three patients with inflammatory arthritis and rotator cuff deficiency have undergone 27 custom-fit total shoulder arthroplasties. The design used included a short-stem humeral component and a metal-backed glenoid component with an offset keel. The glenoid component was custom-fit to provide maximum coverage of the glenoid surface. The average age of the patients at the time of surgery was 55 years (range, 20–75 years). All patients had inflammatory arthritis, 16 were on steroids, and all had some degree of rotator cuff involvement ranging from small to complete tears. The average length of follow-up study was 5 years (range, 3–7 years). The average preoperative shoulder score was 36 points (range, 15–50 points) with an average pain score of 7 (of 30) points. Postoperatively, the shoulder score improved to 85 points with a pain score of 28 points. Twenty-one shoulders scored a good to excellent result. Two patients required reoperation, both for recurrent rotator cuff tears, one of which occurred after a fall. Radiographic analysis revealed no incidence of humeral radiolucency and six cases of glenoid radiolucency. Only two of these were progressive and both were associated with irreparable rotator cuff tears. Thus, in the early follow-up, this design of glenoid has decreased the incidence of glenoid radiolucency in this difficult patient population.
Sixty-seven feet in forty-five patients who had rheumatoid arthritis were followed for an average of six years (range, four to ten years) after an operation on the forefoot that included resection of the metatarsophalangeal heads. or joints and the insertion of a double-stemmed silicone-rubber implant in the first metatarsophalangeal joint. There were forty-two women and three men, and the average age at the time of the operation was fifty-six years (range, thirty-six to seventy-nine years). The mean duration of known rheumatoid arthritis was fifteen years (range, three to thirty-seven years).Resection of the metatarsophalangeal heads or joints was performed through a plantar approach in forty-one feet and a dorsal approach in twenty-six feet. A double-stemmed silicone-rubber implant was placed in the first metatarsophalangeal joint in all feet.Each patient was evaluated clinically and radiographically with use of a foot-scoring system that was developed for this study. The results were assessed for relief of pain, ability to walk (including the use of shoes), presence of calluses or deformity, and radiographic findings. The average preoperative foot score was 47 points; the score had improved to an average of 81 points at the latest follow-up examination. A good or excellent result was obtained in fifty-eight feet (87 per cent).Complications were infrequent. In three feet, there was delayed healing of the wound; three implants were removed because of dislocation and infection; and four feet had revision to correct deformities of the lesser toes.
Log in or Register Get new issue alertsGet alerts Enter your Email address: Wolters Kluwer Health may email you for journal alerts and information, but is committed to maintaining your privacy and will not share your personal information without your express consent. For more information, please refer to our Privacy Policy. Subscribe to eTOC Secondary Logo Journal Logo All Articles Images Videos Podcasts Blogs Advanced Search Toggle navigation Register Login HomeCurrent IssuePrevious Issues Current Orthopaedic PracticeCurrent Opinion in Orthopaedics (1999-2007)Clinical Orthopaedics and Related Research (1976-2007) Published Ahead-of-PrintCOP eNewsMy CollectionsJournal Info About the JournalEditorial BoardInformation for AuthorsAdvertisingOpen AccessSubscription ServicesReprintsRights and Permissions All Articles Images Videos Podcasts Blogs Advanced Search
Sixty-seven feet in forty-five patients who had rheumatoid arthritis were followed for an average of six years (range, four to ten years) after an operation on the forefoot that included resection of the metatarsophalangeal heads or joints and the insertion of a double-stemmed silicone-rubber implant in the first metatarsophalangeal joint. There were forty-two women and three men, and the average age at the time of the operation was fifty-six years (range, thirty-six to seventy-nine years). The mean duration of known rheumatoid arthritis was fifteen years (range, three to thirty-seven years). Resection of the metatarsophalangeal heads or joints was performed through a plantar approach in forty-one feet and a dorsal approach in twenty-six feet. A double-stemmed silicone-rubber implant was placed in the first metatarsophalangeal joint in all feet. Each patient was evaluated clinically and radiographically with use of a foot-scoring system that was developed for this study. The results were assessed for relief of pain, ability to walk (including the use of shoes), presence of calluses or deformity, and radiographic findings. The average preoperative foot score was 47 points; the score had improved to an average of 81 points at the latest follow-up examination. A good or excellent result was obtained in fifty-eight feet (87 per cent). Complications were infrequent. In three feet, there was delayed healing of the wound; three implants were removed because of dislocation and infection; and four feet had revision to correct deformities of the lesser toes.
We report the case of a patient who had calcification in an stenosing tenosynovitis of the peroneus longus tendon associated with marked hypertrophy of the peroneal tubercle and an os peroneum
Forty-three prostheses with noncemented, high-molecular-weight, polyethylene-sleeved components were used in the treatment of bone tumors around the knee in growing children. The average age of the patients was 11 years. There were 27 boys and 16 girls. There were 17 sleeved components in the distal femur and 26 in the proximal tibia. The average follow-up time was 27 months. The roentgenograms were nominally obtained at three, six, 12, 18, and 24 months, and irregularly thereafter, and were assessed using a zonal evaluation scheme. A sclerotic interface around the polyethylene sleeves invariably developed and progressed in density up to 28 months postoperatively. There were significant zonal differences in sclerosis, particularly between the plateau and the mid-sleeve zone. Only in one patient did a sleeve become loose and require revision.
The authors reviewed the results of ankle arthrodesis in 68 ankles in 66 patients. The average follow-up period of the patients was five years (range, two to ten years). There were 40 ankles in which internal fixation was used and 28 ankles in which external fixation was used. The two groups were compared to determine the effect of mode of stabilization on outcome. Outcome was measured by time to union, development of complications, and clinical follow-up result. The groups were similar in regards to gender, age, and preoperative diagnosis. The external fixation group had a significantly higher prevalence of complications, including non-union, delayed union, and infection, than the internal fixation group. It was concluded that ankle arthrodesis with internal fixation is better tolerated and has fewer complications than techniques that use external fixation.