Total hip joint replacement (THR) is clinically well-established. In this context, the resulting range of motion (ROM) is crucial for patient satisfaction when performing joint movements. However, the ROM for THR with different bone preserving strategies (short hip stem and hip resurfacing) raises the question of whether the ROM is comparable with conventional hip stems. Therefore, this computer-based study aimed to investigate the ROM and type of impingement for different implant systems. An established framework with computer-aided design 3D models based on magnetic resonance imaging data of 19 patients with hip osteoarthritis was used to analyse the ROM for three different implant systems (conventional hip stem vs. short hip stem vs. hip resurfacing) during typical joint movements. Our results revealed that all three designs led to mean maximum flexion higher than 110 degrees. However, hip resurfacing showed less ROM (-5% against conventional and -6% against short hip stem). No significant differences were observed between the conventional and short hip stem during maximum flexion and internal rotation. Contrarily, a significant difference was detected between the conventional hip stem and hip resurfacing during internal rotation (p = 0.003). The ROM of the hip resurfacing was lower than the conventional and short hip stem during all three movements. Furthermore, hip resurfacing shifted the impingement type to implant-to-bone impingement compared with the other implant designs. The calculated ROMs of the implant systems achieved physiological levels during maximum flexion and internal rotation. However, bone impingement was more likely during internal rotation with increasing bone preservation. Despite the larger head diameter of hip resurfacing, the ROM examined was substantially lower than that of conventional and short hip stem.
AIMS Head-taper corrosion is a cause of failure in total hip arthroplasty (THA). Recent reports have described an increasing number of V40 taper failures with adverse local tissue reaction (ALTR). However, the real incidence of V40 taper damage and its cause remain unknown. The aim of this study was to evaluate the long-term incidence of ALTR in a consecutive series of THAs using a V40 taper and identify potentially related factors. METHODS Between January 2006 and June 2007, a total of 121 patients underwent THA using either an uncemented (Accolade I, made of Ti12Mo6Zr2Fe; Stryker, USA) or a cemented (ABG II, made of cobalt-chrome-molybdenum (CoCrMo); Stryker) femoral component, both with a V40 taper (Stryker). Uncemented acetabular components (Trident; Stryker) with crosslinked polyethylene liners and CoCr femoral heads of 36 mm diameter were used in all patients. At a mean folllow-up of 10.8 years (SD 1.1), 94 patients (79%) were eligible for follow-up (six patients had already undergone a revision, 15 had died, and six were lost to follow-up). A total of 85 THAs in 80 patients (mean age 61 years (24 to 75); 47 (56%) were female) underwent clinical and radiological evaluation, including the measurement of whole blood levels of cobalt and chrome. Metal artifact reduction sequence MRI scans of the hip were performed in 71 patients. RESULTS A total of 20 ALTRs were identified on MRI, with an incidence of 26%. Patients with ALTR had significantly higher median Co levels compared with those without ALTR (2.96 μg/l (interquartile range (IQR) 1.35 to 4.98) vs 1.44 μg/l (IQR 0.79 to 2.5); p = 0.019). Radiological evidence of osteolysis was also significantly associated with ALTR (p = 0.014). Median Cr levels were not significantly higher in those with ALTR compared with those without one (0.97 μg/l (IQR 0.72 to 1.9) v 0.67 μg/l (IQR 0.5 to 1.19; p = 0.080). BMI, sex, age, type of femoral component, head length, the inclination of the acetabular component, and heterotopic ossification formation showed no significant relationship with ALTR. CONCLUSION Due to the high incidence of local ALTR in our cohort after more than ten years postoperatively, we recommend regular follow-up investigation even in asymptomatic patients with V40 taper and metal heads. As cobalt levels correlate with ALTR occurrence, routine metal ion screening and consecutive MRI investigation upon elevation could be discussed. Cite this article: Bone Joint J 2022;104-B(7):852-858.
Dual-mobility cups (DMCs) were introduced in France more than 40 years ago and are increasingly used not only in hip revision but also primary hip arthroplasty. Due to a simulated large-head articulation and increased jumping distance, DMCs can contribute to a high range of motion in the hip joint and reduce the risk of instability. Numerous studies have reported low dislocation rates and high survival rates in the mid-term follow-up. Nevertheless, long-term data, especially on primary hip replacement, remain limited, and the effect of recent designs and material innovations is still unclear. Therefore, primary DMCs are mainly proposed in patients at high risk for dislocation (i.e. pelvitrochanteric insufficiency, compromised spinopelvic mobility, neuromuscular disorders, obesity and femoral neck fractures). Based on a review of recently published studies referring to these indications, the current study discusses the advantages and disadvantages of DMCs.
The calculation of range of motion (ROM) is a key factor during preoperative planning of total hip replacements (THR), to reduce the risk of impingement and dislocation of the artificial hip joint. To support the preoperative assessment of THR, a magnetic resonance imaging (MRI)-based computational framework was generated; this enabled the estimation of patient-specific ROM and type of impingement (bone-to-bone, implant-to-bone, and implant-to-implant) postoperatively, using a three-dimensional computer-aided design (CAD) to visualize typical clinical joint movements. Hence, patient-specific CAD models from 19 patients were generated from MRI scans and a conventional total hip system (Bicontact® hip stem and Plasmacup® SC acetabular cup with a ceramic-on-ceramic bearing) was implanted virtually. As a verification of the framework, the ROM was compared between preoperatively planned and the postoperatively reconstructed situations; this was derived based on postoperative radiographs (n = 6 patients) during different clinically relevant movements. The data analysis revealed there was no significant difference between preoperatively planned and postoperatively reconstructed ROM (∆ROM) of maximum flexion (∆ROM = 0°, p = 0.854) and internal rotation (∆ROM = 1.8°, p = 0.917). Contrarily, minor differences were observed for the ROM during maximum external rotation (∆ROM = 9°, p = 0.046). Impingement, of all three types, was in good agreement with the preoperatively planned and postoperatively reconstructed scenarios during all movements. The calculated ROM reached physiological levels during flexion and internal rotation movement; however, it exceeded physiological levels during external rotation. Patients, where implant-to-implant impingement was detected, reached higher ROMs than patients with bone-to-bone impingement. The proposed framework provides the capability to predict postoperative ROM of THRs.
Background The “cup-in-cup” technique allows for revision of failed total hip arthroplasty (THA) when the cementless cup is well fixed. Furthermore, it can be used for liner wear or mechanical failure where liner replacement may be impossible or impractical. Recently, the “cup-in-cup” technique in combination with dual mobility cups (DMC) has drawn increased attention. Our aim was to report on the clinical and radiographic outcomes following this surgery. Methods From 2015 to 2020, 33 patients treated with the DMC- “cup in cup” technique were retrospectively reviewed. Fourteen patients had died while 19 were available for the final follow-up (FU), of which 15 underwent both a radiograph and a FU visit, 2 underwent a radiograph only and 2 underwent a telephone interview only. Patient-related outcome measures included the HHS and the WOMAC. Radiographs were assessed for implant loosening and positioning. Primary endpoint was revision of any cause and secondary endpoint was loosening of the DMC at the latest FU. The survival analysis was conducted using the Kaplan-Meier method. Results The mean age at surgery was 78.6 ± 7.1 (63–93) years and the mean surgery duration was 124.4 ± 52.0 (60–245) minutes. Recurrent dislocation (42.4%), periprosthetic fracture (39.4%) and polyethylene wear (6.1%) were the most frequent reasons for surgery. The mean FU duration ( n = 19) was 28.5 ± 17.3 (3–64) months. The mean HHS score at FU was 59.4 ± 22.2 (29–91) and the mean WOMAC score was 59.7 ± 25.6 (15.6–93.8). Two cups were revised due to instability and one revision was performed due to periprosthetic joint infection, accounting for an overall cup survival rate of 86.8% after a mean FU of 22.9 ± 18.0 (1.5–64.6) months. The survival rate free of loosening was 90.9% after a mean FU of 22.3 ± 18.5 (1.5–64.7) months. Conclusions We found that the cementation of a DMC in a well-fixed cup is a promising short- to mid-term treatment addressing THA instability especially in elderly and frail patients, who benefit from a reduced operation time. Proper cementation technique, adequate cup positioning as well as selection of a sufficiently large DMC are crucial for treatment success. Longer FUs will be needed in the future in order to further prove the benefit of this technique.
ABSTRACT Salter innominate osteotomy (SIO) has been successfully used in the treatment of Legg–Calvé–Perthes disease (LCPD). Recent studies that have raised concerns about acetabular retroversion after SIO have been based on plain radiographs. In order to assess the true acetabular orientation, the present study uses a specific magnetic resonance imaging (MRI) technique. In addition, the association between acetabular morphology and clinical function as well as health-related quality of life was assessed. Twenty-three patients with 24 operated hips who underwent SIO for LCPD between January 2004 and November 2014 were included. Mean age was 8.5 ± 2.2 years at surgery and 18.5 ± 2.9 years at follow-up. MRIs were conducted at 1.5 T using radial sequences. The analysis included the acetabular version, acetabular sector angles (ASAs) and alpha angles. Plain radiographs were used in order to obtain the Stulberg classification. Patient-related outcome measures included the international Hip Outcome Tool and Euroqol-5 dimensions scores. In comparison to the non-operated side, the MRI of previously operated hips showed no difference of version at the center of the femoral head but significantly decreased version just below the roof level. As a marker for posterior acetabular coverage, the ASAs between 9 and 11 o’clock were significantly decreased when compared with non-operated hips. In hips with a mild acetabular retroversion (<15°), the function was significantly decreased when compared with non-retroverted hips. The SIO is an effective tool in order to restore acetabular containment in LCPD. When compared with the non-operated hips, our collective displays only moderate changes of acetabular orientation and coverage.
Abstract Purpose In hip dysplasia the Pemberton osteotomy can modify the shape of the acetabulum and is indicated for children aged between two and 12 when the triradiate cartilage is still open. However, there have been concerns about acetabular retroversion following this type of osteotomy. The studies, however, have been based on plain radiographs. The aim of our investigation was to assess the 3D acetabular orientation in patients with previous Pemberton osteotomy after skeletal maturation. Methods Ten patients with 12 operated hips were included who received Pemberton osteotomy for hip dysplasia between January 3, 2005 and March 25, 2011. Mean age at surgery and at follow-up were 7.2 years (sd 3.7) and 19.2 years (sd 3.7), respectively. MRIs were conducted with 1.5 T. Besides the measurement of acetabular version, the analysis included alpha angles, acetabular sector angles (ASAs) as well as modified ASAs (cartilage covered area angles). Furthermore, the presence of osteoarthritis (OA) as well as acetabular retroversion was determined on plain radiographs. Patient-related outcome measures included the international Hip Outcome Tool (iHOT) and EuroQol-5-Dimensions (EQ5D) scores. Results In comparison with the contralateral native and healthy hips the operated hips showed similar version (19.5° (sd 4.6°) versus 18.6° (sd 7.0°); p = 0.974). Also, there were no differences in terms of femoral head sphericity (alpha angles) and acetabular coverage (ASA angles). Five of 12 Pemberton hips showed signs of beginning OA (Kellgren-Lawrence classification I or II) while none of the non-operated hips did. Patients who received surgery before the age of six years had similar functional and radiological results when compared with patients who were older than six years at surgery. Among all patients, iHOT was 91.9 (sd 10.0) and EQ5D was 90.3 (sd 7.3)). Conclusion The Pemberton osteotomy provides good long-term radiographic and functional results without compromising acetabular version or coverage. Level of Evidence Level III: retrospective comparative study
Background Femoroacetabular impingement (FAI) can lead to morphologic damage of both the acetabulum and the femoral neck. Recent reports have found an association between impingement deformities and the development of femoral neck stress fractures. The aim of this study was to report a series of patients with these findings and to update the current evidence on the topic. Material and methods 5 patients (6 cases) with atraumatic femoral neck fractures and FAI were identified in the Dresden hip registry from 2015 to 2018. Demographic data, comorbidities, radiographic results and bone metabolism results were described. A literature search was conducted using keywords related to femoral neck stress fractures and FAI syndrome. Results The average age of the series was 39 (range: 22-52), 2 patients were female and 3 male. A total of 12 surgical procedures were performed. 4 of the 5 patients showed radiographic features of pincer and/or cam-FAI, whereas 3 patients had a decreased femoral antetorsion (-7 degrees to +7 degrees antetorsion). In 3 patients, magnetic resonance imaging revealed additional signs of avascular necrosis ARCO I. There was a lack of FAI-specific treatment recommendations in the available literature. Discussion Radiographic results of the patients evaluated suggested that impingement-associated deformities of the hip may cause femoral neck stress fractures, which is in line with the available literature. This potential coincidence should be integrated in diagnostic algorithms and therapeutic approaches.
Abstract Background Periacetabular osteotomy is a successful treatment for hip dysplasia. The results are influenced, however, by optimal positioning of the acetabular fragment, femoral head morphology and maybe even femoral version as well as combined anteversion have an impact. In order to obtain better insight on fragment placement, postoperative acetabular orientation and femoral morphology were evaluated in a midterm follow-up in regard to functional outcome and osteoarthritis progression. Methods A follow-up examination with 49 prospectively documented patients (66 hips) after periacetabular osteotomy (PAO) was performed after 62.2 ± 18.6 months. Mean age of patients undergoing surgery was 26.7 ± 9.6 years, 40 (82%) of these patients were female. All patients were evaluated with an a.p. pelvic x-ray and an isotropic MRI in order to assess acetabular version, femoral head cover, alpha angle, femoral torsion and combined anteversion. The acetabular version was measured at the femoral head center as well as 0.5 cm below and 0.5 and 1 cm above the femoral head center and in addition seven modified acetabular sector angles were determined. Femoral torsion was assessed in an oblique view of the femoral neck. The combined acetabular and femoral version was calculated as well. To evaluate the clinical outcome the pre- and postoperative WOMAC score as well as postoperative Oxford Hip Score and Global Treatment Outcome were analyzed. Results After PAO acetabular version at the femoral head center (31.4 ± 9.6°) was increased, the anterior cover at the 15 o’clock position (34.7 ± 15.4°) was reduced and both correlated significantly with progression of osteoarthritis, although not with the functional outcome. Combined acetabular and femoral torsion had no influence on the progression of osteoarthritis or outcome scores. Conclusion Long-term results after PAO are dependent on good positioning of the acetabular fragment in all 3 planes. Next to a good lateral coverage a balanced horizontal alignment without iatrogenic pincer impingement due to acetabular retroversion, or insufficient coverage of the anterior femoral head is important.
Aufgrund der Komplexität und Diversität der Erkrankungen in der Leistenregion bleibt die Abgrenzung der verschiedenen Weichteil- und Knochenpathologien im klinischen Alltag eine differenzialdiagnostische Herausforderung. Beim Sportler müssen bei einer Schmerzlokalisation im Bereich der Leiste das femoroacetabuläre Impingement (FAI) und die Sportlerleiste als wichtige Ursachen für den Leistenschmerz in Betracht gezogen werden, wobei das häufige Auftreten von Doppelpathologien die Diagnostik weiter erschwert. Trotz der Bedeutung des Leistenschmerzes und seiner Differenzialdiagnosen im klinischen Alltag existieren aber bisher keine anerkannten Empfehlungen für das diagnostische Vorgehen. Mit diesem Ziel fand im Februar 2017 ein Konsensustreffen statt, an dem eine paritätisch zusammengesetzte Gruppe von Leisten- und Hüftgelenkchirurgen teilnahm. Mit der Formulierung von Empfehlungen und der Erstellung eines praktikablen Diagnostikpfads sollen die an der Behandlung dieser Patienten beteiligten Kollegen sensibilisiert werden, ferner soll die Qualität der Diagnostik von Leistenschmerzen im klinischen Alltag verbessert werden.
Objective This study aimed at investigating the agreement between predefined quantitative parameters of hip morphology derived from magnetic resonance imaging (MRI) and virtual range of motion (ROM) analysis using computed tomography (CT) as standard of reference. Methods Twenty patients (13 females, 7 males, 16–59 years) with hip deformities underwent MRI prior to surgery. Clockwise alpha angle, femoral head and neck diameter, collum caput diaphysis angle, femoral torsion, center-edge angles, acetabular coverage of the femoral head, sourcil angle, and acetabular anteversion were measured. Additionally, tern single and combined movements were simulated using a motion analysis program. The MRI findings were compared with the corresponding results obtained by CT. Correlation of MRI with CT was assessed using different statistical methods (intraclass correlation coefficient, Bland–Altmann plot, two one-sided t test), and linear regression analysis was performed. Results The results showed near-perfect intraclass correlation coefficients (ICCs) for anteversion (0.95), acetabular sector angles (0.98–0.99), sourcil angle (0.95), and acetabular coverage (anterior 0.96, posterior 0.99). Intermethod correlation for femoral parameters showed almost perfect agreement except for the alpha angle (0.73–0.97). No significant proportional bias was detected for traditional acetabular and femoral parameters. ROM analysis was performed for 370 movements in 37 hips. For 78.4% (290/370) of the movements analysed, neither CT nor MRI detected impingement across the physiological ROM. For 18.6% (69/370) of the movements, impingement was detected by both CT and MRI, while 2.2% (8/370) of the movements with impingement in CT showed no impingement in MRI, and 0.8% (3/370) of the movements with impingement in MRI had no corresponding result in CT. Conclusion Finally, it was concluded that MRI-based assessment of hip morphology and virtual ROM analysis is feasible and can be performed with good intermethod agreement in comparison to the gold standard (CT). Therefore, MRI appears to be substantially equivalent to CT for use in virtual ROM analysis and so may reasonably be used in place of CT for this purpose.
Fragestellung Pemberton und Salter-Osteotomien dienen der verbesserten Pfannenüberdachung bei Patienten mit Hüftdysplasie und anderen kindlichen Hüfterkrankungen wie Morbus Perthes. Einige Nachuntersuchungen beschreiben eine durch die Osteotomien induzierte azetabuläre Retroversion und damit induziertes Pinzer-Impingement, insbesondere nach Pemberton-Osteotomien. Bisherige Studien haben bis jetzt meist röntgenologische Parameter ausgewertet. Unser Ziel war es, die azetabuläre Orientierung in einem konsekutiven Kollektiv dreidimensional anhand von MRT- Aufnahmen nach Wachstumsabschluss zu beurteilen.
Fragestellung Aktuell wird in der Hüftendoprothetik zunehmend die Möglichkeit der Korrosion zwischen Konus und Kopf in der Literatur diskutiert. Eine Vielzahl möglicher Einflussfaktoren zu denen auch die Materialkombination von Schaft und Kopf sowie die Konusform zählt, ist mittlerweile beschrieben. In unserer Studie untersuchten wir Inzidenz und Ausmaß einer adverse reaction to metal debris (ARMD) im langfristigen Verlauf nach Implantation einer Hüftendoprothese mit V40 Konus.
Femoroazetabuläres Impingement (FAI) kann infolge unnatürlicher Druckmechanismen zu Strukturschäden von Pfanne und Schenkelhals führen. Bislang wenig beachtet ist das vereinzelt beschriebene Phänomen von Stressfrakturen des Schenkelhalses im Zusammenhang mit FAI. Ziel dieser Arbeit ist eine Zusammenstellung eigener Fälle und die Beschreibung der verfügbaren Literatur. Im Dresdner Hüftregister wurden von 2015 bis 2018 fünf Patienten mit nichttraumatischer Schenkelhalsfraktur und gleichzeitigem FAI operativ versorgt. Es erfolgte die retrospektive Auswertung soziodemografischer Merkmale der betroffenen Patienten sowie Komorbiditäten, radiologischer Befunde und endokrinologischer Diagnostik. Zusätzlich wurde eine Literatursuche mit Stressfraktur- und FAI-assoziierten Schlüsselwörtern vorgenommen. Das Durchschnittsalter der 5 behandelten Patienten (6 Frakturen) beträgt 39 Jahre (22–52 Jahre), 2 davon sind weiblich und 3 männlich. Es wurden insgesamt 12 operative Eingriffe durchgeführt. In 4 von 5 Fällen besteht ein Pincer-FAI oder/und ein Cam-FAI und bei 3 von 5 Patienten ist die femorale Antetorsion vermindert (−7° bis +7° Antetorsion). Drei Patienten weisen eine zusätzliche Durchblutungsstörung des Hüftkopfes im Sinne einer avaskulären Nekrose ARCO-Stadium 1 auf. In bislang publizierten Kasuistiken sind ähnliche Verläufe beschrieben, ohne FAI-spezifische Therapiemaßnahmen zu adressieren. Die Auswertung unserer Fälle sowie die Analyse ähnlicher Verläufe in der bislang publizierten Literatur legt nahe, dass Impingement-assoziierte Deformitäten zu den Risikofaktoren für die Entstehung von Stressfrakturen des Schenkelhalses zählen und bei der diagnostischen Abklärung bzw. Therapieplanung zu berücksichtigen sind.
Acetabular chondral lesions are common in patients with FAI. For large full-thickness cartilage defects, arthroscopic matrix-associated autologous chondrocyte transplantation (MACT) using an injectable in situ crosslinking product is an option. Aim of the study was to evaluate clinical and MRI results 12 months after MACT of acetabular cartilage defects in FAI patients. We report data on 21 patients with a focal cartilage defect of the hip [2.97 ± 1.44 cm2 (mean ± SD)] caused by FAI treated with an arthroscopically conducted MACT combined with FAI surgery. The results were assessed with patient-reported outcome measures (iHOT33, EQ-5D) pre- as well as post-operatively and by MRI using MOCART scoring system 6 and 12 months post-operatively. The iHOT33 score improved from 52.9 ± 21.14 (mean ± SD) pre-operative to 81.08 ± 22.04 (mean ± SD; p = 0.0012) 12 months post-operatively. The lower the pre-operative iHOT33 score and the larger the defect size, the greater the observed improvement compared to pre-operative scores at 12 months. Patients showed a significant improvement in EQ-5D-5L index value (p = 0.0015) and EQ-5D VAS (p = 0.0006). MRI analysis after 12 months revealed a complete integration of the transplant in 16 of 20 patients. Injectable MACT is a promising minimally invasive treatment option for full-thickness cartilage defects of the hip caused by FAI. A significant improvement in symptoms and function associated with an increase in quality of life was detected in patients treated with injectable MACT combined with FAI surgery. This is of considerable clinical relevance, since, in addition to the elimination of the mechanical cause, MACT allows the successful therapy of consequential cartilage damage. Level 4, case series.
Die Prävalenz der Hüftdysplasie liegt in epidemiologischen Studien zwischen 1 und 20 %. Die damit verbundene Deformität gilt als Risikofaktor für sekundäre Koxarthrosen.
Die periazetabuläre Osteotomie (PAO) ist ein effektives Verfahren zur Behandlung der symptomatischen Hüftdysplasie. Voraussetzung für ein gutes Therapieergebnis ist eine angemessene Patientenselektion. Ziel dieser Untersuchung ist, den Einfluss des Patientenalters zum Operationszeitpunkt auf das klinische Ergebnis zu prüfen.
Background Appropriate three-dimensional imaging of the hip joint is a substantial prerequisite for planning and performing surgical correction of deformities. Although surgeons still use computed tomography (CT), modern and fast acquisition techniques of volumetric imaging using magnetic resonance imaging (MRI) for pelvic measurements enable similar resolution. Purpose This study was designed to determine if already described measures of acetabular morphology are comparable in both techniques and if assessment can be performed with equal intra-observer and inter-observer reliability. Material and Methods Thirty-two hips (16 patients) were examined with a pelvic CT and a MRI with 3-T. Pelvic orientation was standardized by each observer in coronal, axial, and sagittal planes. Acetabular version as well as seven acetabular sector angles were measured by two observers twice with a minimum of four weeks between sessions. Results Inter-rater reliability showed excellent results for intra- and inter-rater reliability for CT (0.977–0.999) and MRI (0.969–0.998) measuring acetabular version and sector angles. Evaluating the reliability of CT and MRI for each observer revealed excellent results (0.972–0.998). Evaluating the Bland–Altman plots for intra-observer reliability showed an equal distribution of angles, within acceptable 95% limits of agreement. The same results were observed for inter-observer reliability evaluating CT and MRI as well as inter-method reliability. Conclusion Modern MRI scans are equally applicable to assess the bony pelvis as CT scans. In addition, MRI would enable the examination of soft tissues such as chondrolabral structures and muscle in the same examination. Since hip-preserving surgery is mostly conducted in younger patients, the reduction of radiation exposure is a benefit.