Background/Objectives: Our study brings a new method to properly evaluating drug efficacy at the non-invasive in vitro level. Methods: In this work, the electrochemical mediator-free and reagent-free analysis of cell lines based on the registration of electrochemical profiles of membrane proteins was developed. We studied the specificity of cell lines Wi-38 and HepG2 and the toxic effects of drugs on cell-on-electrode systems. Results: A linear dependence of the peak current on the concentration of cells applied to the electrode in the range from 1 × 105 to 6 × 105 cells/electrode was registered (R2 0.932 for Wi-38 and R2 0.912 for HepG2). The water-soluble form of phosphatidylcholine (wPC) nanoparticles recommended for atherosclerosis treatment and prevention of cardiovascular diseases did not show a toxic effect on the human fibroblast cells, Wi-38, or the human hepatocellular carcinoma cells, HepG2, at sufficiently high concentrations (such as 0.1–1 mg/mL). The antitumor drug doxorubicin, at concentrations of 3 and 10 μg/mL, showed a pronounced toxic effect on the tested cell lines, where the percentage of living cells was 50–55%. Conclusions: A comparative analysis of the cytotoxicity of wPC (0.1–1 mg/mL) and doxorubicin (3–10 μg/mL) on the cell lines Wi-38 and HepG2 using the MTT test and electrochemical approach for the registration of cells showed their clear adequacy.
This article discusses the role of phospholipids as a key component of high-density lipoproteins (HDL) involved in the reverse transport of cholesterol from cells with its subsequent excretion from the body. The results of the phospholipidation research on the capacity of HDL cholesterol efflux from macrophages, as well as an assessment of the hypolipidemic and antiatherogenic effects of phospholipids on an atherosclerosis rabbit model at the functional and morphological levels are presented. In phase I clinical trial the safety of the oral administration of the innovative water-soluble pharmaceutical form of phosphatidylcholine in healthy volunteers was proven. In a double-blind, placebo-controlled phase II-III clinical trial in patients with combined hyperlipidemia its efficacy in achieving of the non-HDL cholesterol and triglycerides therapeutic target and safety with long-term oral administration was demonstrated.
Aim . Determination of the catalytic activity of a single molecule of horseradish peroxidase (HRP) in the oxidation reaction of the substrate 2,2ʹ-azino-bis-[3-ethylbenzthiazoline-6- sulfonate] (ABTS) with hydrogen peroxide. Methodology . To determine (monitor) the catalytic activity of HRP, pore technology has been used; it has allowed us to analyze the activity of a single HRP molecule without introducing additional components into the system to enhance the signal. For this purpose, a solid-state pore of about 5 nm in size, formed by electron-beam drilling in a silicon nitride plate of ~40 nm thickness, has been used. A HRP molecule has been embedded in this pore, after which the catalytic activity of the molecule embedded in the pore in the presence of ABTS and H 2 O 2 has been analyzed by measuring the ion current through the pore with the HRP molecule embedded in it. Results. A pore detector has been proposed to study the catalytic activity of HRP in the reaction of ABTS oxidation. It has been found that this detector made it possible to monitor the activity of this enzyme by registering of ion current through the pore. Research implications . It has been shown that the manufactured pore can be used to monitor HRP activity. The results obtained are important for the development of work in the field of enzyme research at the level of single molecules.
Herein, we report the use of a nanotechnology-based approach for the study of enzyme-functionalized mica surfaces. Atomic force microscopy (AFM) has been employed for the determination of the catalytic activity of single molecules of heme-containing cytochrome P450 CYP102A1 (CYP102A1) enzyme, which was immobilized on the surface of a mica chip. Height fluctuations in individual molecules of the enzyme were measured under near-native conditions by AFM measurements in liquid using a cantilever with a 10 to 20 nm tip curvature radius. We have found that in the process of enzymatic catalysis, the mean amplitude of height fluctuations in individual enzyme molecules is 1.4-fold higher than that of enzyme molecules in an inactive state. The temperature dependence of the mean amplitude of height fluctuations in cytochrome CYP102A1 has been revealed, and the maximum of this dependence has been observed at 22 °C. The proposed nanotechnology-based approach can be employed in studies of a wide variety of enzymes, which are important for the development of novel diagnostic tests and systems for pharmaceutical analysis. The approach developed in our work will favor further miniaturization of enzyme-based biosensors and the transition from traditional sensors to nanobiosensors.
The activity of cytochrome P450 enzymes decreases in older adults, which can lead to toxic effects from polypharmacy. Cytochromes P450 are the most significant enzymes involved in the metabolism of foreign compounds, including pharmaceutical substances. Vitamin B2, or riboflavin (RF), is a potent antioxidant that is vital for the body and participates in numerous enzyme-catalyzed redox reactions. RF is phosphorylated intracellularly to form flavin mononucleotide (FMN), which is further metabolized into flavin adenine dinucleotide (FAD). The active site of the NADPH-dependent cytochrome P450 reductase (CPR), a redox partner of CYP enzymes, is necessary for the catalytic functions of cytochromes P450. The active site of reductase is a complex formed by two types of vitamin B2, such as flavin adenine dinucleotide (FAD) and flavin mononucleotide (FMN). In our study, we investigated the impact of the phosphorylated form of vitamin B2, FAD, and FMN on the catalytic activity of cytochrome P450 2C9 (CYP2C9) towards non-steroidal anti-inflammatory medications diclofenac and naproxen. It was shown that FAD significantly enhanced the catalytic efficiency of CYP2C9. The 4-hydroxylation of diclofenac was enhanced by 148 ± 10%. The O-demethylation of naproxen showed an increase of 120 ± 14%. Based on these data, we can assume that intake of vitamin B2 (riboflavin) improves catalytic efficiency of CYP2C9. This finding is essential for the modulation of catalytic activity of CYP2C9. The proposed electroanalytic approach is a sensitive and robust method for drug metabolism assay.
This study aimed to investigate whether the water-soluble pharmaceutical form of phosphatidylcholine nanoparticles (wPC) stimulated the catalytic activity of CYP enzymes 2C9 and 2D6. We have shown that electroenzymatic CYP2C9 catalysis to nonsteroidal anti-inflammatory drug naproxen as a substrate was enhanced from 100% to 155% in the presence of wPC in media. Electroenzymatic CYP2D6 activity in the presence of the adrenoceptor-blocking agent bisoprolol as a substrate was elevated significantly from 100% to 144% when wPC was added to potassium phosphate buffer solution. These results indicate the ability of wPC in the form of the phospholipid ultra-small nanoparticles to work as a membrane additive and crowding agent to accelerate the electroenzymatic reactions of cytochrome P450.
This article provides a systematic review of research conducted on the proteomic composition of blood as part of a complex biological age estimation. We performed a comprehensive analysis of 17 publicly available datasets and compiled an integral list of proteins. These proteins were sorted based on their detection probability using mass spectrometry in human plasma. We propose this list as a basis for creating a panel of peptides and quantifying the content of selected proteins in the format of a proteomic aging clock. The selected proteins are especially notable for their roles in inflammatory processes and lipid metabolism. Our findings suggest, for the first time, that proteins associated with systemic disorders, including those approved by the FDA for clinical use, could serve as potential markers of aging.
Limit of detection (LoD) is a term that is used to characterize the sensitivity of an analytical method. The existing limitation of the sensitivity of analysis using modern mass spectrometry methods has been experimentally shown to be a limiting factor in the application of proteomic technologies in medicine. This article proposes a concept of a new technology that will set a new vector of development in the development of systems for solving problems of medical diagnostics and deals with theoretical and practical aspects of creating a new technology for the detection of single biomacromolecules (in particular, proteins) in biological samples. Such technology should be based on the principle of signal registration similar to that used in a Geiger counter (also known as a Geiger–Müller counter or G-M counter), a device that automatically counts the number of ionizing particles that hit it. This counter is free from probabilistic components; it registers a signal if there is at least one target molecule in the analysis chamber. Predictive medical diagnostics require technology based on methods where sensitivity allows for the detection of single marker molecules in a biological sample volume of 1–10 µL, the smallest volume of biomaterial used in laboratory diagnostics. Creation of a detector with a sensitivity of 10−18 M would allow for the detection of one molecule in 1 µL of the sample, which fundamentally makes this approach analogous to a G-M counter for solutions. To date, bioanalytical methods are limited to a sensitivity of 10−12 M (which is approximately 1 million molecules per 1 μL), which is insufficient to capture the early stages of pathological processes.
Background and purpose: Combined hyperlipidemia is associated with an increased risk of cardiovascular events. This clinical trial investigated phospholipovit (essential phospholipids, Institute of Biomedical Chemistry, Moscow, Russia), an ultra-small phospholipid nanoparticle (micelles), targeted to phospholipids of HDL in lowering non-HDL-cholesterol (non-HDL-C) and triglycerides (TG) levels in patients with combined hyperlipidemia and moderate cardiovascular risk. Experimental approach: A randomized, double-blinded, placebo-controlled phase II trial was conducted on 100 patients. Phospholipovit or placebo was randomly administered orally (500 mg) 2 times a day for 12 weeks. The primary endpoint was the percent change of non-HDL-C from baseline to 12 weeks of exposure. Findings/Results: Treatment with phospholipovit resulted in a mean non-HDL-C reduction of 13.2% versus 4.3% compared with placebo. The absolute decrease in non-HDL-C was -23.2 (-48.7 - 7.0) mg/dL versus -7.3 (-17.0 - 12.0) mg/dL, significantly. The therapeutic target of non-HDL-C less than 130 mg/dL (3.4 mmol) was achieved in 15 of 39 patients (38.5%) in the phospholipovit group versus 2 of 41 patients (4.9%) in the placebo group OR 11.8 (2.4 - 116). Significant reduction in TG, apolipoprotein B, total cholesterol, and very low-density lipoprotein cholesterol levels was also observed. There were no changes in the liver and kidney functions, vital signs, or electrocardiography. There were no serious adverse events. Conclusion and implications: Phospholipovit significantly reduced non-HDL-C, TG, and atherogenic lipoproteins in patients with combined hyperlipidemia and moderate cardiovascular risk. It can be used as an add-on therapy to statins.
The search for minimally invasive methods for diagnostics of colorectal cancer (CRC) is the most important task for early diagnostics of the disease and subsequent successful treatment. Human plasma represents the main type of biological material used in the clinical practice; however, the complex dynamic range of substances circulating in it complicates determination of CRC protein markers by the mass spectrometric (MS) method. Studying the proteome of extracellular vesicles (EVs) isolated from human plasma represents an attractive approach for the discovery of tissue-secreted CRC markers. We performed shotgun mass spectrometry analysis of EV samples obtained from plasma of CRC patients and healthy volunteers. This MS analysis resulted in identification of 370 proteins (which were registered by at least two peptides). Stable isotope-free relative quantitation identified 55 proteins with altered abundance in EV samples obtained from plasma samples of CRC patients as compared to healthy controls. Among the EV proteins isolated from blood plasma we found components involved in cell adhesion and the VEGFA-VEGFR2 signaling pathway (TLN1, HSPA8, VCL, MYH9, and others), as well as proteins expressed predominantly by gastrointestinal tissues (polymeric immunoglobulin receptor, PIGR). The data obtained using the shotgun proteomic profiling may be added to the panel for targeted MS analysis of EV-associated protein markers, previously developed using CRC cell models.
Experimental methods of single-molecule enzymology allow scientists to determine physicochemical properties of distinct single molecules of various enzymes and to perform direct monitoring of functioning of enzymes at different steps of their catalytic cycle. The approach based on the use of solid-state nanopores is a promising tool for studying the functioning of single-enzyme molecules. Herein, this approach is employed for monitoring the functioning of cytochrome P450 BM3, which represents a very convenient model of cytochrome P450-containing monooxygenase systems. A nanopore of ~5 nm in diameter has been formed in a 40 nm-thick silicon nitride chip by electron beam drilling (EBD), and a single molecule of the BM3 enzyme has been entrapped in the pore. The functioning of the enzyme molecule has been monitored by recording the time dependence of the ion current through the nanopore during the reaction of laurate hydroxylation. In our experiments, the enzyme molecule has been found to be active for 1500 s. The results of our research can be further used in the development of highly sensitive detectors for single-molecule studies in enzymology.
In terms of time, cost, and reproducibility of clinical laboratory tests, a mass spectrometric clinical blood metabogram (CBM) enables the investigation of the blood metabolome. Metabogram’s components provide clinically relevant information by describing related groups of blood metabolites connected to humoral regulation, the metabolism of lipids, carbohydrates and amines, lipid intake into the organism, and liver function. For further development of the CBM approach, the ability of CBM to detect metabolic changes in the blood in the early stages of Parkinson’s disease (PD) was studied in this work. In a case-control study (n = 56), CBM enabled the detection of the signature in blood metabolites related to 1–2.5 clinical stages of PD, according to the modified Hoehn and Yahr scale, which is formed by alterations in eicosanoids, phospholipids and, presumably, in the butadione metabolism. The CBM component-based diagnostic accuracy reached 77%, with a specificity of 71% and sensitivity of 82%. The research results extend the range of disorders for which CBM is applicable and offer new opportunities for revealing PD-specific metabolic alterations and diagnosing early-stage PD.
Rationale: Colorectal cancer (CRC) is one of the most prevalent oncological diseases with high mortality. Invasive optical (endoscopic) colono- scopy has been recognized as a golden standard for the CRC diagnostics. A promising area is the development of non-invasive tools for CRC diagnosis with circular RNA (circRNA). One of the most sensitive non-invasive tools for detection of cancer RNA markers is considered to be the biosensor methods with the use of nanowire chips with oDNA probes (fragments of DNA oligonucleotides) immobilized on their surface. It has been previously shown that circRNA hsa_circ_0136666_CBC1, hsa_circ_0031263_CBC1, and hsa_circ_0072715_CBC1 are associated with CRC. Aim: To determine the lower limit of concentration sensitivity of detection of CRC-associated circRNA with nanowire chips with immobilized oDNA probes, to demonstrate the usability of these chips for non-invasive detection of circRNA in plasma in the CRC diagnostics, and to establish the potential for the use of nanowire chips for the early CRC diagnosis. Methods: To ensure biospecific binding of the circRNA hsa_circ_0136666_CBC1, hsa_circ_0031263_CBC1, and hsa_circ_0072715_CBC1 (the CRC markers), oDNA probes with the nucleotide sequences complementary to the target circRNA have been immobilized on the nanowire surface. At the study step 1, we detected the lower concentration limit for detection of the target molecules with the use of their analogues, i.e. synthetic model oDNA with the nucleotide sequences complementary to oDNA probes. At the study step 2, we used the nanowire chips with immobilized oDNA probes to detect the circRNA in plasma of the patients with confirmed CRC. Plasma samples from non-cancer patients were used as controls. Results: The lower concentration limit for the detection of DNA analogues of the circRNA hsa_circ_0136666_CBC1, hsa_circ_0031263_CBC1, and hsa_circ_0072715_CBC1 with nanowire chips with oDNA probes was 10-16 М. The analysis of total RNA isolated from plasma of the CRC patients showed a significant increase in the signal from the sensory elements of the nanowire chip. The analysis of plasma samples from the non-cancer patients, the nanowire signal changes were non-significant indicating the absence of detectable concentrations of the circRNA in plasma of the non-cancer patients. Conclusion: We have identified the minimal detectable concentration of the circRNA hsa_circ_0136666_CBC1, hsa_circ_0031263_CBC1, and hsa_circ_0072715_CBC1, associated to the development of CRC, with nanowire chips with immobilized oDNA probes: it was 10-16 М. The experiment showed the usability of such nanowire chips for non-invasive detection of the given circRNA markers in total RNA samples isolated from plasma of CRC patients.
Electrochemical profiling of formaldehyde-inactivated poliovirus particles demonstrated a relationship between the D-antigen concentration and the intensity of the maximum amplitude currents of the poliovirus samples. The resultant signal was therefore identified as electrochemical oxidation of the surface proteins of the poliovirus. Using registration of electrooxidation of amino acid residues of the capsid proteins, a comparative electrochemical analysis of poliovirus particles inactivated by electrons accelerated with doses of 5 kGy, 10 kGy, 15 kGy, 25 kGy, 30 kGy at room temperature was carried out. An increase in the radiation dose was accompanied by an increase in electrooxidation signals. A significant increase in the signals of electrooxidation of poliovirus capsid proteins was detected upon irradiation at doses of 15-30 kGy. The data obtained suggest that the change in the profile and increase in the electrooxidation signals of poliovirus capsid proteins are associated with an increase in the degree of structural reorganization of surface proteins and insufficient preservation of the D-antigen under these conditions of poliovirus inactivation.
Background: The incidence of many diseases increases with age and leads to multimorbidity, characterized by the presence of multiple diseases in old age. This phenomenon is closely related to systemic metabolic changes; the most suitable way to study it is through metabolomics. The use of accumulated metabolomic data to characterize this phenomenon at the system level may provide additional insight into the nature and strength of aging–disease relationships. Methods: For this purpose, metabolic changes associated with human aging and metabolic alterations under different pathological conditions were compared. To do this, the published results of metabolomic studies on human aging were compared with data on metabolite alterations collected in the human metabolome database through metabolite set enrichment analysis (MSEA) and combinatorial analysis. Results: It was found that human aging and pathological conditions involve the set of the same metabolic pathways with a probability of 99.96%. These data show the high identity of the aging process and the development of diseases at the metabolic level and allow to identify the set of metabolic pathways reflecting age-related changes closely associated with health. Based on these pathways, a metapathway was compiled, changes in which are simultaneously associated with health and age. Conclusions: The knowledge about the strength of the convergence of aging and pathological conditions has been supplemented by the rigor evidence at the metabolome level, which also made it possible to outline the age and health-relevant place in the human metabolism.
Using analytical technologies it is possible now to measure the entire diversity of molecules even in a small amount of biological samples. Metabolomic technologies simultaneously analyze thousands of low-molecular substances in a single drop of blood. Such analytical performance opens new possibilities for clinical laboratory diagnostics, still relying on the measurement of only a limited number of clinically significant substances. However, there are objective difficulties hampering introduction of metabolomics into clinical practice. The Institute of Biomedical Chemistry (IBMC), consolidating the efforts of leading scientific and medical organizations, has achieved success in this area by developing a clinical blood metabogram (CBM). CBM opens opportunities to obtain overview on the state of the body with the detailed individual metabolic characteristics of the patient. A number of scientific studies have shown that the CBM is an effective tool for monitoring the state of the body, and based on the CBM patterns (signatures), it is possible to diagnose and monitor the treatment of many diseases. Today, the CBM creation determines the current state and prospects of clinical metabolomics in Russia. This article, dedicated to the 80th anniversary of IBMC, is a review of these achievements focused on a discussion of their implementation in clinical practice.
Currently, there is great interest in the development of highly sensitive bioanalytical systems for diagnosing diseases at an early stage, when pathological biomarkers are present in biological fluids at low concentrations and there are no clinical manifestations. A promising direction is the use of molecular detectors―highly sensitive devices that detect signals from single biomacromolecules. A typical detector in this class is the atomic force microscope (AFM). The high sensitivity of an AFM-based bioanalysis system is determined by the size of the sensing element of an atomic force microscope―the cantilever―the radius of the curvature of which is comparable to that of a biomolecule. Biospecific molecular probe–target interactions are used to ensure detection system specificity. Antibodies, aptamers, synthetic antibodies, and peptides can be used as molecular probes. This study has demonstrated the possibility of using aptamers as molecular probes for AFM-based detection of the ovarian cancer biomarker CA125. Antigen detection in a nanomolar solution was carried out using AFM chips with immobilized aptamers, commercially available or synthesized based on sequences from open sources. Both aptamer types can be used for antigen detection, but the availability of sequence information enables additional modeling of the aptamer structure with allowance for modifications necessary for immobilization of the aptamer on an AFM chip surface. Information on the structure and oligomeric composition of aptamers in the solution was acquired by combining small-angle X-ray scattering and molecular modeling. Modeling enabled pre-selection, before the experimental stage, of aptamers for use as surface-immobilized molecular probes.
Early diagnostics significantly improves the survival of patients with renal cell carcinoma (RCC), which is the prevailing type of adult kidney cancer. However, the absence of clinically obvious symptoms and effective screening strategies at the early stages result to disease progression and survival rate reducing. The study was focused on revealing of potential low molecular biomarkers for early-stage RCC. The untargeted direct injection mass spectrometry-based metabolite profiling of blood plasma samples from 51 non-cancer volunteers (control) and 78 patients with different RCC subtypes and stages (early stages of clear cell RCC (ccRCC), papillary RCC (pRCC), chromophobe RCC (chrRCC) and advanced stages of ccRCC) was performed. Comparative analysis of the blood plasma metabolites between the control and cancer groups provided the detection of metabolites associated with different tumor stages. The designed model based on the revealed metabolites demonstrated high diagnostic power and accuracy. Overall, using the metabolomics approach the study revealed the metabolites demonstrating a high value for design of plasma-based test to improve early ccRCC diagnosis.
Oncological changes in the prostate are a common cause of death among elderly men. Malignant cells are difficult to identify at early stages, which are asymptomatic. The patient often seeks medical assistance when the disease has already progressed, and the treatment is less effective. Early diagnosis of prostate cancer (PC) is thus one of the priority tasks of modern urology and healthcare in general. The aim of this study is the detection of microRNAs (miRNAs), which are known to be associated with PC. The detection of the target miRNAs in human plasma samples has been performed with a nanoribbon biosensor system, which was based on "silicon-on-insulator" structures (SOI-NR biosensor). In order to provide biospecific detection of the target miRNAs, the surface of individual nanoribbons has been modified with DNA oligonucleotide probes (oDNA probes), whose nucleotide sequences were complementary to those of the target miRNAs. The high detection sensitivity has been demonstrated with the use of model oDNAs, which are complementary to nanoribbon-immobilized oDNA probes, in buffer solutions. The sensitivity threshold was 1.1 × 10-17 M. The successful detection of target miRNAs, isolated from real plasma samples of PC patients, has also been demonstrated. We believe that the development of highly sensitive nanotechnology-based biosensors for PC markers is a step towards personalized medicine.
Recently, the concept of a mass spectrometric blood metabogram was introduced, which allows the analysis of the blood metabolome in terms of the time, cost, and reproducibility of clinical laboratory tests. It was demonstrated that the components of the metabogram are related groups of the blood metabolites associated with humoral regulation; the metabolism of lipids, carbohydrates, and amines; lipid intake into the organism; and liver function, thereby providing clinically relevant information. The purpose of this work was to evaluate the relevance of using the metabogram in a disease. To do this, the metabogram was used to analyze patients with various degrees of metabolic alterations associated with obesity. The study involved 20 healthy individuals, 20 overweight individuals, and 60 individuals with class 1, 2, or 3 obesity. The results showed that the metabogram revealed obesity-associated metabolic alterations, including changes in the blood levels of steroids, amino acids, fatty acids, and phospholipids, which are consistent with the available scientific data to date. Therefore, the metabogram allows testing of metabolically unhealthy overweight or obese patients, providing both a general overview of their metabolic alterations and detailing their individual characteristics. It was concluded that the metabogram is an accurate and clinically applicable test for assessing an individual's metabolic status in disease.