We present a systematic experimental investigation of temporal contrast enhancement techniques for petawatt (PW)-class Ti:sapphire lasers utilizing a double chirped-pulse amplification (CPA) architecture. Particular attention is given to pre-pulses induced by post-pulses originating in the first CPA stage. One conventional and two advanced pulse-cleaning strategies are quantitatively evaluated: (i) a saturable absorber (SA), (ii) a femtosecond optical parametric amplifier (OPA) employing the idler pulse in a two-stage configuration, and (iii) sum-frequency generation (SFG) combining the signal and idler pulses from the OPA. All techniques are implemented and evaluated using the J-KAREN-P laser system with an output energy of about 20 J. To the best of our knowledge, this is the first report to directly and systematically compare the contrast of pre-pulses originating from the first CPA stage under identical experimental conditions in a high-energy PW-class laser facility. The results offer crucial insights into contrast optimization for future high-field applications.
Particle-in-Cell (PIC) method is a powerful plasma simulation tool for investigating high-intensity femtosecond laser-matter interaction. However, its simulation capability at high-density plasmas around the Fermi temperature is considered to be inadequate due, among others, to the necessity of implementing atomic-scale collisions. Here, we performed a one-dimensional with three-velocity space (1D3V) PIC simulation that features the realistic collision frequency around the Fermi temperature and atomic-scale cell size. The results are compared with state-of-the-art experimental results as well as with hydrodynamic simulation. We found that the PIC simulation is capable of simulating the nanoscale dynamics of solid-density plasmas around the Fermi temperature up to ∼2 ps driven by a laser pulse at the moderate intensity of 10^14-15 W/cm^2, by comparing with the state-of-the-art experimental results. The reliability of the simulation can be further improved in the future by implementing multi-dimensional kinetics and radiation transport.
The generation of highly charged ions in laser plasmas is usually associated with collisional ionization processes that occur in electron–ion collisions. An alternative ionization channel caused by tunnel ionization in an optical field is also capable of effectively producing highly charged ions with ionization potentials of several kiloelectronvolts when the laser intensity q > 1020 W/cm2. It is challenging to clearly distinguish the impacts of the optical field and collisional ionizations on the evolution of the charge state of a nonequilibrium plasma produced by the interaction of high-intensity, ultrashort PW-class laser pulses with dense matter. In the present work, it is shown that the answer to this question can be obtained in some cases by observing the X-ray spectral lines caused by the transition of an electron into the K-shell of highly charged ions. The time-dependent calculations of plasma kinetics show that this is possible, for example, if sufficiently small clusters targets with low-density background gas are irradiated. In the case of Ar plasma, the limit of the cluster radius was estimated to be R0 = 0.1 μm. The calculation results for argon ions were compared with the results of the experiment at the J-KAREN-P laser facility at QST-KPSI.
We review a number of instruments employed in a high-intensity J-KAREN-P laser-solid interaction experiment and discuss the applicability of the diagnostics to the best target position determination with a ~10 μm accuracy, while the focal spot size was ~1 μm and peak intensity was up to 7×1021 W/cm2. We discuss both front- and back-side diagnostics, some of them operated in the infrared, visible and ultraviolet ranges, while others in the extreme ultraviolet, soft X-ray and gamma-ray ranges. We found that the applicability of some of the instruments to the best at-focus target position determination depends on the thickness of the target.
Ultrafast optical probing is a widely used method of underdense plasma diagnostic. In relativistic plasma, the motion blur limits spatial resolution in the direction of motion. For many high-power lasers the initial pulse duration of 30-50 fs results in a 10-15 μm motion blur, which can be reduced by probe pulse post-compression. Here we used the Compression after Compressor Approach (CafCA) [Phys.-Usp. 62, 1096 (2019); JINST 17 P07035 (2022)], where spectral broadening is performed in thin optical plates and is followed by reflections from negative-dispersion mirrors. Our initially low-fluence probe beam was down-collimated for a more efficient spectral broadening and higher probe-to-self-emission intensity ratio. The setup is compact, fits in vacuum chamber, and can be implemented within a short experimental time slot. We proved that the compressed pulse kept high quality necessary for plasma probing. We also characterized the probe compression dependence on the main pulse energy when the latter was increased by a factor of larger than 5 while the compression setup was not changed.
We described the output performance and temporal quality enhancement of the J-KAREN-P petawatt laser facility. After wavefront correction using a deformable mirror, focusing with an f/1.3 off-axis parabolic mirror delivered a peak intensity of 1022 W/cm2 at 0.3 PW power levels. Technologies to improve the temporal contrast were investigated and tested. The origins of pre-pulses generated by post-pulses were identified and the elimination of most pre-pulses by removal of the post-pulses with wedged optics was achieved. A cascaded femtosecond optical parametric amplifier based on the utilization of the idler pulse rather than the signal pulse was developed for the complete elimination of the remaining pre-pulses. The orders of magnitude enhancement of the pedestal before the main pulse were obtained by using a higher surface quality of the convex mirror in the Öffner stretcher. A single plasma mirror was installed in the J-KAREN-P laser beam line for further contrast improvement of three orders of magnitude. The above developments indicate, although it has not been directly measured, the contrast can be as high as approximately 1015 up to 40 ps before the main pulse. We also showed an overview of the digital transformation (DX) of the system, enabling remote and automated operation of the J-KAREN-P laser facility.
Tight focusing with very small f-numbers is necessary to achieve highest at-focus irradiances. However, tight focusing also means short Rayleigh length, which imposes strong demands on the precise positioning of the target at the best focus to achieve the highest on-target irradiance. We describe several near-infrared, visible, ultraviolet, soft and hard X-ray diagnostics employed in the ~10^22 W/cm2 laser-plasma experiment at the J-KAREN-P laser facility in KPSI, Japan. The experiment requires a tight focusing of ~10 J femtosecond infrared laser pulses into ~1.3-µm-diameter focal spots on stainless steel (SUS) solid targets of different thicknesses (5–20 µm). We discuss the applicability of these diagnostics to determine the best in-focus position of the target with <10 µm accuracy (i. e., within the short Rayleigh length) in high-power laser-matter experiments, and suggest which diagnostics should and which ones should not be used for this purpose. It was demonstrated that the target could be positioned to within few µm out of the best laser focus, ensuring over 80% of the ideal peak intensity.
Laser-driven ion sources are a rapidly developing technology producing high energy, high peak current beams. Their suitability for applications, such as compact medical accelerators, motivates development of robust acceleration schemes using widely available repetitive ultraintense femtosecond lasers. These applications not only require high beam energy, but also place demanding requirements on the source stability and controllability. This can be seriously affected by the laser temporal contrast, precluding the replication of ion acceleration performance on independent laser systems with otherwise similar parameters. Here, we present the experimental generation of > 60 MeV protons and > 30 MeV u −1 carbon ions from sub-micrometre thickness Formvar foils irradiated with laser intensities > 10 21 Wcm 2 . Ions are accelerated by an extreme localised space charge field ≳30 TVm −1 , over a million times higher than used in conventional accelerators. The field is formed by a rapid expulsion of electrons from the target bulk due to relativistically induced transparency, in which relativistic corrections to the refractive index enables laser transmission through normally opaque plasma. We replicate the mechanism on two different laser facilities and show that the optimum target thickness decreases with improved laser contrast due to reduced pre-expansion. Our demonstration that energetic ions can be accelerated by this mechanism at different contrast levels relaxes laser requirements and indicates interaction parameters for realising application-specific beam delivery.
We present a method extending scanning third-order correlator temporal pulse evolution measurement capabilities of high power short pulse lasers to spectral sensitivity within the spectral range exploited by typical chirped pulse amplification systems. Modelling of the spectral response achieved by angle tuning of the third harmonic generating crystal is applied and experimentally validated. Exemplary measurements of spectrally resolved pulse contrast of a Petawatt laser frontend illustrate the importance of full bandwidth coverage for the interpretation of relativistic laser target interaction in particular for the case of solid targets.
We report on the design and characterization of the plasma mirror system installed on the J-KAREN-P laser at the Kansai Photon Science Institute, National Institutes for Quantum Science and Technology. The reflectivity of the single plasma mirror system exceeded 80%. In addition, the temporal contrast was improved by two orders of magnitude at 1 ps before the main pulse. Furthermore, the laser near-field spatial distribution after the plasma mirror was kept constant at plasma mirror fluence of less than 100 kJ/cm(2). We also present the results of investigating the difference and the fluctuation in energy, pulse width and pointing stability with and without the plasma mirror system.
Observing ultrafast laser-induced structural changes in nanoscale systems is essential for understanding the dynamics of intense light-matter interactions. For laser intensities on the order of 10^14 W/cm^2, highly-collisional plasmas are generated at and below the surface. Subsequent transport processes such as heat conduction, electron-ion thermalization, surface ablation and resolidification occur at picosecond and nanosecond time scales. Imaging methods, e.g. using x-ray free-electron lasers (XFEL), were hitherto unable to measure the depth-resolved subsurface dynamics of laser-solid interactions with appropriate temporal and spatial resolution. Here we demonstrate picosecond grazing-incidence small-angle x-ray scattering (GISAXS) from laser-produced plasmas using XFEL pulses. Using multi-layer (ML) samples, both the surface ablation and subsurface density dynamics are measured with nanometer depth resolution. Our experimental data challenges the state-of-the-art modeling of matter under extreme conditions and opens new perspectives for laser material processing and high-energy-density science.
We have realized the removal of most pre-pulses with wedged optics and orders of magnitude enhancement of the pedestal with higher optical quality optics. We have successfully installed the plasma mirror system for further improvement.
Irradiation effects of poly( methyl methacrylate) (PMMA) induced by femtosecond-pulsed extreme ultraviolet (EUV) were investigated using Soft X-ray free electron laser (SXFEL) for realization of next generation extreme ultraviolet free electron laser (EUV-FEL) lithography. The sensitivity of PMMA upon exposure to femtosecond-pulsed SXFEL was much higher than that measured for conventional nanosecond-pulsed EUV source. The sensitivity enhancement upon exposure to femtosecond-pulsed SXFEL is similar to the result obtained using laser-induced-plasma based Soft X-ray laser (SXRL) (picosecond-pulsed EUV). This result speculates the reactions induced by femtosecond-pulsed SXFEL and picosecond-pulsed XRL were almost same, but it was different from those induced by nanosecond-pulsed EUV.
Although laser irradiation with femtosecond pulses is known to generate crystallization and morphological changes, the contribution of optical parameters to material changes is still in discussion. Here, we compare two structures irradiated near Si-L2,3 edges by an extreme ultraviolet femtosecond pulse. Our result implies that, despite the femtosecond irradiation regime, these values of the optical attenuation length between the wavelengths of 10.3-nm and 13.5-nm differ by one order of magnitude. From the structural comparison, the original crystalline state was maintained upon irradiation at 13.5-nm, on the other hand, transition to an amorphous state occurred at 10.3-nm. The difference in optical attenuation length directly influence to the decision of material crystallization or morphological changes, even if the irradiation condition is under the femtosecond regime and same pulse duration. Our result reveals the contribution of optical attenuation length in ultrafast laser-induced structural change.