We present our photometric and spectroscopic observations of the peculiar transient AT2018cow. The multiband photometry covers from peak to similar to 70 days, and the spectroscopy ranges from 5 to similar to 50 days. The rapid rise (t(r) less than or similar to 2.9 days), high luminosity (M-V,M-peak similar to -20.8 mag), and fast decline after peak make AT2018cow stand out from any other optical transients, whereas we find that its light curves show a high resemblance to those of Type Ibn supernovae. Moreover, the spectral energy distribution remains at a high temperature of similar to 14,000 K at t > 15 days after discovery. The spectra are featureless in the first 10 days, while some broad emission lines due to H, He, C, and O emerge later, with velocity declining from similar to 14,000 to similar to 3000 km s(-1) at the end of our observations. Narrow and weak He I emission lines emerge in the spectra at t > 20 days after discovery. These emission lines are reminiscent of the features seen in interacting supernovae like the Type Ibn and IIn subclasses. We fit the bolometric light curves with a model of circumstellar interaction and radioactive decay of Ni-56 and find a good fit with ejecta mass M-ej similar to 3.16 M<sub, circumstellar medium (CSM) mass M-CSM similar to 0.04 M, and ejected Ni-56 mass M. The CSM shell might be formed in an eruptive mass ejection of the progenitor star. Furthermore, the host environment of AT2018cow implies a connection of AT2018cow with massive stars. Combining observational properties and the light-curve fitting results, we conclude that AT2018cow might be a peculiar interacting supernova that originated from a massive star.
BackgroundGeant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro‐ and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing.AimsTo respond to these needs, we developed G4‐Med, a benchmarking and regression testing system of Geant4 for medical physics.Materials and MethodsG4‐Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4‐Med are executed on the CERN computing infrastructure via the use of the geant‐val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes.ResultsThis paper describes the tests included in G4‐Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.DiscussionOur results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics.ConclusionThe results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.
2I/Borisov is the first interstellar comet discovered on 2019 August 30, and it soon showed a coma and a dust tail. This study reports the results of images obtained at the Telescopio Nazionale Galileo telescope, on La Palma—Canary Islands, in 2019 November and December. The images have been obtained with the R filter in order to apply our dust tail model. The model has been applied to the comet 67P/Churyumov–Gerasimenko and compared to the Rosetta dust measurements showing a very good agreement. It has been applied to the comet 2I/Borisov, using almost the same parameters, obtaining a dust environment similar to that of 67P/Churyumov–Gerasimenko, suggesting that the activity may be very similar. The dust tail analysis provided a dust-loss rate Qd ≈ 35 kg s−1 in 2019 November and Qd ≈ 30 kg s−1 in 2019 December.
Since its discovery in 2008, the Andromeda galaxy nova M31N 2008-12a has been observed in eruption every single year. This unprecedented frequency indicates an extreme object, with a massive white dwarf and a high accretion rate, which is the most promising candidate for the single-degenerate progenitor of a Type Ia supernova known to date. The previous three eruptions of M31N 2008-12a have displayed remarkably homogeneous multiwavelength properties: (i) from a faint peak, the optical light curve declined rapidly by two magnitudes in less than two days, (ii) early spectra showed initial high velocities that slowed down significantly within days and displayed clear He/N lines throughout, and (iii) the supersoft X-ray source (SSS) phase of the nova began extremely early, six days after eruption, and only lasted for about two weeks. In contrast, the peculiar 2016 eruption was clearly different. Here we report (i) the considerable delay in the 2016 eruption date, (ii) the significantly shorter SSS phase, and (iii) the brighter optical peak magnitude (with a hitherto unobserved cusp shape). Early theoretical models suggest that these three different effects can be consistently understood as caused by a lower quiescence mass accretion rate. The corresponding higher ignition mass caused a brighter peak in the free–free emission model. The less massive accretion disk experienced greater disruption, consequently delaying the re-establishment of effective accretion. Without the early refueling, the SSS phase was shortened. Observing the next few eruptions will determine whether the properties of the 2016 outburst make it a genuine outlier in the evolution of M31N 2008-12a.
We present a photometric detection of the first brightness dips of the unique variable star KIC 8462852 since the end of the Kepler space mission in 2013 May. Our regular photometric surveillance started in October 2015, and a sequence of dipping began in 2017 May continuing on through the end of 2017, when the star was no longer visible from Earth. We distinguish four main 1-2.5 dips, named "Elsie," "Celeste," "Skara Brae," and "Angkor", which persist on timescales from several days to weeks. Our main results so far are: (i) there are no apparent changes of the stellar spectrum or polarization during the dips; (ii) the multiband photometry of the dips shows differential reddening favoring non-grey extinction. Therefore, our data are inconsistent with dip models that invoke optically thick material, but rather they are in-line with predictions for an occulter consisting primarily of ordinary dust, where much of the material must be optically thin with a size scale <<1um, and may also be consistent with models invoking variations intrinsic to the stellar photosphere. Notably, our data do not place constraints on the color of the longer-term "secular" dimming, which may be caused by independent processes, or probe different regimes of a single process.
We describe the recent inclusion in Geant4 of state-of-the-art proton and alpha particle shell ionisation cross sections based on the ECPSSR approach as calculated by Cohen et al., called here ANSTO ECPSSR. The new ionisation cross sections have been integrated into Geant4. We present a comparison of the fluorescence X-ray spectra generated by the ANSTO ECPSSR set of cross sections and, alternatively, the currently available sets of Geant4 PIXE cross sections. The comparisons are performed for a large set of sample materials spanning a broad range of atomic numbers. The two alternative PIXE cross sections approaches (Geant4 and ANSTO) have been compared to existing experimental measurements performed at ANSTO with gold, tantalum and cerium targets of interest for nanomedicine applications. The results show that, while the alternative approaches produce equivalent results for vacancies generated in the K and L shell, differences are evident in the case of M shell vacancies. This work represents the next step in the effort to improve the Geant4 modelling of the atomic relaxation and provide recommended approaches to the Geant4 user community. This new Geant4 development is of interest for applications spanning from life and space to environmental science.
A revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.
The general purpose Geant4 Monte Carlo simulation toolkit is able to simulate radiative and non-radiative atomic de-excitation processes such as fluorescence and Auger electron emission, occurring after interaction of incident ionising radiation with target atomic electrons. In this paper, we evaluate the Geant4 modelling capability for the simulation of fluorescence spectra induced by 1.5MeV proton irradiation of thin high-Z foils (Fe, GdF3, Pt, Au) with potential interest for nanotechnologies and life sciences. Simulation results are compared to measurements performed at the Centre d’Etudes Nucléaires de Bordeaux-Gradignan AIFIRA nanobeam line irradiation facility in France. Simulation and experimental conditions are described and the influence of Geant4 electromagnetic physics models is discussed.