The Geant4 International User Conference at the Physics-Medicine-Biology Frontier is a conference series for Geant4 and Geant4-DNA users working in medical physics, radiation protection from environmental and space radiation, radiation biology, and related fields. Organized under the auspices of the Geant4 Collaboration (https://geant4.org), the series provides an opportunity for developers and users of Geant4 and Geant4-based tools to regularly gather and discuss recent advances. The fifth meeting in this series, the 5th Geant4 International User Conference at the Physics-Medicine-Biology Frontier (https://indico.rcnp.osaka-u.ac.jp/event/2096/overview), was held at the University of Osaka Nakanoshima Center, Japan, from 27 to 29 March 2024. Participants were invited to submit original articles for peer review in a special issue of Physica Medica (V Geant4 International User Conference Invited Papers: https://www.sciencedirect.com/special-issue/100KLKWDPF0), the European Journal of Medical Physics, which was fully dedicated to the event. Nine of the research projects presented at the conference were selected for publication. This introductory article provides an overview of the nine research papers included in this special issue, each offering unique perspectives and significant advancements to the overarching theme of the conference.
Advances in scintillation crystal and silicon photomultiplier (SiPM) technologies have enabled the development of compact, lightweight, and low-power radiation detectors that are suitable for integration with unmanned aerial vehicles (UAVs). This integration enables efficient and cost-effective large-area radiation monitoring while minimizing occupational exposure. In this work, a SiPM-based NaIL scintillation detection payload was developed, characterized, and mounted on a multirotor UAV for ground-level radioactivity mapping, gamma-ray and neutron source localization, and activity estimation applications. To support these capabilities, an analytic radionuclide detection efficiency model was developed and used to estimate radioactivity on the ground from aerial energy spectrum measurements. The analytic expression for the detection efficiency incorporated physical phenomena, including the branching ratio, detector solid angle, air attenuation, and intrinsic peak efficiency, leading to agreement within 10% of experimental radionuclide detection efficiencies. The UAV-based radiation detection system was physically validated through a controlled indoor live radioactive source demonstration at 1.5, 3, and 4.5 m flight heights. Using the developed ground-level radioactivity estimation method, Cs-137 and Co-60 sources were successfully localized within 0.5 m, and their activities were estimated with errors on the order of 10% or less.
Track structure particle and radiation physics models have been increasingly used to understand DNA damage by radiation and to perform in silico microdosimetry and nanodosimetry calculations. The open source Monte Carlo toolkit Geant4-DNA allows for the simulation of physical and chemical interactions in realistic cell geometries at nano- and microscales. To improve the applicability of Geant4-DNA to support space radiobiology, the energy ranges and particle types available for simulation have been extended by implementing a new physics model set inside Geant4-DNA. Ionisation and excitation models for protons and ions have been developed for energies between 100keV/u and 1TeV/u. Additionally, ionisation, excitation and Bremsstrahlung models have been implemented for electrons, allowing simulation from 7eV to 100MeV. These have been incorporated into a physics list, CosmicDNA, which has been benchmarked with respect to the stopping power, range and radial distribution of dose in liquid water. As a result of the models implemented, the simulated stopping powers of protons and ions in molecular water have better agreement with ICRU recommendations by over 18% above 100MeV/u. This new physics model set will be implemented in a subsequent release of Geant4 and will be revised with improved models as they become available.
Neutron Activation Analysis (NAA) is a technique based on gamma rays emitted from neutron-nucleus interactions. Such interactions are unique for each element and isotope, and the measured gamma spectrum can identify the atomic composition of the target object. This proof-of-concept study explores the possibility of adding spatial information to NAA by employing ghost imaging (GI). In this article, the TOPAS Monte-Carlo particle simulation tool was utilised to simulate the potential deployment of GI at ANSTO’s DINGO neutron imaging beamline. In TOPAS the DINGO beamline was implemented to include the neutron source, collimator, and detector with an additional gamma-ray sensor. A GI experiment using a randomly structured Cd mask to pattern the neutron illumination was then simulated for 41 different mask positions. GI reconstruction enabled visualisation of the gold distribution in a test object. The simulation serves as a demonstration of the principle, and a means to better understand the appropriate experimental scenarios and acquisition times to successfully realise prompt-gamma GI in practice.
The use of mobile robotics in radioactive source seeking has become an important part of modern radiation-safety practices, supporting timely mitigation of contamination risks and helping protect public health. However, measuring radiation is often time-consuming, rendering traditional gradient-based source-seeking methods less effective due to lower sample efficiency. This paper proposes a sample-efficient Bayesian-Optimisation source-seeking strategy that utilises a heteroscedastic Gaussian process surrogate to balance exploration and exploitation. Excessive inter-sample travel is discouraged through a movement switching cost. The strategy is shown to generate sublinear regret in the source-seeking task, while simulations demonstrate its effectiveness in localising radioactive sources.
The early DNA damage on the surface of the Moon due to GCR protons and alpha particles were assessed using a multiscale approach in Geant4. This consisted of three simulation stages. A periodic boundary conditions approach was used to obtain the radiation field on the surface and inside a proposed lunar habitat. The radiation field on the cellular scale was obtained in the organs of male and female astronauts using the ICRP145 tetrahedral mesh phantoms. This was subsequently simulated using a full human cell model in Geant4-DNA to obtain the early DNA damage. Geant4-DNA track structure ionisation models upper energy limits were extended to be able to model the interactions of the GCR at sub-cellular level, covering an energy range from a few eV up to 1TeV. Hadronic interactions and the modelling of induced radiochemical species were also implemented. The early DNA damage was assessed using the Geant4-DNA molecularDNA example. A greater yield of DNA damage was observed on the lunar surface compared with the habitat, and indirect damage due to induced hydroxyl radicals constituted most of the damage. This study demonstrates a complete simulation pipeline for the assessment of early DNA damage in astronauts in the space radiation environment.
Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. In this work, we describe the evolution of the G4-Med benchmarking system. The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I $^{125}I$ source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study ( G4EmLivermorePhysics , G4EmStandardPhysics_option3 , and G4EmStandardPhysics_option4 ). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4 , for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.
We present a method to shape a neutron beam and project any specified target image using a single universal patterned mask that is transversely displaced. The method relies on “ghost projection”, which is a reversed form of classical ghost imaging. A set of sub-mask regions that combine to construct the required beam shape is computed; illumination of each region with the determined exposure time projects the shaped beam. We demonstrate this method experimentally, using the Dingo neutron imaging beamline at the OPAL nuclear research reactor (Australia). The ability to shape a neutron beam “on demand” allows selective dose delivery away from sensitive areas of samples, such as in cultural heritage artifacts. It also benefits irradiation techniques, e.g., in testing resilience of electronic components for space and defense technologies or neutron therapies.
Background and purpose: Understanding the cellular and molecular effect of proton radiation, particularly the increased DNA damage complexity at the distal end of the Bragg curve, is current topic of investigation. This work aims to study in vitro clonogenic survival and DNA damage foci kinetics of a head and neck squamous cell carcinoma cell line at various positions along a double passively scattered Bragg curve. Complementary in silico studies are conducted to gain insights into the link between cell survival variations, experimentally yielded foci and the number and complexity of double strand breaks (DSBs). Materials and methods: Proton irradiations are performed at the HollandPTC R&D proton beamline, using a double passively scattered setup. A custom water phantom setup is employed to accurately position the samples within the Bragg curve. FaDu cells are irradiated at the proximal 36 % point of the Bragg peak, (P36), proximal 80 % point of the Bragg peak (P80) and distal 20 % point of the Bragg peak (D20), with dose-averaged mean lineal energies (yD) of 1.10 keV/mu m, 1.80 keV/mu m and 7.25 keV/mu m, respectively. Results: Clonogenic survival correlates strongly with y D , showing similar survival for P36 (D37%=3.0 Gy) and P80 (D37%=2.9 Gy), but decreased survival for D20 (D 37% = 1.6 Gy). D20 irradiated samples exhibit increased 53BP1 foci shortly after irradiation, slower resolution of the foci, and larger residual 53BP1 foci after 24 h, indicating unrepaired complex breaks. These experimental observations are supported by the in silico study which demonstrates that irradiation at D20 leads to a 1.7-fold increase in complex DSBs with respect to the total number of strand breaks compared to P36 and P80. Conclusions: This combined approach provides valuable insights into the cellular and molecular effect of proton radiation, emphasizing the increased DNA damage complexity at the distal end of the Bragg curve, and has the potential to enhance the efficacy of proton therapy.
Radiation detection is vital for space, medical imaging, homeland security, and environmental monitoring applications. In the past, the Monte Carlo radiation transport toolkit, Geant4, has been employed to enable the effective development of emerging technologies in these fields. Radiation detectors utilising scintillator crystals have benefited from Geant4; however, Geant4 optical physics parameters for scintillator crystal modelling are sparse. This work outlines scintillator properties for GAGG:Ce, CLLBC:Ce, BGO, NaI:Tl, and CsI:Tl. These properties were implemented in a detailed SiPM-based single-volume scintillation detector simulation platform developed in this work. It was validated by its comparison to experimental measurements. For all five scintillation materials, the platform successfully predicted the spectral features for selected gamma ray emitting isotopes with energies between 30 keV to 2 MeV. The full width half maximum (FWHM) and normalised cross-correlation coefficient (NCCC) between simulated and experimental energy spectra were also compared. The majority of simulated FWHM values reproduced the experimental results within a 2% difference, and the majority of NCCC values demonstrated agreement between the simulated and experimental energy spectra. Discrepancies in these figures of merit were attributed to detector signal processing electronics modelling and geometry approximations within the detector and surrounding experimental environment.
BackgroundGeant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5.PurposeIn this work, we describe the evolution of the G4-Med benchmarking system.MethodsThe G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125I$<^>{125}I$ source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times.ResultsIn summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard-Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment.ConclusionsBased on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.
HollandPTC is an independent outpatient center for proton therapy, scientific research, and education. Patients with different types of cancer are treated with Intensity Modulated Proton Therapy (IMPT). Additionally, the HollandPTC R&D consortium conducts scientific research into the added value and improvements of proton therapy. To this end, HollandPTC created clinical and pre-clinical research facilities including a versatile R&D proton beamline for various types of biologically and technologically oriented research. In this work, we present the characterization of the R&D proton beamline of HollandPTC. Its pencil beam mimics the one used for clinical IMPT, with energy ranging from 70 up to 240 MeV, which has been characterized in terms of shape, size, and intensity. For experiments that need a uniform field in depth and lateral directions, a dual ring passive scattering system has been designed, built, and characterized. With this system, field sizes between 2 × 2 cm2 and 20 × 20 cm2 with 98 % uniformity are produced with dose rates ranging from 0.5 Gy/min up to 9 Gy/min. The unique and customized support of the dual ring system allows switching between a pencil beam and a large field in a very simple and fast way, making the HollandPTC R&D proton beam able to support a wide range of different applications.
A chemistry module has been implemented in Geant4-DNA since Geant4 version 10.1 to simulate the radiolysis of water after irradiation. It has been used in a number of applications, including the calculation of G-values and early DNA damage, allowing the comparison with experimental data. Since the first version, numerous modifications have been made to the module to improve the computational efficiency and extend the simulation to homogeneous kinetics in bulk solution. With these new developments, new applications have been proposed and released as Geant4 examples, showing how to use chemical processes and models. This work reviews the models implemented and application developments for modeling water radiolysis in Geant4-DNA as reported in the ESA BioRad III Project.
The authors regret having incorrectly written in equation (7) that the fraction of surviving cells (SF) is obtained using the natural logarithm of the negative value of the number of lethal lesions Lf. The natural logarithm must be replaced by the exponential function as follows:SF=exp(-Lf)(7) Although the equation is incorrectly written in the paper, its correct expression has been used in the results of the analysis shown in Figure 4. This error has no impact on the other results and conclusions of the paper. The authors would like to apologise for any inconvenience caused. Prediction of DNA rejoining kinetics and cell survival after proton irradiation for V79 cells using Geant4-DNAPhysica Medica: European Journal of Medical PhysicsVol. 105PreviewTrack structure Monte Carlo (MC) codes have achieved successful outcomes in the quantitative investigation of radiation-induced initial DNA damage. The aim of the present study is to extend a Geant4-DNA radiobiological application by incorporating a feature allowing for the prediction of DNA rejoining kinetics and corresponding cell surviving fraction along time after irradiation, for a Chinese hamster V79 cell line, which is one of the most popular and widely investigated cell lines in radiobiology. Full-Text PDF Open Access
The scientific community has a large interest in the studies of DNA damage and response after exposure to ionizing radiation. Several in-silico methods have been proposed so far to model and study the mechanisms of DNA damage using Monte Carlo simulations. The “molecularDNA” example is one of the most recent applications to simulate the irradiation of human cancer cells and bacteria using Geant4-DNA. This example enables the simulation of the physical, physico-chemical and chemical stages of liquid water irradiation, including radiolytic processes following the particle irradiation of the pre-defined human cell geometries and it can be used to calculate the early direct and non-direct DNA damage such as single (SSB) and double strand breaks (DSB) as well as DNA fragment distribution. The application is user friendly and can be used following simple macro commands. The results of the Monte Carlo simulation are compared to experimental data of DSB yields, as well as with previously published simulation data.
The scientific community shows a great interest in the study of DNA damage induction, DNA damage repair and the biological effects on cells and cellular systems after exposure to ionizing radiation. Several in-silico methods have been proposed so far to study these mechanisms using Monte Carlo simulations. This study outlines a Geant4-DNA example application, named "molecularDNA", publicly released in the 11.1 version of Geant4 (December 2022). It was developed for novice Geant4 users and requires only a basic understanding of scripting languages to get started. The example currently proposes two different DNA-scale geometries of biological targets, namely "cylinders", and the "human cell". This public version is based on a previous prototype and includes new features such as: the adoption of a new approach for the modeling of the chemical stage (IRT-sync), the use of the Standard DNA Damage (SDD) format to describe radiation-induced DNA damage and upgraded computational tools to estimate DNA damage response. Simulation data in terms of single strand break (SSB) and double strand break (DSB) yields were produced using each of these geometries. The results were compared to the literature, to validate the example, producing less than 5 % difference in all cases.
Purpose: This study aimed to develop a computational environment for the accurate simulation of human cancer cell irradiation using Geant4-DNA. New cell geometrical models were developed and irradiated by alpha particle beams to induce DNA damage. The proposed approach may help further investigation of the benefits of external alpha irradiation therapy. Methods: The Geant4-DNA Monte Carlo (MC) toolkit allows the simulation of cancer cell geometries that can be combined with accurate modelling of physical, physicochemical and chemical stages of liquid water irradiation, including radiolytic processes. Geant4-DNA is used to calculate direct and non-direct DNA damage yields, such as single and double strand breaks, produced by the deposition of energy or by the interaction of DNA with free radicals. Results: In this study, the "molecularDNA"example application of Geant4-DNA was used to quantify early DNA damage in human cancer cells upon irradiation with alpha particle beams, as a function of linear energy transfer (LET). The MC simulation results are compared to experimental data, as well as previously published simulation data. The simulation results agree well with the experimental data on DSB yields in the lower LET range, while the experimental data on DSB yields are lower than the results obtained with the "molecularDNA"example in the higher LET range. Conclusion: This study explored and demonstrated the possibilities of the Geant4-DNA toolkit together with the "molecularDNA"example to simulate the helium beam irradiation of cancer cell lines, to quantify the early DNA damage, or even the following DNA damage response.
PURPOSE:Track structure Monte Carlo (MC) codes have achieved successful outcomes in the quantitative investigation of radiation-induced initial DNA damage. The aim of the present study is to extend a Geant4-DNA radiobiological application by incorporating a feature allowing for the prediction of DNA rejoining kinetics and corresponding cell surviving fraction along time after irradiation, for a Chinese hamster V79 cell line, which is one of the most popular and widely investigated cell lines in radiobiology. METHODS:We implemented the Two-Lesion Kinetics (TLK) model, originally proposed by Stewart, which allows for simulations to calculate residual DNA damage and surviving fraction along time via the number of initial DNA damage and its complexity as inputs. RESULTS:By optimizing the model parameters of the TLK model in accordance to the experimental data on V79, we were able to predict both DNA rejoining kinetics at low linear energy transfers (LET) and cell surviving fraction. CONCLUSION:This is the first study to demonstrate the implementation of both the cell surviving fraction and the DNA rejoining kinetics with the estimated initial DNA damage, in a realistic cell geometrical model simulated by full track structure MC simulations at DNA level and for various LET. These simulation and model make the link between mechanistic physical/chemical damage processes and these two specific biological endpoints.
CLLBC(Ce) and TLYC(Ce) are novel scintillation materials capable of measuring mixed gamma ray and neutron radiation fields that have gained significant interest in the areas of space and nuclear safety/security science. To date Geant4, the world’s most popular Monte Carlo radiation modelling toolkit, has yet to be effectively used to simulate the full response of these materials when coupled to near ultra-violet Silicon PhotoMultipliers (SiPMs). In this work an experimentally validated Geant4 application has been developed with optimised material composition, optical data tables, and physics transport settings that is able to accurately simulate the response of CLLBC(Ce) and TLYC(Ce) SiPM-based radiation detectors under both gamma ray and neutron irradiation. Experimental benchmarking for five different radioactive sources (Co-60, Cs-137, Eu-152, Am-241, and Cf-252) illustrated that this developed Geant4 application was able to reproduce the position and structure of all major spectral features (full energy gamma ray photo-/neutron capture peaks, X-ray escape photopeaks, Compton edge, Compton backscatter peaks, and Compton plateau) to high level of accuracy.