Development towards the various realizations of the FCC machine requires optimization of sub-GHz elliptical cavities for high-gradient and high-Q operation, both in pulsed and CW mode, for application in the booster and collider portions. Previous development work validated the proposed 800 MHz 5-cell elliptical RF design, showing reasonable performance after EP treatment. However, the stringent high-Q (3.8e+10) and high-gradient (24 MV/m) goals of the FCC machine cavities will require further development, relying on advanced surface processing techniques developed at 1.3 GHz, such as medium-temperature furnace baking. We describe the development and preparation of 1- and 5- cell 800 MHz cavities for the high-Q program. In parallel, we discuss the design progress and strategies for integrating the 800 MHz cavities into cryomodules to be implemented in both the booster and collider rings.
Niobium films are a key component in modern two-dimensional superconducting qubits, yet their contribution to the total qubit decay rate is not fully understood. The presence of different layers of materials and interfaces makes it difficult to identify the dominant loss channels in present two-dimensional qubit designs. In this paper, we present the study that directly correlates measurements of RF losses in such films to material parameters by investigating a high-power impulse magnetron sputtered (HiPIMS) film atop a three-dimensional niobium superconducting radio frequency (SRF) resonator. By using a 3D SRF structure, we are able to isolate the niobium film loss from other contributions. Our findings indicate that microwave dissipation in the HiPIMS-prepared niobium films, within the quantum regime, resembles that of record-high intrinsic quality factor of bulk niobium SRF cavities, with lifetimes extending into seconds. Microstructure and impurity level of the niobium film do not significantly affect the losses. These results set the scale of microwave losses in niobium films and show that niobium losses do not dominate the observed coherence times in present two-dimensional superconducting qubit designs, instead highlighting the dominant role of the dielectric oxide in limiting the performance. We can also set a bound for when niobium film losses will become a limitation for qubit lifetimes.
Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity. The cavity tested at 2 K in a vertical cryostat reached a superior accelerating field gradient of 53.3 MV/m at Q0 of 1.6x1010, which is the highest gradient attained for this type of large-sized cavities.
Nitrogen-doping and furnace-baking are advanced high-Q0 recipes developed for 1.3 GHz TESLA-type cavities. These treatments will significantly benefit the high-Q0 linear accelerator community if they can be successfully adapted to different cavity styles and frequencies. Strong frequency- and geometry- dependence of these recipes makes the technology transfer amongst different cavity styles and frequencies far from straightforward, and requires rigorous study. Upcoming high-Q0 continuous-wave linear accelerator projects, such as the proposed Michigan State University Facility for Rare Isotope Beam Energy Upgrade, and the underway Fermilab's Proton Improvement Plan-II, could benefit enormously from adapting these techniques to their beta_opt = 0.6 ~650 MHz 5-cell elliptical superconducting rf cavities, operating at an accelerating gradient of around ~17 MV/m. This is the first investigation of the adaptation of nitrogen doping and medium temperature furnace baking to prototype 644 MHz beta_opt = 0.65 cavities, with the aim of demonstrating the high-Q0 potential of these recipes in these novel cavities for future optimization as part of the FRIB400 project R&D. We find that nitrogen-doping delivers superior Q0, despite the sub-GHz operating frequency of these cavities, but is sensitive to the post-doping electropolishing removal step and experiences elevated residual resistance. Medium temperature furnace baking delivers reasonable performance with decreased residual resistance compared to the nitrogen doped cavity, but may require further recipe refinement. The gradient requirement for the FRIB400 upgrade project is comfortably achieved by both recipes.
Upcoming projects requiring high-Q0 ~650 MHz elliptical cavities, such as MSU’s Facility for Rare Isotope Beams’ energy upgrade and Fermilab’s PIP-II, drive a need to better understand RF losses due to magnetic flux. With sample sets from two different Niobium vendors, we explore the efficacy of the fast-cooldown method, and high- temperature annealing in promoting flux expulsion. Additionally, we report the results of vertical tests comparing the effect of electropolishing and furnace baking treatments on the cavity flux sensitivity. We also directly measure the flux pinning force in niobium samples, and correlate it with different heat treatments, and flux expulsion performance.
So-called two-level system (TLS) defects are among the most detrimental sources of loss and decoherence in superconducting quantum devices, and their microscopic nature still poorly understood. We develop a two-tone spectroscopy technique to characterize the spectral line width of TLS. This knowledge will help to distinguishes various types of TLS defects. In our experiments we use the fundamental TM010 pass band modes of 9-cell elliptical SRF cavities to probe spectral properties of TLS in native niobium oxide formed on the inside walls of the resonator. We pump one of the modes (4¿/9 through 8¿/9) with continuous high-power to saturate TLSs that couple to this frequency, and we probe the Q-factor of the ¿-mode. We observe increase of the quality factor of the probed ¿-mode when one of the neighboring modes is pumped. Extremely high quality factors of the pass band modes and their relative proximity in the frequency space allow us to estimate the width of the spectral hole burned in the TLS bath absorption spectrum which is related to the line spectral width of the TLS defects.
cavity surface area yielded a rough equator surface of the cavity. The grain step height on the equator weld position was measured to be ~ 32 μm. The rough surface was attributed to preferential grain etching confirmed by a polarization curve showing a linear relationship between the EP current and voltage and the absence of the current plateau region. The cathode was modified to make its surface area twice that of cathode-I. The modified cathode (cathode-M) provided a current plateau region in the corresponding I-V curves measured at different cavity temperatures. The onset voltage for the plateau was found to be higher at higher cavity temperatures. Here this study revealed that even with cathode-M, the standard 18 V was low for EP of such large-sized cavities when the cavity temperature was 18 °C. EP performed at a higher voltage of 22–24.5 V with cathode-M yielded a smooth surface with a grain step height of only 0.6 μm. The applied EP conditions also improved removal uniformity along the cavity length. In contrast to the cavity treated with cathode-I, the cavities treated with cathode-M achieved a significantly higher accelerating gradient (Eacc ) in vertical tests conducted in a cryostat at 2 K. The modified EP was found efficient to produce the cavities that achieved Eacc of 22.4 MV/m, required by PIP II project in the baseline RF tests, to qualify for further surface processing used to enhance their quality factors.
bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication, and can enable fine-tuning of cavity temperature treatments.
The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can enable unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics.
Electropolishing (EP) of 1.3 GHz niobium superconducting RF cavities is conducted to achieve a desired smooth and contaminant-free surface that yields good RF performance. Achieving a smooth surface of a large-sized elliptical cavity with the standard EP conditions was found to be challenging. This work aimed to conduct a systematic parametric EP study to understand the effects of various EP parameters on the surface of 650 MHz niobium cavities used in the Proton Improvement Plan-II (PIP-II) linear accelerator. Parameters optimized in this study provided a smooth surface of the cavities. The electropolished cavity showed significantly a higher accelerating gradient meeting baseline requirement and qualified for further surface treatment to improve the cavity quality factor.
Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.
Upcoming projects requiring high-Q 650 MHz medium-to-high-β elliptical cavities drive a need to understand magnetic RF loss mechanisms and mitigations in greater detail. High-temperature annealing and fast-cooldowns have proven effective techniques for promoting magnetic flux expulsion in cavities, however the extent of their effectiveness has been observed to vary between niobium material lot and vendor. We explore the fast-cooldown method, and high-temperature annealing (900C) in 644-650 MHz cavities fabricated from two different niobium vendors: Tokyo-Denkai, and Ningxia. which promote flux-expulsion efficiency. Using EBSD and PPMS methods, we aim to trace cavity flux expulsion efficiency to specific, measurable properties of the bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication, and can enable fine-tuning of cavity temperature treatments.
The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can al-low to achieve unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics. Using Nb SRF cavities, we run a proof of principle search for the dark photon dark matter candidate at fixed frequency demonstrating the deepest sensitivity to wavelike dark mater [1]. The Dark SRF experiment uses two 1.3GHz SRF cavities to conduct a light shining through wall (LSW) experiment to attempt producing and detecting dark photons in the laboratory. The results of this first superconducting LSW search were recently published [2] and we are now working on the second phase of the experiment, which will be run in a dilution refrigerator using 2.6GHz SRF cavities. In addition to the limits we have achieved, we will also present the experiments we are currently developing, such as the heterodyne axion DM search [3, 4], the SERAPH series of experiments, and gravitational waves searches based on SRF cavities as proposed in [5-8].
Two 2.6 GHz SRF cavities are being used for a dark photon search at the vertical test stand (VTS) in FNAL, for the second phase of the Dark SRF experiment. During testing at 2 K the cavities experience frequency detuning caused by microphonics and slow frequency drifts. The experiment requires that the two cavities have the same frequency within the cavity's bandwidth. These two cavities are equipped with frequency tuners consisting of three piezo actuators. The piezo actuators are used for fine-fast frequency tuning. A proportional-integral (PI) loop utilizing the three piezos on the emitter was used to stabilize the cavity frequency and match the receiver cavity frequency. The results from this implementation will be discussed. The integration time was also calculated via simulation.
Upcoming projects requiring high-Q ~650 MHz medium-to-high-! elliptical cavities drive a need to understand magnetic RF loss mechanisms and mitigations in greater detail. We explore the fastcooldown method, and high-temperature annealing (900°C) in 644- 650 MHz SRF cavities fabricated from two different niobium vendors: Tokyo-Denkai (TD), and Ningxia (NX). Using EBSD and PPMS methods, we aim to trace cavity flux expulsion efficiency to specific, measurable properties of the bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication.
Magnetic flux expulsion properties of the superconducting material such as bulk niobium, widely used for the radio-frequency cavity fabrication, substantially affect the performance characteristics of the cavities. The quality factor of the SRF resonators can be significantly compromised due to the presence of the trapped flux vortices causing additional RF energy losses in the material. Large number of experiments have been carried out by different research groups to establish the correlation of the flux trapping in niobium cavities with the presence of impurities in niobium as well as various surface treatment methods. Majority of these experiments utilize commercially available cryogenic fluxgate magnetic sensors to measure the field before and after the niobium transition to the superconducting state to quantify the amount of flux trapped. One disadvantage of the typically used fluxgates is the size of the sensing volume. As an example, the Barting-ton F and G type cryogenic fluxgates have a sensing core length of about 30mm, which is comparable to the curvature radius of the cavity walls and hence the magnetic field lines curvature radius after the expulsion. Thus, the measured field value needs to be corrected to account for the sensor effective averaging over the sensing volume. In case of the sharper geometries, for instance if the flux expulsion to be measured on the edge of the rectangular niobium flat sheet with a thickness of ~5mm, the use of the fluxgate would be impractical.
Radio frequency superconductivity is a cornerstone technology for many future HEP particle accelerators and experiments from colliders to proton drivers for neutrino facilities to searches for dark matter. While the performance of superconducting RF (SRF) cavities has improved significantly over the last decades, and the SRF technology has enabled new applications, the proposed HEP facilities and experiments pose new challenges. To address these challenges, the field continues to generate new ideas and there seems to be a vast room for improvements. In this paper we discuss the key research directions that are aligned with and address the future HEP needs.
Field emission (FE) is one of the main limiting factors of superconducting radio-frequency (SRF) cavities operating in accelerators and it occurs whenever contaminants, like dust, metal flakes or even absorbates, are present on the surface of the cavity high electric field region. Field emission reduces the maximum achievable accelerating field and generates free electrons that may interact with the beam, damage or activate the beamline. One practical method that can be used to mitigate this problem is in-situ plasma cleaning, or plasma processing. The development of a processing that can be applied in-situ is extremely advantageous, since it enables the recovery of the cryomodule performance without the need of disassembling the whole cryomodule, which is an extremely expensive and time-consuming process. On the other hand, plasma processing only requires the cryomodule warm-up to room-temperature and the subsequent processing of the contaminated cavities. The entire process is reasonably quick and involves a limited number of personnel. For these reasons we would like to advocate for continuing to invest in the R\&D of plasma processing to optimize its applicability in cryomodules and for extending the technique to other frequency ranges and cavities geometries.