The development and testing of the Off Specular MicrOstrip Neutron Detector (OSMOND) is described. Based on a microstrip gas chamber the aim of the project was to produce a high counting rate detector capable of replacing the existing rate limited scintillator detectors currently in use on the CRISP reflectometer for off specular reflectometry experiments. The detector system is described together with results of neutron beam tests carried out at the ISIS spallation neutron source.
The development and testing of the FastGas neutron detector is described. Based on a Gas Microstrip Chamber the aim of the project was to produce a high counting rate detector capable of replacing the existing 3He tubes for specular reflectometry, currently in use on the ISIS reflectometer instruments. The detector system is described together with results of neutron beam tests carried out at the ISIS spallation neutron source.
The development and testing of the HOTWAXS position-sensitive X-ray detector for Synchrotron Radiation Sources is described. Funded from a facility development grant, the aim of the project was to produce a high counting rate, parallax-free photon counting detector to be used in the combined studies of X-ray absorption fine structure and X-ray diffraction (XAFS/XRD), and also in the technique of small angle and wide angle X-ray scattering (SAXS/WAXS). The detector system is described together with results of experiments carried out at the Daresbury Laboratory Synchrotron Radiation Source.
The development and testing of a two-dimensional (2-D) prototype detector based on a microstrip gas chamber (MSGC) is reported using a gas mixture of 2.5 bar /sup 3/He and 2.5 bar CF/sub 4/. The second coordinate is obtained by utilising a plane of wires as pick up electrodes. The detector is operated with the wire plane at such a potential so as not to induce any gain around the wires. This means that the high tolerances normally associated with wire planes in multi wire proportional counters are not mandatory. The detector comprises of 48 individually instrumented channels in both X (MSGC strips) and Y (orthogonal wire plane). A specially designed encoding module has been constructed which feeds digital addresses for each event to the ISIS Data Acquisition Electronics (DAE) system. An intrinsic detector resolution of /spl sim/1 mm full-width at half-maximum has been measured for both dimensions (in experimental exposures on the ROTAX beamline at ISIS) which is degraded slightly by the digital resolution for the overall system. This readout method is shown to be very tolerant of a poor signal to noise ratio in the readout channels (unlike traditional analogue wire chamber readout systems) and permits the operation of the MSGC at low avalanche gains (/spl sim/10) which helps to maximize the rate and lifetime performance of the detector as well as permitting data capture rates in the megahertz range. The event timing resolution is comfortably submicrosecond and is, therefore, suitable for applications on spallation neutron sources.
The development and testing of a 2-D prototype detector based on a gas microstrip detector (GMSD) is reported using a gas mixture of 2.5 bar /sup 3/He and 2.5 bar CF/sub 4/. The second coordinate is obtained by utilising a plane of wires as pick up electrodes. The detector is operated with the wire plane at such a potential so as not to induce any gain around the wires. This means that the high tolerances normally associated with wire planes in multi wire proportional counters are not mandatory. The detector comprises of 48 individually instrumented channels in both X (GMSD strips) and Y (transverse wire plane). A specially designed encoding module has been constructed which feeds digital addresses for each event to the ISIS data taking electronics system (DAE). An intrinsic detector resolution of /spl sim/1 mm FWHM has been measured for both dimensions (in experimental exposures on the ROTAX beamline at ISIS) which is degraded slightly by the digital resolution for the overall system. This readout method is shown to be very tolerant of a poor signal to noise ratio in the readout channels (unlike traditional analogue wire chamber readout systems) and permits the operation of the GMSD at low avalanche gains (/spl sim/10) which helps to maximise the rate and lifetime performance of the detector as well as permitting data capture rates in the MHz range. The event timing resolution is comfortably sub microsecond and is therefore suitable for applications on spallation neutron sources.
The development and testing of a soft X-ray gas pixel detector, which uses connector pins for the anodes is reported. Based on a commercial 100 pin connector block, a prototype detector of aperture 25.4mm x 25.4mm can be economically fabricated. The individual pin anodes all show the expected characteristics of small gas detectors capable of counting rates reaching I MHz per pin. A 2-dimensional resistive divide readout system has been developed to permit the imaging properties of the detector to be explored in advance of true pixel readout electronics. (C) 2002 Elsevier Science B.V. All rights reserved.
The development and testing of a neutron gas pixel detector intended for application in neutron diffraction studies is reported. Using standard electrical connector pins as point anodes, the detector is based on a commercial 100 pin connector block. A prototype detector of aperture 25.4 mm x 25.4 mm has been fabricated, giving a pixel size of 2.54mm which matches well to the spatial resolution typically required in a neutron diffractometer. A 2-Dimensional resistive divide readout system has been adapted to permit the imaging properties of the detector to be explored ill advance of true pixel readout electronics. The timing properties of the device match well to the requirements of the ISIS-pulsed neutron source. (C) 2002 Elsevier Science B.V. All rights reserved.