Background and purpose: MRI-guided radiotherapy (MRIgRT) offers multiple potential advantages over CT-guidance. This study examines the potential clinical benefits of MRIgRT for men with localised prostate cancer, in the setting of moderately hypofractionated radiotherapy. We evaluate two-year toxicity outcomes, early biochemical response and patient-reported outcomes (PRO), using data obtained from a multicentre international registry study, for the first group of patients with prostate cancer who underwent treatment on a 1.5 T MR-Linac. Materials and methods: Patients who were enrolled within the MOMENTUM study and received radical treatment with 60 Gy in 20 fractions were identified. PSA levels and CTCAE version 5.0 toxicity data were measured at follow-up visits. Those patients who consented to PRO data collection also completed EQ-5D-5L, EORTC QLQ-C30 and EORTC QLQ-PR25 questionnaires. Results: Between November 2018 and June 2022, 146 patients who had MRIgRT for localised prostate cancer on the 1.5 T MR-Linac were eligible for this study. Grade 2 and worse gastro-intestinal (GI) toxicity was reported in 3 % of patients at three months whilst grade 2 and worse genitourinary (GU) toxicity was 7 % at three months. There was a significant decrease in the median PSA at 12 months. The results from both the EQ-5D-5L data and EORTC global health status scale indicate a decline in the quality of life (QoL) during the first six months. The mean change in score for the EORTC scale showed a decrease of 11.4 points, which is considered clinically important. QoL improved back to baseline by 24 months. Worsening of hormonal symptoms in the first six months was reported with a return to baseline by 24 months and sexual activity in all men worsened in the first three months and returned to baseline at 12 months. Conclusion: This study establishes the feasibility of online-MRIgRT for localised prostate on a 1.5 T MR-Linac with low rates of toxicity, similar to that published in the literature. However, the clinical benefits of MRIgRT over conventional radiotherapy in the setting of moderate hypofractionation is not evident. Further research will focus on the delivery of ultrahypofractionated regimens, where the potential advantages of MRIgRT for prostate cancer may become more discernible.
Background and purpose: Treatment planning for MR-guided stereotactic body radiotherapy (SBRT) for pancreatic tumors can be challenging, leading to a wide variation of protocols and practices. This study aimed to harmonize treatment planning by developing a consensus planning protocol for MR-guided pancreas SBRT on a 1.5 T MRLinac. Materials and methods: A consortium was founded of thirteen centers that treat pancreatic tumors on a 1.5 T MRLinac. A phased planning exercise was conducted in which centers iteratively created treatment plans for two cases of pancreatic cancer. Each phase was followed by a meeting where the instructions for the next phase were determined. After three phases, a consensus protocol was reached. Results: In the benchmarking phase (phase I), substantial variation between the SBRT protocols became apparent (for example, the gross tumor volume (GTV) D99% ranged between 36.8 - 53.7 Gy for case 1, 22.6 - 35.5 Gy for case 2). The next phase involved planning according to the same basic dosimetric objectives, constraints, and planning margins (phase II), which led to a large degree of harmonization (GTV D99% range: 47.9-53.6 Gy for case 1, 33.9-36.6 Gy for case 2). In phase III, the final consensus protocol was formulated in a treatment planning system template and again used for treatment planning. This not only resulted in further dosimetric harmonization (GTV D99% range: 48.2-50.9 Gy for case 1, 33.5-36.0 Gy for case 2) but also in less variation of estimated treatment delivery times. Conclusion: A global consensus protocol has been developed for treatment planning for MR-guided pancreatic SBRT on a 1.5 T MR-Linac. Aside from harmonizing the large variation in the current clinical practice, this
HERMES is a phase II trial of MRI-guided daily-adaptive radiotherapy (MRIgART) randomising men with localised prostate cancer to either 2-fractions of SBRT with a boost to the tumour or 5-fraction SBRT. In the context of this highly innovative regime the dose delivered must be carefully considered. The first ten patients recruited to HERMES were analysed in order to establish the dose received by the targets and organs at risk (OARS) in the context of intrafraction motion. A regression analysis was performed to measure how the volume of air within the rectum might further impact rectal dose secondary to the electron return effect (ERE). One hundred percent of CTV target objectives were achieved on the MRI taken prior to beam-on-time. The post-delivery MRI showed that high-dose CTV coverage was achieved in 90% of sub-fractions (each fraction is delivered in two sub-fractions) in the 2-fraction cohort and in 88% of fractions the 5-fraction cohort. Rectal D1 cm3 was the most exceeded constraint; three patients exceeded the D1 cm3 < 20.8 Gy in the 2-fraction cohort and one patient exceeded the D1 cm3 < 36 Gy in the 5-fraction cohort. The volume of rectal gas within 1 cm of the prostate was directly proportional to the increase in rectal D1 cm3, with a strong (R = 0.69) and very strong (R = 0.90) correlation in the 2-fraction and 5-fraction cohort respectively. Dose delivery specified in HERMES is feasible, although for some patients delivered doses to both target and OARs may vary from those planned.
The implementation of MRI-guided online adaptive radiotherapy has enabled extension of therapeutic radiographers' roles to include contouring. An offline interobserver variability study compared five radiographers' and five clinicians' contours on 10 MRIs acquired on a MR-Linac from 10 patients. All contours were compared to a "gold standard" created from an average of clinicians' contours. The median (range) DSC of radiographers' and clinicians' contours compared to the "gold standard" was 0.91 (0.86-0.96), and 0.93 (0.88-0.97) respectively illustrating non-inferiority of the radiographers' contours to the clinicians. There was no significant difference in HD, MDA or volume size between the groups.
Background and Purpose: The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers' roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. Materials and Methods: 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. Results: Comparison of the radiographers' and clinicians' contours resulted in a median (range) DSC of 0.92 (0.86 - 0.99), median (range) MDA of 0.98 mm (0.2-1.7) and median (range) HD of 6.3 mm (2.5- 11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians' offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88-1.0), median (range) MDA was 0.8 mm (0.04-1.18) and HD was 5.15 mm (2.09-8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians' offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. Conclusion: Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training. (c) 2022 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 180 (2023) 1-10 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Hybrid systems that combine Magnetic Resonance Imaging (MRI) and linear accelerators are available clinically to guide and adapt radiotherapy. Vendor-approved MRI sequences are provided, however alternative sequences may offer advantages. The aim of this study was to develop a systematic approach for non-vendor sequence evaluation, to determine safety, accuracy and overall clinical application of two potential sequences for bladder cancer MRI guided radiotherapy. Non-vendor sequences underwent and passed clinical image qualitative review, phantom quality assurance, and radiotherapy planning assessments. Volunteer workflow tests showed the potential for one sequence to reduce workflow time by 27% compared to the standard vendor sequence.
PURPOSE:Ultrahypofractionated radiation therapy (UHRT) is an effective treatment for localized prostate cancer with an acceptable toxicity profile; boosting the visible intraprostatic tumor has been shown to improve biochemical disease-free survival with no significant effect on genitourinary (GU) and gastrointestinal (GI) toxicity. METHODS AND MATERIALS:HERMES is a single-center noncomparative randomized phase 2 trial in men with intermediate or lower high risk prostate cancer. Patients were allocated (1:1) to 36.25 Gy in 5 fractions over 2 weeks or 24 Gy in 2 fractions over 8 days with an integrated boost to the magnetic resonance imaging (MRI) visible tumor of 27 Gy in 2 fractions. A minimization algorithm with a random element with risk group as a balancing factor was used for participant randomization. Treatment was delivered on the Unity MR-Linac (Elekta AB) with daily online adaption. The primary endpoint was acute GU Common Terminology Criteria for Adverse Events version 5.0 toxicity with the aim of excluding a doubling of the rate of acute grade 2+ GU toxicity seen in PACE. Analysis was by treatment received and included all participants who received at least 1 fraction of study treatment. This interim analysis was prespecified (stage 1 of a 2-stage Simon design) for when 10 participants in each treatment group had completed the acute toxicity monitoring period (12 weeks after radiation therapy). RESULTS:Acute grade 2 GU toxicity was reported in 1 (10%) patient in the 5-fraction group and 2 (20%) patients in the 2-fraction group. No grade 3+ GU toxicities were reported. CONCLUSIONS:At this interim analysis, the rate of GU toxicity in the 2-fraction and 5-fraction treatment groups was found to be below the prespecified threshold (5/10 grade 2+) and continuation of the study to complete recruitment of 23 participants per group was recommended.
Accelerated coronary artery disease seen following radiation exposure is termed 'radiation-induced coronary artery disease' (RICAD) and results from both the direct and indirect effects of radiation exposure. Long-term data are available from survivors of nuclear explosions and accidents, nuclear workers as well as from radiotherapy patients. The last group is, by far, the biggest cause of RICAD presentation.The incidence of RICAD continues to increase as cancer survival rates improve and it is now the second most common cause of morbidity and mortality in patients treated with radiotherapy for breast cancer, Hodgkin's lymphoma and other mediastinal malignancies. RICAD will frequently present atypically or even asymptomatically with a latency period of at least 10 years after radiotherapy treatment. An awareness of RICAD, as a long-term complication of radiotherapy, is therefore essential for the cardiologist, oncologist and general medical physician alike.Prior cardiac risk factors, a higher radiation dose and a younger age at exposure seem to increase a patient's risk ratio of developing RICAD. Significant radiation exposure, therefore, requires a low threshold for screening for early diagnosis and timely intervention.
IntroductionThe Elekta Unity MR-Linac (MRL) has enabled adaptive radiotherapy (ART) for patients with head and neck cancers (HNC). Adapt-To-Shape-Lite (ATS-Lite) is a novel Adapt-to-Shape strategy that provides ART without requiring daily clinician presence to perform online target and organ at risk (OAR) delineation. In this study we compared the performance of our clinically-delivered ATS-Lite strategy against three Adapt-To-Position (ATP) variants: Adapt Segments (ATP-AS), Optimise Weights (ATP-OW), and Optimise Shapes (ATP-OS).MethodsTwo patients with HNC received radical-dose radiotherapy on the MRL. For each fraction, an ATS-Lite plan was generated online and delivered and additional plans were generated offline for each ATP variant. To assess the clinical acceptability of a plan for every fraction, twenty clinical goals for targets and OARs were assessed for all four plans.Results53 fractions were analysed. ATS-Lite passed 99.9% of mandatory dose constraints. ATP-AS and ATP-OW each failed 7.6% of mandatory dose constraints. The Planning Target Volumes for 54 Gy (D95% and D98%) were the most frequently failing dose constraint targets for ATP. ATS-Lite median fraction times for Patient 1 and 2 were 40 mins 9 s (range 28 mins 16 s – 47 mins 20 s) and 32 mins 14 s (range 25 mins 33 s – 44 mins 27 s), respectively.ConclusionsOur early data show that the novel ATS-Lite strategy produced plans that fulfilled 99.9% of clinical dose constraints in a time frame that is tolerable for patients and comparable to ATP workflows. Therefore, ATS-Lite, which bridges the gap between ATP and full ATS, will be further utilised and developed within our institute and it is a workflow that should be considered for treating patients with HNC on the MRL.
Background:The prostate demonstrates inter- and intra- fractional changes and thus adaptive radiotherapy would be required to ensure optimal coverage. Daily adaptive radiotherapy for MRI-guided radiotherapy can be both time and resource intensive when structure delineation is completed manually. Contours can be auto-generated on the MR-Linac via a deformable image registration (DIR) based mapping process from the reference image. This study evaluates the performance of automatically generated target structure contours against manually delineated contours by radiation oncologists for prostate radiotherapy on the Elekta Unity MR-Linac. Methods:Plans were generated from prostate contours propagated by DIR and rigid image registration (RIR) for forty fractions from ten patients. A two-dose level SIB (simultaneous integrated boost) IMRT plan is used to treat localised prostate cancer; 6000 cGy to the prostate and 4860 cGy to the seminal vesicles. The dose coverage of the PTV 6000 and PTV 4860 created from the manually drawn target structures was evaluated with each plan. If the dose objectives were met, the plan was considered successful in covering the gold standard (clinician-delineated) volume. Results:The mandatory PTV 6000 dose objective (D98% > 5580 cGy) was met in 81 % of DIR plans and 45 % of RIR plans. The SV were mapped by DIR only and for all the plans, the PTV 4860 dose objective met the optimal target (D98% > 4617 cGy). The plans created by RIR led to under-coverage of the clinician-delineated prostate, predominantly at the apex or the bladder-prostate interface. Conclusion:Plans created from DIR propagation of prostate contours outperform those created from RIR propagation. In approximately 1 in 5 DIR plans, dosimetric coverage of the gold standard PTV was not clinically acceptable. Thus, at our institution, we use a combination of DIR propagation of contours alongside manual editing of contours where deemed necessary for online treatments.
The drive towards hypofractionated prostate radiotherapy is motivated by a low alpha/beta ratio for prostate cancer (1 to 3 Gy) compared to surrounding organs at risk, implying an improved therapeutic ratio with increasing dose per fraction. Early evidence from studies of ultrahypofractionated (UHF) prostate HDR brachytherapy has shown good tolerability in terms of normal tissue toxicities and clinical outcomes similar to conventional fractionation schedules.MR-guided stereotactic body radiotherapy (SBRT) with online plan adaptation and real-time tumour imaging may enable UHF doses to be delivered to the prostate safely, without the invasiveness of brachytherapy. The feasibility of UHF prostate treatment planning for the Unity MR-Linac (MRL, Elekta AB, Stockholm) was investigated for target prescriptions and planning constraints derived from the HDR brachytherapy and SBRT literature.Monaco 5.40 (Elekta) was used to generate MRL step-and-shoot IMRT plans for three dose fractionation protocols (5, 2 and 1 fractions), for ten randomly selected previously treated prostate cancer patients. Of the ten plans per UHF scheme, all clinical goals were met in all cases for 5 fractions, and in six cases for both 2 and 1 fraction schemes. PTV D95% was compromised by up to 6.4% and 3.9% of the associated target dose for 2 and 1 fraction plans respectively. There were two cases of PTV D95% compromise greater than a 5% dose decrease for the 2 fraction plans. The study suggests feasibility of the UHF treatment planning approaches if combined with real-time motion mitigation strategies.
242 Background: The Unity MR-Linac combines a 7-MV Linac with 1.5T magnetic resonance (MR) imaging capability and it enables adaptive radiotherapy, whereby the target and organs at risk are recontoured and a plan is optimised daily. During treatment a session MR image is taken first, on which the target and organs-at-risk are contoured, and a plan created. A verification image is taken prior to dose delivery to identify intra-fractional changes. If present, the daily treatment plan is shifted to reflect the anatomy. A post-treatment image is acquired at the end of treatment. This study evaluates the dosimetric changes to the rectum caused by intra-fractional changes during treatment delivery for prostate stereotactic body radiotherapy (SBRT) calculated on the verification and post-treatment images. Methods: The first five patients treated on the MR-Linac with 5-fraction SBRT to the prostate are included in this study. For each patient, the rectum was contoured on the verification and post-treatment MR images for each of the five fractions. The dose delivered to the rectum with the original treatment plan was then calculated on each image and the V36Gy rectal dose constraint was noted. Results: Out of the 25 fractions, a post treatment image was not performed in one fraction; 24 fractions were therefore analysed in total. The rectal V36Gy dose constraint exceeded the mandatory target of 2cc on 50% of the verification images and 46% of the post-treatment images. In 6 fractions the rectal V36Gy was greater than 2cc on both the verification and post-treatment images suggesting this rectal constraint was exceeded throughout treatment. In 17% of patients, the volume of rectum receiving 36Gy increased at each timepoint an image was taken during the treatment workflow. Conclusions: The rectal V36Gy dose constraint is susceptible to minor changes in rectal filling, which may often lead to higher than the accepted dose constraint. Thus, a single planning CT scan is unlikely to be representative of dose delivered. Adaptive radiotherapy can reduce this uncertainty somewhat, but intra-fraction dose re-optimisation would be required to ensure the rectal V36Gy remains acceptable at all times.
IntroductionMR-guided adapted radiotherapy (MRgART) using a high field MR-linac has recently become available. We report the estimated delivered fractional dose of the first five prostate cancer patients treated at our centre using MRgART and compare this to C-Arm linac daily Image Guided Radiotherapy (IGRT).MethodsPatients were treated using adapted treatment plans shaped to their daily anatomy. The treatments were recalculated on an MR image acquired immediately prior to treatment delivery in order to estimate the delivered fractional dose. C-arm linac non-adapted VMAT treatment plans were recalculated on the same MR images to estimate the fractional dose that would have been delivered using conventional radiotherapy techniques using a daily IGRT protocol.Results95% and 93% of mandatory target coverage objectives and organ at risk dose constraints were achieved by MRgART and C-arm linac delivered dose estimates, respectively. Both delivery techniques were estimated to have achieved 98% of mandatory Organ At Risk (OAR) dose constraints whereas for the target clinical goals, 86% and 80% were achieved by MRgART and C-arm linac delivered dose estimates.ConclusionsProstate MRgART can be delivered using the a high field MR-linac. Radiotherapy performed on a C-arm linac offers a good solution for prostate cancer patients who present with favourable anatomy at the time of reference imaging and demonstrate stable anatomy throughout the course of their treatment. For patients with critical OARs abutting target volumes on their reference image we have demonstrated the potential for a target dose coverage improvement for MRgART compared to C-arm linac treatment.
Background A manned mission to Mars has been contemplated by the world's largest space agencies for a number of years. The duration of the trip would necessitate a much longer exposure to deep space radiation than any human has ever been exposed to in the past. Concern regarding cancer risk has thus far stalled the progress of deep space exploration; however, the effect of space radiation on the cardiovascular system is significantly less well understood. Discussion Damage by radiation in space is mediated by a number of sources, including X-rays, protons and heavier charged atomic nuclei (HZE ions, the high-energy component of galactic cosmic rays). Previously, only lunar mission astronauts have been exposed to significant deep space radiation, with all other missions being low earth orbits only. The effect of this radiation on the human body has been inconclusively studied, and the long-term damage caused to the vascular endothelium by this radiation due to the effect of high-energy particles is not well known. Conclusion Current radiation shielding technology, which would be viable for use in spacecraft, would not eliminate radiation risk. Similar to how a variety of shielding techniques are used every day by radiographers, again without full risk elimination, we need to explore and better understand the effect of deep space radiation in order to ensure the safety of those on future space missions.