BACKGROUND:Prostate cancer (PCa) models in mice and rats are limited by their size and lack of a clearly delineated or easily accessible prostate gland. The canine PCa model is currently the only large animal model which can be used to test new preclinical interventions but is costly and availability is sparse. As an alternative, we developed an orthotopic human prostate tumor model in an immunosuppressed New Zealand White rabbit. Rabbits are phylogenetically closer to humans, their prostate gland is anatomically similar, and its size allows for clinically-relevant testing of interventions. METHODS:Rabbits were immunosuppressed via injection of cyclosporine. Human PC3pipGFP PCa cells were injected into the prostate via either (a) laparotomy or (b) transabdominal ultrasound (US) guided injection. Tumor growth was monitored using US and magnetic resonance imaging (MRI). Contrast-enhanced ultrasound (CEUS) imaging using nanobubbles and Lumason microbubbles was also performed to examine imaging features and determine the optimal contrast dose required for enhanced visualization of the tumor. Ex vivo fluorescence imaging, histopathology, and immunohistochemistry analyses of the collected tissues were performed to validate tumor morphology and prostate-specific membrane antigen (PSMA) expression. RESULTS:Immunosuppression and tumor growth were, in general, well-tolerated by the rabbits. Fourteen out of 20 rabbits, with an average age of 8 months, successfully grew detectable tumors from Day 14 onwards after cell injection. The tumor growth rate was 39 ± 25 mm2 per week. CEUS and MRI of tumors appear hypoechoic and T2 hypointense, respectively, relative to normal prostate tissue. Minimally invasive US-guided tumor cell injection proved to be a better method compared to laparotomy due to the shorter recovery time required for the rabbits following injection. Among the rabbits that grew tumors, seven had tumors both inside and outside the prostate, three had tumors only inside the prostate, and four had tumors exclusively outside of the prostate. All tumors expressed the PSMA receptor. CONCLUSIONS:We have established, for the first time, an orthotopic PCa rabbit model via percutaneous US-guided tumor cell inoculation. This animal model is an attractive, clinically relevant intermediate step to assess preclinical diagnostic and therapeutic compounds.
Significance: An effective contrast agent for concurrent multimodal photoacoustic (PA) and ultrasound (US) imaging must have both high optical absorption and high echogenicity. Integrating a highly absorbing dye into the lipid shell of gas core nanobubbles (NBs) adds PA contrast to existing US contrast agents but may impact agent ultrasonic response. Aim: We report on the development and ultrasonic characterization of lipid-shell stabilized C3F8 NBs with integrated Sudan Black (SB) B dye in the shell as dual-modal PA-US contrast agents. Approach: Perfluoropropane NBs stabilized with a lipid shell including increasing concentrations of SB B dye were formulated by amalgamation (SBNBs). Physical properties of SBNBs were characterized using resonant mass measurement, transmission electron microscopy and pendant drop tensiometry. Concentrated bubble solutions were imaged for 8 min to assess signal decay. Diluted bubble solutions were stimulated by a focused transducer to determine the response of individual NBs to long cycle (30 cycle) US. For assessment of simultaneous multimodal contrast, bulk populations of SBNBs were imaged using a PA and US imaging platform. Results: We produced high agent yield (similar to 10(11)) with a mean diameter of similar to 200 to 300 nm depending on SB loading. A 40% decrease in bubble yield was measured for solutions with 0.3 and 0.4 mg/ml SB. The addition of SB to the shell did not substantially affect NB size despite an increase in surface tension by up to 8 mN/m. The bubble decay rate increased after prolonged exposure (8 min) by dyed bubbles in comparison to their undyed counterparts (2.5-fold). SB in bubble shells increased gas exchange across the shell for long cycle US. PA imaging of these agents showed an increase in power (up to 10 dB) with increasing dye. Conclusions: We added PA contrast function to NBs. The addition of SB increased gas exchange across the NB shell. This has important implications in their use as multimodal agents. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License.
Electrochemical nanolithography using grafted polymer brushes with terthiophene (3T) pendent was investigated. The film was fabricated by surface electropolymerization of a reversible addition−fragmentation chain-transfer agent macroinitiator containing a 3T pendant molecule and the subsequent polymer brush growth from a 3T functionalized methacrylate monomer (3T-Methacrylate). Electrochemical nanolithography and patterning were done using conducting atomic force microscopy (C-AFM) enabling precise nanopattern fabrication. In contrast to direct nanowriting, dip pen nanolithography, and nanolithographic additive manufacturing, the electrochemical nanolithography can be readily facilitated by applying a bias voltage between a conductive AFM tip and the grafted polymer brush film at ambient conditions and without ink transfer. The height and electrical resistance of the nanopatterns were dependent on the writing parameters (i.e. applied bias voltage and scan rate).
Nanotechnology currently enables the fabrication of uniform solid nanoparticles and liquid nano-emulsions, but not uniform gaseous nanobubbles (NBs). In this article, for the first time, a method based on microfluidics that directly produces monodisperse NBs is reported. Specifically, a two-component gas mixture of water-soluble nitrogen and water-insoluble octafluoropropane as the gas phase are used in a microfluidic bubble generator. First, monodisperse microbubbles (MBs) with a classical microfluidic flow-focusing junction is generated, then the MBs shrink down to ≈100 nm diameter, due to the dissolution of the water-soluble components in the gas mixture. The degree of shrinkage is controlled by tuning the ratio of water-soluble to water-insoluble gas components. This technique maintains the monodispersity of the NBs, and enables precise control of the final NB size. It is found that the monodisperse NBs show better homogeneity than polydisperse NBs in in vitro ultrasound imaging experiments. Proof-of-concept in vivo kidney imaging is performed in live mice, demonstrating enhanced contrast using the monodisperse NBs. The NB monodispersity and imaging results make microfluidically generated NBs promising candidates as ultrasound contrast and molecular imaging agents.
Ultrasound imaging is routinely used to guide prostate biopsies, yet delineation of tumors within the prostate gland is extremely challenging, even with microbubble (MB) contrast. A more effective ultrasound protocol is needed that can effectively localize malignancies for targeted biopsy or aid in patient selection and treatment planning for organ-sparing focal therapy. This study focused on evaluating the application of a novel nanobubble ultrasound contrast agent targeted to the prostate specific membrane antigen (PSMA-targeted NBs) in ultrasound imaging of prostate cancer (PCa) in vivo using a clinically relevant orthotopic tumor model in nude mice. Our results demonstrated that PSMA-targeted NBs had increased extravasation and retention in PSMA-expressing orthotopic mouse tumors. These processes are reflected in significantly different time intensity curve (TIC) and several kinetic parameters for targeted versus non-targeted NBs or LUMASON MBs. These, may in turn, lead to improved image-based detection and diagnosis of PCa in the future.
Proper material selection has been one of the most important aspects in the design of chemical process equipment. In particular, the oil and gas industry has transitioned from using metals to non-metals (e.g. advanced and high performance polymeric materials) in most of their structural components, coatings, equipment parts, and the like. It is therefore imperative to understand the advantages and limitations of these polymer materials before they can be effectively used for a specific application. This review article aims to provide an overview of the properties, applications, and durability against reactivity and degradation of high performance polymers commonly used in the oil and gas industry. These include polysulfone, polyetherimide, polyphenylene sulfide, polyetheretherketone, fluoropolymers, and other high performance thermosets, elastomers, and polymer nanocomposites. This article also covers the current research efforts in improving the properties of high performance polymers and expanding their applications (including 3D printing or additive manufacturing) in the oil and gas industry.
Understanding the pressure dependence of the nonlinear behavior of ultrasonically excited phospholipid-stabilized nanobubbles (NBs) is important for optimizing ultrasound exposure parameters for implementations of contrast enhanced ultrasound, critical to molecular imaging. The viscoelastic properties of the shell can be controlled by the introduction of membrane additives, such as propylene glycol as a membrane softener or glycerol as a membrane stiffener. We report on the production of high-yield NBs with narrow dispersity and different shell properties. Through precise control over size and shell structure, we show how these shell components interact with the phospholipid membrane, change their structure, affect their viscoelastic properties, and consequently change their acoustic response. A two-photon microscopy technique through a polarity-sensitive fluorescent dye, C-laurdan, was utilized to gain insights on the effect of membrane additives to the membrane structure. We report how the shell stiffness of NBs affects the pressure threshold (P-t) for the sudden amplification in the scattered acoustic signal from NBs. For narrow size NBs with 200 nm mean size, we find P-t to be between 123 and 245 kPa for the NBs with the most flexible membrane as assessed using C-Laurdan, 465-588 kPa for the NBs with intermediate stiffness, and 588-710 kPa for the NBs with stiff membranes. Numerical simulations of the NB dynamics are in good agreement with the experimental observations, confirming the dependence of acoustic response to shell properties, thereby substantiating further the development in engineering the shell of ultrasound contrast agents. The viscoelastic-dependent threshold behavior can be utilized for significantly and selectively enhancing the diagnostic and therapeutic ultrasound applications of potent narrow size NBs.
Microbubbles (MBs) stabilized by particle surfactants (i.e., Pickering bubbles) have better thermodynamic stability compared to MBs stabilized by small molecules as a result of steric hindrance against coalescence, higher diffusion resistance, and higher particle desorption energy. In addition, the use of particles to stabilize MBs that are typically used as an ultrasound (US) contrast agent can also introduce photoacoustic (PA) properties, thus enabling a highly effective dual-modality US and PA contrast agent. Here, we report the use of partially reduced and functionalized graphene oxide as the sole surfactant to stabilize perfluorocarbon gas bubbles in the preparation of a dual-modality US and PA agent, with high contrast in both imaging modes and without the need for small-molecule or polymer additives. This approach offers an increase in loading of the PA agent without destabilization and increased thickness of the MB shell compared to traditional systems, in which the focus is on adding a PA agent to existing MB formulations.
Drug delivery to solid tumors using echogenic nanobubbles (NBs) and ultrasound (US) has recently gained significant interest. The approach combines attributes of nanomedicine and the enhanced permeation and retention (EPR) effect with the documented benefits of ultrasound to improve tumor drug distribution and treatment outcomes. However, optimized drug loading strategies, the drug-carrying capacity of NBs and their drug delivery efficiency have not been explored in depth and remain unclear. Here, we report for the first time on the development of a novel deprotonated hydrophobic doxorubicin-loaded C3F8 nanobubble (hDox-NB) for more effective US-mediated drug delivery. In this study, the size distribution and yield of hDox-NBs were measured via resonant mass measurement, while their drug-loading capacity was determined using a centrifugal filter technique. In vitro acoustic properties including contrast-imaging enhancement, initial echogenic signal, and decay were assessed and compared to doxorubicin hydrochloride loaded-NBs (Dox.HCl-NBs). In addition, in vitro therapeutic efficacy of hDox-NBs was evaluated by cytotoxicity assay in human ovarian cancer cells (OVCAR-3). The results showed that the hDox-NBs were small (300.7 ± 4.6 nm), and the drug loading content was significantly enhanced (2 fold higher) compared to Dox.HCl-NBs. Unexpectedly, the in vitro acoustic performance was also improved by inclusion of hDox into NBs. hDox-NB showed higher initial US signal and a reduced signal decay rate compared to Dox.HCl-NBs. Furthermore, hDox-NBs combined with higher intensity US exhibited an excellent therapeutic efficacy in human ovarian cancer cells as shown in a reduction in cell viability. These results suggest that hDox-NBs could be considered as a promising theranostic agent to achieve a more effective noninvasive US-mediated drug delivery for cancer treatment.
Polymer modification has been attracting the attention of the scientific community due to its process of combining attractive properties of different materials and fusing it into a hybrid high performance material. These properties depend on the type of environment and its application. Due to the harsh conditions imposed by geothermal fluids to ordinary materials of construction, high performance materials are desired to lessen the frequency or even eliminate maintenance cleaning of surface components and to prolong the service life of pipelines and other surface equipment that are critically affected by erosion-corrosion phenomenon. To further enhance the mechanical properties of a high performance polymer material, nanofillers are usually incorporated in the polymer matrix to make up a nanocomposite. In this study, a nanocomposite (PCN-R-oMMT) made of toughened polymer and organically modified montmorillonite was synthesized to be used as a coating. The enhancement of the mechanical properties of the polymer by addition of oMMT by its intercalation/exfoliation into the polymer matrix was determined using X-Ray Diffraction (XRD), thermogravimetric tests (TGA & DSC), hardness test, and adhesion test. To determine the viability of the synthesized coating in corrosive environment, it was applied to a carbon steel coupon and immersed in simulated acidic geothermal brine. Electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization scans (PPS) were conducted to assess the protection efficiency of the coating. The stability and the protection efficiency of the PCN-R-oMMT were also evaluated under high temperature and high pressure conditions.
The amount of gas in ultrasound contrast agents is related to their acoustic activity. Because of this relationship, gas volume has been used as a key variable in normalizing the in vitro and in vivo acoustic behavior of lipid shell-stabilized bubbles with different sizes and shell components. Despite its importance, bubble gas volume has typically only been theoretically calculated based on bubble size and concentration that is typically measured using the Coulter counter for microbubbles and nanoparticle tracking analysis (NTA) for nanoscale bubbles. However, while these methods have been validated for the analysis of liquid or solid particles, their application in bubble analysis has not been rigorously studied. We have previously shown that resonant mass measurement (RMM) may be a better-suited technique for sub-micron bubble analysis, as it can measure both buoyant and non-buoyant particle size and concentration. Here, we provide validation of RMM bubble analysis by using headspace gas chromatography/mass spectrometry (GC/MS) to experimentally measure the gas volume of the bubble samples. This measurement was then used as ground truth to test the accuracy of theoretical gas volume predictions based on RMM, NTA (for nanobubbles), and Coulter counter (for microbubbles) measurements. The results show that the headspace GC/MS gas volume measurements agreed well with the theoretical predictions for the RMM of nanobubbles but not NTA. For nanobubbles , the theoretical gas volume using RMM was 10% lower than the experimental GC/MS measurements; meanwhile, using NTA resulted in an 82% lower predicted gas volume. For microbubbles, the experimental gas volume from the GC/MS measurements was 27% lower compared to RMM and 72% less compared to the Coulter counter results. This study demonstrates that the gas volume of nanobubbles and microbubbles can be reliably measured using headspace GC/MS to validate bubble size measurement techniques. We also conclude that the accuracy of theoretical predictions is highly dependent on proper size and concentration measurements.
Contrast-enhanced ultrasound with microbubbles has shown promise in detection of prostate cancer (PCa), but sensitivity and specificity of detection remain challenging. Targeted nanoscale contrast agents with improved capability to accumulate in tumors may result in prolonged signal enhancement and improved detection of PCa with ultrasound. Here we report on a new nanobubble contrast agent that specifically targets prostate specific membrane antigen (PSMA) overexpressed in most prostate tumors. The PSMA-targeted bubbles (PSMA-NB) were utilized to simultaneously image dual flank PCa tumors (PSMA-positive PC3pip and PSMA-negative PC3flu) to examine whether the biomarker can be successfully detected and imaged using this probe in a mouse model. Results demonstrate that active targeting of NBs to PSMA rapidly and selectively enhances tumor accumulation and is critical for tumor retention of the contrast agent. Importantly, these processes could be visualized and quantified, in real time, with standard clinical ultrasound. Such demonstration of the immense yet underutilized potential of ultrasound in the area of molecular imaging can open the door to future opportunities for improving sensitivity and specificity of cancer detection using parametric NB-enhanced ultrasound imaging.
Understanding the pressure dependence of the nonlinear behavior of ultrasonically excited phospholipid (PL)-stabilized NBs is important for optimizing US exposure parameters for implementations of contrast enhanced ultrasound, critical to molecular imaging. The viscoelastic properties of the shell can be controlled by introduction of membrane additives, such as propylene glycol as a membrane softener or glycerol as a membrane stiffener. We report for the first time, the production of high yield NBs with narrow dispersity and different shell properties. Through precise control over size and shell structure, we show how these shell components interact with the phospholipid membrane, change its structure, affect their viscoelastic properties, and consequently change their acoustic response. A two-photon microscopy technique through a polarity-sensitive fluorescent dye, C-laurdan, was utilized to gain insights on the effect of membrane additives to the membrane structure. We report how the shell stiffness of NBs affects the pressure threshold (Pt) for the sudden amplification in the scattered acoustic signal from NBs. For narrow size NBs with 200 nm mean size, we find Pt to be between 123-245 kPa for the NBs with the most flexible membrane as assessed using C-Laurdan, 465-588 kPa for the NBs with intermediate stiffness and 588-710 kPa for the NBs with stiff membranes. Numerical simulations of the NB dynamics are in good agreement with the experimental observations confirming the dependence of acoustic response to shell properties, thereby substantiating further the development in engineering the shell of UCAs. The viscoelastic dependent threshold behavior can be utilized for significantly and selectively enhancing the diagnostic and therapeutic ultrasound applications of potent narrow size NBs.
Optimization of the bubble performance requires size isolation and accurate shell characterization using models that are not limited by linear assumptions. MBs and NBs with 2 different shell compositions (crosslinked (C) and non-crosslinked (NC)) were made in-house. NC shell is made with 4 different lipids including DBPC, DPPA,DPPE and DSPE-PEG2000 . C shell bubbles have additional ingredients that produce a UV polymerized crosslinked shell. Using the method of multiple differential centrifugations, two distinct size populations were separated with mean diameters of 2.9 μm for NC-MB and 3.3 μm for C-MB. The attenuation and sound speed of the diluted solutions were measured through transmission and reception method using one pair of PVDF transducers with center frequencies of 10 MHz and 100% BW at acoustic pressures of approximately 5 to 40 kPa. Our nonlinear model accounting for large amplitude MB oscillations was used to fit the measured attenuation and sound speed data at each pressure. As the pressure increased from 5 kPa to ≈ 50kPa, resonance frequency (f r ) of the NC-MBs with a mean diameter (MD) of 2.9 μm decreased from 9.1 to 5.9 MHz and f r of the C-MBs with (MD) of 3.3 μm decreased from 8 to 4.8 MHz. NC-NB solutions did not display any attenuation peak in the frequency range of 2-10 MHz, additionally; the measured attenuation was 5-10 times smaller than the MBs with the same shell composition. Fitting of the shell parameters suggests that crosslinking the shell results in ≈ 37% increase in stiffness and 50 % decrease in shell viscosity. The lower attenuation of the NBs even at very high concentrations may explain the enhancement in NB contrast ultrasound.
Our group recently presented a simple strategy using the non-ionic surfactant, Pluronic, as a size control excipient to produce nanobubbles in the 100-nm range, which exhibited stability and echogenicity on par with clinically available microbubbles. The objective of the present study was to evaluate biodistribution and extravasation of the Pluronic-stabilized lipid nanobubbles compared with microbubbles in 2 experimental tumor models in mice. Standard lipid-stabilized perfluoropropane bubbles (Pluronic L10) and lipid-stabilized perfluoropropane nanobubbles were intravenously injected into mice bearing either an orthotopic mouse breast cancer (BC4 T1) or subcutaneous mouse ovarian cancer (OVCAR-3) through the tail vein to perform perfusion dynamic studies. No significant differences between the nanobubble and microbubble groups were observed in the peak enhancement of the 3 tested regions (tumor, liver and kidney). However, the decay rates of nanobubble in the tumor and kidney of BC4 T1-bearing mice, as well as in mice with OVRCAR-3 tumors were significantly slower than those of the microbubble. To quantify extravasation, fluorescently labeled bubbles were intravenously injected into mice bearing the same tumors. Histologic analysis showed that nanobubbles were retained in tumor tissue to a greater extent compared with microbubbles in both tumor models at the 3-h time point. Our results demonstrate unique nanobubble behavior compared with microbubbles and support augmented application of these agents in ultrasound molecular imaging and drug delivery beyond the tumor vasculature.
Advancement of ultrasound molecular imaging applications requires not only a reduction in size of the ultrasound contrast agents (UCAs) but also a significant improvement in the in vivo stability of the shell-stabilized gas bubble. The transition from first generation to second generation UCAs was marked by an advancement in stability as air was replaced by a hydrophobic gas, such as perfluoropropane and sulfur hexafluoride. Further improvement can be realized by focusing on how well the UCAs shell can retain the encapsulated gas under extreme mechanical deformations. Here we report the next generation of UCAs for which we engineered the shell structure to impart much better stability under repeated prolonged oscillation due to ultrasound, and large changes in shear and turbulence as it circulates within the body. By adapting an architecture with two layers of contrasting elastic properties similar to bacterial cell envelopes, our ultrastable nanobubbles (NBs) withstand continuous in vitro exposure to ultrasound with minimal signal decay and have a significant delay on the onset of in vivo signal decay in kidney, liver, and tumor. Development of ultrastable NBs can potentially expand the role of ultrasound in molecular imaging, theranostics, and drug delivery.
We use a novel acoustic-based flow cytometer to detect individual nanobubbles flowing in a microfluidic channel using high-frequency ultrasound and photoacoustic waves. Each individual nanobubble ( or cluster of nanobubbles) flowing through the foci of high-frequency ultrasound ( center frequency 375 MHz) and nanosecond laser ( 532 nm) pulses interacts with both pulses to generate ultrasound backscatter and photoacoustic waves. We use in-house generated nanobubbles, made of lipid shells and octa fluoropropane gas core, to detect ultrasound backscatter signals using an acoustic flow cytometer. Nanobubble solutions sorted in size through differential centrifugation are diluted to 1: 10,000 v/v in phosphate buffered saline solution to maximize the probability that the detected signals are from individual nanobubbles. Nanobubble populations were sized using resonant mass measurement. Results show that the amplitude of the detected ultrasound backscatter signal is dependent on the nanobubble size. The average amplitude of the ultrasound backscatter signals from at least 950 nanobubbles with an average diameter of 150 nm, 225 nm, and 350 nm was 5.1+/-2.5 mV, 5.3+/-2.3 mV, and 6.4+/-1.8 mV, respectively. Similarly, we detected interleaved ultrasound backscatter and photoacoustic signals from nanobubbles tagged with Sudan Black B dye. The average amplitude of the ultrasound backscatter and photoacoustic signals from these black nanobubbles with an average diameter of 238 nm is 10+/-11 mV and 54+/-75 mV, respectively. The presence of the dye on the shell suppressed unique features seen in the ultrasound backscatter from the nanobubbles without dye. At present, there is no robust commercial technique able to analyze the ultrasonic response of individual nanobubbles. The acoustic flow cytometer can potentially be used to analyze physical parameters, such as size and ultrasonic response, of individual nanobubbles.
Nanobubble (NBs) contrast agents have the potential to augment the molecular imaging capabilities of ultrasound (US), especially in cancer imaging. However, as with most bubble-based formulations, these shell-stabilized perfluoropropane (C3F8) bubbles are fragile, last only several hours after self-assembly, and size isolation. Longer storage of the NB preparation leads to bubble dissolution. The short shelf-life after activation has limited broader bubble adoption and can hamper the diagnostic and therapeutic potential. Distribution of the NBs is also limited by the access to the amalgamator and centrifuge used for NB activation and isolation. In this work, we tested two simple freeze/thaw strategies for long term NB storage and examined their effect on NB size and concentration, initial acoustic activity, and US signal decay. Aliquoted NBs were either stored at -80°C for gradual cooling (GC-80), or flash frozen by submerging in liquid nitrogen prior storing at -80°C (FF-80). Our results suggest that NB suspension could be stored at -80°C for at least 28 days with only minor change in physical properties and acoustic performance. FF-80 NBs exhibited preserved NB size distribution and acoustic activity for over 28 days. GC-80 NBs showed a narrower size distribution but decrease in NB concentration at day 28. These differences are likely a result of shell composition changes induced by the freezing process, leading to less stable bubbles. The specific mechanism for the observed changes will be evaluated in future studies.
Ultrasound (US) is a widely used diagnostic imaging tool because it is inexpensive, safe, portable, and broadly accessible. Ultrasound contrast agents (UCAs) are employed to enhance backscatter echo and improve imaging contrast. The most frequently utilized UCAs are echogenic bubbles made with a phospholipid or protein-stabilized hydrophobic gas core. While clinically utilized, applications of UCAs are often limited by rapid signal decay (<5 min) in vivo under typical ultrasound imaging protocols. Here, we report on a formulation of lipid shell-stabilized perfluoropropane (C3F8) microbubbles and nanobubbles with a significantly prolonged in vivo stability. Microbubbles (875 ± 280 nm) of the target size were prepared by utilizing a multiple-step centrifugation cycle, while nanobubbles (299 ± 189 nm) were isolated from the activated vial using a single centrifugation step. To provide in-depth acoustic characterization of the new construct we evaluated the effect of size and concentration on their in vitro and in vivo performance. In vitro and in vivo characterization were carried out for a range of bubble concentrations normalized by total gas volume quantified via headspace gas chromatography/mass spectrometry (GC/MS). In vitro characterization revealed that nanobubbles at different concentrations are more consistently stable over time with the highest and lowest dilutions (50-fold decrease) only differing in US signal after 8 min exposure by 10.34%, while for microbubbles the difference was 86.46%. As expected, due to the difference in hydrodynamic diameter and scattering cross section difference, nanobubbles showed lower overall initial signal intensity. In vivo experiments showed that both microbubbles and nanobubbles with similar initial peak signal intensity are comparably stable over time with 66.8% and 60.6% remaining signal after 30 min, respectively. This study demonstrates that bubble concentration has significant effects on the persistence of both microbubbles and nanobubbles in vitro and in vivo, but the effects are more pronounced in larger bubbles. These effects should be taken into account when selecting the appropriate bubble parameters for future imaging applications.
A facile, one-step, and single-component fabrication of superhydrophobic and superoleophilic coating by electropolymerization of polythiophene on a stainless steel mesh is presented. The resulting coating has low surface energy and shows surface morphology bearing both micro- and nano-features without the need to add nanofillers, or pretreatment of the substrate to make it rough. The polythiophene coating also shows reversible wetting property (superhydrophobic to superhydrophilic, and vice versa) by electrochemical doping and dedoping. The coated mesh is shown to repel water of different pH (1, 7, and 14) and salt content. On the other hand, oil such as dichloromethane, gasoline, kerosene, dodecane, and crude oil can easily pass through the mesh. Therefore, the coated mesh is an excellent material for the separation of oil and water.