Acetylcholine (ACh) is a critical neurotransmitter influencing various neurophysiological functions. Despite its significance, quantitative methods with adequate spatiotemporal resolution for recording a single exocytotic ACh efflux are lacking. In this study, we introduce an ultrafast amperometric ACh biosensor that enables 50 kHz electrochemical recording of spontaneous single exocytosis events at axon terminals of differentiated cholinergic human SH-SY5Y neuroblastoma cells with sub-millisecond temporal resolution. Characterization of the recorded amperometric traces revealed seven distinct current spike types, each displaying variations in shape, time scale, and ACh quantities released. This finding suggests that exocytotic release is governed by complex fusion pore dynamics in these cells. The absolute number of ACh molecules released during exocytosis was quantified by calibrating the sensor through the electroanalysis of liposomes preloaded with varying ACh concentrations. Notably, the largest quantal release involving approximately 8000 ACh molecules likely represents full exocytosis, while a smaller release of 5000 ACh molecules may indicate partial exocytosis. Following a local administration of bafilomycin A1, a V-ATPase inhibitor, the cholinergic cells exhibited both a larger quantity of ACh released and a higher frequency of exocytosis events. Therefore, this ACh sensor provides a means to monitor minute amounts of ACh and investigate regulatory release mechanisms at the single-cell level, which is vital for understanding healthy brain function and pathologies and optimizing drug treatment for disorders.
Amperometry is an electrochemical method that can provide quantitative as well as kinetic information on neurotransmitter release from single exocytosis events and quantify the neurotransmitter content in single secretory vesicles. However, electrochemical recording of glutamate, the primary excitatory neurotransmitter in the brain, remains challenging due to the non-electroactive nature of glutamate. Hence, glutamate cannot be detected using conventional electrochemical methods but is feasible by creating an electrochemical glutamate biosensor. This can be achieved by immobilizing enzymes that catalyze glutamate at an electrode surface. The catalytic reaction of glutamate produces hydrogen peroxide, which can serve as an electrochemically detectable reporter molecule for glutamate detection. Although glutamate biosensors for a long time have suffered from a low temporal resolution (sub-seconds to seconds) and thus are too slow for detection of single sub-millisecond exocytosis events, we here present the technological development of a novel ultrafast (20 kHz) enzyme-based gold nanoparticle-coated amperometric microsensor designed for detection of glutamate release from synaptic vesicles. Our goal in this chapter is to describe the ultrafast glutamate biosensor design and explain how it can be manually fabricated for detecting and dissecting glutamate released from single synaptic vesicles. Additionally, we introduce a novel biosensor calibration method for quantifying the number of glutamate molecules released from isolated synaptic vesicles and single exocytosis events.
The fusion of vesicles and exocytosis release of neurotransmitters into the extracellular space for detection and chemical signal decoding by neighboring cells is the key process in neuronal communication. It is important to understand what regulates exocytosis because the amount of neurotransmitters released into the synaptic cleft has a direct impact on brain function such as cognition learning and memory as well as on brain malfunctions. Much success in molecular biology can be credited for the existence of simplified model systems. Therefore, for gaining deeper insights into the details of exocytosis and what controls vesicle-mediated neurotransmission, functional artificial cells for exocytosis have been developed that can be used for studying various biophysical aspects and roles of molecules affecting exocytosis, which is difficult to study in living cells. Here, we describe the design and fabrication of specific artificial cell models and how chemical measurements at these cells can be implemented for probing dynamics of the exocytosis fusion pore and its effect on the regulation of neurochemical release. We introduce bottom-up synthetic methods for constructing model cells using protein-free giant unilamellar vesicles (GUV) as starting material, which allows further tuning of molecular complexity in a manner that is not possible in living cells and therefore can be used for dissecting the role of essential molecular components affecting the exocytosis process. The experimental setup uses microscopy video recording, micromanipulation and microelectroinjection techniques, and amperometry detection to study neurotransmitter release from these cells mimicking exocytosis.
Enzymes conjugated to nanomaterials are used in the design of various biotechnologies. In development of biosensors, surface modifications with the enzyme glucose oxidase (GOx) serve to aid the detection of blood glucose. In order to optimize sensor effectiveness, the enzyme tertiary structure needs to be preserved upon immobilization to retain the enzyme´s catalytic activity. Due to the nature of GOx, it suffers from tendency to denature when immobilized at a solid surface, methods to optimize enzyme stability are of great importance. Here, we introduce the study of the interaction of GOx to the highly curved surface of 20 nm gold nanoparticles (AuNP) that shows how placing a monolayer of enzyme where the enzyme spreads thin at the AuNP surface still provides stable catalytic performance up to14 days compared to enzymes free in solution. Moreover, by increasing enzyme density and creating a molecularly crowded environment at the highly curved nanoparticle surface, which limits the size of the enzyme footprint for attachment, the activity per enzyme can be enhanced up to 300%. This is of great importance for implementing stable and sensitive sensor technologies that are constructed by enzyme-based nanoparticle scaffolds. Here, we show by using the conditions that maintain GOx structure and function when limiting the enzyme coating to an ultra-thin layer, the design and construction of ultrafast responding diagnostic sensor technology for glucose can be achieved, which is crucial for monitoring rapid fluctuations of for instance, glucose in the brain.
Neuronal transmission relies on electrical signals and the transfer of chemical signals from one neuron to another. Chemical messages are transmitted from presynaptic neurons to neighboring neurons through the triggered fusion of neurotransmitter-filled vesicles with the cell plasma membrane. This process, known as exocytosis, involves the rapid release of neurotransmitter solutions that are detected with high affinity by the postsynaptic neuron. The type and number of neurotransmitters released and the frequency of vesicular events govern brain functions such as cognition, decision making, learning, and memory. Therefore, to understand neurotransmitters and neuronal function, analytical tools capable of quantitative and chemically selective detection of neurotransmitters with high spatiotemporal resolution are needed. Electrochemistry offers powerful techniques that are sufficiently rapid to allow for the detection of exocytosis activity and provides quantitative measurements of vesicle neurotransmitter content and neurotransmitter release from individual vesicle events. In this review, we provide an overview of the most commonly used electrochemical methods for monitoring single-vesicle events, including recent developments and what is needed for future research.
We introduce an experimental method based upon a glass micropipette microinjection technique for generating a multitude of interconnected vesicles (IVs) in the interior of a single giant unilamellar phospholipid vesicle (GUV) serving as a cell model system. The GUV membrane, consisting of a mixture of soybean polar lipid extract and anionic phosphatidylserine, is adhered to a multilamellar lipid vesicle that functions as a lipid reservoir. Continuous IV formation was achieved by bringing a micropipette in direct contact with the outer GUV surface and subjecting it to a localized stream of a Ca 2+ solution from the micropipette tip. IVs are rapidly and sequentially generated and inserted into the GUV interior and encapsulate portions of the micropipette fluid content. The IVs remain connected to the GUV membrane and are interlinked by short lipid nanotubes and resemble beads on a string. The vesicle chain-growth from the GUV membrane is maintained for as long as there is the supply of membrane material and Ca 2+ solution, and the size of the individual IVs is controlled by the diameter of the micropipette tip. We also demonstrate that the IVs can be co-loaded with high concentrations of neurotransmitter and protein molecules and displaying a steep calcium ion concentration gradient across the membrane. These characteristics are analogous to native secretory vesicles and could, therefore, serve as a model system for studying secretory mechanisms in biological systems.
Analytical tools for direct quantitative measurements of glutamate, the principal excitatory neurotransmitter in brain, are lacking. Here, we introduce a new enzyme-based amperometric sensor technique for direct counting of the number of glutamate molecules stored inside single synaptic vesicles. An ultra-fast enzyme-based glutamate sensor is placed into a solution of isolated synaptic vesicles, which stochastically rupture at the sensor surface in a potential dependent manner by applying a constant negative potential. High-speed (10 kHz) amperometry is used to record sub-millisecond current spikes, which represent glutamate release from single vesicles that burst open. Glutamate quantification is achieved by a calibration curve that is based on measurements of glutamate release from vesicles pre-filled with various concentrations of glutamate. Our measurements show that a single synaptic vesicle encapsulates about 8000 glutamate molecules, which is comparable to the measured exocytotic quantal glutamate release in the nucleus accumbens of mouse brain tissue. Hence, this new methodology introduces the means to quantify ultra-small amounts of glutamate and to study synaptic vesicle physiology, pathogenesis and drug treatments for neuronal disorders where glutamate is involved.
Neuronal communication relies on vesicular neurotransmitter release from signaling neurons and detection of these molecules by neighboring neurons. Glutamate, the main excitatory neurotransmitter in the mammalian brain, is involved in nearly all brain functions. However, glutamate has suffered from detection schemes that lack temporal and spatial resolution allowed by electrochemistry. Here we show an amperometric, novel, ultrafast enzyme-based nanoparticle modified sensor, measuring random bursts of hundreds. to thousands of rapid spontaneous glutamate exocytotic release events at approximately 30 Hz frequency in the nucleus accumbens of rodent brain slices. Characterizing these single submillisecond exocytosis events revealed a great diversity in spike shape characteristics and size of quantal release, suggesting variability in fusion pore dynamics controlling the glutamate release by cells in this brain region. Hence, this novel biosensor allows recording of rapid single glutamate exocytosis events in the brain tissue and offers insight on regulatory aspects of exocytotic glutamate release, which is critical to understanding of brain glutamate function and dysfunction.
0 0 1 149 852 Gothenburg University 7 1 1000 14.0 Normal 0 false false false EN-US JA X-NONE /∗ Style Definitions ∗/ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size12.0pt; font-family:Cambria; mso-ascii-font-family:Cambria; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Cambria; mso-hansi-theme-font:minor-latin;} Glutamate, the main excitatory neurotransmitter in the mammalian brain, is involved in nearly all brain functions. However, glutamate has suffered from detection schemes that lack temporal and spatial resolution allowed by electrochemistry. Here we show an amperometric, novel ultra-fast enzyme-based nanoparticle modified sensor, measuring bursts of hundreds to thousands of rapid spontaneous glutamate exocytotic release events at approximately 30 Hz frequency in rodent brain slices. Characterizing these single sub-millisecond exocytosis events revealed a great diversity in spike shape characteristics and size of quantal release, suggesting variability in fusion pore dynamics controlling the glutamate release by these neurons. Hence, this novel biosensor allows recording of rapid single glutamate exocytosis events in the brain tissue and offers insight on regulatory aspects of exocytotic glutamate release, which is critical to understanding of brain glutamate function and in dysfunction.
Secretory vesicles are storage vehicles of neurotransmitters and hormones in secretory cells. Despite their important biological role, their complex composition and release mechanisms are not yet fully understood. To complement amperometry measurements and fluorescence-based methods to characterize neurotransmitter content of secretory vesicles, we here introduce a new method using surface plasmon resonance (SPR) to probe the intravesicular content of isolated intact large dense core vesicles from chromaffin cells and present how using this technique offers real time measurement of vesicle content release when subjected the isolated granules to high osmotic pressure. The observations from these SPR measurements confirm recent amperometric measurements at live chromaffin cells that neurotransmitters are released from vesicles when subjected to high osmotic pressure. Further, a comparison of volume exclusion measurements using SPR to the physical dimensions of the dense core vesicle size as determined by transmission electron microscopy imaging analysis, the molecular dimension of soluble volume versus the solid volume of membrane and dense protein matrix in intact vesicles was determined.
Amperometry recording of cells subjected to osmotic shock show that secretory cells respond to this physical stress by reducing the exocytosis activity and the amount of neurotransmitter released from vesicles in single exocytosis events. It has been suggested that the reduction in neurotransmitters expelled is due to alterations in membrane biophysical properties when cells shrink in response to osmotic stress and with assumptions made that secretory vesicles in the cell cytoplasm are not affected by extracellular osmotic stress. Amperometry recording of exocytosis monitors what is released from cells the moment a vesicle fuses with the plasma membrane, but does not provide information on the vesicle content before the vesicle fusion is triggered. Therefore, by combining amperometry recording with other complementary analytical methods that are capable of characterizing the secretory vesicles before exocytosis at cells is triggered offers a broader overview for examining how secretory vesicles and the exocytosis process are affected by osmotic shock. We here describe how complementing amperometry recording with intracellular electrochemical cytometry and transmission electron microscopy (TEM) imaging can be used to characterize alterations in secretory vesicles size and neurotransmitter content at chromaffin cells in relation to exocytosis activity before and after exposure to osmotic stress. By linking the quantitative information gained from experiments using all three analytical methods, conclusions were previously made that secretory vesicles respond to extracellular osmotic stress by shrinking in size and reducing the vesicle quantal size to maintain a constant vesicle neurotransmitter concentration. Hence, this gives some clarification regarding why vesicles, in response to osmotic stress, reduce the amount neurotransmitters released during exocytosis release. The amperometric recordings here indicate this is a reversible process and that vesicle after osmotic shock are refilled with neurotransmitters when placed cells are reverted into an isotonic environment.
Neuronal activity and brain glucose metabolism are tightly coupled, where triggered neurotransmission leads to a higher demand for glucose. To better understand the regulation of neuronal activity and its relation to high-speed metabolism, development of analytical tools that can temporally resolve the transients of vesicular neurotransmitter release and fluctuations of metabolites such as glucose in the local vicinity of the activated neurons is needed. Here we present an amperometric biosensor design for rapid co-detection of glucose and the neurotransmitter dopamine. The sensor is based on the immobilization of an ultra-thin layer of glucose oxidase on to a gold-nanoparticle-covered carbon fiber microelectrode. Our electrode, by altering the potential applied at the sensor surface, allows for the high-speed recording of both glucose and dopamine. We demonstrate that, even though glucose is electrochemically detected indirectly through the enzymatic product and the electroactive dopamine is sensed directly, when exposing the sensor surface to a mixture of the two analytes, fluctuations in glucose and dopamine concentrations can be visualized with similar speed and at a millisecond time scale. Hence, by minimizing the enzyme coating thickness at the sensor surface, dual detection of glucose and dopamine can be realized at the same sensor surface and at time scales necessary for monitoring fast metabolic alterations during neurotransmission.
In a wide variety of fundamental cell processes, such as membrane trafficking and apoptosis, cell membrane shape transitions occur concurrently with local variations in calcium ion concentration. The main molecular components involved in these processes have been identified; however, the specific interplay between calcium ion gradients and the lipids within the cell membrane is far less known, mainly due to the complex nature of biological cells and the difficultly of observation schemes. To bridge this gap, a synthetic approach is successfully implemented to reveal the localized effect of calcium ions on cell membrane mimics. Establishing a mimic to resemble the conditions within a cell is a severalfold problem. First, an adequate biomimetic model with appropriate dimensions and membrane composition is required to capture the physical properties of cells. Second, a micromanipulation setup is needed to deliver a small amount of calcium ions to a particular membrane location. Finally, an observation scheme is required to detect and record the response of the lipid membrane to the external stimulation. This article offers a detailed biomimetic approach for studying the calcium ion-membrane interaction, where a lipid vesicle system, consisting of a giant unilamellar vesicle (GUV) connected to a multilamellar vesicle (MLV), is exposed to a localized calcium gradient formed using a microinjection system. The dynamics of the ionic influence on the membrane were observed using fluorescence microscopy and recorded at video frame rates. As a result of the membrane stimulation, highly curved membrane tubular protrusions (MTPs) formed inside the GUV, oriented away from the membrane. The described approach induces the remodeling of the lipid membrane and MTP production in an entirely contactless and controlled manner. This approach introduces a means to address the details of calcium ion-membrane interactions, providing new avenues to study the mechanisms of cell membrane reshaping.
Chemical signaling strength during intercellular communication can be regulated by secretory cells through controlling the amount of signaling molecules that are released from a secretory vesicle during the exocytosis process. In addition, the chemical signal can also be influenced by the amount of neurotransmitters that is accumulated and stored inside the secretory vesicle compartment. Here, we present the development of analytical methodologies and cell model systems that have been applied in neuroscience research for gaining better insights into the biophysics and the molecular mechanisms, which are involved in the regulatory aspects of the exocytosis machinery affecting the output signal of chemical transmission at neuronal and neuroendocrine cells.
To immobilize enzymes at the surface of a nanoparticle-based electrochemical sensor is a common method to construct biosensors for non-electroactive analytes. Studying the interactions between the enzymes and nanoparticle support is of great importance in optimizing the conditions for biosensor design. This can be achieved by using a combination of analytical methods to carefully characterize the enzyme nanoparticle coating at the sensor surface while studying the optimal conditions for enzyme immobilization. From this analytical approach, it was found that controlling the enzyme coverage to a monolayer was a key factor to significantly improve the temporal resolution of biosensors. However, these characterization methods involve both tedious methodologies and working with toxic cyanide solutions. Here we introduce a new analytical method that allows direct quantification of the number of immobilized enzymes (glucose oxidase) at the surface of a gold nanoparticle coated glassy carbon electrode. This was achieved by exploiting an electrochemical stripping method for the direct quantification of the density and size of gold nanoparticles coating the electrode surface and combining this information with quantification of fluorophore-labeled enzymes bound to the sensor surface after stripping off their nanoparticle support. This method is both significantly much faster compared to previously reported methods and with the advantage that this method presented is non-toxic. Graphical abstract A new analytical method for direct quantification of the number of enzymes immobilized at the surface of gold nanoparticles covering a glassy carbon electrode using anodic stripping and fluorimetry.
Secretory cells respond to hypertonic stress by cell shrinking, which causes a reduction in exocytosis activity and the amount of signaling molecules released from single exocytosis events. These changes in exocytosis have been suggested to result from alterations in biophysical properties of cell cytoplasm and plasma membrane, based on the assumption that osmotic stress does not affect the secretory vesicle content and size prior to exocytosis. To further investigate whether vesicles in secretory cells are affected by the osmolality of the extracellular environment, we used intracellular electrochemical cytometry together with transmission electron microscopy imaging to quantify and determine the catecholamine concentration of dense core vesicles in situ before and after cell exposure to osmotic stress. In addition, single cell amperometry recordings of exocytosis at chromaffin cells were used to monitor the effect on exocytosis activity and quantal release when cells were exposed to osmotic stress. Here we show that hypertonic stress hampers exocytosis secretion after the first pool of readily releasable vesicles have been fused and that extracellular osmotic stress causes catecholamine filled vesicles to shrink, mainly by reducing the volume of the halo solution surrounding the protein matrix in dense core vesicles. In addition, the vesicles demonstrate the ability to perform adjustments in neurotransmitter content during shrinking, and intracellular amperometry measurements in situ suggest that vesicles reduce the catecholamine content to maintain a constant concentration within the vesicle compartment. Hence, the secretory vesicles in the cell cytoplasm are highly affected and respond to extracellular osmotic stress, which gives a new perspective to the cause of reduction in quantal size by these vesicles when undergoing exocytosis.
Neurons communicate via an essential process called exocytosis. Cholesterol, an abundant lipid in both secretory vesicles and cell plasma membrane can affect this process. In this study, amperometric recordings of vesicular dopamine release from two different artificial cell models created from a giant unilamellar liposome and a bleb cell plasma membrane, show that with higher membrane cholesterol the kinetics for vesicular release are decelerated in a concentration dependent manner. This reduction in exocytotic speed was consistent for two observed modes of exocytosis, full and partial release. Partial release events, which only occurred in the bleb cell model due to the higher tension in the system, exhibited amperometric spikes with three distinct shapes. In addition to the classic transient, some spikes displayed a current ramp or plateau following the maximum peak current. These post spike features represent neurotransmitter release from a dilated pore before constriction and show that enhancing membrane rigidity via cholesterol adds resistance to a dilated pore to re-close. This implies that the cholesterol dependent biophysical properties of the membrane directly affect the exocytosis kinetics and that membrane tension along with membrane rigidity can influence the fusion pore dynamics and stabilization which is central to regulation of neurochemical release.
We report the lithographic microfabrication of a movable thin film microelectrode array (MEA) probe consisting of 16 platinum band electrodes placed on top of a supporting borosilicate glass substrate. These 1.2 μm wide electrodes were tightly packed and positioned parallel in two opposite rows within a 20 μm × 25 μm square area and with a distance less than 10 μm from the edge of the glass substrate. We demonstrate the ability to control and place the probe in close proximity to the surface of adherent bovine chromaffin cells and to amperometrically record single exocytosis release events with high spatiotemporal resolution. The two-dimensional position of single exocytotic events occurring in the center gap area separating the two rows of MEA band electrodes and that were codetected by electrodes in both rows was determined by analysis of the fractional detection of catecholamine released between electrodes and exploiting random walk simulations. Hence, two-dimensional electrochemical imaging recording of exocytosis release between the electrodes within this area was achieved. Similarly, by modeling the current spikes codetected by parallel adjacent band electrodes positioned in the same electrode row, a one-dimensional imaging of exocytosis with submicrometer resolution was accomplished within the area. The one- and two-dimensional electrochemical imaging using the MEA probe allowed for high spatial resolution of exocytosis activity and revealed heterogeneous release of catecholamine at the chromaffin cell surface.
Electrochemical cytometry is a method developed recently to determine the content of an individual cell vesicle. The mechanism of vesicle rupture at the electrode surface involves the formation of a pore at the interface between a vesicle and the electrode through electroporation, which leads to the release and oxidation of the vesicle's chemical cargo. We have manipulated the membrane properties using excited fluorophores conjugated to lipids, which appears to make the membrane more susceptible to electroporation. We propose that by having excited fluorophores in close contact with the membrane, membrane lipids (and perhaps proteins) are oxidized upon production of reactive oxygen species, which then leads to changes in membrane properties and the formation of water defects. This is supported by experiments in which the fluorophores were placed on the lipid tail instead of the headgroup, which leads to a more rapid onset of vesicle opening. Additionally, application of DMSO to the vesicles, which increases the membrane area per lipid, and decreasing the membrane thickness result in the same enhancement in vesicle opening, which confirms the mechanism of vesicle opening with excited fluorophores in the membrane. Light-induced manipulation of membrane vesicle pore opening might be an attractive means of controlling cell activity and exocytosis. Additionally, our data confirm that in experiments in which cells or vesicle membranes are labeled for fluorescence monitoring, the properties of the excited membrane change substantially.
Exocytosis is the fundamental process by which cells communicate with each other. The events that lead up to the fusion of a vesicle loaded with chemical messenger with the cell membrane were the subject of a Nobel Prize in 2013. However, the processes occurring after the initial formation of a fusion pore are very much still in debate. The release of chemical messenger has traditionally been thought to occur through full distention of the vesicle membrane, hence assuming exocytosis to be all or none. In contrast to the all or none hypothesis, here we discuss the evidence that during exocytosis the vesicle-membrane pore opens to release only a portion of the transmitter content during exocytosis and then close again. This open and closed exocytosis is distinct from kiss-and-run exocytosis, in that it appears to be the main content released during regular exocytosis. The evidence for this partial release via open and closed exocytosis is presented considering primarily the quantitative evidence obtained with amperometry.