Background—Catheter-based intracoronary vascular endothelial growth factor (VEGF) gene transfer is a potential treatment for coronary heart disease. However, only limited data are available about local VEGF gene transfer given during angioplasty (PTCA) and stenting. Methods and Results—Patients with coronary heart disease (n=103; Canadian Cardiovascular Society class II to III; mean age, 58±6 years) were recruited in this randomized, placebo-controlled, double-blind phase II study. PTCA was performed with standard methods, followed by gene transfer with a perfusion-infusion catheter. Ninety percent of the patients were given stents; 37 patients received VEGF adenovirus (VEGF-Adv, 2×1010 pfu), 28 patients received VEGF plasmid liposome (VEGF-P/L; 2000 &mgr;g of DNA with 2000 &mgr;L of DOTMA:DOPE [1:1 wt/wt]), and 38 control patients received Ringer’s lactate. Follow-up time was 6 months. Gene transfer to coronary arteries was feasible and well tolerated. The overall clinical restenosis rate was 6%. In quantitative coronary angiography analysis, the minimal lumen diameter and percent of diameter stenosis did not significantly differ between the study groups. However, myocardial perfusion showed a significant improvement in the VEGF-Adv-treated patients after the 6-month follow-up. Some inflammatory responses were transiently present in the VEGF-Adv group, but no increases were detected in the incidences of serious adverse events in any of the study groups. Conclusions—Gene transfer with VEGF-Adv or VEGF-P/L during PTCA and stenting shows that (1) intracoronary gene transfer can be performed safely (no major gene transfer-related adverse effects were detected), (2) no differences in clinical restenosis rate or minimal lumen diameter were present after the 6-month follow-up, and (3) a significant increase was detected in myocardial perfusion in the VEGF-Adv-treated patients.
Lens opacity studies were performed using an electronic Lens Opacity Meter (Interzeag Opacity Lensmeter 701) in a population (n = 321) with ischaemic heart disease. These patients are participating in a trial targetting at the reduction of mortality and incidence of myocardial infarction using a cholesterol-lowering drug, simvastatin. A separate study to evaluate the reliability of the method showed good reproducibility. Repeated measurements after a short time-interval (2–10 days) gave statistically lower opacity values either due to a change in lens transparency or perhaps a change in pigment and cell dispersion in the acqueous caused by repeated mydriasis. Lens opacity values showed a highly significant positive correlation to age. Serum cholesterol, systolic blood pressure and smoking habits showed no significant correlations to the levels of lens opacity when adjustments for age were made.