The scientific equipment «Plasmakrystall–4» («PK–4») is designed to study complex (dusty) plasma under microgravity conditions aboard the International Space Station (ISS) and is a joint project of the European Space Agency (ESA) and Roscosmos. Scientific equipment «PK–4» is integrated into «European physiological modules» (EPM) rack, in the European laboratory module Columbus. Experiment control — automated, software-interactive, or manual from an on-board laptop and/or from a terminal in the ground control center. A low-pressure direct current discharge in noble gases in a glass tube is used to create a plasma at scientific equipment «PK–4». Microparticles of a given size are injected into the discharge to obtain a complex plasma. Two digital video cameras allow to trace individual microparticles inside the tube in phase space, which makes a complex plasma to be a good model for studying classical phenomena in condensed matter at the kinetic level. To monitor the plasma conditions, an integrated spectrometer and another video camera are used allowing to observe the plasma's own emission at different wavelengths. To study the reaction of microparticles to external forces, they can be exposed to radiation from a powerful laser, a gas stream, and also to thermophoretic force, i.e., by producing a given temperature gradient. Key words: complex plasmas, microparticles, soft matter, laser manipulation, microgravity, viscosity measurements, gas discharges, plasma diagnostics.
The Atmosphere-Space Interactions Monitor (ASIM) is an instrument suite on the International Space Station (ISS) for measurements of lightning, Transient Luminous Events (TLEs) and Terrestrial Gamma-ray Flashes (TGFs). Developed in the framework of the European Space Agency (ESA), it was launched April 2, 2018 on the SpaceX CRS-14 flight to the ISS. ASIM was mounted on an external platform of ESA's Columbus module eleven days later and is planned to take measurements during minimum 3 years.
New complex-plasma facility, Plasmakristall-4 (PK-4), has been recently commissioned on board the International Space Station. In complex plasmas, the subsystem of μm-sized microparticles immersed in low-pressure weakly ionized gas-discharge plasmas becomes strongly coupled due to the high (103-104 e) electric charge on the microparticle surface. The microparticle subsystem of complex plasmas is available for the observation at the kinetic level, which makes complex plasmas appropriate for particle-resolved modeling of classical condensed matter phenomena. The main purpose of PK-4 is the investigation of flowing complex plasmas. To generate plasma, PK-4 makes use of a classical dc discharge in a glass tube, whose polarity can be switched with the frequency of the order of 100 Hz. This frequency is high enough not to be felt by the relatively heavy microparticles. The duty cycle of the polarity switching can be also varied allowing to vary the drift velocity of the microparticles and (when necessary) to trap them. The facility is equipped with two videocameras and illumination laser for the microparticle imaging, kaleidoscopic plasma glow observation system and minispectrometer for plasma diagnostics and various microparticle manipulation devices (e.g., powerful manipulation laser). Scientific experiments are programmed in the form of scripts written with the help of specially developed C scripting language libraries. PK-4 is mainly operated from the ground (control center CADMOS in Toulouse, France) with the support of the space station crew. Data recorded during the experiments are later on delivered to the ground on the removable hard disk drives and distributed to participating scientists for the detailed analysis.
The European Space Research and Technology Center ESTEC, ESA’s premises in Noordwijk, The Netherlands, has a long lasting cooperation with the ZARM-FAB (Centre of Applied Space Technology and Microgravity—Drop Tower Operation and Service Company) in Bremen on the utilization of the Drop Tower for ground-based microgravity research and space hardware development studies. During the period January 2000 to December 2011 ESA will have procured in total some 840 drops addressing a variety of scientific and technological disciplines. The experiments are usually carried out in campaigns of 15 to 20 drops each, with an annual average of about 5 campaigns. The cooperation agreement between ESA and the ZARM-FAB includes experiment preparation advice by ZARM’s experts, the integration of the hardware into the drop capsule, dedicated safety reviews, the execution of the drop or catapult experiments, the post-flight payload de-integration as well as the handover of acquired data to the experimenters. The experiment hardware itself is provided by the scientists or has to be procured from sources outside of ESA’s drop tower utilization contract. ESA appreciates the cooperation of the ZARM-FAB in Bremen whose drop- and catapult facility provides excellent microgravity quality, is operated by a highly competent, flexible and extremely supportive expert team, allows campaign integration at relatively short notice throughout the entire year, offers real-time experiment operations and immediately after each drop delivers experiment results and provides on-site hardware modification possibilities.
We summarize the inflight performance of JEM–X, the X–ray monitor on the INTEGRAL mission during the initial ten months of operations. The JEM–X instruments have now been tuned to stable operational conditions. The performance is found to be close to the pre-launch expectations. The ground calibrations and the inflight calibration data permit to determine the instruments characteristics to fully support the scientific data analysis.
Aims. The Galactic bulge region is a rich host of variable high-energy point sources. Since 2005, February 17 we are monitoring the source activity in the Galactic bulge region regularly and frequently, i.e., about every three days, with the instruments onboard INTEGRAL. Thanks to the large field of view, the imaging capabilities and the sensitivity at hard X-rays, we are able to present for the first time a detailed homogeneous (hard) X-ray view of a sample of 76 sources in the Galactic bulge region.Methods. We describe the successful monitoring program and show the first results from the start of the monitoring up to 2006, April 21, i.e., for a period of about one and a half year, during three visibility seasons. We focus on the short (hour), medium (month) and long-term (year) variability in the hard X-ray bands, i.e., 20-60 keV and 60-150 keV. When available, we discuss the simultaneous observations in the soft X-ray, 3-10 keV and 10-25 keV, bands.Results. Almost all the sources in the Galactic bulge region we detect in the 20-60 keV and 60-150 keV bands are variable. During the last two and a half weeks of the third visibility season most of the known persistent (hard) X-ray sources in the Galactic Center region were not detected. Of our sample of sources, per visibility season we detect 32/33 sources in the 20-60 keV band and 8/9 sources in the 60-150 keV band above a signal to noise of 7. On average, we find per visibility season one active bright (greater than or similar to 100 mCrab, 20-60 keV) black-hole candidate X-ray transient and three active weaker (less than or similar to 25 mCrab, 20-60 keV) neutron star X-ray transients. Most of the time a clear anti-correlation can be seen between the soft and hard X-ray emission in some of the X-ray bursters. Hard X-ray flares or outbursts in X-ray bursters, which have a duration of the order of weeks are accompanied by soft X- ray drops. On the other hand, hard X-ray drops can be accompanied by soft X-ray flares/outbursts. During the course of our program we found a number of new sources, IGR J17354-3255, IGR 17453-2853, IGR J17454-2703, IGR J17456-2901b, IGR J17536-2339, and IGR J17541-2252. We report here on some of the high-energy properties of these sources.Conclusions. The high-energy light curves of all the sources in the field of view, and the high-energy images of the region, are made available through the WWW, as soon as possible after the observations have been performed, at http://isdc.unige.ch/Science/BULGE/.
The Galactic Bulge region is a rich host of variable high-energy point sources. These sources include bright and relatively faint X-ray transients, X-ray bursters, persistent neutron star and black-hole candidate binaries, X-ray pulsars, etc.. We have a program to monitor the Galactic Bulge region regularly and frequently with the gamma-ray observatory INTEGRAL As a service to the scientific community the high-energy light curves of all the active sources as well as images of the region are made available through the WWW. We show the first results of this exciting new program.
Accretion disk coronae are believed to account for X-ray emission in Active Galactic Nuclei ( AGNs). In this paper the observed emission is assumed to be due to a population of relativistic, non-thermal electrons ( e. g. produced in a flare) injected at the top of an accretion disk magnetic loop. While electrons stream along magnetic field lines, their energy distribution evolves in time essentially because of inverse Compton and synchrotron losses. The corresponding time-dependent emission due, in the X-ray energy range, to the inverse Compton mechanism, has been computed. Since the typical decay time of a flare is shorter than the integration time for data acquisition in the X-ray domain, the resulting spectrum is derived as the temporal mean of the real, time-dependent emission, as originated from a series of consecutive and identical flares. The model outcome is compared to both the broad band BeppoSAX X-ray data of the bright Seyfert 1 NGC 5548 and to a few general X-ray spectral properties of Seyfert 1s as a class. The good agreement between model and observations suggests that the presently proposed non-thermal, non-stationary model could be a plausible explanation of AGN X-ray emission as an alternative to thermal coronae models.