In this study we analyzed the blood compatibility of bacterial cellulose (BC) as a new biosynthetic material for use as a vascular graft. As reference materials we used expanded polytetrafluoroethylene (ePTFE) and poly(ethylene terephthalate) (PET) vascular grafts. These materials are in clinical use today. Tubes with inner diameters of both 4 (not PET) and 6 mm were tested. Heparin-coated PVC tubes (hepPVC) were used as a negative control. Platelet consumption and thrombin-antithrombin complex (TAT) were used as parameters of coagulation and for complement activation, sC3a and sC5b-9 were used. The investigated parameters were measured after 1-h exposure to freshly drawn human blood supplemented with a low dose of heparin in a Chandler loop system. The results showed that BC exhibits no significant difference in platelet consumption, as compared with PET 16 mm), ePTFE and hepPVC. The PET material consumed more platelets than any of the other materials. The TAT generation for 4 mm tubes was not significantly different between BC and the other materials. For 6 mm tubes, however, differences were observed between hepPVC and PET (p < 0.0001); BC and hepPVC (p = 0.0016); ePTFE and PET (p < 0.0001); BC and ePTFE (p = 0.0029); BC and PET (p = 0.0141). Surprisingly, considering the low platelet consumption, the complement activation parameters (sC3a and sC5b-9) were much higher for BC, as compared with the other materials for both 4 and 6 mm tubes. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 97A: 52-58,2011.
Nanocellulose (bacterial cellulose, BC), such as that produced by Acetobacter xylinum, has shown promising results as a replacement material for small diameter vascular grafts. The surface morphology of the lumen and mechanical properties of such tubes are crucial for their performance. The growth of a BC tube in a vertical fermentation bioreactor using silicone tubing for support and as an oxygen delivery membrane has not been studied in detail previously. Oxygen concentration and the number of bacteria added influence the production of the BC tubes. A dense and smooth luminal surface was formed after 4days on a 3mm silicone support. The bacteria were found to be in high concentration close to the silicon support and decreased in number further away. In the region with a high bacteria concentration, dense thin layers of BC were formed since the bacteria moved close together in this region. The presented observations were summarized in a theoretical model of BC tube growth.
Objectives. Many patients in need of bypass surgery lack graft material and current synthetic alternatives have poor performance. A 4 mm vascular graft composed of bacterial cellulose (BC) was developed and tested in pilot study in a large animal model. Design. BC is a biopolymer made by the bacteria acetobacter xylinum. BC grafts (n = 16) with 4 cm length and 4 mm internal diameter were implanted bilaterally in the carotid arteries of eight sheep. No long-term antithrombotic therapy was administered. Patency was assessed with ultrasound. Histology, immunohistochemistry, and electron microscopy were performed after explantation. Results. Fifty percent of the grafts occluded within two weeks. One animal died with patent grafts after 14 days. In the three remaining animals 5/6 grafts were patent after nine months. Two animals were followed 13 months after implantation with 3/4 grafts patent at explantation. All patent grafts had confluent endothelial-like cells. Conclusions. Biosynthetic small calibre vascular grafts made from BC can be patent for up to 13 months in sheep carotid arteries. BC is a potential material for small calibre grafts but patency in animal models needs to be improved before clinical studies can be planned.
Today, biomaterials such as polytetrafluorethylene (ePTFE) are used clinically as prosthetic grafts for vascular surgery of large vessels (>5 mm). In small diameter vessels, however, their performance is poor due to early thrombosis. Bacterial-derived cellulose (BC) is a new promising material as a replacement for blood vessels. This material is highly biocompatible in vivo but shows poor cell adhesion. In the native blood vessel, the endothelium creates a smooth non-thrombogenic surface. In order to sustain cell adhesion, BC has to be modified. With a novel xyloglucan (XG) glycoconjugate method, it is possible to introduce the cell adhesion peptide RGD (Arg-Gly-Asp) onto bacterial cellulose. The advantage of the XG-technique is that it is an easy one-step procedure carried out in water and it does not weaken or alter the fiber structure of the hydrogel. In this study, BC was modified with XG and XGRGD to asses primary human vascular endothelial cell adhesion, proliferation, and metabolism as compared with unmodified BC. This XG-RGD-modification significantly increased cell adhesion and the metabolism of seeded primary endothelial cells as compared with unmodified BC whereas the proliferation rate was affected only to some extent. The introduction of an RGD-peptide to the BC surface further resulted in enhanced cell spreading with more pronounced stress fiber formation and mature phenotype. This makes BC together with the XG-method a promising material for synthetic grafts in vascular surgery and cardiovascular research.
Although commonly used synthetic vascular grafts perform satisfactorily in large caliber blood vessels, they are prone to thrombosis in small diameter vessels. Therefore, small vessels might benefit from tissue engineered vascular grafts. This study evaluated bacterial cellulose (BC) as a potential biomaterial for biosynthetic blood vessels. We implanted the dorsal skinfold chambers in three groups of Syrian golden hamsters with BC (experimental group), polyglycolic acid, or expanded polytetrafluorethylene (control groups). Following implantation, we used intravital fluorescence microscopy, histology, and immunohistochemistry to analyze the biocompatibility, neovascularization, and incorporation of each material over a time period of 2 weeks. Biocompatibility was good in all groups, as indicated by the absence of leukocyte activation upon implantation. All groups displayed angiogenic response in the host tissue, but that response was highest in the polyglycolic acid group. Histology revealed vascularized granulation tissue surrounding all three biomaterials, with many proliferating cells and a lack of apoptotic cell death 2 weeks after implantation. In conclusion, BC offers good biocompatibility and material incorporation compared with commonly used materials in vascular surgery. Thus, BC represents a promising new biomaterial for tissue engineering of vascular grafts.
The search for a functional, small diameter (<5 mm) vascular graft has been ongoing for over 30 years, but yet there is no consistently reliable synthetic graft. The primary mechanisms of graft failure are intimal hyperplasia, poor blood flow and surface thrombogenicity. Bacterial cellulose (BC) became therefore a proposed new biosynthetic vascular graft material. Since conventional methods are not suited for coagulation measurements on BC, we have adapted the automated calibrated thrombin generation method for measurements of biomaterial-induced coagulation of BC as compared with clinically used graft materials i.e., expanded poly(tetrafluoroethylene) (ePTFE) and poly(ethyleneterephtalat) (PET). We have also visualized the coagulation propagation at the material surfaces. Thrombin generation experiments revealed dramatic differences between the materials tested. Both ePTFE and BC were found to generate longer lag times and ttpeak values than PET. Most importantly, BC was found to generate the lowest "peak", indicating a slower coagulation process at the surface. These results are also supported by the measurements of factor XIIa generation and analysis of surface coagulation times, which were detected in the following increasing order (mean ± SD): PET (27 ± 8 min) < BC (46 ± 9 min) < ePTFE (61 ± 21 min). Real-time measurement of coagulation seems to have the potential for becoming a powerful tool for evaluation of biomaterials for blood-contacting devices.
PURPOSE:Thrombin injection in femoral pseudoaneurysms has been suggested to be superior to traditional US-guided compression. Our aim was to evaluate results with compression therapy with special reference to use of thrombin in case of failure. We also studied 7 patients who underwent primary thrombin injection.MATERIAL AND METHODS:We retrospectively reviewed all (n=44) femoral artery pseudoaneurysms diagnosed at our department during October 1998-May 1999. US-guided compression with the Femostop device or US-guided thrombin injection (100-1000 IU) was the first choice according to the physicians' preference, followed by the other regime if the first choice was non-successful.RESULTS:Thirty-nine (89%) of the patients received anticoagulation treatment and/or concomitant antiplatelet drugs. Out of the 44 patients, 37 were treated with compression as the first choice. This regime was successful in 22 (59%). This group included 2 lesions that resolved spontaneously after initially failed compression and 1 deep venous thrombosis after treatment. The persistent 15 pseudoaneurysms after failed compression received thrombin injection, and it was also the primary therapy in 7 patients. Complete thrombosis within the pseudoaneurysm was immediately induced after treatment. One early recurrence required a second injection. No complication of thrombin was noted and no surgery was required.CONCLUSION:US-guided thrombin injection is an effective treatment for embolisation of pseudoaneurysms. The technique is superior to compression therapy.
Blood vessels are subjected to forces due to the flow. Endothelial cells (EC) are recipients, cross-talk with smooth muscle cells (SMC), and regulate physiology. It was hypothesized that both EC and SMC respond to shear stress, which alters the expression of factors in coagulation and fibrinolysis. Methods: A co-culture of human saphenous vein EC (HSVEC) and human saphenous vein SMC (HSVSMC) was exposed to shear, following which the cells were separated. Gene expression of tissue factor, thrombomodulin (TM), plasminogen activator inhibitor-1 (PAI-1), tissue plasminogen activator (tPA) and urokinase plasminogen activator (uPA) were analyzed with real-time RT-PCR. Protein expression was studied with ELISA. In HSVEC, the expression of PAI-1 (×2.1), tPA (×1.8), uPA (×1.6), tissue factor (×2.5) and TM (×1.9) was upregulated after 4 h of shear compared to controls. After 24 h of shear, expression was still upregulated in tPA (×2.3) and TM (×1.6). In HSVSMC, change in expression of PAI-1 (×2.1) was present after 4 h and in uPA (×2.1), and TM (×0.4) after 24 h. Both HSVEC and HSVSMC responded to shear, which led to altered expression of coagulation and fibrinolytic factors. This indicates that SMC, and interactions between EC and SMC, are more important in the regulation of vascular wall hemostasis than earlier studies have reported.
The scaffold is an essential component in tissue engineering. A novel method to prepare three-dimensional (3D) nanofibril network scaffolds with controlled microporosity has been developed. By placing paraffin wax and starch particles of various sizes in a growing culture of Acetobacter xylinum, bacterial cellulose scaffolds of different morphologies and interconnectivity were prepared. Paraffin particles were incorporated throughout the scaffold, while starch particles were found only in the outermost area of the resulting scaffold. The porogens were successfully removed after culture with bacteria and no residues were detected with electron spectroscopy for chemical analysis (ESCA) or Fourier transform infra-red spectroscopy (FT-IR). Resulting scaffolds were seeded with smooth muscle cells (SMCs) and investigated using histology and organ bath techniques. SMC were selected as the cell type since the main purpose of the resulting scaffolds is for tissue engineered blood vessels. SMCs attached to and proliferated on and partly into the scaffolds. Copyright (C) 2008 John Wiley & Sons, Ltd.
This chapter contains sections titled: Atherosclerosis Aneurysms Dissections Marfan's syndrome Ehlers-Danlos syndrome