Neutron time-of-flight diagnostics at the NIF were recently outfitted with Cherenkov detectors. A fused silica radiator delivers sub-nanosecond response time and is optically coupled to a microchannel plate photomultiplier tube with gain from ∼1 to 104. Capitalizing on fast time response and gamma-ray sensitivity, these systems can provide better than 30 ps precision for measuring first moments of neutron distributions. Generation of ab initio instrument response functions (IRFs) is critical to meet the <1% uncertainty needed. A combination of Monte Carlo modeling, benchtop characterization, and in situ comparison is employed. Close agreement is shown between the modeled IRFs and in situ measurements using the NIF's short-pulse advanced radiographic capability beams. First and second moments of neutron spectra calculated using ab initio IRFs agree well with established scintillator measurements. Next-step designs offer increased sensitivity and time-response.
Measuring the X-ray environment generated at the center of the NIF target chamber is a core capability required for understanding target implosions and other physics experiments. Recently an upgrade was performed to the recording systems employing modern digital technology and additional remote-control capabilities. Together, significantly decreasing manual setup burdens, increasing accuracy, stability and availability while contributing to shot rate improvement, overall efficiency and cost of operations reduction on NIF. We present the systems chosen, improved calibration techniques employed and some of the key features including the addition of self-test capabilities.
The newest Gas Cherenkov Detector (GCD-3) diagnostic has completed its Phase I commissioning/milestone at the National Ignition Facility (NIF). GCD-3 was fielded for several years at the Omega Laser Facility in its initial configuration, before being moved to the NIF. Installation at the NIF involved optimization of GCD-3 for the higher background environment and designing a new insertion carrier assembly. GCD-3 serves as the initial phase towards the implementation of the "Super GCD" (SGCD) at the NIF. During this phase of development GCD-3 took measurements from a re-entrant well, 3.9 meters from target chamber center (TCC). Plans to insert GCD-3 within 20 cm of TCC with a Target and Diagnostic Manipulator (TANDM) will be discussed. Data was collected using a Photomultiplier Tube (PMT) in combination with a Mach-Zehnder based recording system. These measurements were used to aid in shielding analysis, validate MCNP models, and fuel design efforts for the SGCD. Findings from the initial data will be covered extensively, including an in-depth look into sources of background and possible mitigation strategies. Ongoing development of phase two, the addition of an ultra-high bandwidth Pulse Dilatation Photomultiplier Tube (PD-PMT), will also be presented.
The goal of this paper is to outline the process for characterizing the S-parameters of passive two-port electrical devices to calculate the input signal from a measured output signal when standard two-port VNA measurements are not possible. For long cables such as those used at NIF to transmit analog electrical signals long distances from target diagnostics to their respective data digitizer, standard two-port VNA measurements cannot be used to determine the cables' transfer functions due to the large physical separations between the ports of the cables. Traditionally, this problem was addressed by recording input and output waveforms with two oscilloscopes and then comparing their spectral composition. A new method is to take reflection measurements at one port and substitute three known loads at the other port to generate a system of simultaneous equations that will allow for S21 to be quantified.
This paper covers the performance of a high speed analogue data transmission system. This system uses multiple Mach- Zehnder optical modulators to transmit and record fusion burn history data for the Gas Cherenkov Detector (GCD) on the National Ignition Facility. The GCD is designed to measure the burn duration of high energy gamma rays generated by Deuterium-Tritium (DT) interactions in the NIF. The burn duration of DT fusion can be as short as 10ps and the optical photons generated in the gas Cherenkov cell are measured using a vacuum photodiode with a FWHM of ~55ps. A recording system with a 3dB bandwidth of ≥10GHz and a signal to noise ratio of ≥5 for photodiode output voltage of 50mV is presented. The data transmission system uses two or three Mach-Zehnder modulators and an RF amplifier to transmit data optically. This signal is received and recorded by optical to electrical converts and a high speed digital oscilloscope placed outside of the NIF Target Bay. Electrical performance metrics covered include signal to noise ratio (SNR), signal to peak to peak noise ratio, single shot dynamic range, shot to shot dynamic range, system bandwidth, scattering parameters, are shown. Design considerations such as self-test capabilities, the NIF radiation environment, upgrade compatibility, Mach-Zehnder (MZ) biasing, maintainability, and operating considerations for the use of MZs are covered. This data recording system will be used for the future upgrade of the GCD to be used with a Pulse Dilation PMT, currently under development.
We present lessons learned from the fielding of various Mach-Zehnder (MZ) based diagnostic systems on the National Ignition Facility (NIF) and potential solutions. The DANTE X-ray diagnostic is the next in a series of applications for Mach-Zehnder based signal transport and acquisition systems on NIF and as such will incorporate many of these upgrades. In addition to extended dynamic-range performance and improved reliability, the upgrades presented also enable multiplexing of the signals from DANTE's 18 X-Ray Diodes (XRD) to economize on system cost and rack space. Previous deployments on other NIF diagnostics highlighted the necessity to decouple the input light intensity from the bias point of the Mach-Zehnder. Areas of concern including polarization, temperature, bias point and optical power level control will be addressed.
Received 28 February 2011DOI:https://doi.org/10.1103/PhysRevLett.106.109903© 2011 American Physical Society
We demonstrate the hohlraum radiation temperature and symmetry required for ignition-scale inertial confinement fusion capsule implosions. Cryogenic gas-filled hohlraums with 2.2 mm-diameter capsules are heated with unprecedented laser energies of 1.2 MJ delivered by 192 ultraviolet laser beams on the National Ignition Facility. Laser backscatter measurements show that these hohlraums absorb 87% to 91% of the incident laser power resulting in peak radiation temperatures of T(RAD)=300 eV and a symmetric implosion to a 100 μm diameter hot core.
The wavefront controller for the Keck Observatory AO system consists of two separate real-time control loops: a tip-tilt control loop to remove tilt from the incoming wavefront, and a deformable mirror control loop to remove higher-order aberrations. In this paper, we describe these control loops and analyze their performance using diagnostic data acquired during the integration and testing of the AO system on the telescope. Disturbance rejection curves for the controllers are calculated from the experimental data and compared to theory. The residual wavefront errors due to control loop bandwidth are also calculated from the data, and possible improvements to the controller performance are discussed.
The laser guide star adaptive optics system currently being developed for the Keck 2 telescope consists of several major subsystems: the optical bench, wavefront control, user interface and supervisory control, and the laser system. The paper describes the design and implementation of the wavefront control subsystem that controls a 349 actuator deformable mirror for high order correction and tip-tilt mirrors for stabilizing the image and laser positions.
A sodium-layer laser guide star beacon with high-order adaptive optics at Lick Observatory (Mount Hamilton, California) produced a factor of 2.4 intensity increase and a factor of 2 decrease in full width at half maximum for an astronomical point source, compared with image motion compensation alone. The image full widths at half maximum were identical for laser and natural guide stars (0.3 arc second). The Strehl ratio with the laser guide star was 65 percent of that with a natural guide star. This technique should allow ground-based telescopes to attain the diffraction limit, by correcting for atmospheric distortions.
Atmospheric turbulence severely limits the resolution of ground-based telescopes. Adaptive optics can correct for the aberrations caused by the atmosphere, but requires a bright wavefront reference source in close angular proximity to the object being imaged. Since natural reference stars of the necessary brightness are relatively rare, methods of generating artificial reference beacons have been under active investigation for more than a decade. In this paper, we report the first significant image improvement achieved using a sodium-layer laser guide star as a wavefront reference for a high-order adaptive optics system. An artificial beacon was created by resonant scattering from atomic sodium in the mesosphere, at an altitude of 95 km. Using this laser guide star, an adaptive optics system on the 3 m Shane Telescope at Lick Observatory produced a factor of 2.4 increase in peak intensity and a factor of 2 decrease in full width at half maximum of a stellar image, compared with image motion compensation alone. The Strehl ratio when using the laser guide star as the reference was 65% of that obtained with a natural guide star, and the image full widths at half maximum were identical, 0.3 are sec, using either the laser or the natural guide star. This sodium-layer laser guide star technique holds great promise for the world's largest telescopes.