Objective To explore the expression and effect of transforming growth factors-β1(TGF-β1) and heat shock protein(HSP47) on gluteal muscle contracture(GMC).Methods We collected contraction band and adjacent muscle from GMC patients and explored the expression of TGF-β1 and HSP47 using immunohistohemistry,reverse transcription and polymerase chain reaction(RT-PCR),and Western blot analysis.Results TGF-β1 and HSP47 were intensely expressed in fibroblast cells and vascular endothelial cells.The expression of them increased 8.1-fold and 3.6-fold at the mRNA level,respectively(P0.05).The same changes were found at the protein level,which increased 11.2-fold and 7.6-fold,respectively(P0.05).Conclusion Up-regulation of TGF-β1 and HSP47 may initiate fibrotic cascade in the gluteal muscles of GMC patients.
STUDY DESIGN:An in vitro biomechanical study. OBJECTIVE:To determine the initial stability and function of a new artificial joint in a cadaveric cervical spine model by comparing it with a conventional method. SUMMARY OF BACKGROUND DATA:Resection of the odontoid and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurologic complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. METHODS:There were 24 fresh human cadaveric cervical spines (C0-C3) randomly divided into 2 groups: group 1, resection of the odontoid with artificial atlanto-odontoid joint (AAOJ); and group 2, resection of the odontoid with Harms anterior atlantoaxial plate (Harms). For each specimen, the intact and resection of the odontoid underwent a flexibility test first, followed by the instrumented construct. Rotational angles of the C0-C3 segment were measured to study the immediate stability and function of resection of the odontoid and AAOJ, compared with the intact and resection of the odontoid and Harms. RESULTS:Compared with the intact state, resection of the odontoid and AAOJ resulted in a significant decrease in the range of motion (ROM) and neutral zone during flexion, extension, and lateral bending (P < 0.05); however, with regard to axial rotation, there was no significant difference in ROM (P > 0.05). Compared with resection of the odontoid and Harms, resection of the odontoid and AAOJ during flexion, extension, and lateral bending, there was no significant difference in ROM (P > 0.05). CONCLUSION:We have designed a new type of AAOJ for correcting atlantoaxial instability arising from C1 to C2 anterior decompression procedures. The unique aspect of this joint is that it restores, to a great extent, the C1-C2 axial rotation that is lost during current stabilization procedures.
Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P B 0.021) and NZ (P B 0.002) and a significantly increased stiffness (P \ 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P C 0.719), NZ (P C 0.580), and stiffness (P C 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities.