The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions comprise a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of rho(a) greater than or similar to 0.03 GeV/cm(3) and rho(a) greater than or similar to 0.004 GeV=cm(3) for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3 - 4.2 mu eV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.
We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (nu > 5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to beta similar to 10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.
Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.
We present results from the first experimental demonstration of a tunable thin-shell axion haloscope. This novel geometry decouples the overall volume of the cavity-based resonator from its resonant frequency, thereby evading the steep sensitivity degradation at high-frequencies. An aluminum $2.6$ L ($41$ $\lambda^3$) prototype which tunes from $7.1$ to $8.0$ GHz was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable $\mathrm{TM}$$_{010}$ mode is clearly identified with a room temperature quality factor, $Q$, of $\sim$$5,000$. The on-resonance $E$-field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of $0.57$ across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume $V\gg\lambda^3$. We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the post-inflationary axion parameter space ($\sim$$4$ to $\sim$$30$ GHz) at DFSZ sensitivity.
We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90 3.34 μeV, assuming a standard halo model with a local energy density of 0.45 GeV/cm^3 made up 100
DMRadio-m^3 is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10–200 MHz (41 neV/c^2 – 0.83 μeV/c^2) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m^3, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of two larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30–200 MHz can be achieved with a 3σ live scan time of 2.9 years.
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 {\mu}eV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.
We report the first result of a direct search for a Cosmic axion Background (CaB) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the CaB will be broad. We introduce a novel analysis strategy, which searches for a CaB induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a CaB originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband RF signals, such as other forms of a CaB or even high-frequency gravitational waves.
We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion-photon couplings above 10-13 Ge V-1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7-4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Standard Model itself including the Strong CP problem in QCD. Resulting experimental needs typically involve the measurement of very low energy impulses or low power periodic signals that are normally buried under large backgrounds. This report documents the findings of the 2023 Quantum Sensors for High Energy Physics workshop which identified enabling quantum information science technologies that could be utilized in future particle physics experiments, targeting high energy physics science goals.
The QCD (Quantum ChromoDynamics) axion emerged as one of the best-motivated dark matter candidates. In 2018, the Axion Dark Matter eXperiment (ADMX), one of the U.S. Department of Energy's "Gen 2" flagship dark-matter projects, demonstrated first sensitivity to the highly plausible "DFSZ" dark matter axion couplings over a small frequency range. We anticipate this development marks the first step in constructing yet more powerful experiments that can explore large swaths of the axion parameter space at high sensitivity and result in a discovery. But, realizing this requires advances in both our understanding of the theory and experiment design. Between 25 January and 27 January 2021, the "Axions Beyond Gen 2 Workshop" was held, where selected members of the community discussed our broad understanding of the QCD axion and charted a course for future experiments having sensitivity and mass reach well beyond the current "Gen 2" experiments. These proceedings are summaries of the topics presented and discussed.
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
Despite composing 85% of the matter in the universe, the exact nature of dark matter is still unknown. The possibility of wave-like dark matter and axions is driving a surge of new experiments that are vitalized by progress in quantum amplification and optics, microwave electronics, high magnetic fields, and cryogenics. We discuss the technology that enables such searches, and break down the experiments by their reliance on different axion couplings. We explain how the Axion Dark Matter eXperiment (ADMX) has achieved sensitivity to a particularly compelling class of dark matter candidates, known as DFSZ axions, in a narrow range of axion masses. Finally, with a new fleet of experiments arriving online, we present their goals to probe as yet unexplored parts of axion parameter space in the coming years.
Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66-3.1 μeV mass range with Dine-Fischler-Srednicki-Zhitnisky sensitivity [Du et al., Phys. Rev. Lett. 120, 151301 (2018) and Braine et al., Phys. Rev. Lett. 124, 101303 (2020)]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
We report the results from a haloscope search for axion dark matter in the 3.3-4.2 μeV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the Kim-Shifman-Vainshtein-Zakharov model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
CALIOPE, or CP ( T ) Aberrant Leptons in ortho-Positronium Experiment, is a tabletop search for fundamental symmetry violations, including CP- and CPT -violation, in ortho-positronium (o-Ps). We use a tagged 22 Na source adjacent to a cylinder of aerogel to generate o-Ps at the center of a cylindrical array of 24 NaI(Tl) bars. We search for CPT - violating angular correlations in the gamma rays emitted in the decay of o-Ps. With an angular acceptance of 75% of 4π, and the ability to acquire statistics over a longer period of time, CALIOPE will improve upon the limit set by previous experiments. The experimental setup can also be used in a search for CP -violation in o-Ps with the addition of an electromagnet. We describe the design of the experiment, results from a characterization of the systematics for the CPT - and CP -violating measurements, and a demonstration of the DAQ.