BACKGROUND:The aim of this study was to evaluate the timing and magnitude of global and regional right ventricular (RV) function by means of speckle tracking-derived strain in normal subjects and patients with RV dysfunction. METHODS:Peak longitudinal systolic strain (PLSS) and time to PLSS in 6 RV segments (the basal, mid, and apical segments of the RV free wall and septum) were obtained in 100 healthy volunteers and 76 patients with RV dysfunction by tracking speckles inside the myocardium using grayscale images. Global PLSS and time to PLSS were based on the average of the 6 regional values. RESULTS:There was a significant and close correlation between RV contractility as measured by PLSS and tricuspid annular plane systolic excursion (r = -0.83, P < .001). In normal subjects, PLSS was significantly greater in the free wall than in the septum (-28.7 + or - 4.1% vs -19.8 + or - 3.4%, P < .001), whereas time to PLSS was similar in the different regions of the right ventricle. In patients with RV dysfunction, global and regional PLSS was significantly less than in normal subjects (-13.7 + or - 3.6% vs -24.2 + or - 2.9%, P < .001), and a global PLSS cutoff value of -19% was helpful in distinguishing the two groups. Furthermore, time to PLSS in all of the RV septal segments and dispersion in RV contraction timing were significantly longer. Global PLSS in the patients with RV dysfunction was also significantly less in the presence of moderate to severe pulmonary hypertension (-12.7 + or - 3.6% vs -14.4 + or - 3.4%, P = .038). CONCLUSIONS:Speckle tracking not only makes it possible to quantify global RV function but also illustrates the physiology of RV contraction and the pattern of activation at regional level. Speckle tracking-derived strain could become an important new means of assessing and following up patients with impaired RV function and increased pulmonary pressure.
Prevalence of echocardiographically assessed mechanical dyssynchrony and consistency in detection of the latest mechanical left ventricular (LV) contracting region when different echocardiographic methods are used in the same patient remains ill-defined. The objectives of this study were to evaluate (1) the prevalence of intraventricular mechanical dyssynchrony and (2) consistency of latest mechanical LV contraction using a multiparametric approach derived from tissue Doppler imaging (TDI), 3-dimensional (3D) echocardiography, and speckle tracking in patients scheduled for cardiac resynchronization therapy (CRT). In 63 patients with heart failure scheduled for CRT, 2D echocardiography, TDI, 3D echocardiography, and speckle tracking were prospectively collected and analyzed. Prevalence of dyssynchrony was low for some tissue-velocity derived indexes (11%, 13%, and 43%) but was >or=80% for strain derived by TDI, for systolic dyssynchrony index by 3D echocardiography, and for longitudinal and radial strains by speckle tracking. Prevalence of dyssynchrony was 69% for maximum delay between anteroseptal and posterolateral walls by radial strain. Agreement among dyssynchrony indexes was generally low (kappa -0.02). Agreement of each of these echocardiographic indexes in determining, in the same patient with heart failure, the latest LV mechanical contraction site was also low (no site agreement in 77%). In conclusion, in a typical CRT population there is considerable variability among various techniques that assess prevalence of mechanical dyssynchrony and in identification of the latest mechanical LV contracting region.
Definition and validation of the ranges of normal values and agreement among echocardiographic measures of mechanical synchrony in healthy subjects are mostly lacking. The aims of this study were (1) to assess the ranges of normal values for 5 tissue Doppler imaging parameters, real-time 3-dimensional echocardiographic measures, and speckle-tracking measures of mechanical synchrony; (2) to evaluate interinstitutional variability; (3) to compare the ranges of normal values with those reported in previous research; and (4) to analyze the agreement among all parameters in the same healthy subject. Time to peak systolic velocity (Ts), the delay between Ts at the basal septal and lateral segments, peak velocity difference, strain derived by tissue Doppler imaging, Ts derived by tissue synchronization imaging, systolic synchrony index (SSI) derived by real-time 3-dimensional echocardiography, and longitudinal and radial strain derived by speckle tracking were prospectively collected and analyzed at 2 different institutions in 160 consecutive healthy subjects. The ranges of normal values, expressed as means +/- 2 SDs, were 30.32 +/- 29.36 ms for the SD of Ts, 15.51 +/- 99.88 ms for septal-lateral delay, 60.75 +/- 81.62 ms for peak velocity difference, 33.07 +/- 29.96 ms for tissue synchronization imaging, 34.16 +/- 23.26 ms for the SD of strain, 2.74 +/- 2.16% for SSI, 28.91 +/- 23.02 ms for the SD of longitudinal strain, and 10.4 +/- 6.31 ms for radial strain. There was large interinstitutional variability for all parameters. Three-dimensional SSI and radial strain were within the published upper range limit for healthy subjects. Ninety percent of healthy subjects were consistently classified to be synchronous by I parameter. With a composite index, more subjects than expected showed dyssynchrony (10% vs 2.5%). In conclusion, 3-dimensional SSI and radial strain were the most reproducible parameters and consistently discriminated normal healthy subjects from the cardiac resynchronization therapy volume responders. (C) 2009 Elsevier Inc. (Am J Cardiol 2009;103:136-142)
OBJECTIVES We sought to determine the feasibility of cardiac computed tomography (CT) to detect significant differences in the extent of left ventricular dyssynchrony in heart failure (HF) patients with wide QRS, HF patients with narrow QRS, and age-matched controls.BACKGROUND The degree of mechanical dyssynchrony has been suggested as a predictor of response to cardiac resynchronization therapy. There have been no published reports of dyssynchrony assessment with the use of CT.METHODS Thirty-eight subjects underwent electrocardiogram-gated contrast-enhanced 64-slice multidetector CT. The left ventricular endocardial and epicardial boundaries were delineated from short-axis images reconstructed at 10% phase increments of the cardiac cycle. Global and segmental CT dyssynchrony metrics that used changes in wall thickness, wall motion, and volume over time were assessed for reproducibility. We defined a global metric using changes in wall thickness as the dyssynchrony index (DI).RESULTS The DI was the most reproducible metric (interobserver and intraobserver intraclass correlation coefficients >= 0.94, p < 0.0001) and was used to determine differences between the 3 groups: HF-wide QRS group (ejection fraction [EF] 22 +/- 8%, QRS 163 +/- 28 ms), HF-narrow QRS (EF 26 +/- 7%, QRS 96 +/- 11 ms), and age-matched control subjects (EF 64 +/- 5%, QRS 87 +/- 9 ms). Mean DI was significantly different between the 3 groups (HF-wide QRS: 152 +/- 44 ms, HF-narrow QRS: 121 +/- 58 ms, and control subjects: 65 +/- 12 ms; p < 0.0001) and greater in the HF-wide QRS (p < 0.0001) and HF-narrow QRS (p = 0.005) groups compared with control subjects. We found that DI had a good correlation with 2-dimensional (r = 0.65, p = 0.012) and 3-dimensional (r = 0.68, p = 0.008) echocardiographic dyssynchrony.CONCLUSIONS Quantitative assessment of global CT-derived DI, based on changes in wall thickness over time, is highly reproducible and renders significant differences between subjects most likely to have dyssynchrony and age-matched control subjects. (J Am Coll Cardiol Img 2008; 1:772-81) (C) 2008 by the American College of Cardiology Foundation
The aim of this study was to evaluate the anatomic relation between the coronary sinus (CS), mitral annulus, and coronary arteries using 64-multislice computed tomography (MSCT) in patients presenting with a wide range of atrial volumes and left ventricular functions to determine the potential clinical use for percutaneous mitral annuloplasty (PMA). The MSCT data of 165 patients (age 63.65 +/- 12.89 years, 67.3% men) were evaluated. The following variables were measured: CS length, CS ostium area, area of the section of CS when it becomes great cardiac vein, area between CS and atrioventricular groove assessed in volume-rendered 3-dimensional images, axial angle measured as the angle between CS and mitral annulus assessed in axial section, mitral valve annulus (MVA) area, left atrium volume, and left circumflex artery/marginal branch-CS relation referring to mitral annulus. The correlation was inversed between the reduction of the axial angle and all following variables: enlargement of both left ventricular end-systolic (r = -0.429, p <0.001) and end-diastolic (r = -0.428, p <0.001) volumes, left atrial volume (r = -0.361, p <0.001), and MVA (r = -0.324, p <0.001). Similarly, there was inverse correlation between the reduction of the area between CS and atrioventricular groove, and enlargement of both left ventricular end-systolic (r = -0.376, p <0.001) and end-diastolic (r = -0.291, p <0.001) volumes, left atrial volume (r = -0.221, p = 0.001), and MVA (r = -0.155, p = 0.019). Of note, circumflex artery was located between CS and MVA in 77% of the patients, but in patients with severe mitral regurgitation CS crossed circumflex/marginal branch artery more frequently (97% of cases). In conclusion, a close proximity of the CS to the mitral annulus but also to circumflex artery is more likely to occur with left atrial and ventricular enlargement. Thus, MSCT should be considered as part of the selection process of potential candidate to PMA to avoid external compression of circumflex artery/marginal branch by the device.
BACKGROUND:Real-time 3-dimensional echocardiography (RT3DE) to visualize the coronary sinus (CS) was compared with multislice cardiac tomography (MSCT).METHODS:In all, 37 consecutive patients undergoing MSCT received RT3DE a few hours later. Group A (n = 22) had normal left ventricular dimension/function, whereas group B (n = 15) had heart failure.RESULTS:The CS could be visualized in both groups (91% and 93%) with a significantly larger diameter in B. Systolic CS diameter was always larger than diastolic, but patients with heart failure showed significantly less difference (7.6% +/- 4.2% vs 12.2% +/- 6.1%, P < .05). When systolic and diastolic measurements were possible, MSCT and RT3DE agreed (Lin R = -0.09 [95% confidence interval 0.73-0.93]) but less so from the proximal to mid/distal segments (Lin R 0.90, 0.61, 0.41, respectively). Observers learned the procedure in approximately 5 minutes.CONCLUSION:The CS can be visualized and quantitatively assessed by RT3DE in an easily learned procedure that agrees with MSCT results, especially in patients with heart failure.
BACKGROUND:The sequence of left ventricular (LV) systolic emptying is not completely understood. Using real-time 3-dimensional echocardiography, we investigated this sequence and LV synchronicity in physiological and pathological conditions.METHODS AND RESULTS:The study population consisted of 116 healthy volunteers, 20 top-level athletes, 35 patients with LV dysfunction, and 84 patients with LV dysfunction and left bundle-branch block (LBBB). We subdivided the LV into 16 volumetric segments for regional analysis and into apical, middle, and basal regions to calculate the mean of end-systolic times and the time to minimum systolic volume of each region. In healthy volunteers and in top-level athletes, the emptying systolic times increased smoothly from apex to base. These differences determined an apex-to-base time gradient in the LV emptying sequence. In patients with LV dysfunction and without LBBB, this gradient was maintained with a relatively higher LV dyssynchrony. However, in patients with LV dysfunction and LBBB, there was no clear sequence in LV emptying volumes, and this group had the highest LV dyssynchrony.CONCLUSIONS:Real-time 3-dimensional echocardiography tomographic slicing of the LV enables accurate analysis of LV emptying in physiological conditions and in conditions of LV dysfunction with and without electrical dyssynchrony. Progressive dilation of LV produces deterioration in LV synchronicity. However, it is the presence of LV dysfunction in combination with LBBB that determines the loss of the apex-to-base time gradient in LV emptying.
Relational changes in patients with heart failure (HF) among coronary sinus (CS), left atrial and ventricular volumes and coronary arteries have been neglected so far. The aim of this work was to study the spatial relationship among these structures through 64 multi-slice computed tomography (64 MSCT). The 64 MSCT data of individuals (age 65.1±11.5 years, 58.7% men) were evaluated. Subjects were divided in 3 groups: 28 controls, 18 patients with coronary artery disease but with a preserved left ventricular ejection fraction (LVEF) and 34 patients with symptomatic HF of any etiology. The following parameters were measured: CS length (CS-L), CS ostium area (CS-Oa), axial angle (AA) measured as the angle between CS and mitral annulus (MA) assessed in axial section, mitral annulus area (MAA), left atrium volume (LA V) and LCX (left circumflex artery)-CS relationship referring to MA. Results. Patients with depressed LVEF had significantly longer (p=0.000) and larger (p=0.002) CS; there was a strong correlation between the CS-L and LAV (r=0.60, p=0.000) and between CS-L and MAA (r=0.63, p=0.000). Patients with HF showed a more acute angle between CS and MA (p=0.000), with a good correlation between AA and MAA (r=−0.604, p=0.001) Finally, in the 77% of the patients, regardless to the LVEF, LCX was located between CS and MA. Conclusions. Our observations are consistent with a remodeling process of the CS in HF as shown by the increase of CS-L and CS-Oa. There was a shift of the CS from the posterior wall of left atrium to the atrio-ventricular groove due to increase of LAV and MAA. In the vast majority of patients LCX was located between CS and MV. These findings may have implications for applicability of percutaneous mitral annuloplasty.
The purpose of this study was to determine the feasibility of multislice computed tomography (MSCT) to assess the coronary sinus (CS) and its tributaries in patients who are undergoing cardiac resynchronization therapy and need a left ventricular (LV) lead revision. Preprocedural imaging modality, which may enable delineation of the cardiac venous anatomy in patients who need LV lead replacement, has not yet been evaluated. Ten patients with heart failure with previously implanted cardiac resynchronization therapy devices, who presented with worsening heart failure, were studied with MSCT and tissue Doppler imaging echocardiography before LV lead replacement. MSCT was performed to evaluate patency of the CS and coronary veins, and tissue Doppler imaging echocardiography assessed the region and the magnitude of mechanical dyssynchrony. An excellent concordance in the vein diameter, location, and status between MSCT and angiography was found. Apart from the need to perform a venoplasty in 1 patient and an unsuccessful lead explantation in another patient, all other anatomic issues were correctly predicted by MSCT. CS or vein occlusion were present in 4 patients, and in 3 of them surgical LV lead replacement was performed. Identification of a patent venous system enabling successful transvenous lead implantation was possible in 2 patients. Direct visualization of the proximity of the target vein to the phrenic nerve and the diaphragm guided lead selection and position in 4 patients. In conclusion, MSCT may be used to delineate the coronary venous anatomy in patients in whom LV lead replacement is needed to help strategize whether a transvenous or transthoracic approach may be preferred for LV lead revision. (c) 2007 Elsevier Inc. All rights reserved.
It gets more and more frequent to use oxygen consumption (VO2) to evaluate exercise capacity and response to treatment in heart failure patients. The amount of VO2 is due to ventilation, oxygen transport and muscle activity. No one of these single steps can define by itself VO2, but all these physiological functions are integrated each other. In this paper we examine the modifications of cardiac output, arteriovenous oxygen content difference, and the temporal behavior of their variations during exercise in heart failure. We specifically describe changes in VO2 during simulated altitude; we also contemplate mechanisms governing oxygen diffusion from capillary bed to mitochondria and critical capillary PO2 concept.