Background: Tidal recruitment/derecruitment (R/D) of collapsed regions in lung injury has been presumed to cause respiratory oscillations in the partial pressure of arterial oxygen (PaO2). These phenomena have not yet been studied simultaneously. We examined the relationship between R/D and PaO2 oscillations by contemporaneous measurement of lung-density changes and PaO2. Methods: Five anaesthetised pigs were studied after surfactant depletion via a saline-lavage model of R/D. The animals were ventilated with a mean fraction of inspired O-2 (FiO(2)) of 0.7 and a tidal volume of 10 ml kg(-1) Protocolised changes in pressure-and volume-controlled modes, inspiratory: expiratory ratio (I:E), and three types of breath-hold manoeuvres were undertaken. Lung collapse and PaO2 were recorded using dynamic computed tomography (dCT) and a rapid PaO2 sensor. Results: During tidal ventilation, the expiratory lung collapse increased when I: E <1 [mean (standard deviation) lung collapse = .7 (8.7)%; P<0.05], but the amplitude of respiratory PaO2 oscillations [ 2.2 (0.8) kPa] did not change during the respiratory cycle. The expected relationship between respiratory PaO2 oscillation amplitude and R/D was therefore not clear. Lung collapse increased during breath-hold manoeuvres at end-expiration and end-inspiration (14% vs 0.9-2.1%; P<0.0001). The mean change in PaO2 from beginning to end of breath-hold manoeuvres was significantly different with each type of breath-hold manoeuvre (P<0.0001). Conclusions: This study in a porcine model of collapse-prone lungs did not demonstrate the expected association between PaO2 oscillation amplitude and the degree of recruitment/derecruitment. The results suggest that changes in pulmonary ventilation are not the sole determinant of changes in PaO2 during mechanical ventilation in lung injury.
Arterial oxygen partial pressure can increase during inspiration and decrease during expiration in the presence of a variable shunt fraction, such as with cyclical atelectasis, but it is generally presumed to remain constant within a respiratory cycle in the healthy lung. We measured arterial oxygen partial pressure continuously with a fast intra-vascular sensor in the carotid artery of anaesthetized, mechanically ventilated pigs, without lung injury. Here we demonstrate that arterial oxygen partial pressure shows respiratory oscillations in the uninjured pig lung, in the absence of cyclical atelectasis (as determined with dynamic computed tomography), with oscillation amplitudes that exceeded 50 mmHg, depending on the conditions of mechanical ventilation. These arterial oxygen partial pressure respiratory oscillations can be modelled from a single alveolar compartment and a constant oxygen uptake, without the requirement for an increased shunt fraction during expiration. Our results are likely to contribute to the interpretation of arterial oxygen respiratory oscillations observed during mechanical ventilation in the acute respiratory distress syndrome.
Background. The Bohr method is a technique to determine airways deadspace using a tracer gas such as carbon dioxide or nitrogen. It is based on the assumption that the inspired concentration of the tracer gas is constant throughout inspiration. However, in some lung function measurement techniques where inspired concentration of the tracer gas may be required to vary, or where rapid injection of the tracer gas is made in real time, uniform inspired concentration is difficult or impossible to achieve, which leads to inaccurate estimation of deadspace using the Bohr equation. One such lung function measurement technique is the inspired sinewave technique. Objective. In this paper, we proposed a modification of the Bohr method, relaxing the requirement of absolute uniformity of tracer concentration in the inspired breath. Method. The new method used integration of flow and concentration. A computer algorithm sought an appropriate value of deadspace to satisfy the mass balance equation for each breath. A modern gas mixing apparatus with rapid mass flow controllers was used to verify the procedure. Result. Experiments on a tidally ventilated bench lung showed that the new method estimated dead space within 10% of the actual values whereas the traditional Bohr deadspace gave more than 50% error. Conclusion. The new method improved the accuracy of deadspace estimation when the inspired concentration is not uniform. This improvement would lead to more accurate diagnosis and more accurate estimations of other lung parameters such as functional residual capacity and pulmonary blood flow.
The inspired sinewave technique is a noninvasive method to measure airway dead space, functional residual capacity, pulmonary blood flow, and lung inhomogeneity simultaneously. The purpose of this paper was to assess the repeatability and accuracy of the current device prototype in measuring functional residual capacity, and also participant comfort when using such a device. To assess within-session repeatability, six sinewave measurements were taken over two-hour period in 17 healthy volunteers. To assess day-to-day repeatability, measurements were taken over 16 days in 3 volunteers. To assess accuracy, sinewave measurements were compared to body plethysmography in 44 healthy volunteers. Finally, 18 volunteers who experienced the inspired sinewave device, body plethysmography and spirometry were asked to rate the comfort of each technique on a scale of 1-10. The repeatability coefficients for dead space, functional residual capacity, and blood flow were 48.7 ml, 0.48L, and 2.4L/min respectively. Bland-Altman analyses showed a mean BIAS(SD) of -0.68(0.42)L for functional residual capacity when compared with body plethysmography. 14 out of 18 volunteers rated the inspired sinewave device as their preferred technique. The repeatability and accuracy of functional residual capacity measurements were found to be as good as other techniques in the literature. The high level of comfort and the non-requirement of patient effort meant that, if further refined, the inspired sinewave technique could be an attractive solution for difficult patient groups such as very young children, elderly, and ventilated patients.
Wereport the monitoring of oxygen partial pressure (pO(2)) in the liquid phase in cell cultures with a luminescence quenching based fiber optic oxygen sensor. The sensitivity of the fiber optic oxygen sensor was evaluated in the gas phase and the sensor was calibrated in the liquid phase before monitoring cell culture pO(2) with a luminescence phase detection system. In these experiments, porcine kidney (PK-15) cells were used as the cell samples and the experimental results showed that the sensor is suitable for monitoring of pO(2) in gas and liquid phases. In addition, we found that in cell cultures exposed to ambient air, measured pO(2) values in the liquid phase differed according to the different cell densities in the culture. Under conditions of low pO(2) in the gas phase and high cell density, the cell metabolism reduces the pO(2) in the liquid phase to values lower than those of the gas headspace, indicating that the cellular oxygen uptake rate exceeds the oxygen diffusion rate. Therefore there is a need for direct pO(2) monitoring in a cell culture, particularly in static high density cell culture systems where oxygen mass transfer is limited.
Very fast sensors that are able to track rapid changes in oxygen partial pressure (PO2) in the gas and liquid phases are increasingly required in scientific research particularly in the life sciences. Recent interest in monitoring very fast changes in the PO2 of arterial blood in some respiratory failure conditions is one such example. Previous attempts to design fast intravascular electrochemical oxygen sensors for use in physiology and medicine have failed to meet the criteria that are now required in modern investigations. However, miniature photonic devices are capable of meeting this need. In this article, we present an inexpensive polymer type fibre-optic, oxygen sensor that is two orders of magnitude faster than conventional electrochemical oxygen sensors. It is constructed with biologically inert polymer materials and is both sufficiently small and robust for direct insertion in to a human artery. The sensors were tested and evaluated in both a gas testing chamber and in a flowing liquid test system. The results showed a very fast T90 response time, typically circa 20 ms when tested in the gas phase, and circa 100 ms in flowing liquid. (C) 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Biosensors are very important tools in biomedical and clinical research. They are becoming a part of day-to-day healthcare. With the development of technology some nanomaterials such as carbon nanomaterial, which have special building blocks and come with some unique electronic and optical properties, have been implemented into biosensor devices. Carbon nanotubes (CNTs) are carbon nanomaterial comprising rolled-up cylinders of carbon monolayers. The properties of the sensing matrix materials can be modified in such a way that relevant molecules can be detected with high sensitivity and selectivity. In this paper we report experimental results on a CNT/polymer nanocomposite and a luminescence quenching based optical oxygen sensor. The results show that the time response of the sensors can be optimized by adding CNTs into sensing matrix.
Conventional methods for monitoring lung function usually require complex gas analysers and the co-operation of the patient.Therefore, they are not compatible with the crowded environment of the Intensive Care Unit (ICU) or operating theatre, where the patient co-operation is usually impossible.However, it is precisely these patients that would benefit the most from accurate monitoring of lung function.This paper develops a compact and non-invasive system for the measurement and monitoring of lung function in a clinical setting, such as lung volume, airway dead space volume, and pulmonary blood flow.In contrast with conventional methods, the compact apparatus and non-invasive nature of the proposed method allow it to be used in the ICU, as well as in general clinical settings.The system implements a breath-by-breath computer ventilation model using a non-invasive technique, in which a tracer gas is injected into the patient's inspired breath.Experimental results are shown for both an artificial lung and a healthy volunteer.Our findings show that the proposed technique has several advantages over the conventional method for the estimation of lung function.
Introduction: Inspired Sinewave is a novel technique to measure dead space, alveolar volume, pulmonary blood flow, and lung inhomogeneity noninvasively. It does not require patient effort and therefore can be applied to young children, elderly, and ventilated patients with ease.Method: In this paper, we describe a brief introduction to the principle of the technique, which involves forcing inspired concentrations to oscillate sinusoidally and measuring responding expired concentrations. Then, we give some updates to the recent developments of the device. These include comparison studies with body plethysmography for functional residual capacity measurement, and with echocardiography for cardiac output measurement.Result and discussion: The results show that the inspired sinewave technique achieves comparable accuracy and repeatability with the "gold standard" body plethysmography method withConclusion: The success of these studies is a big step forward to make this novel device a useful clinical tool. The technology is patented and future work includes forming collaboration with an industry partner to bring the technology to commercialisation.
Background There is considerable interest in oxygen partial pressure (Po2) monitoring in physiology, and in tracking Po2 changes dynamically when it varies rapidly. For example, arterial Po2 ( PaO2) can vary within the respiratory cycle in cyclical atelectasis (CA), where PaO2 is thought to increase and decrease during inspiration and expiration, respectively. A sensor that detects these PaO2 oscillations could become a useful diagnostic tool of CA during acute respiratory distress syndrome (ARDS). Methods We developed a fibreoptic Po2 sensor (<200 µm diameter), suitable for human use, that has a fast response time, and can measure Po2 continuously in blood. By altering the inspired fraction of oxygen ( FIO2) from 21 to 100% in four healthy animal models, we determined the linearity of the sensor's signal over a wide range of PaO2 values in vivo. We also hypothesized that the sensor could measure rapid intra-breath PaO2 oscillations in a large animal model of ARDS. Results In the healthy animal models, PaO2 responses to changes in FIO2 were in agreement with conventional intermittent blood-gas analysis (n=39) for a wide range of PaO2 values, from 10 to 73 kPa. In the animal lavage model of CA, the sensor detected PaO2 oscillations, also at clinically relevant PaO2 levels close to 9 kPa. Conclusions We conclude that these fibreoptic PaO2 sensors have the potential to become a diagnostic tool for CA in ARDS.
The development of a clinically useful fiber-optic oxygen sensor based on oxygen fluorescence quenching is described in this paper. The fiber optic oxygen sensor was formed by coating a thin polymer matrix, which contains an oxygen sensitive fluorophore, on the tapered end of a polymer optical fiber. Three acrylate polymers have been used for the matrix, and the sensitivity and time-response of the oxygen sensors were tested. The results showed that the sensitivity and time response of the sensors can be modified using different polymer matrices. Using these modifications, a very fast time response of the polymer fiber-based oxygen sensor could be readily achieved and the fastest T10-90 response time were <100 ms.
Conventional methods for estimating cardiopulmonary variables usually require complex gas analyzers and the active co-operation of the patient. Therefore, they are not compatible with the crowded environment of the intensive care unit (ICU) or operating theatre, where patient co-operation is typically impossible. However, it is these patients that would benefit the most from accurate estimation of cardiopulmonary variables, because of their critical condition. This paper describes the results of a collaborative development between an anesthesiologists and biomedical engineers to create a compact and non-invasive system for the measurement of cardiopulmonary variables such as lung volume, airway dead space volume, and pulmonary blood flow. In contrast with conventional methods, the compact apparatus and non-invasive nature of the proposed method allow it to be used in the ICU, as well as in general clinical settings. We propose the use of a non-invasive method, in which tracer gases are injected into the patient's inspired breath, and the concentration of the tracer gases is subsequently measured. A novel breath-by-breath tidal ventilation model is then used to estimate the value of a patient's cardiopulmonary variables. Experimental results from an artificial lung demonstrate minimal error in the estimation of known parameters using the proposed method. Results from analysis of a cohort of 20 healthy volunteers (within the Oxford University Hospitals NHS Trust) show that the values of estimated cardiopulmonary variables from these subjects lies within the expected ranges. Advantages of this method are that it is non-invasive, compact, portable, and can perform analysis in real time with less than 1 min of acquired respiratory data.
Two challenges in the management of Acute Respiratory Distress Syndrome are the difficulty in diagnosing cyclical atelectasis, and in individualising mechanical ventilation therapy in real-time. Commercial optical oxygen sensors can detect P-ao2 oscillations associated with cyclical atelectasis, but are not accurate at saturation levels below 90%, and contain a toxic fluorophore. We present a computer-controlled test rig, together with an in-house constructed ultra-rapid sensor to test the limitations of these sensors when exposed to rapidly changing P-O2 in blood in vitro. We tested the sensors' responses to simulated respiratory rates between 10 and 60 breaths per minute. Our sensor was able to detect the whole amplitude of the imposed P-O2 oscillations, even at the highest respiratory rate. We also examined our sensor's resistance to clot formation by continuous in vivo deployment in non-heparinised flowing animal blood for 24 h, after which no adsorption of organic material on the sensor's surface was detectable by scanning electron microscopy. (C) 2013 The Authors. Published by Elsevier B.V. All rights reserved.
The development and construction of a tapered-tip fibre-optic fluorescence based oxygen sensor is described. The sensor is suitable for fast and real-time monitoring of human breathing. The sensitivity and response time of the oxygen sensor were evaluated in vitro with a gas pressure chamber system, where oxygen partial pressure was rapidly changed between 5 and 15 kPa, and then in vivo in five healthy adult participants who synchronized their breathing to a metronome set at 10, 20, 30, 40, 50, and 60 breaths min–1. A Datex Ultima medical gas analyser was used to monitor breathing rate as a comparator. The sensor's response time in vitro was less than 150 ms, which allows accurate continuous measurement of inspired and expired oxygen pressure. Measurements of breathing rate by means of our oxygen sensor and of the Datex Ultima were in strong agreement. The results demonstrate that the device can reliably resolve breathing rates up to 60 breaths min–1, and that it is a suitable cost-effective alternative for monitoring breathing rates and end-tidal oxygen partial pressure in the clinical setting. The rapid response time of the sensor may allow its use for monitoring rapid breathing rates as occur in children and the newborn.
Inspired Sinewave is a novel technique to measure dead space, alveolar volume, and pulmonary blood flow noninvasively. In this paper, we describe a brief introduction to the principle of the technique, which involves forcing inspired concentrations to oscillate sinusoidally and measuring responding expired concentrations. Then, we give some updates to the recent developments of the device. These include accuracy and robustness studies of the device on bench lungs and volunteers, and study of lung volume change from sitting to supine. The success of these studies is a big step forward to make this novel device a useful clinical tool. The paper concludes with a description of future work.