Background Uncontrolled haemorrhage is life-threatening in trauma, necessitating optimised haemostatic strategies. The silicate kaolin-based QuikClot® Combat Gauze™ (CG) is an established haemostatic dressing, whereas polyphosphate (PolyP), a naturally occurring degradable inorganic polymer, has shown haemostatic potential. This study compares PolyP and CG for control of severe arterial bleeding and maintenance of haemostasis after haemorrhagic shock under volume-driven (V) versus catecholamine-driven (Cat) resuscitation in a swine model of lethal arterial injury. Methods Twenty-seven pigs received a standardised 3.6-mm femoral arterial defect causing free haemorrhage and shock (MAP ≤ 60 mmHg). PolyP (n = 14) or CG (n = 13) was applied with external compression (200 mmHg, 5 min). Resuscitation used either hydroxyethyl starch (V) or norepinephrine (Cat) to reach MAP ≥ 60 mmHg or baseline MAP in a 2 × 2 design: PolyP+V (n = 9), CG+V (n = 8), PolyP+Cat (n = 5), CG+Cat (n = 5). Primary endpoints were 120-min survival and post-interventional blood loss. Results With V resuscitation, survival was similar (PolyP 6/9 vs CG 4/8; p = 0.6372). With Cat resuscitation, survival was higher with CG than PolyP (5/5 vs 1/5; p = 0.0476). Post-interventional blood loss did not differ. First-pass haemostasis was comparable in V (CG 87.5% vs PolyP 88.9%) and Cat (CG 80% vs PolyP 60%) models (p > 0.9999 for both). Systolic pressure at failure was approximately 80 mmHg in all groups. Conclusion PolyP and CG provided comparable early haemorrhage control and prevention of post-interventional blood loss, supporting PolyP as a topical haemostatic alternative.
Objective: Ischemia/reperfusion can impair microcirculatory blood flow. It remains unknown whether colloids are superior to crystalloids for restoration of microcirculatory blood flow during ischemia/reperfusion injury. We tested the hypothesis that goal-directed colloid - compared to crystalloid - therapy improves small intestinal, renal, and hepatic microcirculatory blood flow in pigs with ischemia/reperfusion injury. Methods: This was a randomized trial in 32 pigs. We induced ischemia/reperfusion by supra-celiac aortic-crossclamping. Pigs were randomized to receive either goal-directed isooncotic hydroxyethyl-starch colloid or balanced isotonic crystalloid therapy. Microcirculatory blood flow was measured using Laser-Speckle-ContrastImaging. The primary outcome was small intestinal, renal, and hepatic microcirculatory blood flow 4.5 h after ischemia/reperfusion. Secondary outcomes included small intestinal, renal, and hepatic histopathological damage, macrohemodynamic and metabolic variables, as well as specific biomarkers of tissue injury, renal, and hepatic function and injury, and endothelial barrier function. Results: Small intestinal microcirculatory blood flow was higher in pigs assigned to isooncotic hydroxyethylstarch colloid therapy than in pigs assigned to balanced isotonic crystalloid therapy (768.7 (677.2-860.1) vs. 595.6 (496.3-694.8) arbitrary units, p = .007). There were no important differences in renal (509.7 (427.2-592.1) vs. 442.1 (361.2-523.0) arbitrary units, p = .286) and hepatic (604.7 (507.7-701.8) vs. 548.7 (444.0-653.3) arbitrary units, p = .376) microcirculatory blood flow between groups. Pigs assigned to colloid - compared to crystalloid - therapy also had less small intestinal, but not renal and hepatic, histopathological damage. Conclusions: Goal-directed isooncotic hydroxyethyl-starch colloid - compared to balanced isotonic crystalloid - therapy improved small intestinal, but not renal and hepatic, microcirculatory blood flow in pigs with ischemia/ reperfusion injury. Whether colloid therapy improves small intestinal microcirculatory blood flow in patients with ischemia/reperfusion needs to be investigated in clinical trials.
Background: Spinal cord ischemia (SCI) is a severe complication after fenestrated/branched endovascular repair (f/bEVAR). The underlying causes of SCI are still under investigation. This study aimed to evaluate intra- and early post-operative parameters that may affect SCI evolution. Methods: A single-center retrospective analysis was conducted including SCI patients with complete anesthesiologic records (1 January 2011 to 31 December 2023). Values of intra-operative glucose, hemoglobin, lactate, activated clotting time (ACT), and the need for transfusion were collected. The cohort was compared to a matched cohort of non-SCI patients. Results: Fifty-one patients with SCI and complete anesthesiologic records were included (mean age: 69.8 ± 6.2 years; 39.2% male). Intra-operative glucose value < 110 mg/dL (AUC: 0.73; sensitivity 91%, specificity of 83%) and hemoglobin value > 8.5 mg/dL (AUC: 0.61; sensitivity 83%, specificity 78%) were protective for Grade 3 SCI. Twenty-three patients with SCI were matched to 23 patients without SCI. SCI patients presented significantly higher glucose levels intra-operatively (glucose mean value: SCI 150 ± 46 mg/dL vs. non-SCI: 122 ± 30 mg/dL, p = 0.005). ACT (SCI 259 ± 31 svs. non-SCI 288 ± 28 s, p = 0.001), volume input (SCI 4030 ± 1430 mL vs. non-SCI 3020 ± 113 mL, p = 0.009), and need for transfusion (SCI: 52.5% vs. 4.3%, p < 0.001) were related to SCI. Higher glucose levels were detected among patients with SCI, at 24 (SCI: 142 ± 30 mg/dL vs. non-SCI: 118 ± 26 mg/dL, p=0.004) and 48 h (SCI: 140 ± 29 mg/dL vs. non-SCI: 112 ± 20 mg/dL, p < 0.001) post-operatively. Conclusions: SCI is a multifactorial complication after f/bEVAR. Intra-operative and early post-operative glucose levels may be related to SCI evolution. Targeted glucose < 110 mg/dL may be protective for Grade 3 SCI.
Purpose Postoperative complications after major liver surgery are common. Thoracic epidural anesthesia may provide beneficial effects on postoperative outcome. We strove to compare postoperative outcomes in major liver surgery patients with and without thoracic epidural anesthesia. Methods This was a retrospective cohort study in a single university medical center. Patients undergoing elective major liver surgery between April 2012 and December 2016 were eligible for inclusion. We divided patients into two groups according to whether or not they had thoracic epidural anesthesia for major liver surgery. The primary outcome was postoperative hospital length of stay, i.e., from day of surgery until hospital discharge. Secondary outcomes included 30-day postoperative mortality and major postoperative complications. Additionally, we investigated the effect of thoracic epidural anesthesia on perioperative analgesia doses and the safety of thoracic epidural anesthesia. Results Of 328 patients included in this study, 177 (54.3%) received thoracic epidural anesthesia. There were no clinically important differences in postoperative hospital length of stay (11.0 [7.00–17.0] vs. 9.00 [7.00–14.0] days, p = 0.316, primary outcome), death (0.0 vs. 2.7%, p = 0.995), or the incidence of postoperative renal failure (0.6 vs. 0.0%, p = 0.99), sepsis (0.0 vs. 1.3%, p = 0.21), or pulmonary embolism (0.6 vs. 1.4%, p = 0.59) between patients with or without thoracic epidural anesthesia. Perioperative analgesia doses — including the intraoperative sufentanil dose (0.228 [0.170–0.332] vs. 0.405 [0.315–0.565] μg·kg −1 ·h −1 , p < 0.0001) — were lower in patients with thoracic epidural anesthesia. No major thoracic epidural anesthesia-associated infections or bleedings occurred. Conclusion This retrospective analysis suggests that thoracic epidural anesthesia does not reduce postoperative hospital length of stay in patients undergoing major liver surgery — but it may reduce perioperative analgesia doses. Thoracic epidural anesthesia was safe in this cohort of patients undergoing major liver surgery. These findings need to be confirmed in robust clinical trials.
The NASA Cloud, Aerosol, and Monsoon Processes Philippines Experiment (CAMP2Ex) employed the NASA P-3, Stratton Park Engineering Company (SPEC) Learjet 35, and a host of satellites and surface sensors to characterize the coupling of aerosol processes, cloud physics, and atmospheric radiation within the Maritime Continent's complex southwest monsoonal environment. Conducted in the late summer of 2019 from Luzon, Philippines, in conjunction with the Office of Naval Research Propagation of Intraseasonal Tropical Oscillations (PISTON) experiment with its R/V Sally Ride stationed in the northwestern tropical Pacific, CAMP2Ex documented diverse biomass burning, industrial and natural aerosol populations, and their interactions with small to congestus convection. The 2019 season exhibited El Nino conditions and associated drought, high biomass burning emissions, and an early monsoon transition allowing for observation of pristine to massively polluted environments as they advected through intricate diurnal mesoscale and radiative environments into the monsoonal trough. CAMP2Ex's preliminary results indicate 1) increasing aerosol loadings tend to invigorate congestus convection in height and increase liquid water paths; 2) lidar, polarimetry, and geostationary Advanced Himawari Imager remote sensing sensors have skill in quantifying diverse aerosol and cloud properties and their interaction; and 3) high-resolution remote sensing technologies are able to greatly improve our ability to evaluate the radiation budget in complex cloud systems. Through the development of innovative informatics technologies, CAMP2Ex provides a benchmark dataset of an environment of extremes for the study of aerosol, cloud, and radiation processes as well as a crucible for the design of future observing systems.
Acute myocardial injury is common after noncardiac surgery and associated with mortality. Impaired intraoperative cardiovascular dynamics are a risk factor for acute myocardial injury. Optimizing intraoperative cardiovascular dynamics may thus reduce acute myocardial injury. We aimed to investigate the effect of intraoperative personalized goal-directed hemodynamic management on the incidence of acute myocardial injury. We hypothesized that personalized goal-directed hemodynamic management reduces the incidence of acute myocardial injury compared to routine hemodynamic management in high-risk patients having major abdominal surgery. We performed a post-hoc secondary analysis of a randomized clinical trial including 180 high-risk major abdominal surgery patients that were randomized to personalized goal-directed hemodynamic management or routine hemodynamic management. We compared the incidences of acute myocardial injury-defined according to the Fourth Universal Definition of Myocardial Infarction (2018)-between patients randomized to personalized goal-directed hemodynamic management or routine hemodynamic management by calculating the relative and absolute risk reduction together with 95% Wald confidence intervals and P values. Acute myocardial injury occurred in 4 of 90 patients (4%) in the personalized goal-directed hemodynamic management group and in 12 of 90 patients (13%) in the routine hemodynamic management group (relative risk: 0.33, 95% confidence interval: 0.11 to 0.99, P = 0.036; absolute risk reduction: - 9%, 95% confidence interval: - 17% to - 0.68%, P = 0.034). In this post-hoc secondary analysis, intraoperative personalized goal-directed hemodynamic management reduced the incidence of acute myocardial injury compared to routine hemodynamic management in high-risk patients having major abdominal surgery. This needs to be confirmed in larger prospective trials.
Background: Hypotension during induction of anaesthesia is associated with organ injury. Continuous arterial pressure monitoring might help reduce hypotension. We tested the hypothesis that continuous intra-arterial compared with intermittent oscillometric arterial pressure monitoring reduces hypotension during induction of anaesthesia in noncardiac surgery patients. Methods: In this single-centre randomised trial, 242 noncardiac surgery patients in whom intra-arterial arterial pressure monitoring was planned were randomised to unblinded continuous intra-arterial or to intermittent oscillometric arterial pressure monitoring (with blinded intra-arterial arterial pressure monitoring) during induction of anaesthesia. The primary endpoint was the area under a mean arterial pressure (MAP) of 65 mm Hg within the first 15 min of induction of anaesthesia. Secondary endpoints included areas under MAP values of 60, 50, and 40 mm Hg and durations of MAP values <65, <60, <50, and <40 mm Hg. Results: There were 224 subjects available for analysis. The median (25th-75th percentile) area under a MAP of 65 mm Hg was 15 (2-36) mm Hg . min in subjects assigned to continuous intra-arterial monitoring and 46 (7-111) mm Hg . min in subjects assigned to intermittent oscillometric monitoring (P<0.001). Subjects assigned to continuous intra-arterial monitoring had smaller areas under MAP values of 60, 50, and 40 mm Hg and shorter durations of MAP values <65, <60, <50, and <40 mm Hg than subjects assigned to intermittent oscillometric monitoring. Conclusion: Continuous intra-arterial arterial pressure monitoring reduces hypotension during induction of anaesthesia compared with intermittent oscillometric arterial pressure monitoring in noncardiac surgery patients. In patients for whom an arterial catheter is planned, clinicians might therefore consider inserting the arterial catheter before rather than after induction of anaesthesia.
Objective: Spinal cord injury induced by ischemia/reperfusion is a devastating complication of aortic repair. Despite developments for prevention and treatment of spinal cord injury, incidence is still considerably high majorly impacting patient outcome. Microcirculation is paramount for tissue perfusion and oxygen supply and often dissociated from macrohemodynamic parameters used to guide resuscitation. Effects of fluids vs. vasopressors in the setting of hemodynamic resuscitation on spinal cord microperfusion are unknown. Aim of this study was to compare the effects of vasopressor and fluid resuscitation on spinal cord microperfusion in a translational acute pig model of hemorrhagic shock induced ischemia/reperfusion injury. Methods: We designed this study as prospective randomized explorative large animal study. We induced hemorrhagic shock in 20 pigs as a model of global ischemia/reperfusion injury. We randomized animals to receive either fluid or vasopressor resuscitation. We measured spinal cord microperfusion using fluorescent microspheres as well as laser-Doppler probes. We monitored and analyzed macrohemodynamic parameters and cerebrospinal fluid pressure.Results: Spinal cord microperfusion decreased following hemorrhagic shock induced ischemia/reperfusion injury. Both fluids and vasopressors sufficiently restored spinal cord microperfusion. There were no important changes between groups (percentage changes compared to baseline: fluids 14.0 (0.31-27.6) vs. vasopressors 24.3 (8.12-40.4), p = .340). However, cerebrospinal fluid pressure was higher in animals receiving fluid resuscitation (percentage changes compared to baseline: fluids 27.7 (12.6-42.8) vs. vasopressors-5.56 ((-19.8)-8.72), p = .003). Microcirculatory resuscitation was in line with improvements of macrohemodynamic parameters. Conclusions: Both, fluids and vasopressors, equally restored spinal cord microperfusion in a porcine acute model of hemorrhagic shock induced ischemia/reperfusion injury. However, significant differences in cerebrospinal fluid pressure following resuscitation were present. Future studies should evaluate these effects in perfusion disruption induced ischemia/reperfusion conditions of microcirculatory deterioration.
Objectives: The SPIDER technique for hybrid thoracoabdominal aortic aneurysm repair can avoid thoracotomy and extracorporeal circulation. To improve technical feasibility and safety, the new Thoracoflo graft, consisting of a proximal stent graft connected to a 7-branched abdominal prosthesis, was evaluated in a pig model for technical feasibility testing, before implantation in humans. Methods: Retroperitoneal exposure of the infradiaphragmatic aorta, including visceral and renal arteries, was performed in 7 pigs (75-85 kg). One iliac branch was temporarily attached to the distal aorta to maintain retrograde visceral and an-tegrade iliac perfusion after deployment of the thoracic stent graft segment (SPI-DER technique). The proximal stent-grafted segment was deployed in the thoracic aorta via direct aortic puncture over the wire without fluoroscopy. The graft was deaired before flow via the iliac side branch to the visceral and iliac ar-teries was established. Visceral, renal, and lumbar arteries were subsequently su-tured to the corresponding side branches of the graft. Technical feasibility, operating and clamping time, blood flow, and tissue perfusion in the related organs were evaluated before implantation and after 3 and 6 hours using transit-time flow measurement and fluorescent microspheres. Final angiography or postprocedural computed tomography angiography were performed.Results: Over-the-wire graft deployment was successful in 6 animals without he-modynamic alteration (P 1/4 n.s.). In 1 pig, the proximal stent graft section migrated as the guidewire was not removed, as recommended, before release of the proximal fixation wire. Angiography and computed tomography scan confirmed successful graft implantation and transit-time flow measurement confirmed good visceral and iliac blood flow. Fluorescent microspheres confirmed good spinal cord perfu-sion.Conclusions: Over-the-wire implantation of the Thoracoflo graft using the SPIDER technique is feasible in a pig model. No fluoroscopy was required. For safe implan-tation, it is mandatory to follow the single steps of implantation. (JTCVS Techniques 2022;15:1-8)
Dynamic parameters of preload have been widely recommended to guide fluid therapy based on the principle of fluid responsiveness and with regard to cardiac output. An equally important aspect is however to also avoid volume-overload. This accounts particularly when capillary leakage is present and volume-overload will promote impairment of microcirculatory blood flow. The aim of this study was to evaluate, whether an impairment of intestinal microcirculation caused by volume-load potentially can be predicted using pulse pressure variation in an experimental model of ischemia/reperfusion injury. The study was designed as a prospective explorative large animal pilot study. The study was performed in 8 anesthetized domestic pigs (German landrace). Ischemia/reperfusion was induced during aortic surgery. 6 h after ischemia/reperfusion-injury measurements were performed during 4 consecutive volume-loading-steps, each consisting of 6 ml kg −1 bodyweight −1 . Mean microcirculatory blood flow (mean Flux) of the ileum was measured using direct laser-speckle-contrast-imaging. Receiver operating characteristic analysis was performed to determine the ability of pulse pressure variation to predict a decrease in microcirculation. A reduction of ≥ 10% mean Flux was considered a relevant decrease. After ischemia–reperfusion, volume-loading-steps led to a significant increase of cardiac output as well as mean arterial pressure, while pulse pressure variation and mean Flux were significantly reduced (Pairwise comparison ischemia/reperfusion-injury vs. volume loading step no. 4): cardiac output (l min −1 ) 1.68 (1.02–2.35) versus 2.84 (2.15–3.53), p = 0.002, mean arterial pressure (mmHg) 29.89 (21.65–38.12) versus 52.34 (43.55–61.14), p < 0.001, pulse pressure variation (%) 24.84 (17.45–32.22) versus 9.59 (1.68–17.49), p = 0.004, mean Flux (p.u.) 414.95 (295.18–534.72) versus 327.21 (206.95–447.48), p = 0.006. Receiver operating characteristic analysis revealed an area under the curve of 0.88 (CI 95% 0.73–1.00; p value < 0.001) for pulse pressure variation for predicting a decrease of microcirculatory blood flow. The results of our study show that pulse pressure variation does have the potential to predict decreases of intestinal microcirculatory blood flow due to volume-load after ischemia/reperfusion-injury. This should encourage further translational research and might help to prevent microcirculatory impairment due to excessive fluid resuscitation and to guide fluid therapy in the future.
This study presents seasonal trends in marine tropospheric aerosol arising from the interplay between physical and biological processes in the Western Antarctic Peninsula (WAP). Remote sensing‐based studies focused on aerosol distribution and links to chlorophyll‐ a concentration and sea ice predominantly use passive sensor retrievals of aerosol optical properties. However, these data are subject to cloud presence, signal uncertainties, and lack of retrievals in high latitude wintertime. To address these concerns, we have developed a method of quantifying tropospheric marine aerosol with the NASA Cloud‐Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO), which we term marine aerosol optical depth (MAOD). MAOD may be retrieved in nighttime conditions of high‐latitude winter and is devoid of cloud contamination, thereby advancing upon prior aerosol optical depth (AOD) measurements linked with biogenic aerosol. To examine trends in tropospheric marine aerosol, we undertook a multi‐year remote sensing analysis in the Bellingshausen Sea from 2006 to 2018. A seasonal increase in MAOD was observed alongside a seasonal increase in chl‐ a and sea ice melt, suggesting a biogenic component to aerosol presence. To the best of our knowledge, this study is also the first to further distinguish a late winter to early spring temporal MAOD signal, likely tied to an aerosol source from either venting of biogenic aerosol from breaks in sea ice or to sea spray/salt aerosol resulting from pulses in wind speed. Our work extends upon previous findings of AOD in polar environments and now more fully characterizes interactions during polar winter.
Purpose Dynamic indicators of preload currently only do reflect preload requirements of the left ventricle. To date, no dynamic indicators of right ventricular preload have been established. The aim of this study was to calculate dynamic indicators of right ventricular preload and assess their ability to predict ventricular volume responsiveness. Materials and methods The study was designed as experimental trial in 20 anaesthetized pigs. Micro-tip catheters and ultrasonic flow probes were used as experimental reference to enable measurement of right ventricular stroke volume and pulse pressure. Hypovolemia was induced (withdrawal of blood 20 ml/kg) and thereafter three volume-loading steps were performed. ROC analysis was performed to assess the ability of dynamic right ventricular parameters to predict volume response. Results ROC analysis revealed an area under the curve (AUC) of 0.82 (CI 95% 0.73–0.89; p < 0.001) for right ventricular stroke volume variation (SVV RV ), an AUC of 0.72 (CI 95% 0.53–0.85; p = 0.02) for pulmonary artery pulse pressure variation (PPV PA ) and an AUC of 0.66 (CI 95% 0.51–0.79; p = 0.04) for pulmonary artery systolic pressure variation (SPV PA ). Conclusions In our experimental animal setting, calculating dynamic indicators of right ventricular preload is possible and appears promising in predicting volume responsiveness.
Objectives: Although mortality associated with pancreatic surgery has decreased dramatically, high morbidity rates are still of major concern. Enhanced recovery after surgery (ERAS) protocols have been developed for most major abdominal surgeries. Specific guidelines also for duodenopancreatectomy have been published, but mainly by extrapolating data collected from colorectal surgery.
OBJECTIVES Cerebrospinal fluid (CSF) drainage is routinely utilized to mitigate perioperative and postoperative spinal cord ischaemia in open and endovascular thoraco-abdominal aortic aneurysm repair to prevent permanent paraplegia. Clinical decision-making in the vulnerable perioperative period, however, is still based on limited clinical and experimental data. Our aim was to investigate the isolated effect of CSF pressure elevation on spinal cord perfusion in an established large animal model. METHODS Ten juvenile pigs with normal (native) arterial inflow (patent segmental arteries and collaterals) underwent iatrogenic CSF pressure elevation (×2, ×3, ×4 from their individual baseline pressure). Each pressure level was maintained for 30 min to mimic clinical response time. After the quadrupling of CSF pressure, the dural sac was slowly depressurized against gravity allowing CSF pressure to passively return to baseline values. Measurements were taken 30 and 60 min after normalization, and microspheres for regional blood flow analysis were injected at each time point. RESULTS Spinal cord perfusion decreased significantly at all mid-thoracic to lumbar cord segments at the doubling of CSF pressure and declined to values <53% compared to baseline when pressure was quadrupled. Normalizing CSF pressure led to an intense hyperperfusion of up to 186% at the cervical level and 151% within the lumbar region. CONCLUSIONS CSF pressure elevation results in a relevant impairment of spinal cord blood supply. Close perioperative and postoperative monitoring of CSF pressure is crucial for maintaining sufficient spinal cord perfusion. Radical and rapid withdrawal of CSF is followed by significant hyperperfusion in all spinal cord segments and may lead to 'drainage-related' iatrogenic reperfusion injury-aggravating the risk of delayed spinal cord injury-and should therefore be avoided.
Spinal cord injury is a devastating complication of aortic repair. Despite developments for the prevention and treatment of spinal cord injury, its incidence is still considerably high and therefore, influences patient outcome. Microcirculation plays a key role in tissue perfusion and oxygen supply and is often dissociated from macrohemodynamics. Thus, direct evaluation of spinal cord microcirculation is essential for the development of microcirculation-targeted therapies and the evaluation of existing approaches in regard to spinal cord microcirculation. However, most of the methods do not provide real-time assessment of spinal cord microcirculation. The aim of this study is to describe a standardized protocol for real-time spinal cord microcirculatory evaluation using laser-Doppler needle probes directly inserted in the spinal cord. We used a porcine model of ischemia/reperfusion to induce deterioration of the spinal cord microcirculation. In addition, a fluorescent microsphere injection technique was used. Initially, animals were anesthetized and mechanically ventilated. Thereafter, laser-Doppler needle probe insertion was performed, followed by the placement of cerebrospinal fluid drainage. A median sternotomy was performed for exposure of the descending aorta to perform aortic cross-clamping. Ischemia/reperfusion was induced by supra-celiac aortic cross-clamping for a total of 48 min, followed by reperfusion and hemodynamic stabilization. Laser-Doppler Flux was performed in parallel with macrohemodynamic evaluation. In addition, automated cerebrospinal fluid drainage was used to maintain a stable cerebrospinal pressure. After completion of the protocol, animals were sacrificed, and the spinal cord was harvested for histopathological and microsphere analysis. The protocol reveals the feasibility of spinal cord microperfusion measurements using laser-Doppler probes and shows a marked decrease during ischemia as well as recovery after reperfusion. Results showed comparable behavior to fluorescent microsphere evaluation. In conclusion, this new protocol might provide a useful large animal model for future studies using real-time spinal cord microperfusion assessment in ischemia/reperfusion conditions.
Zielsetzung Operationen in der gynäkologischen Onkologie sind mit erheblichen Morbiditätsraten assoziiert. Zur Verbesserung der postoperativen Erholung wurden interdisziplinäre Behandlungsstrategien, sog. “Enhanced Recovery after Surgery“ Programme entwickelt. Diese beinhalten neben einer frühen Mobilisation und einem zügigen Kostaufbau eine zielgerichtete Infusionstherapie sowie ein multimodales Schmerzkonzept.