Capillary electrochromatography (CEC) monolithic columns were prepared following a two-step synthetic pathway based on (i) UV-induced in situ radical polymerization of N-acryloxysuccinimide (NAS) and ethylene dimethacrylate (EDMA) and (ii) in situ functionalization of the NAS-containing monolithic matrix with various alkylamines. The first synthetic step was performed using toluene as a porogenic solvent. The successful grafting of the alkylamines onto the reactive matrix was confirmed on the basis of qualitative analysis of Raman spectra recorded before and after the chemical modification step. All the electrochromatographic results indicate a strong dependence of the retention, efficiency and selectivity of the monolithic columns on small variations of mobile phase composition and nature of the grafted aliphatic selector in agreement with the typical reversed-phase behaviour. Van Deemter plots for a series of alkylbenzene homologues injected on a column bearing hexyl-segments as side chains are also presented.
High-performance liquid chromatography (HPLC) was used to examine the retention behavior of monomethoxypoly(ethylene glycol)s bearing one hydrophobic naphthyl end group (Nap-MPEG) on beta-cyclodextrin polymer (poly-beta-CD) immobilized on a silica support, under isocratic elution conditions and using water as mobile phase. Studies of retentions and theoretical plate heights H were conducted at infinite dilution by comparing the behavior of Nap-MPEGs having different molecular weight (750, 1000 and 5000 g/mol). The larger is its molecular size, the lower is the retention of the polymer. The linear increase of H with mobile phase velocity reveals slow mass-transfer kinetics arising from the restricted diffusion into the pores of the support. The complexation constants between the Nap-MPEGs and beta-CD in solution (around 500M(-1)) were determined from the decrease of retention observed by adding increasing concentrations of hydroxypropyl beta-CD into the eluent. The peak profiles in mass-overload conditions were studied by fitting a model based upon bi-Langmuir kinetics which assumes a non-uniform support having two types of binding sites and apparent adsorption rate constants are used to describe mass-transfer kinetics. A three-parameter adsorption equilibrium isotherm was sufficient to account for the modifications of peak shapes observed when increasing amounts of polymer were injected. This result indicates an interaction with a heterogeneous poly-beta-CD support mainly composed of low affinity groups, non-saturable in the range of polymer concentration studied. An upper limit was estimated for the equilibrium constant (<1000 M(-1)) characterizing the affinity of Nap-MPEG for the non-saturable sites of the poly-beta-CD support. Large affinity constants (8-9 x 10(4)M(-1)) were found for the interaction of Nap-MPEGs with a small percentage of active sites.
An electrochemical DNA biosensor was developed by DNA immobilization at the electrode surface and its electrochemical behavior was studied in relation with different materials added in the paste. The aim was to study new materials for the development of new electrode surfaces, to be applied in the study of DNA – drug interactions. New electrochemical sensing materials using polymer multilayers were reported for the adsorption of DNA. These materials were prepared by mixing a polymer ion exchanger and graphite powder. The mixture was then used to render the modified carbon paste electrode (CPE), on the surface of which the dsDNA was adsorbed and studied by differential pulse voltammetry (DP voltammetry). The signal of guanine oxidation peak of DNA was followed. This modified biosensor was applied for the study of the interaction between DNA and the known intercalators Ethidium Bromide (EB) and Acridine Orange (AO). The established biosensor exhibited an improvement of its sensitivity and repeatability compared with the conventional CPE DNA biosensor.
High-performance frontal affinity chromatography was employed to study the adsorption-desorption kinetics characterizing the retention of beta-lactoglobulin (beta-LG) onto polyclonal anti-beta-lactoglobulin (anti-beta-LG) chromatographic supports. The adsorption and desorption processes were studied by analyzing two different elution fronts separated by a relatively long rinsing step. The method consists in performing two successive frontal injections of the protein. In between, the column was rinsed with a given volume of mobile phase (buffer alone). During this rinsing stage, a partial desorption may occur and a novel amount of protein could be adsorbed in the second frontal injection step. The whole process (first adsorption, possible desorption, and second adsorption) was simulated by a numerical procedure, in which the column was divided into a large number of slices. A model based on bi-Langmuir type kinetics was used to describe the adsorption of the protein on the support. The model assumes a non-uniform adsorbent with two types of binding sites. At equilibrium the adsorption isotherm is of the bi-Langmuir type. A global adsorption effect was considered which includes the effective binding process and the mass transfer resistances due to the transport to the binding site. Therefore, the column capacity and the kinetic parameters of the model (apparent adsorption and desorption rate constants) were determined from the best fit of the first and second adsorption fronts to the experimental ones. The other parameters of the model are the saturation capacities for the adsorption on each type of sites. The equilibrium affinity constants were estimated in a single experiment from the ratio of the apparent adsorption and desorption rate constants. The high values found (around 10(8) M(-1)) reveal a strong interaction of beta-LG with the immunoadsorbent. Kinetic measurements were carried out at different flow rates. Both the apparent adsorption and desorption kinetics were faster at larger flow rates, indicating an important contribution of the mass transfer resistance in the stagnant fluid at the particle boundary. However, as expected, close values were found for the resulting equilibrium constants calculated from the ratio of the apparent adsorption and desorption rate constant determined at various flow rates.
The Huygens probe landed on Titan on 14 January this year, and seven papers published in this issue record the encounter. They describe a world that resembles a primitive Earth, complete with weather systems and geological activity. The 'Huygens on Titan' section opens with an overview of the descent and landing and a News and Views piece. Tomasko et al. describe the dry riverbed and drainage channels seen during Huygens' descent, evidence that liquid methane falls as rain or erupts from cryovolcanoes, periodically flooding the surface. This paper includes the images used on the cover to the Huygens section. Niemann et al. measured the abundances of isotopes of argon, nitrogen and carbon in the atmosphere, and conclude that there is no evidence that Titan's methane comes from biological activity. Fulchignoni et al. obtained precise measurements of temperature and pressure from the upper atmosphere right down to the surface. On the way down Huygens recorded evidence for lightning. Zarnecki et al. report that the probe landed on a relatively smooth surface of icy grains with the consistency of wet clay or sand. Isräl et al. report that the aerosols in Titan's clouds have solid cores made from complex organic molecules containing carbon and nitrogen. And Bird et al. found that on average Titan's winds blow in the same direction as the moon rotates, and that close to the surface these winds are very weak, travelling at around walking speed. Aerosols in Titan's atmosphere play an important role in determining its thermal structure1,2,3. They also serve as sinks for organic vapours4 and can act as condensation nuclei for the formation of clouds5,6, where the condensation efficiency will depend on the chemical composition of the aerosols5,7. So far, however, no direct information has been available on the chemical composition of these particles. Here we report an in situ chemical analysis of Titan's aerosols by pyrolysis at 600 °C. Ammonia (NH3) and hydrogen cyanide (HCN) have been identified as the main pyrolysis products. This clearly shows that the aerosol particles include a solid organic refractory core. NH3 and HCN are gaseous chemical fingerprints of the complex organics that constitute this core, and their presence demonstrates that carbon and nitrogen are in the aerosols.
Adamantane-modified compounds are known to form stable complexes with beta-cyclodextrins (beta-CD) by host-guest interactions. In this study, the inclusion complex formed between beta-CD cavities and the adamantane group was evaluated for the elaboration of a cation-exchange support. The synthesis of the chromatographic supports involved three steps: (i) a polymer of beta-CD was grafted to diol-modified silica, (ii) a dextran polymer was modified by both adamantane groups and ionizable COOH functions, (iii) the dextran derivative (Ad-Dex-COOH) was bound to the chromatographic support by complexation between the adamantane groups of the dextran and beta-CD cavities of the support. The polymer immobilization on the beta-CD support was successful as the resulting support exhibited weak cation-exchange properties. The stationary phase was easy to prepare under mild conditions (aqueous media, room temperature) and was quite stable when using aqueous mobile phases. The chromatographic behaviour of model proteins was studied in isocratic elution by examining the effect of salt concentration in the buffer on retention. A mixed retention mode was found for lysozyme, revealing both electrostatic and hydrophobic interactions with the stationary phase.
Two Wall Coated Open Tubular capillary columns, coated with poly(cyanopropylphenyl-dimethyl)siloxane and poly(diphenyl-dimethyl)siloxane stationary phases, have been selected for use in the COmetary SAmpling and Composition space experiment for the separation and identification of the wide range of volatile organic compounds which could be present in cometary nuclei. This article presents the main characteristics of the tandem column system for the analysis of solutes of cometary interest within the constraints of space instrumental operating conditions. The high efficiency of the columns is demonstrated and the influence of the operating conditions on their separation properties are investigated. The studied columns exhibit complementary retention pattern: their use in a dual column system makes it possible to achieve the separation and the identification of the compounds of interest. Finally, the good analytical behavior of the columns when analyzing samples which include large amounts of water, the main presumed volatile in comets, is demonstrated. The presented results thus show the suitability of the selected tandem columns system for the desired analyses, and their performance on adaptation to in-situ cometary chemical investigation.
The binding of an anticancer drug (actinomycin D or ACTD) to double-stranded DNA (dsDNA) was studied by means of high-performance liquid chromatography (HPLC). ACTD is an antitumor antibiotic containing one chromophore group and two pentapeptidic lactone cycles that binds dsDNA. Incubations of ACTD with DNA were performed at physiological pH. The complexed and free ligand concentrations of the mixture were quantified at 440 nm from their separation on a size-exclusion chromatographic (SEC) column using the same buffer for the elution and the sample incubation. The DNA and the ACTD-DNA complexes were eluted at the column exclusion volume while the ligand was retained on the support. An apparent binding curve was obtained by plotting the amount emerging at the exclusion column volume against that eluted at free ACTD retention volume. A dissociating effect was evidenced and the binding parameters were significantly different from those obtained at equilibrium by visible absorbance titration. The equilibrium binding parameters determined by absorption spectroscopy were used as starting data in the numerical simulations of the chromatographic process. The results showed a strong dependency of the apparent binding parameters on the reaction kinetics. Finally the comparison of the apparent binding curve obtained from the HPLC experiments and from the numerical simulations permitted an evaluation of the dissociation rate constant (kd = 0.004 s(-1)).
A solid–liquid extraction method able to perform in situ extraction of organic compounds on Mars is proposed. The extraction efficiency of various organic solvents was tested and compared to that of water. The selected key compounds are molecules of exobiological interest: glycine, alanine, serine, glutamic acid, oxalic acid, benzoic acid, phthalic acid, isophthalic acid, terephthalic acid and 1,3,5-benzenetricarboxylic acid. Among the organic solvents, propanol gives the highest yield of extraction for all the targeted compounds except for benzoic acid. A mixture of propanol and ethyl acetate increases significantly the extraction yield of benzoic acid. The extraction time was considerably reduced (140 h to 15 min) by using sonication. The method is discussed for an easy automation with coupling to an in situ GC–MS space instrument.
In gas chromatographic isothermal separations of multicomponent mixtures, i.e., mixtures where the number of components is high and unknown, the efficiency is low and not enough to allow a complete separation with a consequent severe peak overlapping in the chromatogram. The consequence is a significant loss in analytical information content. Therefore it is practically mandatory to use a chemometric procedure to decode the complex chromatogram, i.e. to deconvolve the overlapping signal to extract from it information on the mixture and the separation system. Isothermal separations are not very popular, due to their low efficiency, but they are very common in in situ analyses during space missions, as a consequence of flight constraints on instrumentation complexity and power (energy saving). In this work a chemometric approach based on Fourier analysis is applied to chromatograms obtained under isothermal or low temperature programming conditions. These conditions simulate those employed in space missions. The procedure has been applied to standard mixtures containing compounds representative of the planetary atmospheres that will be investigated in the near future: in particular, those related to Titan's atmosphere (Cassini-Huygens mission) and a cometary nucleus (Rosetta mission), i.e., hydrocarbons and oxygenated compounds with carbon atom numbers ranging from 2 to 8. The original approach, developed for constant peak width, is extended to variable peak width, in particular to the case of peak width linearly increasing with retention time, representing isothermal separations. The proposed approach is able to characterise complex isothermal chromatograms in terms of number of components present in the mixture and of separation efficiency: such results are useful in interpreting data recovered from space missions and for optimising analysis conditions compatible with flight constraints.
High performance liquid chromatography (HPLC) was used to study the mechanism of formation of polyelectrolyte multilayers on porous silicas. The coatings were produced by alternating the adsorption of positively and negatively charged polymers. The stationary phases formed by adsorbing a single layer, double layers and triple layers were tested by studying the elution behavior of model proteins. The double polymer coating was achieved by adsorbing first a polycation such as hexadimethrine bromide (HB) on the HPLC silica support and then a polyanion such as dextran sulfate (DS) on the cationic layer formed. The retention properties of this support are mainly those of a cation exchanger as the negatively charged proteins were strongly retained while positively charged ones were weakly adsorbed. This work demonstrated the importance of the first underlying layer as the retention behavior of proteins was greatly affected by the properties of this coating. The triple polymer coating was achieved by adsorbing the polycation (HB) on the double layer coating (HB-DS). Its retention behavior was that of an anion exchange support. The HB-DS stationary phase displayed good chromatographic performances, with an adsorbed layer relatively stable. The polyelectrolyte multilayer coating procedure was useful to easily synthesize cation-exchange supports for the separation of basic proteins.
Beta-Lactoglobulin is one of the main components of whey proteins. Among other reasons, its allergenicity makes its determination in hypoallergenic foods and bio-pharmaceutical products necessary. Immunoaffinity chromatography is a widely accepted technique for purification and analysis of proteins. Knowledge of the apparent kinetics of the adsorption of beta-lactoglobulin onto the anti-beta-lactoglobulin immunochromatographic column is important to optimize the analytical process. High-performance frontal affinity chromatography was used to study the apparent kinetics of the adsorption process. Langmuir and bi-Langmuir kinetic models, assuming one and two kinds of binding sites, respectively, were used to characterize the adsorption kinetics of beta-lactoglobulin B on a polyclonal immunoadsorbent. Very good fits were obtained with the bi-Langmuir model for two different concentrations of beta-lactoglobulin and this allowed us to calculate the apparent adsorption rate constants and the column capacities for both kinds of sites. Experimental results indicate the possibility that the adsorption process is not irreversible. The values of the apparent dissociation rate constants leading to the best fit were estimated and the affinity constants were calculated.
The Monte Carlo model of chromatography is a description of the chromatographic process from a molecular (microscopic) point of view and it is intrinsically based on the stochastic theory of chromatography originally proposed by Giddings and Eyring. The program was previously validated at infinite dilution (i.e., in linear conditions) by some of the authors of the present paper. In this work, it has been further validated under nonlinear conditions. The correspondence between the Monte Carlo model and the well-known Thomas kinetic model (macroscopic model), for which closed-form solutions are available, is demonstrated by comparing Monte Carlo simulations, performed at different loading factors, with the numerical solutions of the Thomas model calculated under the same conditions. In all the cases investigated, the agreement between Monte Carlo simulations and Thomas model results is very satisfactory. Additionally, the exact correspondence between the Thomas kinetic model and Giddings model, when near-infinite dilution conditions are approached, has been demonstrated by calculating the limit of the Thomas model when the loading factor goes to zero. The model was also validated under limit conditions, corresponding to cases of very slow adsorption-desorption kinetics or very short columns. Different hypotheses about the statistical distributions of the random variables "residence time spent by the molecule in mobile and stationary phase" are investigated with the aim to explain their effect on the peak shape and on the efficiency of the separation.
To study Titan, the largest moon of Saturn, laboratory simulation experiments have been performed to obtain analogues of Titan’s aerosols (named tholins) using different energy sources. Tholins, which have been demonstrated to represent aerosols in Titan’s haze layers, are a complex mixture, resulting from the chemical evolution of several hydrocarbons and nitriles. Their chromatographic analysis yields complex chromatograms, which require the use of mathematical procedures to extract from them all the information they contain. Two different chemometric approaches (the Fourier analysis approach and the statistical model of peak overlapping) have been successfully applied to pyrolysis–GC–MS chromatogram of a tholin sample. Fundamental information on the mixture’s chemical composition (number of components, m) and on the separation system performance (separation efficiency, σ) can be easily estimated: the excellent correspondence between the data calculated by the two independent procedures proves the reliability of the statistical approaches in characterizing a tholin chromatogram. Moreover, the plot of autocorrelation function contains, in a simplified form, all the information on the retention pattern: retention recursivities can be easily singled out and related to specific molecular structure variations. Therefore, the autocorrelation function (ACF) plot constitutes a simplified fingerprint of the pyrolysis products of tholins, which can be used as a powerful tool to characterize a tholin sample.