Direct observation of proton emission for very small Q values is often unfeasible due to the long partial half-lives of the proton emission channel associated with tunneling through the Coulomb barrier. Therefore, proton emitters with very small decay energies may require the masses of both parent and daughter nuclei in order to establish them as proton unbound. Nuclear mass models have been used to predict the proton dripline of the thulium (Tm) isotopic chain (Z = 69), but until now the proton separation energy has not been experimentally tested. Mass measurements were performed using a multiple reflection time-of-flight mass spectrometer (MR-TOF-MS) at TRIUMF's TITAN facility to conclusively map the limit of proton-bound Tm. The masses of neutron-deficient 149Tm and 150Tm, combined with measurements of 149m,gEr (which were found to deviate from literature by approximate to 150 keV), provide the first experimental confirmation that 149Tm is the first proton-unbound nuclide in the Tm chain. Our measurements also enable determination of the strength of the N = 82 neutron shell gap at the Tm proton drip line, providing evidence supporting its continued existence.
We demonstrate efficient subthermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures T + = E+/k(B) below 200 mK in preparation times shorter than 500 s. This corresponds to the fastest resistive single-particle cyclotron cooling to subthermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error rate < 0.000023, more than 3 orders of magnitude better than in previous best experiments. This method has enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter and antimatter symmetry, high- precision mass spectrometry, and measurements of electron g factors bound to highly charged ions that test quantum electrodynamics and establish standards for magnetometry.
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.
The BASE collaboration at the antiproton decelerator/ELENA facility of CERN compares the fundamental properties of protons and antiprotons with ultra-high precision. Using advanced Penning trap systems, we have measured the proton and antiproton magnetic moments with fractional uncertainties of 300 parts in a trillion (p.p.t.) and 1.5 parts in a billion (p.p.b.), respectively. The combined measurements improve the resolution of the previous best test in that sector by more than a factor of 3000. Very recently, we have compared the antiproton/proton charge-to-mass ratios with a fractional precision of 16 p.p.t., which improved the previous best measurement by a factor of 4.3. These results allowed us also to perform a differential matter/antimatter clock comparison test to limits better than 3
New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24−26Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N=14 mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N=20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.
Currently, the world's only source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of fundamental interactions and their symmetries. However, magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of charge, parity, and time-reversal invariance with antiprotons and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.
We present a fluorescence-detection system for laser-cooled Be-9(+) ions based on silicon photomultipliers (SiPMs) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1 s(-1) and a detection efficiency of 2.5(3)%. We further discuss the design of our cryogenic fluorescence-detection trap and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our sympathetic laser-cooling experiment.
We present the design and characterization of a cryogenic window based on an ultra-thin aluminized biaxially oriented polyethylene terephthalate foil at T < 10 K, which can withstand a pressure difference larger than 1 bar at a leak rate <1×10-9 mbar l/s. Its thickness of ∼1.7 μm makes it transparent to various types of particles over a broad energy range. To optimize the transfer of 100 keV antiprotons through the window, we tested the degrading properties of different aluminum coated polymer foils of thicknesses between 900 and 2160 nm, concluding that 1760 nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of seven holes with a diameter of 1 mm and will transmit up to 2.5% of the injected 100 keV antiproton beam delivered by the Antiproton Decelerator and Extra Low ENergy Antiproton ring facility of CERN.
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.
The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, $-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}}$ = $1.000\,000\,000\,003 (16)$, is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of $1.96\cdot10^{-27}\,$GeV (C$.$L$.$ 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP$_\text{cc}$) for antimatter to a level of $|\alpha_{g}-1| < 1.8 \cdot 10^{-7}$, and enables the first differential test of the WEP$_\text{cc}$ using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEP$_\text{cc}$-violating coefficient to $|\alpha_{g,D}-1|<0.030$.
The standard model of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe 1 , which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision 2 – 5 . Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning trap systems 6 . For instance, we previously compared the proton/antiproton magnetic moments with 1.5 parts per billion fractional precision 7 , 8 , which improved upon previous best measurements 9 by a factor of greater than 3,000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts per trillion. Our result is based on the combination of four independent long-term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental set-ups incorporating different systematic effects. The final result, -(q/m)_p/(q/m)_p̅=1.000000000003(16) , is consistent with the fundamental charge–parity–time reversal invariance, and improves the precision of our previous best measurement 6 by a factor of 4.3. The measurement tests the standard model at an energy scale of 1.96 × 10 −27 gigaelectronvolts (confidence level 0.68), and improves ten coefficients of the standard model extension 10 . Our cyclotron clock study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP cc ) for antimatter to less than 1.8 × 10 −7 , and enables the first differential test of the WEP cc using antiprotons 11 . From this interpretation we constrain the differential WEP cc -violating coefficient to less than 0.030.
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and find, based on analytical calculations and numerical simulations, that two of them are capable of achieving proton temperatures of about 10 mK with cooling times on the order of 10 s. In contrast, established methods such as feedback-enhanced resistive cooling with image-current detectors are limited to about 1 K in 100 s. Since the studied techniques are applicable to any trapped charged particle and allow spatial separation between the target ion and the cooling species, they enable a variety of precision measurements based on trapped charged particles to be performed at improved sampling rates and with reduced systematic uncertainties.
This report summarizes the progress made by the BASE collaboration in 2021. It contains short summaries of the main output produced, which are three manuscripts published, one in Physical Review Letters [1] and two in Nature [2, 3]. One of these manuscripts sets constraints on the coupling of axions and axion-like particles to photons using the highly sensitive single particle detection systems in the strong magnetic field of the superconducting magnet of the experiment [4, 5]. As a consequence of the successful demonstration of this LC-resonator-based haloscope technique we started constructing the new experiment BASE-CDM. The second manuscript reports on the first demonstration of sympathetic cooling of a single trapped proton by coupling the particle to a cloud of laser-cooled 9Be+ ions using a common-endcap Penning trap method and a superconducting tuned circuit that mediates the cooling [2]. This work was selected by "Physics World" as one of the top ten physics breakthroughs made in 2021. The third manuscript reports on a 16parts-per-trillion comparison of the proton-to-antiproton charge-to-mass ratio. This measurement improves the previous best limit [6] by a factor of 4.3, and contains the first-ever performed clock-based differential test of the weak equivalence principle with protons and antiprotons. In addition, the group focused on the development and implementation of the new ELENA/BASE interface, and the setup of an experiment dedicated to measure the antiproton magnetic moment with a fractional precision at a level of ≈ 100 parts in a trillion. This includes the setup of a new trap stack, the development of revised cryogenic experiment electronics and superconducting single particle detectors, as well as the implementation of a new magnet shimming system and the development of a cooling trap for sub-thermal cooling cycles at drastically reduced thermalization times.
We describe a newly developed polytetrafluoroethylene/copper capacitor driven by a cryogenic piezoelectric slip-stick stage and demonstrate with the chosen layout cryogenic capacitance tuning of ≈60 pF at ≈10 pF background capacitance. Connected to a highly sensitive superconducting toroidal LC circuit, we demonstrate tuning of the resonant frequency between 345 and 685 kHz, at quality factors Q > 100 000. Connected to a cryogenic ultra low noise amplifier, a frequency tuning range between 520 and 710 kHz is reached, while quality factors Q > 86 000 are achieved. This new device can be used as a versatile image current detector in high-precision Penning-trap experiments or as an LC-circuit-based haloscope detector to search for the conversion of axion-like dark matter to radio-frequency photons. This new development increases the sensitive detection bandwidth of our axion haloscope by a factor of ≈1000.
The performance of high-precision mass spectrometry of radioactive isotopes can often be hindered by large amounts of contamination, including molecular species, stemming from the production of the radioactive beam. In this paper, we report on the development of Collision-Induced Dissociation (CID) as a means of background reduction for experiments at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This study was conducted to characterize the quality and purity of radioactive ion beams and the reduction of molecular contaminants to allow for mass measurements of radioactive isotopes to be done further from nuclear stability. This is the first demonstration of CID at an ISOL-type radioactive ion beam facility, and it is shown that molecular contamination can be reduced up to an order of magnitude.
We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs with masses around 2.7906-2.7914 neV/c^{2} to g_{aγ}<1×10^{-11} GeV^{-1}. This is more than one order of magnitude lower than the best laboratory haloscope and approximately 5 times lower than the CERN axion solar telescope (CAST), setting limits in a mass and coupling range which is not constrained by astrophysical observations. Our approach can be extended to many other Penning-trap experiments and has the potential to provide broad limits in the low ALP mass range.
High-accuracy mass measurements of neutron-deficient Yb isotopes have been performed at TRIUMF using TITAN's multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS). For the first time, an MR-TOF-MS was used on line simultaneously as an isobar separator and as a mass spectrometer, extending the measurements to two isotopes further away from stability than otherwise possible. The ground state masses of ^{150,153}Yb and the excitation energy of ^{151}Yb^{m} were measured for the first time. As a result, the persistence of the N=82 shell with almost unmodified shell gap energies is established up to the proton drip line. Furthermore, the puzzling systematics of the h_{11/2}-excited isomeric states of the N=81 isotones are unraveled using state-of-the-art mean field calculations.
Abstract Efficient cooling of trapped charged particles is essential in many fundamental physics experiments, for high-precision metrology, and for quantum technology. Until now, ion-ion coupling for sympathetic cooling or quantum state control has been limited to ion species with accessible optical transitions or has required close-range Coulomb interactions. To overcome this limitation and further develop scalable quantum control techniques, there has been a sustained desire to extend laser-cooling techniques to particles in macroscopically separated traps, opening quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions, and antimatter particles. Here, we demonstrate sympathetic cooling of a single proton by laser cooled Be+ ions stored in a spatially separated Penning trap. The two traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We simultaneously demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environment temperature. Importantly, as this technique does not rely on the direct Coulomb interaction but rather on image-current interactions, it can be easily applied to an experiment with antiprotons, facilitating improved precision in matter-antimatter comparisons and dark matter searches.
Efficient cooling of trapped charged particles is essential to many fundamental physics experiments 1,2 , to high-precision metrology 3,4 and to quantum technology 5,6 . Until now, sympathetic cooling has required close-range Coulomb interactions 7,8 , but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps 5,9,10 , extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be + ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image–current interactions, it can be easily applied to an experiment with antiprotons 1 , facilitating improved precision in matter–antimatter comparisons 11 and dark matter searches 12,13 .
TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN) has specialized in fast Penning Trap mass spectrometry of very short-lived radioactive isotopes. The facility has been upgraded with a Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS) to continue its quest towards more exotic nuclides, which are critical for our understanding of nuclear structure effects far from the valley of beta stability and for the nucleosynthesis of heavy elements in explosive astrophysical environments. In this publication, we discuss the implementation, operation and performance of TITAN’s MR-TOF-MS as a stand-alone high-precision mass spectrometer and as an isobar separator. By using the novel mass-selective re-trapping technique for the isobar separation, the MR-TOF-MS can consecutively perform separation and mass measurement of the same ion population, acting as its own isobar separator. The device boosts the dynamic range and reach of the TITAN facility by several orders of magnitude. The MR-TOF-MS reaches a high mass resolving power (m/Δm∼400000), high precision and mass accuracy (δm/m<10−7), is fast (common cycle time 20ms), shows high sensitivity and very large dynamic range (ion of interest to contaminant ratios of up to 1 to 106).