PURPOSE To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. METHODS The system tracks individual protons through one (X, Y) scintillating fiber tracker plane upstream and downstream of the object and into a 13 cm-thick scintillating block residual energy detector. The fibers in the tracker planes are multiplexed into silicon photomultipliers (SiPMs) to reduce the number of electronics channels. The light signal from the residual energy detector is collected by 16 photomultiplier tubes (PMTs). Only four signals from the PMTs are output from each event, which allows for fast signal readout. A robust calibration method of the PMT signal to residual energy has been developed to obtain accurate proton images. The development of patient-specific scan patterns using multiple input energies allows for an image to be produced with minimal excess dose delivered to the patient. RESULTS The calibration of signals in the energy detector produces accurate residual range measurements limited by intrinsic range straggling. We measured the water-equivalent thickness (WET) of a block of solid water (physical thickness of 6.10 mm) with a proton radiograph. The mean WET from all pixels in the block was 6.13 cm (SD 0.02 cm). The use of patient-specific scan patterns using multiple input energies enables imaging with a compact range detector. CONCLUSIONS We have developed a prototype clinical proton radiography system for pretreatment imaging in proton radiation therapy. We have optimized the system for use with pencil beam scanning systems and have achieved a reduction of size and complexity compared to previous designs.
PURPOSE:Verification of patient-specific proton stopping powers obtained in the patient's treatment position can be used to reduce the distal and proximal margins needed in particle beam planning. Proton radiography can be used as a pretreatment instrument to verify integrated stopping power consistency with the treatment planning CT. Although a proton radiograph is a pixel by pixel representation of integrated stopping powers, the image may also be of high enough quality and contrast to be used for patient alignment. This investigation quantifies the accuracy and image quality of a prototype proton radiography system on a clinical proton delivery system.METHODS:We have developed a clinical prototype proton radiography system designed for integration into efficient clinical workflows. We tested the images obtained by this system for water-equivalent thickness (WET) accuracy, image noise, and spatial resolution. We evaluated the WET accuracy by comparing the average WET and rms error in several regions of interest (ROI) on a proton radiograph of a custom peg phantom. We measured the spatial resolution on a CATPHAN Line Pair phantom and a custom edge phantom by measuring the 10% value of the modulation transfer function (MTF). In addition, we tested the ability to detect proton range errors due to anatomical changes in a patient with a customized CIRS pediatric head phantom and inserts of varying WET placed in the posterior fossae of the brain. We took proton radiographs of the phantom with each insert in place and created difference maps between the resulting images. Integrated proton range was measured from an ROI in the difference maps.RESULTS:We measured the WET accuracy of the proton radiographic images to be ±0.2 mm (0.33%) from known values. The spatial resolution of the images was 0.6 lp/mm on the line pair phantom and 1.13 lp/mm on the edge phantom. We were able to detect anatomical changes producing changes in WET as low as 0.6 mm.CONCLUSION:The proton radiography system produces images with image quality sufficient for pretreatment range consistency verification.
PURPOSE:Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield units of patient tissues into proton relative stopping power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stopping power. We aim to demonstrate proton CT imaging with complex porcine samples, to analyze in detail three-dimensional regions of interest, and to compare proton stopping powers directly measured by proton CT to those determined from x-ray CT scans.METHODS:We have used a prototype proton imaging system with single proton tracking to acquire proton radiography and proton CT images of a sample of porcine pectoral girdle and ribs, and a pig's head. We also acquired close in time x-ray CT scans of the same samples and compared proton stopping power measurements from the two modalities. In the case of the pig's head, we obtained x-ray CT scans from two different scanners and compared results from high-dose and low-dose settings.RESULTS:Comparing our reconstructed proton CT images with images derived from x-ray CT scans, we find agreement within 1% to 2% for soft tissues and discrepancies of up to 6% for compact bone. We also observed large discrepancies, up to 40%, for cavitated regions with mixed content of air, soft tissue, and bone, such as sinus cavities or tympanic bullae.CONCLUSIONS:Our images and findings from a clinically realistic proton CT scanner demonstrate the potential for proton CT to be used for low-dose treatment planning with reduced margins.
Proton CT (pCT) is a promising new imaging technique that can reconstruct relative stopping power (RSP) more accurately than x-ray CT in each cubic millimeter voxel of the patient. This, in turn, will result in better proton range accuracy and, therefore, smaller planned tumor volumes (PTV). The hardware description and some reconstructed images have previously been reported. In a series of two contributions, we focus on presenting the software algorithms that convert pCT detector data to the final reconstructed pCT images for application in proton treatment planning. There were several options on how to accomplish this, and we will describe our solutions at each stage of the data processing chain. In the first paper of this series, we present the data acquisition with the pCT tracking and energy-range detectors and how the data are preprocessed, including the conversion to the well-formatted track information from tracking data and water-equivalent path length from the data of a calibrated multi-stage energy-range detector. These preprocessed data are then used for the initial image formation with an FDK cone-beam CT algorithm. The output of data acquisition, preprocessing, and FDK reconstruction is presented along with illustrative imaging results for two phantoms, including a pediatric head phantom. The second paper in this series will demonstrate the use of iterative solvers in conjunction with the superiorization methodology to further improve the images resulting from the upfront FDK image reconstruction and the implementation of these algorithms on a hybrid CPU/GPU computer cluster.
AbstractPurposeProton CT (pCT) has the ability to reduce inherent uncertainties in proton treatment by directly measuring the relative proton stopping power with respect to water, thereby avoiding the uncertain conversion of X‐ray CT Hounsfield unit to relative stopping power and the deleterious effect of X‐ ray CT artifacts. The purpose of this work was to further evaluate the potential of pCT for pretreatment positioning using experimental pCT data of a head phantom.MethodsThe performance of a 3D image registration algorithm was tested with pCT reconstructions of a pediatric head phantom. A planning pCT simulation scan of the phantom was obtained with 200 MeV protons and reconstructed with a 3D filtered back projection (FBP) algorithm followed by iterative reconstruction and a representative pretreatment pCT scan was reconstructed with FBP only to save reconstruction time. The pretreatment pCT scan was rigidly transformed by prescribing random errors with six degrees of freedom or deformed by the deformation field derived from a head and neck cancer patient to the pretreatment pCT reconstruction, respectively. After applying the rigid or deformable image registration algorithm to retrieve the original pCT image before transformation, the accuracy of the registration was assessed. To simulate very low‐dose imaging for patient setup, the proton CT images were reconstructed with 100%, 50%, 25%, and 12.5% of the total number of histories of the original planning pCT simulation scan, respectively.ResultsThe residual errors in image registration were lower than 1 mm and 1° of magnitude regardless of the anatomic directions and imaging dose. The mean residual errors ranges found for rigid image registration were from −0.29 ± 0.09 to 0.51 ± 0.50 mm for translations and from −0.05 ± 0.13 to 0.08 ± 0.08 degrees for rotations. The percentages of sub‐millimetric errors found, for deformable image registration, were between 63.5% and 100%.ConclusionThis experimental head phantom study demonstrated the potential of low‐dose pCT imaging for 3D image registration. Further work is needed to confirm the value pCT for pretreatment image‐guided proton therapy.
One of the major challenges to proton beam therapy at this time is the uncertainty of the true range of a clinical treatment proton beam as it traverses the various tissues and organs in a human body. This uncertainty necessitates the addition of greater “margins” to the planning target volume along the direction of the beam to ensure safety and tumor target coverage. Proton radiography holds promise as both an image-guidance method for proton beam therapy and as a means of estimating particle beam range in the clinic. In this brief report, we present some of the first real and reconstructed proton radiographs using our particular system. Our qualitative review of these images indicates that this method has excellent potential as a proton radiography–based image-guidance system. Based on the encouraging results of our preliminary work, more rigorous and quantitative analyses will be performed shortly and we shall continue to explore the potential of this approach for addressing the particle beam range uncertainty issue.
ObjectiveProton beam therapy is an emerging modality for cancer treatment that, compared to X-ray radiation therapy, promises to provide better dose delivery to clinical targets with lower doses to normal tissues. Crucial to accurate treatment planning and dose delivery is knowledge of the water equivalent path length (WEPL) of each ray, or pencil beam, from the skin to every point in the target. For protons, this length is estimated from relative stopping power based on X-ray Hounsfield units. Unfortunately, such estimates lead to 3 to 4% uncertainties in the proton range prediction. Therefore, protons in the Bragg peak may overshoot (or undershoot) the desired stopping depth in the target causing tissue damage beyond the target volume. Recent studies indicate that tomographic imaging using protons has the potential to provide directly more accurate measurement of RSPs with significantly lower radiation dose than X-rays. We are currently working on a proton radiography system that promises to provide accurate two-dimensional (2D) images of WEPL values for protons that pass through the body. These will be suitable for positioning and range verification in daily treatments. In this study, we demonstrate that this system is capable of rapidly achieving such accurate images in clinically meaningful times.MethodsWe have developed a software platform to characterize the potential performance of the prototype proton radiography system. We use Geant4 to simulate raw data detected by the device. An especially written software - pRad - was written to process these data as they are received and uses iterative methods to generate radiographs. The software has been designed to generate a radiograph from a few million protons in under a minute after receiving the first proton from the device. We used a head phantom with known chemical compositions that could be modeled quite accurately in Geant4 simulations of proton radiographs. The radiographs are displayed as pixelated WEPL values displayed on a 2D gray scale image of WEPL values.ResultsRapid radiograph reconstruction of 3D phantoms using simulated proton pencil beams have been achieved with our software platform. On a modest desktop computer with a single central processing unit (CPU) and a single graphics processing unit (GPU), it takes about 11s to reconstruct images using iterative linear algorithms to reconstruct a radiograph from 7.6 million protons. For the radiographic reconstructions of the head phantom described here, the mean WEPL errors, in the proton radiograph using a large majority of the pixels in the complete image were less than 1mm when compared to images obtained without proton scattering and without detector resolution included.ConclusionWe have demonstrated, through computer simulations of proton irradiation of a pediatric head phantom using the newly built pRad detector and image reconstruction software, that high-quality proton radiographs can be generated for patient alignment and verification of water equivalent thickness of the patient before each treatment.
We describe a cloud-based medical image reconstruction service designed to meet a real-time and daily demand to reconstruct thousands of images from proton cancer treatment facilities worldwide. Rapid reconstruction of a three-dimensional Proton Computed Tomography (pCT) image can require the transfer of 100 GB of data and use of approximately 120 GPU-enabled compute nodes. The nature of proton therapy means that demand for such a service is sporadic and comes from potentially hundreds of clients worldwide. We thus explore the use of a commercial cloud as a scalable and cost-efficient platform for pCT reconstruction. To address the high performance requirements of this application we leverage Amazon Web Services' GPU-enabled cluster resources that are provisioned with high performance networks between nodes. To support episodic demand, we develop an on-demand multi-user provisioning service that can dynamically provision and resize clusters based on image reconstruction requirements, priorities, and wait times. We compare the performance of our pCT reconstruction service running on commercial cloud resources with that of the same application on dedicated local high performance computing resources. We show that we can achieve scalable and on-demand reconstruction of large scale pCT images for simultaneous multi-client requests, processing images in less than 10 minutes for less than $10 per image.
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of more than a million protons individually measured per second, allowing a full CT scan to be completed in six minutes or less of beam time. In order to assess the performance of the scanner for proton radiography as well as computed tomography, we have performed numerous scans of phantoms at the Northwestern Medicine Chicago Proton Center including a custom phantom designed to assess the spatial resolution, a phantom to assess the measurement of relative stopping power, and a dosimetry phantom. Some images, performance, and dosimetry results from those phantom scans are presented together with a description of the instrument, the data acquisition system, and the calibration methods.
Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of relative stopping power measurements with high accuracy within clinically required time frames. Generating accurate relative stopping power values within the shortest amount of time is considered a key goal when developing an image reconstruction software. The existing image reconstruction softwares have successfully met this time frame and even exceeded this time goal, but require clusters with hundreds of processors. This paper describes a novel reconstruction technique using two graphics processing unit devices. The proposed reconstruction technique is tested on both simulated and experimental datasets and on two different systems namely Nvidia K40 and P100 graphics processing units from IBM and Cray. The experimental results demonstrate that our proposed reconstruction method meets both the timing and accuracy with the benefit of having reasonable cost and efficient use of power.
Proton computed tomography (pCT) is a novel medical imaging modality for mapping the distribution of proton relative stopping power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range uncertainty margins are around 3.5%, pCT has the potential to provide more accurate measurements to within 1%. This improved efficiency will be beneficial to proton-therapy planning and pre-treatment verification. A prototype pCT imaging device has recently been developed capable of rapidly acquiring low-dose proton radiographs of head-sized objects. We have also developed an advanced, fast image reconstruction software based on distributed computing that utilizes parallel processors and graphical processing units. The combination of fast data acquisition and fast image reconstruction will enable the availability of RSP images within minutes for use in clinical settings. The performance of our image reconstruction software has been evaluated using data collected by the prototype pCT scanner from several phantoms.
These instructions provide guidelines for preparing manuscripts for submission to the Conference Record (CR) of the 2016 IEEE Nuclear Science Symposium and Medical Imaging Conference. If you are using Microsoft Word to prepare your manuscript, you should use this document as a template. Define all symbols used in the abstract. Do not cite references in the abstract. Do not delete the blank line immediately above the abstract; it sets the footnote at the bottom of this column. Proton computed tomography has been suggested as an imaging technique alternative to x-ray CT for proton therapy treatment planning and image guidance. Dose, image quality, and range prediction accuracy are closely related and the calculation of the dose delivered during a proton CT scan is crucial for characterizing a proton CT scanner. Here we report on the dosimetric evaluation of proton CT scanner using a prototype built by the pCT collaboration between Loma Linda University, the University of California Santa Cruz, and Baylor University. The Catphan CTP554 16 cm acrylic dose phantom, representing a human head, was used to measure the dose to water during a typical proton CT scan at the Northwestern Medicine Chicago Proton Center in Warrenville, Illinois. A Farmer ionization chamber was installed in two locations (centre and periphery of the phantom) and the accumulated charge was measured with the 35040 Advanced Therapy Dosimeter (Fluke Biomedical). The proton CT scanner was exposed to a uniform beam profile of 200 MeV protons on the uniform scanning clinical proton beam line. At a rate of 1 M protons sec it takes 7 minutes in order collect about 400 M protons during a continuous 360 deg rotation. The proton fluence at the level of upstream inner tracker planes during the 7 minutes of exposure was estimated to be 1.4 M protons/cm 2 . The dose to water was 1.46 mGy in the peripheral location and 1.48 mGy in the central location, demonstrating that it is practically uniform across the phantom. According to these results, we can conclude that, based on an initial dosimetric characterization of a prototype pCT scanner conducted on a clinical proton beam line, proton CT is a promising modality for low-dose image guidance and adaptive proton therapy.
Proton computed tomography (pCT) is an imaging modality that has been in development to support targeted dose delivery in proton therapy. It aims to accurately map the distribution of relative stopping power. Because protons traverse material media in non-linear paths, pCT requires individual proton processing. Image reconstruction then becomes a time-consuming process. Clinical-use scenarios that require images from billions of protons in less than ten or fifteen minutes have motivated us to use distributed and hardware-accelerated computing methods to achieve fast image reconstruction. Combined use of MPI and GPUs demonstrates that clinically viable image reconstruction is possible. On a 60-node CPU/GPU computer cluster, we achieved efficient strong and weak scaling when reconstructing images from two billion histories in under seven minutes. This represents a significant improvement over the previous state-of-the-art in pCT, which took almost seventy minutes to reconstruct an image from 131 million histories on a single-CPU, single-GPU computer.
Proton computed tomography (pCT) is an imaging modality being developed to support targeted dose delivery in proton therapy. It aims to accurately map the distribution of relative stopping power in the imaged body. Because protons traverse material in non-linear paths, pCT requires individual proton processing and image reconstruction becomes a time-consuming process. We discuss the transformation of image reconstruction techniques from single CPU/GPU implementations to create a hybrid multi-CPU/GPU approach. We demonstrate a reduction of computation time from almost 7 hours down to 53 seconds.