In the context of the Gamma-Flash program, whose objective is to investigate the emission of high-energy gamma rays and neutrons during thunderstorms, a neutron detection system, based on scintillators coupled to photomultiplier tubes (PMTs), has been developed. The neutrons emitted are generated by photoproduction reactions in the atmosphere, and they have a wide range of energies, from MeV down to meV. In this work, the effects of neutron irradiation on PMTs and their power supply are investigated to assess and quantify the effects of irradiation on dark-count rate and during data acquisition. The detection system was irradiated at the ChipIr beamline at ISIS Neutron and Muon Source, Didcot, U.K. During the irradiation of power supplies, an increase in dark-count rate has been observed, whose magnitude depends on the output voltages and the experimental parameters. In the specific case of our experiment, the dark-count rate went from an average value of 0 to 40 and 120 counts per second (counts/s) at the operating voltage of 1800 and 1900 V, respectively. Even more evident are the effects during the irradiation of the PMTs; in this case, the dark-count rate reaches about 4000 counts/s, high enough to hamper the measurements. These effects, despite their relevance to data acquisition and detector performance, do not produce long-term consequences on the electronic components. Beyond the Gamma-Flash program, this research is relevant, because the use of PMTs is common in many areas of scientific research and radiation detection applications. Our results highlight the need for great care in the interpretation of results in applications where PMTs and their power supplies may be exposed to high radiation fluxes. A proper design of the experiment or shielding strategies could prevent such unwanted behavior in data acquisition.
Phantom materials are used to design radiation safety and protection strategies by means of numerical dose calculation. In the case of thermal neutrons, the radiation transport in the phantom relies on mass attenuation coefficients and total cross sections which are dependent on the physical and chemical properties of the material. Specifically for medical applications, such as neutron capture therapy, the neutron-induced dose is mainly related to the neutron absorption by hydrogen and nitrogen in the human tissue and body. Here, we investigate the use of poly(2-hydroxyethyl methacrylate) as a phantom material by experimental measurement and modeling of its total neutron scattering cross section and mass attenuation coefficient. We show that by varying the hydration level from 10 to 40 w
We provide a concurrent measurement of the hydrogen and oxygen nuclear kinetic energies in the water molecule across melting at 270 K in the solid phase and 276 K in the liquid phase. Experimental values are obtained by analyzing the neutron Compton profiles of each atomic species in a deep inelastic neutron scattering experiment. The concurrent measurement of the atom kinetic energy of both hydrogen and oxygen allows the estimate of the total kinetic energy per molecule due to the motion of nuclei, specifically 35.3 ± 0.8 and 34.8 ± 0.8 kJ/mol for the solid and liquid phases, respectively. Such a small difference supports results from ab initio simulations and phenomenological models from the literature on the mechanism of competing quantum effects across the phase change. Despite the experimental uncertainties, the results are consistent with the trend from state-of-the-art computer simulations, whereby the atom and molecule kinetic energies in the liquid phase would be slightly lower than in the solid phase. Moreover, the small change of nuclear kinetic energy across melting can be used to simplify the calculation of neutron-related environmental dose in complex locations, such as high altitude or polar neutron radiation research stations where liquid water and ice are both present: for neutron energies between hundreds of meV and tens of keV, the total scattering cross section per molecule in the two phases can be considered the same, with the macroscopic cross section only depending upon the density changes of water near the melting point.
BACKGROUND:Boron-containing compounds, such as 4-borono-phenylalanine (BPA) are used as drugs for cancer treatment in the framework of Boron Neutron Capture Therapy (BNCT). Neutron irradiation of boron-rich compounds delivered to cancer cells triggers nuclear reactions that destroy cancer cells.PURPOSE:We provide a modeling of the thermal neutron cross section of BPA, a drug used in Boron Neutron Capture Therapy (BNCT), to quantify the competing contributions of boron absorption against hydrogen scattering, for optimizing BNCT by minimizing the latter.METHODS:We perform the experimental determination of the total neutron scattering cross section of BPA at thermal and epithermal neutron energies using neutron transmission measurements. We isolate the contribution related to the incoherent scattering by hydrogen atoms as a function of the neutron energy by means of the Average Functional Group Approximation, and we calculate the probability for a neutron of being absorbed as a function of the neutron energy both for BPA and for its variants where either one or all four aromatic hydrogen atoms are substituted by 19 F, and both for the samples with natural occurrence or enriched concentration of 10 B.RESULTS:While referring to the already available literature for in vivo use of fluorinated BPA, we show that fluorine-rich variants of BPA increase the probability of neutrons being captured by the molecule. As the higher absorption efficiency of fluorinated BPA does not depend on whether the molecule is used in vivo or not, our results are promising for the higher efficiency of the boron neutron capture treatment.CONCLUSIONS:Our results suggest a new advantage using fluorinated compounds for BNCT, in their optimized interaction with neutrons, in addition to their already known capability to be used for monitoring and pharmacokinetics studies using 19 F-Nuclear Magnetic Resonance or in 18 F-Positron Emission Tomography.
This paper presents the results of the irradiation, performed with atmospheric-like neutrons and heavy-ions, of Commercial Off-the Shelf Components (COTS), which can be used in space missions. In such cases, it is crucial to perform tests in a radiation environment that emulates the environment of different orbits around Earth. In our study we used atmosphericlike neutrons with fluences up to 1011 neutrons/cm-2 and Kr ions of fluences up to 107 ions/cm-2. These intensities are augmented with respect to the atmospheric one in order to shorten the irradiation time while simulating a long-time exposure during a possible mission in Low Earth Orbit (LEO). A similar radiation environment to LEO can also be present during High-Energy Physics experiments. Therefore, the study herby reported can also be helpful for accelerator physics. In this paper we show in detail procedures, setup and results we have obtained on a commercial device normally exploited in automotive environments.
The polymer polyvinylidene fluoride (PVDF) has four phases, each characterized by different molecular configurations of the polymer chains. In its beta phase it arranges in an all-trans configuration with dipolar symmetry, exhibiting piezoelectric effects. During the production of thin PVDF films by spin-coating, the polymer chains are not aligned and the dipoles are not oriented. To achieve the desired piezoelectric behavior, it is necessary to optimize both the chain alignment and the dipole orientation processes. We here present an easy procedure to maximize the percentage of the beta phase in the polymer production. The efficiency and reliability of such method has been assessed through Fourier-Transform Infra-Red and Raman spectroscopies, while the morphological differences of the two phases have been analyzed through Scanning Electron Microscopy. The results confirm the efficiency of this method.
The increasing interest in stretchable conductive composite materials, that can be versatile and suitable for wide-ranging application, has sparked a growing demand for studies of scalable fabrication techniques and specifically tailored geometries. Thanks to the combination of the conductivity and robustness of carbon nanotube (CNT) materials with the viscoelastic properties of polymer films, in particular their stretchability, “surface composites” made of a CNT on polymeric films are a promising way to obtain a low-cost, conductive, elastic, moldable, and patternable material. The use of polymers selected for specific applications, however, requires targeted studies to deeply understand the interface interactions between a CNT and the surface of such polymer films, and in particular the stability and durability of a CNT grafting onto the polymer itself. Here, we present an investigation of the interface properties for a selected group of polymer film substrates with different viscoelastic properties by means of a series of different and complementary experimental techniques. Specifically, we studied the interaction of a single-wall carbon nanotube (SWCNT) deposited on two couples of different polymeric substrates, each one chosen as representative of thermoplastic polymers (i.e., low-density polyethylene (LDPE) and polypropylene (PP)) and thermosetting elastomers (i.e., polyisoprene (PI) and polydimethylsiloxane (PDMS)), respectively. Our results demonstrate that the characteristics of the interface significantly differ for the two classes of polymers with a deeper penetration (up to about 100 μm) into the polymer bulk for the thermosetting substrates. Consequently, the resistance per unit length varies in different ranges, from 1–10 kΩ/cm for typical thermoplastic composite devices (30 μm thick and 2 mm wide) to 0.5–3 MΩ/cm for typical thermosetting elastomer devices (150 μm thick and 2 mm wide). For these reasons, the composites show the different mechanical and electrical responses, therefore suggesting different areas of application of the devices based on such materials.
We provide a worked example on how to obtain the total neutron scattering cross section of organic polymers at thermal neutron energies by means of the Average Functional Group Approximation. Within this framework, a polymer is rationalised as composed of hydrogen atoms belonging to specific functional groups,therefore taking into account the material-specific incoherent inelastic scattering contributions to the thermal cross section. Such simplified model allows the calculation of thermal neutron cross sections for a broad variety of materials of interest in neutron applications, e.g., sample containers and shielding components. We discuss in detail the case of ABS, often available as a 3D-printing material, whereby three polymers (acrylonitrile, butadiene, and styrene) can be combined in several mass percentages depending on the final application. Results are obtained using the NCrystal module already featuring the Average Functional Group Approximation.
Gamma-Flash is an Italian project funded by the Italian Space Agency (ASI) and led by the National Institute for Astrophysics (INAF), devoted to the observation and study of high-energy phenomena, such as terrestrial gamma-ray flashes and gamma-ray glows produced in the Earth's atmosphere during thunderstorms. The project's detectors and the data acquisition and control system (DACS) are placed at the "O. Vittori" observatory on the top of Mt. Cimone (Italy). Another payload will be placed on an aircraft for observations of thunderstorms in the air. This work presents the architecture of the data acquisition and control system and the data flow.
The Museo Egizio’s collection contains 200 precious and unique leather artifacts belonging to different historical periods. The materials used during the tanning and curing procedures affect the chemical and elemental composition of the surface of the samples as well as their preservation status, specifically through the hydration level within the bulk. Here we provide an experimental characterization of a series of samples from Museo Egizio that document an extensive denaturation phenomenon (gelatinization), by combining non-destructive techniques including surface probes (X-ray fluorescence, Raman scattering, and scanning electron microscopy enhanced by X-ray energy spectroscopy) and neutron-based bulk techniques (inelastic and deep-inelastic neutron scattering). Results show partial dehydration of the samples in the bulk, affecting the morphology of their surface, the presence of potassium alum, and iron oxides, as well as phosphates and hydroxides related to the tanning and curing procedures. Finally, we briefly discuss the need for a versatile and adaptable software package that is capable of combining quantitative analyses with complementary techniques including morphological, elemental, and chemical composition.
We present an experimental investigation of methylammonium lead tribromide single crystals in the orthorhombic, tetragonal, and cubic phases based on inelastic and deep inelastic neutron scattering experiments. We show how the average hydrogen nuclear kinetic energy, mainly affected by zero-point vibrational energies, shows differences larger compared to the changes simply related to temperature effects when moving from one phase to another. In particular, the Gaussian contribution to the average nuclear kinetic energy is larger in the tetragonal phase compared to the cubic and orthorhombic ones. Moreover, we find that the vibrational densities of states of MAPbBr3 single crystals in the orthorhombic phase are compatible with previously reported results on powder samples, and that the only vibrational modes that show slightly different frequencies compared to MAPbI3 are those in the energy range between 100 and 300 cm-1, related to librational/rotational modes. As these shifts are of about 10 cm-1 and do not affect any higher-energy vibrational mode, we conclude that the zero-point energies and average nuclear kinetic energies in the two-hybrid organic/inorganic perovskites are expected to be approximately the same within a harmonic framework.
The use of the Average Functional Group Approximation for self-shielding corrections at inelastic neutron spectrometers is discussed. By taking triptindane as a case study, we use the above-mentioned approximation to simulate a synthetic dynamic structure factor as measured on an indirect-geometry spectrometer, as well as the related total scattering cross section as a function of incident neutron energy and sample temperature, and the transmission spectra depending on the sample thickness. These quantities, obtained in a consistent way from the Average Functional Group Approximation, are used to calculate the energy-dependent self-shielding correction affecting the sample under investigation. The impact on the intensities of low-energy vibrational modes is discussed, showing that at typical experimental conditions the sample-dependent attenuation factor is about 15% higher compared to the correction at higher energies.
The limits of detection (LOD) and quantitation (LOQ) in the mass domain, for broadband vibrational spectroscopy with neutrons on the TOSCA spectrometer at the ISIS Pulsed Neutron and Muon Source (UK), have been studied. The well-known 3σ and 10σ approaches are used through a specifically developed analytical procedure that is based on the calculation of the integrated spectral intensities in selected energy-transfer ranges, as a function of mass of standard reference materials and calibrants, such as ZrH2, 2,5-diiodothiophene, and low-density polyethylene. The analysis shows that the blank, that is, the instrument setup without the analyte, plays a critical role in the measurement performance, especially for small specimen quantities. The results point that TOSCA enables detection of 128 μmol (LODH) and quantitation of 428 μmol (LOQH) of elemental hydrogen analytes in ZrH2. The determined values for this and other standards allow for the assessment of the calibration curve design and instrument sensitivity and define a method to be used for inelastic neutron scattering spectrometers such as TOSCA, or VESPA, the new beamline under construction at the European Spallation Source in Lund (Sweden).
The static random access memory (SRAM) of an ultralow power system-on-chip (SoC) was tested for single-event upsets (SEUs) using alpha particles and neutron beam sources. The measurements are compared to those of an SRAM-based field-programmable gate array (FPGA), built on a similar technology node. The results reveal opposite trends in the two devices regarding the upsets of the logic states, as well as differences in the dependence of SEU cross section (CS) on the operation voltage. The sensitivity of the SoC SRAM to multiple bit upsets with the different radiation sources is analyzed as well. The results demonstrate that the unique SoC design, which enables complete near/subthreshold operation, does not compromise the SoC bit upset tolerance compared to devices of similar technology node which operate at higher voltages.
The present study is focused on the development and characterization of innovative cementitious-based composite sensors. In particular, multifunctional cement mortars with enhanced piezoresistive properties are realized by exploiting the concept of confinement of Multiwall Carbon Nanotubes (MWCNTs) and reduced Graphene Oxide (rGO) in a three-dimensional percolated network through the use of a natural-rubber latex aqueous dispersion. The manufactured cement-based composites were characterized by means of Inelastic Neutron Scattering to assess the hydration reactions and the interactions between natural rubber and the hydrated-cement phases and by Scanning Electron Microscopy and X-Ray diffraction to evaluate the morphological and mineralogical structure, respectively. Piezo-resistive properties to assess electro-mechanical behavior in strain condition are also measured. The results show that the presence of natural rubber latex allows to obtain a three-dimensional rGO/MWCNTs segregate structure which catalyzes the formation of hydrated phases of the cement and increases the piezo-resistive sensitivity of mortar composites, representing a reliable approach in developing innovative mortar-based piezoresistive strain sensors.
Extra virgin olive oil (EVOO) is defined as a functional food as it contains numerous phenolic components with well-recognized health-beneficial properties, such as high antioxidant and anti-inflammatory capacity. These characteristics depend on their structural/conformational behavior, which is largely determined by intra- and intermolecular H-bond interactions. While the vibrational dynamics of isolated compounds have been studied in a number of recent investigations, their signal in a real-life sample of EVOO is overwhelmed by the major constituent acids. Here, we provide a full characterization of the vibrational spectroscopic signal from commercially available EVOO samples using Inelastic Neutron Scattering (INS) and Raman spectroscopies. The spectra are dominated by CH2 vibrations, especially at about 750 cm−1 and 1300 cm−1. By comparison with the spectra from hydroxytyrosol and other minor phenolic compounds, we show that the best regions in which to look for the structure–activity information related to the minor polar compounds is at 675 and 1200 cm−1 for hydroxytyrosol, and around 450 cm−1 for all minor polar compounds used as reference, especially if a selectively deuterated sample is available. The regional origin of the EVOO samples investigated appears to be related to the different amount of phenolic esters versus acids as reflected by the relative intensities of the peaks at 1655 and 1747 cm−1.
The present and future developments of time-resolved prompt-gamma activation analysis (T-PGAA) at pulsed neutron sources is discussed in the framework of the successful history of neutron-activation techniques. A brief description of the state of the art and the most important user facilities using standard prompt-gamma activation analysis (PGAA) is provided. Then, we discuss the challenges and the opportunities for T-PGAA at pulsed neutron sources, and the potential impact for applications to cultural heritage, radiation protection, and security. We notice some inversions of trend needed for the further development of T-PGAA with epithermal and fast neutrons, such as the possibility to use fast and high-efficiency γ-ray scintillators with lower energy resolution (compared to usual high-purity germanium detectors) when the signal from neutron capture resonance is selected. We also suggest how detection systems often used in other fields, such as medical physics, can be of interest and inspiration also in the case of neutron-based investigations. Finally, we present new data of T-PGAA measurements on VESUVIO using neutron energies up to the keV using the scintillators available on the instrument, for samples of gold (of interest in cultural heritage), cadmium (for environmental safety), and tantalum (a material used in biomedical implants).
The experimental thermal neutron cross sections of the 20 proteinogenic amino acids have been measured over the incident-neutron energy range spanning from 1 meV to 10 keV and data have been interpreted using the multi-phonon expansion based on first-principles calculations. The scattering cross section, dominated by the incoherent inelastic contribution from the hydrogen atoms, can be rationalised in terms of the average contributions of different functional groups, thus neglecting their correlation. These results can be used for modelling the total neutron cross sections of complex organic systems like proteins, muscles, or human tissues from a limited number of starting input functions. This simplification is of crucial importance for fine-tuning of transport simulations used in medical applications, including boron neutron capture therapy as well as secondary neutrons-emission induced during proton therapy. Moreover, the parametrized neutron cross sections allow a better treatment of neutron scattering experiments, providing detailed sample self-attenuation corrections for a variety of biological and soft-matter systems.
Muon tomography is a very promising imaging technique for the control of cargo containers. It takes advantage of cosmic muons and their interaction mechanisms to reconstruct images of the volume traversed by these particles. In the present work, the imaging performance of a novel muon tomography scanner based on resistive plate chambers detectors is investigated. By means of several Monte Carlo simulations, some imaging parameters are evaluated. The results in terms of spatial resolution, field-of-view and volume and material recognition make the presented scanner and its geometry suitable for muon tomography.
Neutron News 2 Science Snapshot Towards Neutron Scattering Identification of Olive Oil’s Antioxidant Properties Roberto Senesi1 , Carla Andreani1 , Piero Baglioni2, Luis A. E. Batista de Carvalho3 , Silvia Licoccia4 , Maria P. M. Marques3,5 , Giulia Moretti2, Annalisa Noce6 , Roberto Paolesse4 , Stewart F. Parker7 , Enrico Preziosi1, Giovanni Romanelli7 , Annalisa Romani8, and Nicola Di Daniele6 1 Physics Department and NAST Centre, Università degli Studi di Roma “Tor Vergata”, Rome, Italy 2 CSGI and Chemistry Department, University of Florence, Florence, Italy 3 Molecular Physical-Chemistry R&D Unit, Department of Chemistry, University of Coimbra, Coimbra, Portugal 4 Chemical Science and Technologies Department and NAST Centre, Università degli Studi di Roma “Tor Vergata”, Rome, Italy 5 Department of Life Sciences, University of Coimbra, Coimbra, Portugal 6 UOC of Internal Medicine-Center of Hypertension and Nephrology Unit, Department of Systems Medicine, Università degli Studi di Roma “Tor Vergata”, Rome, Italy 7 ISIS Facility, STFC Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire, UK 8 PHYTOLAB (Pharmaceutical, Cosmetic, Food Supplement, Technology and Analysis)-DiSIA, University of Florence, Sesto Fiorentino, Italy roberto.senesi@uniroma2.it