Background: Screw loosening remains a prominent complication for osteoporotic patients with pedicle screw fixation surgeries, yet with limited risk assessment approach. The aim of this study was to investigate influence of craniocaudal cyclic load on pedicle screw fixation strength by computed tomography (CT) based finite element analysis (FEA) and we examined predict ability in pedicle screw loosening (PSL). Methods: 12 clinical PSL cases (7 men, 5 women) and 12 age- and sex-matched controls were enrolled for CT based FEA. Simple axial pullout load and axial pullout load with preset craniocaudal cyclic load were applied to each model respectively, and the ultimate pullout force under both conditions is calculated as the fixed strength and compared. Besides, HU values of the vertebral body trabeculae and screw trajectory were measured as an assessment of osteoporosis. The ultimate pullout force and HU value were compared between PSL and controls cases. Results The cyclic load remarkably reduce the pullout force of pedicle screws (906.2 ± 180.2 N vs. 729.3 ± 172.3 N, p<0.0001) by CT based FEA. No significant difference between the PSL and the control group in the simple axial pull-out force and HU values of the vertebral body. But the pullout force with preset cyclic load (639.2 ± 169.4 N vs. 819.4 ± 125.1 N, p = 0.072) and the HU value of the screw trajectory (177.5 ± 43.8 vs. 217.2 ± 29.6, p = 0.016) in the PSL group is significantly lower than that in the control group. Area under receiver operating characteristic curve (ROC) revealed pullout force with preset cyclic load slightly better predicted PSL than HU value of the screw trajectory (AUC = 0.798 vs. 0.750). Conclusions The craniocaudal cyclic load significantly reduces the screw fixation strength. HU value of screw trajectory and pullout force with preset cyclic load by CT based FEA are helpful for the clinical prediction of PSL.
Background Dual-energy computed tomography (DECT) has demonstrated the feasibility of using HAP-water to respond to BMD changes without requiring dedicated software or calibration. Artificial intelligence (AI) has been utilized for the diagnosis of osteoporosis in routine CT scans but has rarely been used in DECT. This study investigated the diagnostic performance of an AI system for osteoporosis screening using DECT images with reference quantitative CT (QCT) images. Methods This prospective study included 120 patients who underwent DECT and QCT scans from August to December 2023. Two convolutional neural networks, 3D RetinaNet, and 3D U-Net, were employed for automated vertebral body segmentation. The accuracy of the BMD measurements was assessed with relative measurement error (RME%). Linear regression and Bland–Altman analyses were performed to compare the BMD values between the AI and manual systems with those of the QCT. The diagnostic performance of the AI and manual systems for osteoporosis and low BMD was evaluated using receiver operating characteristic (ROC) curve analysis. Results The overall mean RMEs for the AI and manual systems were − 15.93 ± 12.05 % and − 25.47 ± 14.83 %, respectively. BMD measurements using the AI system achieved greater agreement with the QCT results than those using the manual system (R2 = 0.946, 0.898, p < 0.001; mean bias, 23.27, 35.71 mg/cm3; 95 % LoA, −9.72 to 56.26, −11.45 to 82.87 mg/cm3). The areas under the curve for the AI and manual systems were 0.933–0.979 for detecting osteoporosis and 0.980–0.991 for low BMD. Conclusion This AI system could achieve relatively high accuracy for automated BMD measurement on DECT scans, providing great potential for the follow-up of BMD in osteoporosis screening.
Thus, the aim of this study is to evaluate the performance of deep learning imaging reconstruction (DLIR) algorithm in different image sets derived from carotid dual-energy computed tomography angiography (DECTA) for evaluating cervical intervertebral discs (IVDs) and compare them with those reconstructed using adaptive statistical iterative reconstruction-Veo (ASiR-V). Forty-two patients who underwent carotid DECTA were included in this retrospective analysis. Three types of image sets (70 keV, water-iodine, and water-calcium) were reconstructed using 50% ASiR-V and DLIR at medium and high levels (DLIR-M and DLIR-H). The diagnostic acceptability and conspicuity of IVDs were assessed using a 5-point scale. Hounsfield Units (HU) and water concentration (WC) values of the IVDs; standard deviation (SD); and coefficient of variation (CV) were calculated. Measurement parameters of the 50% ASIR-V, DLIR-M, and DLIR-H groups were compared. The DLIR-H group showed higher scores for diagnostic acceptability and conspicuity, as well as lower SD values for HU and WC than the ASiR-V and DLIR-M groups for the 70 keV and water-iodine image sets (all p < .001). However, there was no significant difference in scores and SD among the three groups for the water-calcium image set (all p > .005). The water-calcium image set showed better diagnostic accuracy for evaluating IVDs compared to the other image sets. The inter-rater agreement using ASiR-V, DLIR-M, and DLIR-H was good for the 70 keV image set, excellent for the water-iodine and water-calcium image sets. DLIR improved the visualization of IVDs in the 70 keV and water-iodine image sets. However, its improvement on color-coded water-calcium image set was limited.
Background Early cervical spondylotic myelopathy (CSM) is challenging to diagnose and easily missed. Diffusion MRI (dMRI) has the potential to identify early CSM. Methods Using diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), and neurite orientation dispersion and density imaging (NODDI), a 1:1 matched case-control study was conducted to evaluate the potential of dMRI in identifying early CSM and assessing uncompressed segments of CSM patients. CSM patients and volunteers were matched by age and spinal location. The differences in dMRI parameters between groups were assessed by the paired t -test, the multicollinearity of the dMRI parameters was evaluated by the variance inflation factor (VIF), and the value of dMRI parameters in distinguishing controls from CSM patients was determined by logistic regression. The univariate t -test was used to analyse differences between CSM patients and volunteers in adjacent uncompressed areas. Results In total, 56 CSM patients and 56 control volunteers were included. Paired t -tests revealed significant differences in nine dMRI parameters between groups. Multicollinearity calculated through VIF and combined with logistic regression showed that the orientation division index (ODI) was significantly positively correlated ( r = 2.12, p = 0.035), and the anisotropic water fraction (AWF) was significantly negatively correlated ( r = −0.98, p = 0.015). The fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD), isotropic volume fraction (ISOVF), ODI, and AWF were significantly different in the upper and lower uncompressed areas at all ages. Conclusion dMRI can noninvasively identify early CSM patients and potentially identify the extent of CSM lesions involving the cervical spinal cord. Critical relevance statement Diffusion MRI (dMRI) can identify early cervical spondylotic myelopathy (CSM) and has the potential to help determine the extent of CSM involvement. The application of dMRI can help screen for early CSM and develop clinical surgical and rehabilitation treatment plans. Key points • Diffusion MRI can differentiate between normal and early-stage cervical spondylotic myelopathy patients. • Diffusion MRI has the ability to identify the extent of spinal cord involvement in cervical spondylotic myelopathy. • Diffusion MRI enables the early screening of cervical spondylotic myelopathy and helps guide clinical treatment. Graphical Abstract
BACKGROUND:Dual-energy computed tomography (DECT) has demonstrated the feasibility of using HAP-water to respond to BMD changes without requiring dedicated software or calibration. Artificial intelligence (AI) has been utilized for diagnosising osteoporosis in routine CT scans but has rarely been used in DECT. This study investigated the diagnostic performance of an AI system for osteoporosis screening using DECT images with reference quantitative CT (QCT). METHODS:This prospective study included 120 patients who underwent DECT and QCT scans from August to December 2023. Two convolutional neural networks, 3D RetinaNet and U-Net, were employed for automated vertebral body segmentation. The accuracy of the bone mineral density (BMD) measurement was assessed with relative measurement error (RME%). Linear regression and Bland-Altman analyses were performed to compare the BMD values between the AI and manual systems with those of the QCT. The diagnostic performance of the AI and manual systems for osteoporosis and low BMD was evaluated using receiver operating characteristic curve analysis. RESULTS:The overall mean RME% for the AI and manual systems were - 15.93 ± 12.05 % and - 25.47 ± 14.83 %, respectively. BMD measurements using the AI system achieved greater agreement with the QCT results than those using the manual system (R2 = 0.973, 0.948, p < 0.001; mean errors, 23.27, 35.71 mg/cm3; 95 % LoA, -9.72 to 56.26, -11.45 to 82.87 mg/cm3). The areas under the curve for the AI and manual systems were 0.979 and 0.933 for detecting osteoporosis and 0.980 and 0.991 for low BMD. CONCLUSION:This AI system could achieve relatively high accuracy for automated BMD measurement on DECT scans, providing great potential for the follow-up of BMD in osteoporosis screening.
BACKGROUND:Diffusion magnetic resonsance imaging (dMRI) can potentially predict the postoperative outcome of cervical spondylotic myelopathy (CSM). PURPOSE:To explore preoperative dMRI parameters to predict the postoperative outcome of CSM through multifactor correlation analysis. STUDY TYPE:Prospective. POPULATION:Post-surgery CSM patients; 102 total, 73 male (52.42 ± 10.60 years old) and 29 female (52.0 ± 11.45 years old). FIELD STRENGTH/SEQUENCE:3.0 T/Turbo spin echo T1/T2-weighted, T2*-weighted multiecho gradient echo and dMRI. ASSESSMENT:Spinal cord function was evaluated using modified Japanese Orthopedic Association (mJOA) scoring at different time points: preoperative and 3, 6, and 12 months postoperative. Single-factor correlation and t test analyses were conducted based on fractional anisotropy (FA), mean diffusivity, intracellular volume fraction, isotropic volume fraction, orientation division index, increased signal intensity, compression ratio, age, sex, symptom duration and operation method, and multicollinearity was calculated. The linear quantile mixed model (LQMM) and the linear mixed-effects regression model (LMER) were used for multifactor correlation analysis using the combinations of the above variables. STATISTICAL TESTS:Distance correlation, Pearson's correlation, multiscale graph correlation and t tests were used for the single-factor correlation analyses. The variance inflation factor (VIF) was used to calculate multicollinearity. LQMM and LMER were used for multifactor correlation analyses. P < 0.05 was considered statistically significant. RESULTS:The single-factor correlation between all variables and the postoperative mJOA score was weak (all r < 0.3). The linear relationship was stronger than the nonlinear relationship, and there was no significant multicollinearity (VIF = 1.10-1.94). FA values in the LQMM and LMER models had a significant positive correlation with the mJOA score (r = 5.27-6.04), which was stronger than the other variables. DATA CONCLUSION:The FA value based on dMRI significantly positively correlated with CSM patient postoperative outcomes, helping to predict the surgical outcome and formulate a treatment plan before surgery. EVIDENCE LEVEL:1 TECHNICAL EFFICACY: Stage 2.
To investigate the potential applicability of AI-assisted compressed sensing (ACS) in knee MRI to enhance and optimize the scanning process. Volunteers and patients with sports-related injuries underwent prospective MRI scans with a range of acceleration techniques. The volunteers were subjected to varied ACS acceleration levels to ascertain the most effective level. Patients underwent scans at the determined optimal 3D-ACS acceleration level, and 3D compressed sensing (CS) and 2D parallel acquisition technology (PAT) scans were performed. The resultant 3D-ACS images underwent 3.5 mm/2.0 mm multiplanar reconstruction (MPR). Experienced radiologists evaluated and compared the quality of images obtained by 3D-ACS-MRI and 3D-CS-MRI, 3.5 mm/2.0 mm MPR and 2D-PAT-MRI, diagnosed diseases, and compared the results with the arthroscopic findings. The diagnostic agreement was evaluated using Cohen’s kappa correlation coefficient, and both absolute and relative evaluation methods were utilized for objective assessment. The study involved 15 volunteers and 53 patients. An acceleration factor of 10.69 × was identified as optimal. The quality evaluation showed that 3D-ACS provided poorer bone structure visualization, and improved cartilage visualization and less satisfactory axial images with 3.5 mm/2.0 mm MPR than 2D-PAT. In terms of objective evaluation, the relative evaluation yielded satisfactory results across different groups, while the absolute evaluation revealed significant variances in most features. Nevertheless, high levels of diagnostic agreement (κ: 0.81–0.94) and accuracy (0.83–0.98) were observed across all diagnoses. ACS technology presents significant potential as a replacement for traditional CS in 3D-MRI knee scans, allowing thinner MPRs and markedly faster scans without sacrificing diagnostic accuracy. 3D-ACS-MRI of the knee can be completed in the 160 s with good diagnostic consistency and image quality. 3D-MRI-MPR can replace 2D-MRI and reconstruct images with thinner slices, which helps to optimize the current MRI examination process and shorten scanning time. • AI-assisted compressed sensing technology can reduce knee MRI scan time by over 50 • 3D AI-assisted compressed sensing MRI and related multiplanar reconstruction can replace traditional accelerated MRI and yield thinner 2D multiplanar reconstructions. • Successful application of 3D AI-assisted compressed sensing MRI can help optimize the current knee MRI process.
Purpose MR arthrography (MRA) is the most accurate method for preoperatively diagnosing superior labrum anterior–posterior (SLAP) lesions, but diagnostic results can vary considerably due to factors such as experience. In this study, deep learning was used to facilitate the preliminary identification of SLAP lesions and compared with radiologists of different seniority. Methods MRA data from 636 patients were retrospectively collected, and all patients were classified as having/not having SLAP lesions according to shoulder arthroscopy. The SLAP-Net model was built and tested on 514 patients (dataset 1) and independently tested on data from two other MRI devices (122 patients, dataset 2). Manual diagnosis was performed by three radiologists with different seniority levels and compared with SLAP-Net outputs. Model performance was evaluated by the receiver operating characteristic (ROC) curve, area under the ROC curve (AUC), etc. McNemar’s test was used to compare performance among models and between radiologists’ models. The intraclass correlation coefficient (ICC) was used to assess the radiologists’ reliability. p < 0.05 was considered statistically significant. Results SLAP-Net had AUC = 0.98 and accuracy = 0.96 for classification in dataset 1 and AUC = 0.92 and accuracy = 0.85 in dataset 2. In dataset 1, SLAP-Net had diagnostic performance similar to that of senior radiologists ( p = 0.055) but higher than that of early- and mid-career radiologists ( p = 0.025 and 0.011). In dataset 2, SLAP-Net had similar diagnostic performance to radiologists of all three seniority levels ( p = 0.468, 0.289, and 0.495, respectively). Conclusions Deep learning can be used to identify SLAP lesions upon initial MR arthrography examination. SLAP-Net performs comparably to senior radiologists.
PurposeThis study aimed to evaluate the difference in vertebral mechanical properties estimated by finite element analysis (FEA) with different computed tomography (CT) reconstruction kernels and evaluate their accuracy in the screening and classification of osteoporosis. MethodsThere were 31 patients enrolled retrospectively from the quantitative CT database of our hospital, uniformly covering the range from osteoporosis to normal. All subjects' CT raw data were reconstructed both with a smooth standard convolution kernel (B40f) and a sharpening bone convolution kernel (B70f), and FEA was performed on L1 of each subject based on two reconstructed images to obtain vertebral estimated strength and stiffness. The trabecular volumetric bone mineral density (vBMD) of the same vertebral body was also measured. FEA measurements between two kernels and their accuracy for osteoporosis screening were compared. ResultsThe vertebral stiffness and strength measured in FEA-B40f were significantly lower compared with those of FEA-B70f (12.0%, p = 0.000 and 10.7%, p = 0.000, respectively). The correlation coefficient between FEA-B70F and vBMD was slightly higher than that of FEA-B40F in both vertebral strength and stiffness (strength: r(2)-B40f = 0.21, p = 0.009 vs. r(2)-B70f = 0.27, p = 0.003; stiffness: r(2)-B40f = 0.37, p = 0.002 vs. r(2)-B70f = 0.45, p=0.000). The receiver operator characteristic curve showed little difference in the classification of osteoporosis between FEA-B40f and FEA-B70f. ConclusionTwo kernels both seemed to be applicable to the opportunistic screening of osteoporosis by CT-FEA despite variance in FE-estimated bone strength and bone stiffness. A protocol for CT acquisition and FEA is still required to guarantee the reproducibility of clinical use.
Abstract Objectives To evaluate image quality and diagnostic performance of carotid dual-energy computed tomography angiography (DECTA) using deep learning image reconstruction (DLIR) compared with images using adaptive statistical iterative reconstruction-Veo (ASIR-V). Methods Carotid DECTA datasets of 28 consecutive patients were reconstructed at 50 keV using DLIR at low, medium, and high levels (DLIR-L, DLIR-M, and DLIR-H) and 80% ASIR-V algorithms. Mean attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) at different levels of arteries were measured and calculated. Image quality for noise and texture, depiction of arteries, and diagnostic performance toward carotid plaques were assessed subjectively by two radiologists. Quantitative and qualitative parameters were compared between the ASIR-V, DLIR-L, DLIR-M, and DLIR-H groups. Results The image noise at aorta and common carotid artery, SNR, and CNR at all level arteries of DLIR-H images were significantly higher than those of ASIR-V images (p = 0.000–0.040). The quantitative analysis of DLIR-L and DLIR-M showed comparable denoise capability with ASIR-V. The overall image quality (p = 0.000) and image noise (p = 0.000–0.014) were significantly better in the DLIR-M and DLIR-H images. The image texture was improved by DLR at all level compared to ASIR-V images (p = 0.000–0.008). Depictions of head and neck arteries and diagnostic performance were comparable between four groups (p > 0.05). Conclusions Compared with 80% ASIR-V, we recommend DLIR-H for clinical carotid DECTA reconstruction, which can significantly improve the image quality of carotid DECTA at 50 keV but maintain a desirable diagnostic performance and arterial depiction.