This roadmap provides a comprehensive and forward-looking perspective on the individualized application and safety of non-ionizing radiation (NIR) dosimetry in diagnostic and therapeutic medicine. Covering a wide range of frequencies, i.e., from low-frequency to terahertz, this document provides an overview of the current state of the art and anticipates future research needs in selected key topics of NIR-based medical applications. It also emphasizes the importance of personalized dosimetry, rigorous safety evaluation, and interdisciplinary collaboration to ensure safe and effective integration of NIR technologies in modern therapy and diagnosis.
Current microwave ablation applicators rely on invasive needlelike antennas, which must be inserted into tissue to deliver effective heating. This study presents a compact, non-invasive patch antenna for microwave ablation at 2.45 GHz, designed for surface placement on biological tissue. Through an iterative design process, the antenna parameters were refined using numerical simulations that incorporate temperature-dependent dielectric and thermal properties to achieve ablation depths greater than 10 mm. Temperature increases during ablation were validated experimentally for power levels of 20 W and 40 W over 300 s. The results demonstrate the feasibility of a non-invasive alternative for microwave ablation, with potential implications for clinical applications where surface ablation is needed. Simulations accurately predict temperature changes during experimental ablations with a maximum percent error of 3 % and confirm that ablation depths exceeding 10 mm are achieved.
Purpose: To evaluate safety and oncologic efficacy of percutaneous microwave ablation (MWA) for treating clinically localized T1b (cT1b) renal cell carcinoma (RCC). Methods: This single-center retrospective study was performed under a waiver of informed consent. Seventy-four consecutive patients (49M/25F) with 76 cT1b RCC (median tumor diameter 4.5 cm) were treated with percutaneous MWA between 5/2012 and 8/2020. Patients were stratified into two groups by technique, depending on whether antennas were repositioned for additional ablation or not. Primary efficacy, complications, and local tumor progression (LTP) were compared using the Wilcoxon rank sum and Fisher’s exact tests. The Kaplan Meier method was used for survival analysis. Results: Patients were elderly (median age 69.5), obese (median BMI 34.5) and comorbid (Charlson Comorbidity Index = 4). Most tumors were low-grade (grade 1-2) (67/89, 88%) and clear cell RCC was the most common histology (62/76, 82%). A median of three MWA antennas were powered at 65W for 7 min for treatment. Renal masses were larger (4.6 vs 4.5 cm, p=0.01) and procedure times longer (100 min vs 80.5 min, p=0.04) for the antenna reposition cohort (n=34, 45%). Primary efficacy and high-grade complication rates were 93% and 8%, respectively. The local tumor progression rate (LTP), at a median follow-up was 28.2 months, was 16%. Primary efficacy, low and high-grade complications, change in estimated glomerular filtration rate and LTP were similar between cohorts (p=0.20-0.55). Conclusion: Percutaneous MWA for cT1b RCC is safe in elderly and comorbid patients with acceptable oncologic efficacy. Repeat ablation is well-tolerated and can improve oncologic efficacy.
Background Different surgical methods for epiphysiodesis of limb length discrepancy (LLD) have been described. Although these methods are variably effective, they are associated with morbidity (pain and limp) and potential complications. Microwave ablation is a less-invasive opportunity to halt growth by selectively destroying the growth plate via thermal energy to treat LLD in children. Questions/purposes In this proof-of-concept study using an in vivo pig model, we asked: (1) What is the durability of response 2 to 4 months after microwave ablation of the tibial growth plate as measured by length and angulation of the tibia via a CT scan? (2) Was articular cartilage maintained as measured by standard histologic staining for articular cartilage viability? Methods To develop an in vivo protocol for microwave ablation, we placed microwave antennas adjacent to the proximal tibia growth plate in the cadaveric hindlimbs of 18 3-month-old pigs. To determine the suitable time, we varied ablation from 90 to 270 seconds at 65-W power settings. After sectioning the tibia, we visually assessed for discoloration (implying growth plate destruction) that included the central growth plate but did not encroach into the epiphysis in a manner that could disrupt the articular surface. Using this information, we then performed microwave ablation on three live female pigs (3.5 to 4 months old) to evaluate physiologic changes and durability of response. A postprocedure MRI was performed to ensure the intervention led to spatial growth plate alterations similar to that seen in cadavers. This was followed by serial CT, which was used to assess the potential effect on local bone and growth until the animals were euthanized 2 to 4 months after the procedure. We analyzed LLD, angular deformity, and bony deformity using CT scans of both tibias. The visibility of articular cartilage was compared with that of the contralateral tibia via standard histologic staining, and growth rates of the proximal tibial growth plate were compared via fluorochrome labeling. Results Eighteen cadaveric specimens showed ablation zones across the growth plate without visual damage to the articular surface. The three live pigs did not exhibit changes in gait or require notable pain medication after the procedure. Each animal demonstrated growth plate destruction, expected limb shortening (0.8, 1.2, and 1.5 cm), and bony cavitation around the growth plate. Slight valgus bone angulation (4º, 5º, and 12º) compared with the control tibia was noted. No qualitatively observable articular cartilage damage was encountered from the histologic comparison with the contralateral tibia for articular cartilage thickness and cellular morphology. Conclusion A microwave antenna placed into a pig’s proximal tibia growth plate can slow the growth of the tibia without apparent pain and alteration of gait and function. Clinical Relevance Further investigation and refinement of our animal model is ongoing and includes shorter ablation times and comparison of dynamic ablation (moving the antennae during the ablation) as well as static ablation of the tibia from a medial and lateral portal. These refinements and planned comparison with standard mechanical growth arrest in our pig model may lead to a similar approach to ablate growth plates in children with LLD.
PURPOSE:To determine the feasibility of using a 2-dimensional quantitative digital subtraction venography (qDSV) technique that employs a temporally modulated contrast medium injection to quantify blood velocity in phantom, normal, and stenotic porcine iliac vein models. MATERIALS AND METHODS:Blood velocity was calculated using qDSV following temporally modulated pulsed injections of iodinated contrast medium and compared with Doppler ultrasound (US) measurements (phantom, in-line sensor; in vivo, diagnostic linear probe). Phantom evaluation was performed in a compliant polyethylene tube phantom with simulated venous flow. In vivo evaluation of qDSV was performed in normal (n = 7) and stenotic (n = 3) iliac vein models. Stenoses were created using endovenous radiofrequency ablation, and blood velocities were determined at baseline, after stenosis, after venoplasty, and after stent placement. RESULTS:In the phantom model, qDSV-calculated blood velocities (12-50 cm/s) had very strong correlations with US-measured velocities (13-51 cm/s) across a range of baseline blood velocities and injection protocols (slope, 1.01-1.13; R2 = 0.96-0.99). qDSV velocities were similar to US velocities regardless of injection method: (a) custom injector, (b) commercial injector, or (c) hand injection. In the normal in vivo model, qDSV-calculated velocities (5-18 cm/s) had strong correlation (slope, 1.22; R2 = 0.90) with US-measured velocities (3-20 cm/s). In the stenosis model, blood velocities at baseline, after stenosis, after venoplasty, and after stent placement were similar on qDSV and US at all time points. CONCLUSIONS:Venous blood velocity was accurately quantified in a venous phantom and in vivo porcine models using qDSV. Intraprocedural changes in porcine iliac vein blood velocity were quantified with qDSV after creation of a stenosis and subsequently treating it with venoplasty and stent placement.
The heterogeneity of hepatocellular carcinoma may be better seen with magnetic resonance imaging (MRI) compared with CT due to its high soft tissue contrast, providing precise tumor targets during therapy, while ultrasound (US) remains as the imaging modality for real-time guidance. Image fusion methods existing in clinical workflows involve rigid registration only and fail to compensate for liver motion in US. In this work, we present a hybrid deformable fusion method to align pre-interventional 3D MRI and interventional 3D US in real-time. Multimodal pre-interventional MRI (pMRI) and US (pUS) volumes were obtained from 3 human volunteers using a simultaneous MRI-US acquisition system, with an MR-compatible, hands-free US probe. pMRI and pUS volumes were aligned using conventional deformable registration, as it is not time critical. Deep learning (DL)–based registration was used for real-time fusion of pUS to iUS, and consecutive iUS volumes in near real time. The predicted DL deformation fields were used to deform the pMRI to match each US volume. US data with respiration were collected at a temporal resolution of 4.2 volumes/sec. 1600 US volumes from one volunteer was used for DL training. The hybrid deformable registration method was evaluated for pMRI and 20 US volume alignments for each volunteer. Mean Euclidean distance error between expert placed landmarks and predicted positions of landmarks after image alignment were computed. Table 1 shows the mean landmark error (LE) and computation times for the hybrid (HDR) and conventional deformable registration (CDR) method aligning pMRI and 20 US volumes. Feasibility of a multimodal hybrid deformable registration method with clinically acceptable registration accuracy and low latency was shown. The method for motion compensation may improve tumor targeting in interventional procedures including liver ablation.
Purpose Ultrasound is often the preferred modality for image-guided therapy or treatment in organs such as liver due to real-time imaging capabilities. However, the reduced conspicuity of tumors in ultrasound images adversely impacts the precision and accuracy of treatment delivery. This problem is compounded by deformable motion due to breathing and other physiological activity. This creates the need for a fusion method to align interventional US with pre-interventional modalities that provide superior soft-tissue contrast (e.g., MRI) to accurately target a structure-of-interest and compensate for liver motion. Method In this work, we developed a hybrid deformable fusion method to align 3D pre-interventional MRI and 3D interventional US volumes to target the structures-of-interest in liver accurately in real-time. The deformable multimodal fusion method involved an offline alignment of a pre-interventionMRI with a pre-interventionUS volume using a traditional registration method, followed by real-time prediction of deformation using a trained deep-learning model between interventional US volumes across different respiratory states. This framework enables motion-compensated MRI-US image fusion in real-time for image-guided treatment. Results The proposed hybrid deformable registration method was evaluated on three healthy volunteers across the pre-intervention MRI and 20 US volume pairs in the free-breathing respiratory cycle. The mean Euclidean landmark distance of three homologous targets in all three volunteers was less than 3 mm for percutaneous liver procedures. Conclusions Preliminary results show that clinically acceptable registration accuracies for near real-time, deformable MRI-US fusion can be achieved by our proposed hybrid approach. The proposed combination of traditional and deep-learning deformable registration techniques is thus a promising approach formotion-compensated MRI-US fusion to improve targeting in image-guided liver interventions.
Objective. Existing clinical C-arm interventional systems use scintillator-based energy-integrating flat panel detectors (FPDs) to generate cone-beam CT (CBCT) images. Despite its volumetric coverage, FPD-CBCT does not provide sufficient low-contrast detectability desired for certain interventional procedures. The purpose of this work was to develop a C-arm photon counting detector (PCD) CT system with a step-and-shoot data acquisition method to further improve the tomographic imaging performance of interventional systems. Approach. As a proof-of-concept, a cadmium telluride-based 51 cm × 0.6 cm PCD was mounted in front of a FPD in an Artis Zee biplane system. A total of 10 C-arm sweeps (5 forward and 5 backward) were prescribed. A motorized patient table prototype was synchronized with the C-arm system such that it translates the object by a designated distance during the sub-second rest time in between gantry sweeps. To evaluate whether this multi-sweep step-and-shoot acquisition strategy can generate high-quality and volumetric PCD-CT images without geometric distortion artifacts, experiments were performed using physical phantoms, a human cadaver head, and an in vivo swine subject. Comparison with FPD-CT was made under matched narrow beam collimation and radiation dose conditions. Main results. Compared with FPD-CT images, PCD-CT images had lower noise and improved visualization of low-contrast lesion models, as well as improved visibility of small iodinated blood vessels. Fine structures were visualized more clearly by the PCD-CT than the highest-available resolution provided by FPD-CBCT and MDCT. No perceivable geometric distortion artifacts were observed in the multi-planar PCD-CT images. Significance. This work is the first demonstration of the feasibility of high-quality and multi-planar (volumetric) PCD-CT imaging with a rotating C-arm gantry.
To compare image quality and radiation dose between single-bolus 2-phase and split-bolus 1-phase CT Urography (CTU) performed immediately after microwave ablation (MWA) of clinically localized T1 (cT1) RCC. Forty-two consecutive patients (30 M, mean age 67.5 ± 9.0) with cT1 RCC were treated with MWA from 7/2013 to 12/2013 at two academic quaternary-care institutions. Renal parenchymal enhancement, collecting system opacification and distention and size-specific dose estimate (SSDE) were quantified and image quality subjectively assessed on single-bolus 2-phase versus split-bolus 1-phase CTU. Kruskal–Wallis and Pearson’s Chi-squared tests were performed to assess differences in continuous and categorical variables, respectively. Two-sample T test with equal variances was used to determine differences in quantitative and qualitative image data. Median tumor diameter was larger [2.9 cm (IQR 1.7–5.3) vs 3.6 cm (IQR 1.7–5.7), p = 0.01] in the split-bolus cohort. Mean abdominal girth (p = 0.20) was similar. Number of antennas used and unenhanced CTs obtained before and during MWA were similar (p = 0.11–0.32). Renal pelvis opacification (2.5 vs 3.5, p < 0.001) and distention (4 mm vs 8 mm, p < 0.001) were improved and renal enhancement (Right: 127 HU vs 177 HU, p = 0.001; Left: 124 HU vs 185 HU, p < 0.001) was higher for the split-bolus CTU. Image quality was superior for split-bolus CTU (3.2 vs 4.0, p = 0.004). Mean SSDE for the split-bolus CTU was significantly lower [163.9 mGy (SD ± 73.9) vs 36.3 mGy (SD ± 7.7), p < 0.001]. Split-bolus CTU immediately after MWA of cT1 RCC offers higher image quality, improved opacification/distention of the collecting system and renal parenchymal enhancement at a lower radiation dose.
To evaluate the effect of intra-procedural contrast-enhanced CT (CECT) and same-session repeat ablation (SSRA) on primary efficacy, the complete eradication of tumor after the first ablation session as confirmed on first imaging follow-up, of clinically localized T1a (cT1a) renal cell carcinoma (RCC). 398 consecutive patients with cT1a RCC were treated with cryoablation between 10/2003 and 12/2017, radiofrequency (RFA) or microwave ablation (MWA) between 1/2010 and 12/2017. SSRA was performed for residual tumor identified on intra-procedural CECT. Kruskal–Wallis and Pearson’s chi-squared tests were performed to assess differences in continuous and categorical variables, respectively. Multivariate linear regression was used to determine predictors for primary efficacy and decline in estimated glomerular filtration rate. 347 consecutive patients (231 M, mean age 67.5 ± 9.1 years) were included. Median tumor diameter was smaller [2.5 vs 2.7 vs 2.6 (p = 0.03)] and RENAL Nephrometry Score (NS) was lower [6 vs 7 vs 7 (p = 0.009] for MWA compared to the RFA and cryoablation cohorts, respectively. Primary efficacy was higher in the MWA cohort [99.4% (170/171)] compared to the RFA [91.4% (85/93)] and cryoablation [92.8% (77/83)] cohorts (p = 0.001). Microwave ablation and SSRA was associated with higher primary efficacy on multivariate linear regression (p = 0.01–0.03). MWA augmented by SSRA, when residual tumor is identified on intra-procedural CECT, may improve primary efficacy for cT1a RCC.
Recent studies have shown that ablation techniques have the potential to eradicate adrenal adenomas while preserving the functionalities of the adrenal gland and the surrounding anatomical structures. This study explores a new microwave ablation (MWA) approach operating at 5.8 GHz and using anatomical and dielectric characteristics of the target tissue to create directional heating patterns. Numerical simulations are executed in planar and 3D adrenal models, considering two energy doses. The numerical study is refined accounting for the vaporization of the tissue water content. Ex vivo experimental evaluations on porcine adrenal models complete the study. The numerical and experimental results show that spherical ablation zones are able to cover the target for both energy doses considered. Nonetheless, most of the non-targeted tissues can be preserved from excessive heating when low energy level is used. Numerical models accounting for water vaporization are capable to foresee the experimental temperature values. This study shows that the proposed MWA directional approach operating at 5.8 GHz can be considered for creating effective and selective ablation zones.
To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring. 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation. Images were reconstructed ± HYPR. Image quality and dose metrics were collected. 21 MWA were performed in 4 adult swine. Immediate post-procedure CECT was performed in the arterial, portal venous, and delayed phases using both routine and DECT imaging with full-dose weight-based IV contrast dosing. An additional 16 MWA were subsequently performed in 2 adult swine. Immediate post-procedure CT was performed with half-dose IV contrast using routine and DECT. 12 patients (10 M/2F, mean age 62.4 yrs) with 14 hepatic tumors (4 HCC, 10 metastatic lesions) treated with MWA were prospectively imaged with DECT 1 month post-procedure. 120 kV equivalent images were compared to DECT [51 keV, iodine material density]. Image quality and dose metrics were collected. Gas created during MWA led to high CNR in all intraprocedural CT datasets. Optimal CNRs were noted at 4 min with CNR 6.7, 15.5,15.9, and 21.5 on LD-CECT, LD-CECT + HYPR, DECT, and DECT + HYPR, respectively (p < 0.001). Image quality scores at 4 min were 1.8, 2.8, 2.4, and 3, respectively (p < 0.001). Mean radiation dose (CTDIvol) was eightfold higher for the DECT series. For swine, post-procedural DECT images (IMD/51 keV) showed improved CNR compared to routine CT at all time points with full and with reduced dose contrast (CNR 4.6, 3.2, and 1.5, respectively, at half-contrast dose, p < 0.001). For human subjects, the 51 keV and IMD images showed higher CNRs (5.8, 4.8 vs 4.0, p < 0.001) and SNRs (3.7, 5.9 vs 2.8). Ablation zone sharpness was improved with DECT (routine 3.0 ± 0.7, DECT 3.5 ± 0.5). Diagnostic confidence was higher with DECT (routine 2.3 ± 0.9, DECT 2.6 ± 0.8). Mean DLP for DECT was 905.7 ± 606 mGy-cm, CTDIvol 37.5 ± 21.2 mGy, and effective dose 13.6 ± 9.1 mSv, slightly higher than conventional CT series. Advanced CT techniques can improve CT image quality in peri-procedural hepatic microwave ablation zone evaluation.
PurposeIntra‐procedural monitoring and post‐procedural follow‐up is necessary for a successful ablation treatment. An imaging technique which can assess the ablation geometry accurately is beneficial to monitor and evaluate treatment. In this study, we developed an automated ablation segmentation technique for serial low‐dose, noisy ablation computed tomography (CT) or contrast‐enhanced CT (CECT).MethodsLow‐dose, noisy temporal CT and CECT volumes were acquired during microwave ablation on normal porcine liver (four with non‐contrast CT and eight with CECT). Highly constrained backprojection (HYPR) processing was used to recover ablation zone information compromised by low‐dose noise. First‐order statistic features and normalized fractional Brownian features (NBF) were used to segment ablation zones by fuzzy c‐mean clustering. After clustering, the segmented ablation zone was refined by cyclic morphological processing. Automatic and manual segmentations were compared to gross pathology with Dice’s coefficient (morphological similarity), while cross‐sectional dimensions were compared by percent difference.ResultsAutomatic and manual segmentations of the ablation zone were very similar to gross pathology (Dice Coefficients: Auto.‐Path. = 0.84 ± 0.02; Manu.‐Path. = 0.76 ± 0.03, P = 0.11). The differences in ablation area, major diameter and minor diameter were 17.9 ± 3.2%, 11.1 ± 3.2% and 16.2 ± 3.4%, respectively, when comparing automatic segmentation to gross pathology, which were lower than the differences of 32.9 ± 16.8%, 13.0 ± 9.8% and 21.8 ± 5.8% when comparing manual segmentation to gross pathology. Manual segmentations tended to overestimate gross pathology when ablation area was less than 15 cm2, but the automated segmentation tended to underestimate gross pathology when ablation zone is larger than 20 cm2.ConclusionFuzzy c‐means clustering may be used to aid automatic segmentation of ablation zones without prior information or user input, making serial CT/CECT has more potential to assess treatments intra‐procedurally.
OBJECTIVE To investigate the relationship between metabolic syndrome (MetS) and lower urinary tract symptoms (LUTS) with functional and anatomic changes of the lower urinary tract with MRI. MATERIALS AND METHODS The bladder and prostate of 95 subjects (56M, 39F) were segmented on T2-weighted pelvic MRI using Materialize Mimics 3D software. Bladder wall volume (BWV), post-void residual (PVR) and prostate volume (PV) were quantified from the 3D renderings. LUTS were quantified using validated questionnaires administered at the time of MRI. Wilcoxin rank sum, win ratio and chisquare tests were used to correlate symptom scores, BWV, PVR and PV in patients 1) without vs with MetS, 2) with mild (IPSS or UDI-6: 0-7) vs moderate-severe (IPSS: 8-35 or UDI-6: >= 8) and 3) normal vs enlarged prostates (>40cm(3)). Multivariate linear regression was used to determine predictors for BWV, PVR and PV. RESULTS Men with MetS had increased BWV (66.8 vs 51.1cm(3), P = .003), higher PVR (69.1 vs 50.5cc, P= .05) and increased PV (67.2 vs 40.1cm(3) , P= .01). Women without and with MetS had similar BWV, PVR and LUTS (P= .3-.78). There was no difference in prevalence of MetS, BWV, PVR or PV in men or women with mild vs moderate-severe LUTS (P = .26-.97). Men with enlarged prostates were more likely to have MetS (P = .003). There was no difference in BWV, PVR and LUTS for men with normal vs enlarged prostates (P= .44-.94). In men, BWV was highly correlated with MetS (P = .005) on regression analysis. CONCLUSION MetS leads to detrusor hypertrophy and may contribute to impaired bladder function, likely related to the effect on the prostate. (C) 2021 Elsevier Inc.
Objective: Measurements of tissue permittivity with small open-ended coaxial probes during microwave tissue heating have been plagued by high variability as tissue water becomes vaporized. Analysis of such variability has been hampered by a lack of direct visualization of the measurement volume. The objective of this study was to determine if X-ray computed tomography (CT) could be used to visualize the measurement volume and then predict dielectric permittivity based on the visualized tissue composition. Methods: CT attenuation at 120 kVp was measured at the end of an open-ended coaxial probe during microwave ablation of ex vivo liver (2.45 GHz at 50 W delivered for 5 minutes). Tissue composition was estimated from attenuation maps and used to predict dielectric properties based on established mixture equations. Predicted permittivity was then compared to measured values using error metrics and linear regression. Results: There was a good agreement between measured and modeled permittivity during 5-minute ablations at 2.45 GHz (r = 0.94, p <; .001). Normalized root mean squared errors were below 17% in permittivity modeling at 2.45 GHz. Conclusion and significance: CT-based model predictions of dielectric properties are feasible in ex vivo liver. The models may facilitate real-time imaging-based permittivity mapping.
Purpose The goal of this study was to compare intra-procedural radiofrequency (RF) and microwave ablation appearance on non-contrast CT (NCCT) and ultrasound to the zone of pathologic necrosis. Materials and methods Twenty-one 5-min ablations were performed in vivo in swine liver with (1) microwave at 140 W, (2) microwave at 70 W, or (3) RF at 200 W (n = 7 each). CT and US images were obtained simultaneously at 1, 3, and 5 min during ablation and 2, 5, and 10 min post-ablation. Each ablation was sectioned in the plane of the ultrasound image and underwent vital staining to delineate cellular necrosis. CT was reformatted to the same plane as the ultrasound transducer and transverse diameters of gas and hypoechoic/hypoattenuating zones at each time point were measured. CT, ultrasound and gross pathologic diameter measurements were compared using Student’s t-tests and linear regression. Results Visible gas and the hypoechoic zone on US images were more predictive of the pathologic ablation zone than on NCCT images (p < 0.05). The zone of necrosis was larger than the zone of visible gas on US (mean 3.2 mm for microwave, 6.4 mm for RF) and NCCT (7.6 mm microwave, 13.9 mm RF) images (p < 0.05). The zone of visible gas and hypoechoic zone on US are more predictive of pathology with microwave ablations when compared with RF ablations (p < 0.05). Conclusion When evaluating images during energy delivery, US is more accurate than CT and microwave- more predictable than RF-ablation based on correlation with in-plane pathology.
The therapeutic application of heat is very effective in cancer treatment. Both hyperthermia, i.e., heating to 39–45 °C to induce sensitization to radiotherapy and chemotherapy, and thermal ablation, where temperatures beyond 50 °C destroy tumor cells directly are frequently applied in the clinic. Achievement of an effective treatment requires high quality heating equipment, precise thermal dosimetry, and adequate quality assurance. Several types of devices, antennas and heating or power delivery systems have been proposed and developed in recent decades. These vary considerably in technique, heating depth, ability to focus, and in the size of the heating focus. Clinically used heating techniques involve electromagnetic and ultrasonic heating, hyperthermic perfusion and conductive heating. Depending on clinical objectives and available technology, thermal therapies can be subdivided into three broad categories: local, locoregional, or whole body heating. Clinically used local heating techniques include interstitial hyperthermia and ablation, high intensity focused ultrasound (HIFU), scanned focused ultrasound (SFUS), electroporation, nanoparticle heating, intraluminal heating and superficial heating. Locoregional heating techniques include phased array systems, capacitive systems and isolated perfusion. Whole body techniques focus on prevention of heat loss supplemented with energy deposition in the body, e.g., by infrared radiation. This review presents an overview of clinical hyperthermia and ablation devices used for local, locoregional, and whole body therapy. Proven and experimental clinical applications of thermal ablation and hyperthermia are listed. Methods for temperature measurement and the role of treatment planning to control treatments are discussed briefly, as well as future perspectives for heating technology for the treatment of tumors.