Purpose The objectives of this report are to compare optical coherence tomography (OCT) based retinal nerve fiber layer (RNFL) and ganglion cell / inner plexiform layer (GCIPL) thickness in participants who developed primary open-angle glaucoma (POAG) in the Ocular Hypertension Treatment Study (OHTS) to RNFL and GCIPL thickness in those who did not develop POAG (ie, a parallel control group) and to elucidate the relationship between duration after reaching an OHTS POAG endpoint and RNFL and GCIPL thickness. Design Clinical cohort study using OCT data. Methods Six hundred and forty six OHTS participants who completed OHTS 3 visit OCT imaging were included. Cirrus and Spectralis parapapillary RNFL and GCIPL thickness measurements were compared between 450 eyes that developed POAG and 723 eyes in the control group that did not develop POAG. Results In eyes that developed POAG compared to eyes that did not develop POAG, mean global RNFL thickness was between 11.1 and 12.7 µm thinner and mean global GCIPL was between 4.5 and 7.6 µm thinner using Spectralis and Cirrus OCT, respectively (all comparisons P < .001). The 10+ years after POAG diagnosis POAG eyes had ∼10% thinner mean global RNFL thickness and GCIPL thickness than eyes with shorter durations after POAG diagnosis. Conclusions In the OHTS, the ocular hypertensive eyes that developed POAG had significantly thinner RNFL and GCIPL measurements compared with the ocular hypertensive eyes that did not develop glaucoma. In addition, longer duration of POAG was associated with thinner RNFL/GCIPL independent of POAG treatment status and IOP level. These results characterize the magnitude of RNFL and GCIPL thinning associated with increasing POAG duration and reinforce the role of OCT as a key tool for monitoring glaucomatous structural change in eyes with OH.
Objective:To develop an explainable multimodal large language model (MM-LLM) that (1) screens optic nerve head (ONH) OCT circle scans for quality and (2) generates structured clinical reports that include glaucoma diagnosis and sector-wise retinal nerve fiber layer (RNFL) thinning assessments. Design:A retrospective cohort study using longitudinal data from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Participants:A total of 43 849 Spectralis circumpapillary B-scans centered on the ONH from 1310 subjects, including 1331 glaucomatous and 867 healthy eyes. Methods:An MM-LLM (Llama 3.2 Vision-Instruct model) was fine-tuned to generate clinical descriptions of OCT imaging data. Training data included paired OCT images and automatically generated, structured clinical reports that described global and sectoral RNFL thinning. Poor-quality scans were labeled as unusable and paired with a fixed refusal statement. The model was evaluated on a held-out test set for 3 tasks: quality assessment, glaucoma detection, and RNFL thinning classification across 7 anatomical sectors. Evaluation metrics included accuracy, sensitivity, specificity, precision, and F1-score. Model description quality was also evaluated using standard text evaluation metrics (BLEU, ROUGE, METEOR, and BERTScore). Main Outcome Measures:Diagnostic accuracy metrics for each task; text evaluation metrics for description quality. Results:The model achieved 0.90 accuracy and 0.98 specificity for quality triage. For glaucoma detection, accuracy was 0.86 (sensitivity 0.93, specificity 0.65, and F1-score 0.91). Retinal nerve fiber layer thinning prediction accuracy ranged from 0.83 to 0.94, with the highest performance in global, temporal, temporal superior, and temporal inferior sectors. Text generation scores (mean ± standard deviation) showed strong alignment with reference reports (BLEU: 0.82 ± 0.19; ROUGE-1: 0.94 ± 0.08; ROUGE-2: 0.87 ± 0.17; ROUGE-L: 0.92 ± 0.11; BERTScore-F1: 0.99 ± 0.02). Stratified analysis revealed better RNFL thinning detection in moderate-to-advanced glaucoma cases, especially in temporal sectors, while performance in nasal regions was better for mild cases. Conclusions:The fine-tuned MM-LLM generated accurate clinical descriptions based on OCT imaging. The model achieved high accuracy in identifying image quality issues and detecting glaucoma. The model provided sectoral descriptions of RNFL thinning to support clinical OCT evaluation. This approach shows potential as a scalable tool for clinical decision support, but further validation across additional datasets is needed. Financial Disclosures:Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Large language models (LLMs) show promise in medical image interpretation but suffer from hallucination, limited accuracy, and run-to-run inconsistency. We developed and validated an agentic AI framework integrating LLMs with specialized deep learning tools for glaucoma detection from fundus photography. The workflow had three steps: (1) LLM initial assessment; (2) function calling to invoke specialized tools for image quality (QAModel, FundaQ-8), glaucoma classification (SwinV2-Tiny), and optic disc/cup segmentation (SegFormer-B0); and (3) LLM reflection integrating the initial impression with tool outputs. Two LLMs (Gemini 2.5 Flash, GPT-5.4 mini) were evaluated on two public datasets (ORIGA, n=100; RIM-ONE-v3, n=100) under uncropped and cropped fields of view; all images were independently graded by a masked fellowship-trained glaucoma specialist. The agentic workflow improved classification accuracy by 16 to 47 percentage points across all conditions, reaching within 6 points of the specialist; on RIM-ONE-v3 the best configurations matched the specialist accuracy of 88
Purpose:To evaluate the accuracy of a three-dimensional (3D) deep learning (3D DL) and 3D cross domain deep learning (3D CD-DL) classifiers compared to standard macular ganglion cell-inner plexiform layer (GCIPL) thickness measurements for classifying eyes with glaucoma using optical coherence tomography (OCT). Methods:A total of 502 primary open-angle glaucoma eyes from 295 patients and 119 healthy eyes from 63 individuals were included. Two classifiers were compared: (1) a 3D DL model trained on Spectralis macular OCT and applied to Spectralis macular OCT images and (2) 3D CD-DL model trained on synthetic Spectralis images generated from 3D Cirrus macular OCT using Cycle-consistent adversarial networks (CycleGAN) and applied to real Spectralis macula OCT images. An additional 100 different eyes (50 Cirrus, 50 Spectralis) were used to train the CycleGAN. Age, axial length, and disc area adjusted area under the receiver operating curves (AUROC) were used to compare model accuracy. Results:Adjusted AUROC for 3D DL model was 0.92 (95% confidence interval [CI], 0.85-0.95). This was significantly higher than global GCIPL thickness (0.83 [0.78-0.85], p ≤ 0.001) but similar to 3D CD-DL (0.91 [0.84-0.95], P = 0.45). Using only early glaucoma eyes (mean deviation ≥ -3.0 dB), the 3D DL model showed significantly higher diagnostic accuracy (0.90 [0.84-0.94]) compared to global GCIPL thickness (0.80 [0.76-0.82], P ≤ 0.001) but similar to the 3D CD-DL model (0.90 [0.83-0.93], P = 0.51). Conclusions:The 3D DL classifier showed significantly higher diagnostic accuracy than global GCIPL thickness but was similar in performance to the 3D CD-DL classifier. By using synthetic data and diverse training sets, cross-domain learning produces robust, generalizable models across different imaging devices as demonstrated by the comparable accuracy of the 3D CD-DL and device-specific 3D DL models. More data from other OCT devices are needed to further validate these findings. Translational Relevance:The 3D Deep learning models significantly surpass traditional GCIPL thickness measurements for accurately detecting glaucoma. The cross-domain model closely matches the performance of the device-specific model in glaucoma classification potentially reducing the need for device-specific models in clinical practice.
Objective:To develop an explainable multimodal large language model (MM-LLM) that (1) screens optic nerve head (ONH) OCT circle scans for quality and (2) generates structured clinical reports that include glaucoma diagnosis and sector-wise retinal nerve fiber layer (RNFL) thinning assessments. Design:Retrospective cohort study using longitudinal data from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES). Participants:43,849 Spectralis ONH OCT circle scans from 1,310 subjects, including 1,331 glaucomatous and 867 healthy eyes. Methods:A MM-LLM (Llama 3.2 Vision-Instruct model) was fine-tuned to generate clinical descriptions of OCT imaging data. Training data included paired OCT images and automatically generated, structured clinical reports that described global and sectoral RNFL thinning. Poor-quality scans were labeled as unusable and paired with a fixed refusal statement. The model was evaluated on a held-out test set for three tasks: quality assessment, glaucoma detection, and RNFL thinning classification across seven anatomical sectors. Evaluation metrics included accuracy, sensitivity, specificity, precision, and F1-score. Model description quality was also evaluated using standard text evaluation metrics (BLEU, ROUGE, METEOR, BERTScore). Results:The model achieved 0.90 accuracy and 0.98 specificity for quality triage. For glaucoma detection, accuracy was 0.86 (sensitivity 0.91, specificity 0.73, F1-score 0.91). RNFL thinning prediction accuracy ranged from 0.83 to 0.94, with highest performance in global and temporal sectors. Text generation scores (mean ± SD) showed strong alignment with reference reports (BLEU: 0.82 ± 0.19; ROUGE-1: 0.94 ± 0.08; ROUGE-2: 0.87 ± 0.17; ROUGE-L: 0.92 ± 0.11; BERTScore-F1: 0.99 ± 0.02). Stratified analysis revealed better RNFL thinning detection in moderate-to-advanced glaucoma cases, especially in temporal sectors, while performance in nasal regions was better for mild cases. Conclusions:The fine-tuned MM-LLM generated accurate clinical descriptions based on OCT imaging. The model achieved high accuracy in identifying image quality issues and detecting glaucoma. The model also provided sectoral descriptions of RNFL thinning to help support clinical OCT evaluation. This approach shows potential as a scalable tool for clinical decision support, but further validation across additional datasets is needed.
Purpose: The aim is to assess GPT-4V's (OpenAI) diagnostic accuracy and its capability to identify glaucoma-related features compared to expert evaluations. Design: Evaluation of multimodal large language models for reviewing fundus images in glaucoma. Subjects: A total of 300 fundus images from 3 public datasets (ACRIMA, ORIGA, and RIM-One v3) that included 139 glaucomatous and 161 nonglaucomatous cases were analyzed. Methods: Preprocessing ensured each image was centered on the optic disc. GPT-4's vision-preview model (GPT-4V) assessed each image for various glaucoma-related criteria: image quality, image gradability, cup-to-disc ratio, peripapillary atrophy, disc hemorrhages, rim thinning (by quadrant and clock hour), glaucoma status, and estimated probability of glaucoma. Each image was analyzed twice by GPT-4V to evaluate consistency in its predictions. Two expert graders independently evaluated the same images using identical criteria. Comparisons between GPT-4V's assessments, expert evaluations, and dataset labels were made to determine accuracy, sensitivity, specificity, and Cohen kappa. Main Outcome Measures: The main parameters measured were the accuracy, sensitivity, specificity, and Cohen kappa of GPT-4V in detecting glaucoma compared with expert evaluations. Results: GPT-4V successfully provided glaucoma assessments for all 300 fundus images across the datasets, although approximately 35% required multiple prompt submissions. GPT-4V's overall accuracy in glaucoma detection was slightly lower (0.68, 0.70, and 0.81, respectively) than that of expert graders (0.78, 0.80, and 0.88, for expert grader 1 and 0.72, 0.78, and 0.87, for expert grader 2, respectively), across the ACRIMA, ORIGA, and RIM-ONE datasets. In Glaucoma detection, GPT-4V showed variable agreement by dataset and expert graders, with Cohen kappa values ranging from 0.08 to 0.72. In terms of feature detection, GPT-4V demonstrated high consistency (repeatability) in image gradability, with an agreement accuracy of ≥89% and substantial agreement in rim thinning and cup-to-disc ratio assessments, although kappas were generally lower than expert-to-expert agreement. Conclusions: GPT-4V shows promise as a tool in glaucoma screening and detection through fundus image analysis, demonstrating generally high agreement with expert evaluations of key diagnostic features, although agreement did vary substantially across datasets. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
PurposeTo evaluate the diagnostic accuracy of a deep learning autoencoder-based model utilizing regions of interest (ROI) from optical coherence tomography (OCT) texture enface images for detecting glaucoma in myopic eyes.MethodsThis cross-sectional study included a total of 453 eyes from 315 participants from the multi-center "Swept-Source OCT (SS-OCT) Myopia and Glaucoma Study", composed of 268 eyes from 168 healthy individuals and 185 eyes from 147 glaucomatous individuals. All participants underwent swept-source optical coherence tomography (SS-OCT) imaging, from which texture enface images were constructed and analyzed. The study compared four methods: (1) global RNFL thickness, (2) texture enface image, (3) a single autoencoder model trained only on healthy eyes, and (4) a dual autoencoder model trained on both healthy and glaucomatous eyes. Diagnostic accuracy was assessed using the area under the receiver operating curves (AUROC) and precision recall curves (AUPRC).ResultsThe dual autoencoder model achieved the highest AUROC (95% CI) (0.92 [0.88, 0.95]), significantly outperforming the single autoencoder model trained only on healthy eyes (0.86 [0.83, 0.88], p = 0.01), the global RNFL thickness model (0.84 [0.80, 0.86], p = 0.003), and the texture enface model (0.83 [0.79, 0.85], p = 0.005). Using AUPRC (95% CI), the dual autoencoder model (0.86 [0.83, 0.89]) also outperformed the single autoencoder model trained only on healthy eyes (0.80 [0.78, 0.82], p = 0.02), the global RNFL thickness model (0.74 [0.70, 0.76], p = 0.001), and the texture enface model (0.71 [0.68, 0.73], p<0.001). No significant difference was observed between the global RNFL thickness measurement and the texture enface measurement (p = 0.47).DiscussionThe dual autoencoder model, which integrates reconstruction errors from both healthy and glaucomatous training data, demonstrated superior diagnostic accuracy compared to the single autoencoder model, global RNFL thickness and texture enface-based approaches. These findings suggest that deep learning models leveraging ROI-based reconstruction error from texture enface images may enhance glaucoma classification in myopic eyes, providing a robust alternative to conventional structural thickness metrics.
Purpose:To compare the performance of unimodal and multimodal implementation of the self-supervised learning model RETFound in detecting glaucoma using color fundus photographs (CFPs) and OCT images, and to assess its generalizability across different ethnicities, age groups, and disease severities. Design:Evaluation of a diagnostic technology. Subjects Participants and Controls:Fourteen thousand five hundred ten CFPs and 32 640 OCTs from 1948 eyes of 1098 participants (60.8% glaucoma, 39.2% healthy) from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study were included. Glaucoma was defined as photograph-based glaucomatous optic neuropathy with or without repeatable glaucoma visual field damage. Methods:A multimodal RETFound model was developed using paired CFPs and OCT images. The model was compared to unimodal RETFound models using solely CFP or OCT images. Performance was also stratified by race (Black vs. White), age (<60 vs. ≥60 years), and disease severity (mild vs. moderate-to-severe glaucoma). Main Outcome Measures:Diagnostic accuracy of unimodal and multimodal RETFound models using CFP and OCT for detecting glaucoma was assessed using the area under the receiver operating characteristic curve (AUC), precision, and recall. Results:The multimodal model for glaucoma detection achieved an AUC of 0.94 (95% confidence interval: 0.91-0.97), significantly outperforming the CFP unimodal model (AUC 0.86 [95% confidence interval: 0.81-0.89], P < 0.001) but not the OCT unimodal model (AUC 0.93 [95% confidence interval: 0.90-0.96], P = 0.47). Precision and recall were higher (0.96 and 0.87, respectively) for the multimodal model compared with the CFP model (0.92 and 0.69) across all subgroups. No significant differences based on race or age were found in either unimodal or multimodal glaucoma detection models. All models exhibited better performance in detecting moderate-to-severe glaucoma than mild glaucoma, with significant differences in the unimodal CFP (P = 0.002) and OCT (P = 0.005) models. Conclusions:The multimodal RETFound model demonstrated improved diagnostic ability compared with the CFP unimodal model but did not significantly outperform the OCT unimodal model in glaucoma detection. As clinical implementation of a unimodal artificial intelligence (AI) model is easier than a multimodal counterpart, our results suggest unimodal OCT AI models may be sufficient for detecting glaucoma. Financial Disclosures:Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
This study aims to develop deep learning (DL) models to predict the retinal nerve fiber layer (RNFL) thickness changes in glaucoma, facilitating the early diagnosis and monitoring of disease progression. Using the longitudinal data from two glaucoma studies (Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES)), we constructed models using optical coherence tomography (OCT) scans from 251 participants (437 eyes). The models were trained to predict the RNFL thickness at a future visit based on previous scans. We evaluated four models: linear regression (LR), support vector regression (SVR), gradient boosting regression (GBR), and a custom 1D convolutional neural network (CNN). The GBR model achieved the best performance in predicting pointwise RNFL thickness changes (MAE = 5.2 μm, R2 = 0.91), while the custom 1D CNN excelled in predicting changes to average global and sectoral RNFL thickness, providing greater resolution and outperforming the traditional models (MAEs from 2.0–4.2 μm, R2 from 0.94–0.98). Our custom models used a novel approach that incorporated longitudinal OCT imaging to achieve consistent performance across different demographics and disease severities, offering potential clinical decision support for glaucoma diagnosis. Patient-level data splitting enhances the evaluation robustness, while predicting detailed RNFL thickness provides a comprehensive understanding of the structural changes over time.
Purpose To compare the performance of unimodal and multimodal implementation of the self-supervised learning model RETFound in detecting glaucoma using color fundus photographs (CFP) and optical coherence tomography (OCT) images, and to assess its generalizability across different ethnicities, age groups, and disease severities. Design Evaluation of a diagnostic technology Subjects, Participants, and Controls 14,510 CFPs and 32,640 OCTs from 1,948 eyes of 1,098 participants (60.8% glaucoma, 39.2% healthy) from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES) were included. Glaucoma was defined as photograph-based glaucomatous optic neuropathy (GON) with or without repeatable glaucoma visual field damage (GVFD). Methods A multimodal RETFound model was developed using paired CFPs and OCT images. The model was compared to unimodal RETFound models using solely CFP or OCT images. Performance was also stratified by race (Black vs. White), age (<60 vs. ≥60 years), and disease severity (mild vs. moderate-to-severe glaucoma). Main Outcome Measures Diagnostic accuracy of unimodal and multimodal RETFound models using CFP and OCT for detecting glaucoma was assessed using the area under the receiver operating characteristic curve (AUC), precision, and recall. Results The multimodal model for glaucoma detection achieved an AUC of 0.94 (95% CI: 0.91–0.97), significantly outperforming the CFP unimodal model (AUC 0.86 [95% CI: 0.81–0.89], p < 0.001) but not the OCT unimodal model (AUC 0.93 [95% CI: 0.90–0.96], p = 0.47). Precision and recall were higher (0.96 and 0.87, respectively) for the multimodal model compared to the CFP model (0.92 and 0.69) across all subgroups. No significant differences based on race or age were found in either unimodal or multimodal glaucoma detection models. All models exhibited better performance in detecting moderate-to-severe glaucoma than mild glaucoma, with significant differences in the unimodal CFP (p = 0.002) and OCT (p = 0.005) models. Conclusions The multimodal RETFound model demonstrated improved diagnostic ability compared to the CFP unimodal model but did not significantly outperform the OCT unimodal model in glaucoma detection. As real-world clinical implementation of a unimodal AI model is easier than a multimodal counterpart, our results suggest unimodal OCT AI models may be sufficient for detecting glaucoma.
Purpose:To evaluate the performance of vision-language models (VLMs), in glaucoma detection and visual field (VF) mean deviation (MD) prediction tasks using optical coherence tomography (OCT) images. Methods:A total of 27,610 SPECTRALIS OCT images from 1025 participants (1690 eyes), collected between 2008 and 2021 as part of the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES), were included. Vision components of LLaVA and PaliGemma, as well as RETFound and ResNet-50 models, were fine-tuned for glaucoma classification and VF MD prediction. Models were trained using OCT circle scans centered on the optic nerve head. Three training configurations were compared. Performance was evaluated using area under the receiver operating characteristic curve (AUC), mean absolute error (MAE), and related metrics. Results:The LLaVA model, when both vision encoder and multi-layer projector were fine-tuned, achieved the best performance with an AUC of 0.92 (95% confidence interval [CI], 0.86-0.95) for glaucoma classification and an MAE of 1.79 dB (95% CI, 1.55-2.00) for VF MD prediction. RETFound and PaliGemma also performed well, with AUCs of 0.91 and 0.90 and MAEs of 1.87 dB and 1.84 dB, respectively. Models with frozen vision encoders showed reduced accuracy. Stratified analysis showed better glaucoma classification in older individuals and moderate-to-advanced cases. VF MD prediction was more accurate in younger individuals, with higher errors in advanced glaucoma. Conclusions:Fine-tuned VLMs demonstrated high performance in glaucoma detection and VF MD prediction, matching or exceeding specialized foundation models and traditional convolutional neural network (CNN)-based methods. Translational Relevance:This study highlights the potential of general-purpose AI models to be adapted for glaucoma care, enabling scalable decision support from OCT imaging.
Purpose:To develop and evaluate a deep learning (DL) model to assess fundus photograph quality, and quantitatively measure its impact on automated POAG detection in independent study populations. Methods:Image quality ground truth was determined by manual review of 2815 fundus photographs of healthy and POAG eyes from the Diagnostic Innovations in Glaucoma Study and African Descent and Glaucoma Evaluation Study (DIGS/ADAGES), as well as 11,350 from the Ocular Hypertension Treatment Study (OHTS). Human experts assessed a photograph as high quality if of sufficient quality to determine POAG status and poor quality if not. A DL quality model was trained on photographs from DIGS/ADAGES and tested on OHTS. The effect of DL quality assessment on DL POAG detection was measured using area under the receiver operating characteristic (AUROC). Results:The DL quality model yielded an AUROC of 0.97 for differentiating between high- and low-quality photographs; qualitative human review affirmed high model performance. Diagnostic accuracy of the DL POAG model was significantly greater (P < 0.001) in good (AUROC, 0.87; 95% CI, 0.80-0.92) compared with poor quality photographs (AUROC, 0.77; 95% CI, 0.67-0.88). Conclusions:The DL quality model was able to accurately assess fundus photograph quality. Using automated quality assessment to filter out low-quality photographs increased the accuracy of a DL POAG detection model. Translational Relevance:Incorporating DL quality assessment into automated review of fundus photographs can help to decrease the burden of manual review and improve accuracy for automated DL POAG detection.
PurposeTo evaluate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) by spectral-domain optical coherence tomography (OCT) in primary open-angle glaucoma (POAG) in eyes of African (AD) and European descent (ED).DesignComparative diagnostic accuracy analysis by race.Participants379 healthy eyes (125 AD and 254 ED) and 442 glaucomatous eyes (226 AD and 216 ED) from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study.MethodsSpectralis (Heidelberg Engineering GmbH) and Cirrus (Carl Zeiss Meditec) OCT scans were taken within one year from each other.Main Outcome MeasuresDiagnostic accuracy of RNFLT measurements.ResultsDiagnostic accuracy for Spectralis-RNFLT was significantly lower in eyes of AD compared to those of ED (area under the receiver operating curve [AUROC]: 0.85 and 0.91, respectively, P=0.04). Results for Cirrus-RNFLT were similar but did not reach statistical significance (AUROC: 0.86 and 0.90 in AD and ED, respectively, P =0.33). Adjustments for age, central corneal thickness, axial length, disc area, visual field mean deviation, and intraocular pressure yielded similar results.ConclusionsOCT-RNFLT has lower diagnostic accuracy in eyes of AD compared to those of ED. This finding was generally robust across two OCT instruments and remained after adjustment for many potential confounders. Further studies are needed to explore the potential sources of this difference.
Purpose:To compare rates of retinal nerve fiber layer change over time in healthy, eyes with nonprogressing glaucoma and eyes with progressing glaucoma using single wide-field (SWF) and optic nerve head (ONH) cube scan optical coherence tomography (OCT) images. Methods:Forty-five eyes of 25 healthy individuals and 263 eyes of 161 glaucoma patients from the Diagnostic Innovations in Glaucoma Study were included. All eyes underwent 24-2 visual field testing and OCT (Spectralis SD-OCT) ONH and macular imaging. SWF images (up to 43° × 28°) were created by stitching together ONH cube scans centered on the optic disc and macular cube scans centered on the fovea. Visual field progression was defined as guided progression analysis likely progression and/or a significant (P < 0.01) mean deviation slope of less than -1.0 dB/year. Mixed effects models were used to compare rates of change. Highly myopic eyes were included. Results:Thirty glaucomatous eyes were classified as progressing. In eyes with glaucoma, mean global rate of change was -1.22 µm/year (P < 0.001) using SWF images and -0.83 µm/year (P = 0.003) using ONH cube scans. Rate of change was significantly greater in eyes with progressing glaucoma compared with eyes with nonprogressing glaucoma (-1.51 µm/year vs. -1.24 µm/year; P = 0.002) using SWF images and was similar using ONH cube scans (P = 0.27). Conclusions:In this cohort that includes eyes with and without high axial myopia, the mean rate of retinal nerve fiber layer thinning measured using SWF images was faster in eyes with progressing glaucoma than in eyes with nonprogressing glaucoma. Wide-field OCT images including the ONH and macula can be effective for monitoring glaucomatous progression in patients with and without high myopia.