This paper presents a novel approach using multiple linear regression to process transient signals from silicon photomultipliers. The method provides excellent noise suppression and pulse detection in scenarios with a high pulse count rate and superimposed pulses. Insights into its implementation and benchmark results are presented. We also show how this approach can be used to automatically detect the pulse shape from a given transient signal, providing good detection for count rates up to 90MHz. Experimental data are used to present an application where this algorithm improves charge spectrum resolution by an order of magnitude.
In this paper we present the performance of a new SiPM that is sensitive to blue light and features narrow metal-filled trenches placed in the area around the single-photon avalanche diodes (SPADs) that allow an almost complete suppression the internal optical crosstalk. In particular, we show the benefits of this technological upgrade in terms of electro-optical SiPM performance when compared to the previous technology which had only a partial optical screening between the SPADs. The most relevant effect is the much higher bias voltage that can be applied to the new device before the noise diverges. This allows to optimize and improve both the photon detection efficiency and the single-photon time resolution. We also coupled the SiPMs to LYSO scintillators to verify the performance for possible application in Positron-Emission Tomography. Thanks to the better electro-optical features we were able to measure an improved coincidence time resolution. Furthermore, the optimal voltage operation region is substantially larger, making this SiPM more suitable for real system application where thousands of channels have to provide stable and reproducible performance.
The enhanced x-ray timing and polarimetry mission (eXTP) is a flagship observatory for x-ray timing, spectroscopy and polarimetry developed by an international consortium. Thanks to its very large collecting area, good spectral resolution and unprecedented polarimetry capabilities, eXTP will explore the properties of matter and the propagation of light in the most extreme conditions found in the universe. eXTP will, in addition, be a powerful x-ray observatory. The mission will continuously monitor the x-ray sky, and will enable multi-wavelength and multi-messenger studies. The mission is currently in phase B, which will be completed in the middle of 2022.
We present photon detection efficiency (PDE) measurements of three different silicon photomultipliers (SiPM) and report the temperature coefficient of this parameter using a direct measurement method. This study provides first results in such a wide temperature and wavelength range, from -30°C to 70°C and from 365 nm to 900 nm respectively. To carry out this study we developed a setup providing stable illumination of the device under test in temperature. The PDE is evaluated using a photon-counting method and the wavelength-dependent PDE temperature coefficients of all devices are determined. The different designs are compared and the individual contributors to the temperature dependence of the PDE are discussed. The PDE is shown to be linearly dependent on temperature for all designs and the temperature coefficient depends on wavelength and bias voltage. At shorter wavelengths, the temperature dependency approaches values close to zero for one design whereas all devices show increasing temperature coefficients for increasing wavelengths. This study shows that despite the more complex designs of SiPMs, compared to silicon photodiodes, similar factors contribute to the temperature dependence of the PDE.
High-performance optical power converters (OPCs) enable isolated electrical power and power beaming applications at new wavelengths and higher output powers. Broadcom’s vertical epitaxial heterostructure architecture (VEHSA) multi-junction OPCs permit optical-to-electrical conversion at high efficiency and at manageable external loads. This study provides details of how the power outputs have been extended from <1 W to a power class at ~3 W and another class at >20 W. The work also provides details of how the spectral range options have been extended from 800–830 nm to other key laser diode wavelengths such as 960–990 nm and 1500–1600 nm.
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, ^39Ar, a β emitter of cosmogenic origin. For large detectors, the atmospheric ^39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of ^39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of ^39Ar with respect to AAr by a factor larger than 1400. Assessing the ^39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly γ-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam where lepton production can be monitored at single particle level. For this purpose, the decay tunnel is instrumented with longitudinally segmented calorimeters. Three different specialized calorimeters have been designed and tested, two of which based on the shashlik calorimetric concept with a compact readout while the third is a less compact version with a lateral readout. All of the prototypes are composed of thick steel absorbers coupled to plastic scintillators. Regarding the shashlik modules, a matrix of 3 x 3 fibers runs transversely with a density of one fiber/cm(2). The fibers are coupled individually to silicon photomultipliers mounted on a custom PCB allowing to reduce the dead zones between adjacent modules to an extremely small level compared to the "fiber bundling" configurations. This setup allows a very effective longitudinal segmentation and hence e/pi separation. The second shashlik module is based on polysiloxane scintillators which come in liquid form, are poured around the fiber arrays and finally made solid with a thermal treatment. Finally, the lateral readout module, light is collected from both sides of each scintillator tile and the 10 fibers from the same UCM are bundled to a single SiPM. Here are discussed the results of test beams performed in 2016-2018 at the CERN-PS East Area and the characterization of SiPMs of different cell size (12 mu m and 15 mu m) before and after being exposed to neutron fluxes up to 10(12)/cm(2) at the INFN-LNL CN accelerator facility.
We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a similar to 6x6x45 cm(3) (13 x(0) depth) prototype. A Wavelength Shifting fiber array of 36 elements runs perpendicularly to the stack of iron (15 mm) and polysiloxane scintillator (15 mm) tiles with a density of about one over cm(2). Unlike shashlik calorimeters based on plastic organic scintillators, here fibers are optically matched with the scintillator without any intermediate air gap. The prototype features a compact light readout based on Silicon Photo-Multipliers embedded in the bulk of the detector. The detector was tested with electrons, pions and muons with energies ranging from 1 to 7 GeV at the CERN-PS. This solution offers a highly radiation hard detector to instrument the decay region of a neutrino beam, providing an event-by-event measurement of high-angle decay products associated with neutrino production (ENUBET, Enhanced NeUtrino BEams from kaon Tagging, ERC project). The results in terms of light yield, uniformity and energy resolution, are compared to a similar calorimeter built with ordinary plastic scintillators.
In this paper, we give an overview of the main properties and technological implementation of densely packed Single-photon Avalanche Diode arrays, which are commonly known as Silicon Photomultipliers, or SiPMs. These detectors feature high internal gain, single-photon sensitivity, a high Photon Detection Efficiency, proportional response to weak and fast light flashes, excellent timing resolution, low bias voltage, ruggedness and insensitivity to magnetic field. They compare favorably to the traditional Photomultiplier Tube in several applications. In this overview paper, we go through the SPAD/SiPM theory of operation, the modern SiPM implementations and the typical technological options to build the sensor. This is done in conjunction with the description of the main SiPM parameters, such as the Photon Detection Efficiency, the electrical properties, the primary and correlated noise sources and the Single Photon Time Resolution.
We summarize in this paper the detector R&D performed in the framework of the ERC ENUBET Project. We discuss in particular the latest results on longitudinally segmented shashlik calorimeters and the first HEP application of polysiloxane-based scintillators.
Different applications require different customizations of silicon photomultiplier (SiPM) technology. We present a review on the latest SiPM technologies developed at Fondazione Bruno Kessler (FBK, Trento), characterized by a peak detection efficiency in the near-UV and customized according to the needs of different applications. Original near-UV sensitive, high-density SiPMs (NUV-HD), optimized for Positron Emission Tomography (PET) application, feature peak photon detection efficiency (PDE) of 63% at 420 nm with a 35 um cell size and a dark count rate (DCR) of 100 kHz/mm2. Correlated noise probability is around 25% at a PDE of 50% at 420 nm. It provides a coincidence resolving time (CRT) of 100 ps FWHM (full width at half maximum) in the detection of 511 keV photons, when used for the readout of LYSO(Ce) scintillator (Cerium-doped lutetium-yttrium oxyorthosilicate) and down to 75 ps FWHM with LSO(Ce:Ca) scintillator (Cerium and Calcium-doped lutetium oxyorthosilicate). Starting from this technology, we developed three variants, optimized according to different sets of specifications. NUV-HD–LowCT features a 60% reduction of direct crosstalk probability, for applications such as Cherenkov telescope array (CTA). NUV-HD–Cryo was optimized for cryogenic operation and for large photosensitive areas. The reference application, in this case, is the readout of liquid, noble-gases scintillators, such as liquid Argon. Measurements at 77 K showed a remarkably low value of the DCR of a few mHz/mm2. Finally, vacuum-UV (VUV)-HD features an increased sensitivity to VUV light, aiming at direct detection of photons below 200 nm. PDE in excess of 20% at 175 nm was measured in liquid Xenon. In the paper, we discuss the specifications on the SiPM related to different types of applications, the SiPM design challenges and process optimizations, and the results from the experimental characterization of the different, NUV-sensitive technologies developed at FBK.
Shashlik calorimeters equipped with a compact readout based on Silicon PhotoMultipliers can be longitudinally segmented by directly coupling the WLS fibers with the photosensors thus embedding the readout in the bulk of the calorimeter. Results on energy resolution and particle identification for such calorimeters are presented. The SiPMs for the readout have also been characterized after being exposed to neutron fluences up to 2×1011 n/cm2 (1 MeV eq.). Alternative options for the active material were also investigated; we studied in particular polysiloxane as a substitute for plastic scintillator.
Silicon Photomultipliers with cell-pitch ranging from 12 μm to 20 μm were tested against neutron irradiation at moderate fluences to study their performance for calorimetric applications. The photosensors were developed by FBK employing the RGB-HD technology. We performed irradiation tests up to 2 × 1011 n/cm2 (1 MeV eq.) at the INFN-LNL Irradiation Test facility. The SiPMs were characterized on-site (dark current and photoelectron response) during and after irradiations at different fluences. The irradiated SiPMs were installed in the ENUBET compact calorimetric modules and characterized with muons and electrons at the CERN East Area facility. The tests demonstrate that both the electromagnetic response and the sensitivity to minimum ionizing particles are retained after irradiation. Gain compensation can be achieved increasing the bias voltage well within the operation range of the SiPMs. The sensitivity to single photoelectrons is lost at ∼ 1010 n/cm2 due to the increase of the dark current.
The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam where lepton production can be monitored at single particle level in an instrumented decay tunnel. This would allow to measure $\nu_{\mu}$ and $\nu_{e}$ cross sections with a precision improved by about one order of magnitude compared to present results. In this proceeding we describe a first realistic design of the hadron beamline based on a dipole coupled to a pair of quadrupole triplets along with the optimisation guidelines and the results of a simulation based on G4beamline. A static focusing design, though less efficient than a horn-based solution, results several times more efficient than originally expected. It works with slow proton extractions reducing drastically pile-up effects in the decay tunnel and it paves the way towards a time-tagged neutrino beam. On the other hand a horn-based transferline would ensure higher yields at the tunnel entrance. The first studies conducted at CERN to implement the synchronization between a few ms proton extraction and a horn pulse of 2-10 ms are also described.
The narrow band beam of ENUBET is the first implementation of the "monitored neutrino beam" technique proposed in 2015. ENUBET has been designed to monitor lepton production in the decay tunnel of neutrino beams and to provide a 1% measurement of the neutrino flux at source. In particular, the three body semi-leptonic decay of kaons monitored by large angle positron production offers a fully controlled $\nu_{e}$ source at the GeV scale for a new generation of short baseline experiments. In this contribution the performances of the positron tagger prototypes tested at CERN beamlines in 2016-2018 are presented.
The current generation of short baseline neutrino experiments is approaching intrinsic source limitations in the knowledge of flux, initial neutrino energy and flavor. A dedicated facility based on conventional accelerator techniques and existing infrastructures designed to overcome these impediments would have a remarkable impact on the entire field of neutrino oscillation physics. It would improve by about one order of magnitude the precision on $\nu_\mu$ and $\nu_e$ cross sections, enable the study of electroweak nuclear physics at the GeV scale with unprecedented resolution and advance searches for physics beyond the three-neutrino paradigm. In turn, these results would enhance the physics reach of the next generation long baseline experiments (DUNE and Hyper-Kamiokande) on CP violation and their sensitivity to new physics. In this document, we present the physics case and technology challenge of high precision neutrino beams based on the results achieved by the ENUBET Collaboration in 2016-2018. We also set the R&D milestones to enable the construction and running of this new generation of experiments well before the start of the DUNE and Hyper-Kamiokande data taking. We discuss the implementation of this new facility at three different level of complexity: $\nu_\mu$ narrow band beams, $\nu_e$ monitored beams and tagged neutrino beams. We also consider a site specific implementation based on the CERN-SPS proton driver providing a fully controlled neutrino source to the ProtoDUNE detectors at CERN.
ENUBET has been designed to monitor lepton production in the decay tunnel of neutrino beams at single particle level and to provide a 1% measurement of the neutrino flux at source. In particular, the three body semileptonic decay of kaons monitored by large angle positron production offers a fully controlled $\nu_e$ source at the GeV scale for a new generation of short baseline experiments. The ENUBET Collaboration presented at ICHEP the first end-to-end simulation of the beamline and a review of the performance of this non-conventional technique. Special emphasis has been given to the new static focusing system that was validated in 2018. We also discussed the performance of the positron tagger tested at CERN in 2017-2018 and the expected sensitivity of ENUBET for $\nu_e$ and $\nu_\mu$ events.
Abstract The scintillator bismuth germanate (BGO) has attractive properties for positron emission tomography (PET) systems such as high stopping power, high photo-fraction, and relatively low cost. However, its moderate scintillation light yield and slow rise and decay time compared to lutetium (yttrium) oxyorthosilicate (L(Y)SO) results in a degradation of coincidence timing resolution when scintillation photons are used for timing. Recently, it has been reported that the coincidence timing resolution of BGO can be improved by detecting Cerenkov photons, while scintillation photons still provide energy information. However, the measured coincidence timing spectrum showed much longer tails compared to the single Gaussian distribution. Because of this, TOF PET detectors based on BGO will perform worse than the full width at half maximum (FWHM) of the distribution, which is the most common metric for timing resolution, would suggest. From simulation studies, during the first few picoseconds, BGO generates ~16 Cerenkov photons per photoelectric interaction, following a 511 keV gamma ray interaction, while the probability of producing a scintillation photon during the first few picoseconds is very small. Therefore, when we configure a BGO crystal with dual-ended readout, the first arriving photons among the two opposing SiPMs are most likely Cerenkov photons, and by selecting the appropriate SiPM, an improvement in coincidence timing resolution can be achieved. In this study, both ends of a 3 × 3 × 20 mm3 BGO crystal were coupled to NUV-HD SiPMs. Trigger time differences from the dual-ended readout of BGO were widely distributed due to detecting a mixture of prompt Cerenkov and scintillation photons on both SiPMs. When using trigger times from only a single SiPM, the estimated coincidence timing resolution between two identical BGO detectors was 463 ps FWHM and 1463 ps FWTM. In contrast, when using trigger times from both SiPMs, the estimated coincidence timing resolution was 399 ps FWHM and 936 ps FWTM with no loss of events. Based on a recent report, high-bandwidth amplifiers were implemented and shown to further improve the estimated coincidence timing resolution to 331 ps FWHM and 923 ps FWTM. In summary, the coincidence timing resolution of BGO, most notably the FWTM, was significantly improved using time information from the dual-ended readout.
In this paper we present the enhanced X-ray Timing and Polarimetry mission—eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.