The investigation of neurophysiological mechanisms underlying the functional specificity of brain regions requires the development of technologies that are well adjusted to in vivo studies in small animals. An exciting challenge remains the combination of brain imaging and behavioural studies, which associates molecular processes of neuronal communications to their related actions. A pixelated intracerebral probe (PIXSIC) presents a novel strategy using a submillimetric probe for beta(+) radiotracer detection based on a pixelated silicon diode that can be stereotaxically implanted in the brain region of interest. This fully autonomous detection system permits time-resolved high sensitivity measurements of radiotracers with additional imaging features in freely moving rats. An application-specific integrated circuit (ASIC) allows for parallel signal processing of each pixel and enables the wireless operation. All components of the detector were tested and characterized. The beta(+) sensitivity of the system was determined with the probe dipped into radiotracer solutions. Monte Carlo simulations served to validate the experimental values and assess the contribution of gamma noise. Preliminary implantation tests on anaesthetized rats proved PIXSIC's functionality in brain tissue. High spatial resolution allows for the visualization of radiotracer concentration in different brain regions with high temporal resolution.
An exciting challenge for neuro-physiological investigations remains the combination of brain imaging and behavioral studies, which associates molecular processes of neuronal communications to their related actions. PIXSIC presents novel strategy using a submillimeter pixellated probe for β+ radiotracer detection based on a reverse-biased, high-resistivity silicon diode; This fully autonomous detection system permits local, time resolved measurements of radiotracers in a volume of a few mm3 with the probe dipped into aqueous solutions of [18F] and [11C]. Preliminary implantation tests on a anaesthetized rats proved functionality of the PIXSIC probe in brain tissues. High spatial resolution allows for the visualization of radiotracer concentration in different brain regions with a temporal resolution of less than 2 seconds
Positron emission tomography (PET) images suffer from low spatial resolution and signal-to-noise ratio. Accurate modelling of the effects affecting resolution within iterative reconstruction algorithms can improve the trade-off between spatial resolution and signal-to-noise ratio in PET images. In this work, we present an original approach for modelling the resolution loss introduced by physical interactions between and within the crystals of the tomograph and we investigate the impact of such modelling on the quality of the reconstructed images. The proposed model includes two components: modelling of the inter-crystal scattering and penetration (interC) and modelling of the intra-crystal count distribution (intraC). The parameters of the model were obtained using a Monte Carlo simulation of the Philips GEMINI GXL response. Modelling was applied to the raw line-of-response geometric histograms along the four dimensions and introduced in an iterative reconstruction algorithm. The impact of modelling interC, intraC or combined interC and intraC on spatial resolution, contrast recovery and noise was studied using simulated phantoms. The feasibility of modelling interC and intraC in two clinical (18)F-NaF scans was also studied. Measurements on Monte Carlo simulated data showed that, without any crystal interaction modelling, the radial spatial resolution in air varied from 5.3 mm FWHM at the centre of the field-of-view (FOV) to 10 mm at 266 mm from the centre. Resolution was improved with interC modelling (from 4.4 mm in the centre to 9.6 mm at the edge), or with intraC modelling only (from 4.8 mm in the centre to 4.3 mm at the edge), and it became stationary across the FOV (4.2 mm FWHM) when combining interC and intraC modelling. This improvement in resolution yielded significant contrast enhancement, e.g. from 65 to 76% and 55.5 to 68% for a 6.35 mm radius sphere with a 3.5 sphere-to-background activity ratio at 55 and 215 mm from the centre of the FOV, respectively, without introducing additional noise. Patient images confirmed the usefulness of interC and intraC modelling for improving spatial resolution and contrast. Based on Monte Carlo simulated data, we conclude that four-dimensional modelling of the inter- and intra-crystal interactions during the reconstruction process yields a significantly improved contrast to noise ratio and the stationarity of the spatial resolution in the reconstructed images.
GATE (Geant4 Application for Emission Tomography) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. Dedicated to the modelling of planar scintigraphy, single photon emission computed tomography (SPECT) and positron emission tomography (PET) acquisitions, this platform is widely used to assist PET and SPECT research. A recent extension of this platform, released by the OpenGATE collaboration as GATE V6, now also enables modelling of x-ray computed tomography and radiation therapy experiments. This paper presents an overview of the main additions and improvements implemented in GATE since the publication of the initial GATE paper (Jan et al 2004 Phys. Med. Biol. 49 4543-61). This includes new models available in GATE to simulate optical and hadronic processes, novelties in modelling tracer, organ or detector motion, new options for speeding up GATE simulations, examples illustrating the use of GATE V6 in radiotherapy applications and CT simulations, and preliminary results regarding the validation of GATE V6 for radiation therapy applications. Upon completion of extensive validation studies, GATE is expected to become a valuable tool for simulations involving both radiotherapy and imaging.
The charge sharing effect in the single photon counting hybrid pixel detector XPAD3-S is studied. Several figures of merit are measured, both in the case of Si and CdTe sensors. Data are compared to a Monte Carlo simulation that models the main sources of charge migration.
A main challenge in the development of new detectors is the achievement of a satisfactory comprehension of the instrument behaviour. We present the simulation work developed to understand and characterize an innovative micro-CT scanner. The PIXSCAN scanner is a photon counting device based on hybrid pixel detectors. Its working principle is expected to improve the contrast for soft tissues and to reduce both the scan duration and the dose absorbed by the animal. A prototype of the scanner, PIXSCAN-XPAD2, has been assembled and studied in order to achieve a proof of principle of the system. Simulations by analytical and Monte Carlo methods of the prototype and of the evaluation phantoms have been developed to ensure a satisfactory comprehension of the data. The Monte Carlo simulation was based on the GATE package. It included the complete simulation of photon propagation in matter, together with the modelling of the source spectrum, the scanner geometry and the sensor response. The analytical simulation is much more approximate, but its merit is the rapidity which permits fast preliminary results. Several figures of merit are studied and show good agreement with real data. Hence, the developed simulations can be used as a valid tool for the estimation of the ultimate PIXSCAN performances, in terms of spatial resolution, contrast measurement and dose reduction.
In this study, we present a small animal hybrid PET/CT scanner for simultaneous X and gamma ray scans of the same field of view. It is based on the high resolution PET scanner demonstrator ClearPET developed within the Crystal Clear Collaboration and on the prototype X-ray hybrid pixel detector XPAD3 developed at CPPM. The complete hybrid system has been studied using the GATE Monte Carlo simulation platform. The final design includes the PET detectors appropriately shielded, the XPAD3 detector and a collimated RTW X-ray tube. First, we present experimental measurements that demonstrate the feasibility of acquiring PET data in presence of an X-ray beam scattered by a water phantom hosting a positron emitter point source. Then, we present first images of simultaneous PET and CT acquisitions of several phantoms and a mouse.
Irène Buvat合作论文数INSERM U494, CHU Pitié Salpétrière, Paris2