X-ray imaging indicates magnetized liner inertial fusion (MagLIF) stagnation columns have a complicated quasi-helical structure with significant variations in x-ray brightness along the column. In this work, we describe MagLIF experiments aimed at controlling these stagnation structures by varying the initial liner geometry and composition. First, by varying the initial aspect ratio of the liner, we demonstrate a change in the stagnation structures that is consistent with helical magneto Rayleigh–Taylor (MRT) instabilities feedthrough from the outer-to-inner surfaces of the liner. Second, to minimize the seed for such instabilities, we incorporate a dielectric coating on the outer surface of the beryllium liner, which has previously been shown to reduce the growth of the electrothermal instability, a likely seed for MRT growth. Using this coating, we achieve a stagnation column with significantly reduced helical structure and axial variation in x-ray brightness. We discuss how this coating changes the evolution of structures through stagnation along with the spatial uniformity of neutron production. Finally, we show that these more uniform stagnations also result in improved reproducibility in stagnation temperatures and primary DD neutron yield.
We report on a series of Magnetized Liner Inertial Fusion (MagLIF) experiments conducted on the Z pulsed power facility that utilized high aspect ratio (ratio of outer radius to wall thickness) liners with dielectric coatings and low-mix laser preheat configurations. The liners consisted of an aspect ratio of 10.6 beryllium tube coated with 75 μm of epoxy on the outside that have been shown to maintain a better implosion stability than uncoated beryllium and have demonstrated consistent stagnation performances in previous experiments [Ampleford et al., Phys. Plasmas 31, 022703 (2024)]. Two-dimensional HYDRA simulations were used to design three different “co-injection” laser configurations, whereby a second laser is used to provide an early prepulse before the main pulse, to reduce LEH foil mix while increasing the fuel density and coupled energy. The laser preheat energy for each configuration was constrained using dedicated laser experiments before being applied to the integrated MagLIF experiments on Z. The DD neutron yield for experiments using co-injection preheat configurations is found to increase with the specific preheat energy in line with simulations. The highest neutron yield achieved in this study of 1.1 × 1013 matches the highest reported in a MagLIF experiment to date and is a factor 3.5 times higher than similar experiments using preheat with no phase plate smoothing. We attempt to assess the effects of mix and morphology to explain the improved performance; however, neither factor is found to be conclusive within the uncertainty of the measurements.
Pulsed power generators create high-energy-density conditions by rapidly delivering an immense pulse of electrical current to a compact imploding load. Accurately measuring the shape and amplitude of this load current pulse is essential to understanding the behavior of all pulsed power experiments. At the Z Pulsed Power Facility, the closest-in load current measurements are provided by velocimetry techniques such as VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry). Here, fiber-coupled interferometers measure the velocity history of an exploding metallic flyer plate that is embedded in the vertical walls of the current return can. The flyer plate is driven outward by the magnetic pressure from the load current such that magnetohydrodynamic modeling can be used to determine the load current waveform from the measured velocity history. In this paper, we present the first load current velocimetry measurements to be made from the horizontal top flyer plate that carries current radially inward from the return can to the load. These spatially resolved measurements, which span R = 5- 9 mm, are enabled by a transformative new velocimetry diagnostic-a line-imaging velocity interferometer called Z Line VISAR (ZLV)-whose optical performance overcomes the measurement challenges presented by the steep velocity gradients encountered on the top flyer plate. To validate ZLV's capabilities, a 14-MA, 100-ns experiment was conducted to losslessly couple current up the return can and radially inward across the top flyer plate. Comparisons between the ZLV data obtained from this experiment and two-dimensional magnetohydrodynamic simulations driven with the current measured on the return can indicate that the current delivery across the top flyer plate is indeed lossless to within the few-percent uncertainty of the ZLV data. Given that the current coupling is lossless, the experimental results are used to demonstrate that one-dimensional current unfold techniques can be applied to generate a radially resolved load current map from the ZLV velocity data. This analysis provides a template for how to use the ZLV diagnostic to determine the efficacy of current delivery in future experiments where losses may occur in close proximity to the load.
Electrothermal instability plays an important role in applications of current-driven metal, creating striations (which seed the magneto-Rayleigh-Taylor instability) and filaments (which provide a more rapid path to plasma formation). However, the initial formation of both structures is not well understood. Simulations show for the first time how a commonly occurring isolated defect transforms into the larger striation and filament, through a feedback loop connecting current and electrical conductivity. Simulations have been experimentally validated using defect-driven self-emission patterns.
Magnetized liner inertial fusion (MagLIF) is a fusion concept that uses magnetized, preheated fuel to reduce the implosion velocities and convergence ratios required for ignition. A scaled, laser-driven experimental platform to study MagLIF has been demonstrated on the OMEGA laser system, providing comprehensive experimental data on MagLIF scaling, utilizing the higher shot rate on OMEGA compared to the Z machine. Using this platform, a broader experimental space for MagLIF has been studied. Presented in this article are experimental results that demonstrate that the combination of preheat and magnetization enhances the neutron yield by 470% compared to a reference implosion, significantly more than the yield enhancement by the field or preheat alone. These results are achieved while maintaining a relatively low convergence ratio (<20). The experiments were supported by one-, two-, and three-dimensional radiation-hydrodynamics simulations, all of which suggest that multiple sources of mix play different key roles depending on the scale of the MagLIF experiment.
Using three-dimensional (3D) magnetohydrodynamic simulations, we study how a pit on a metal surface evolves when driven by intense electrical current density j. Redistribution of j around the pit initiates a feedback loop: j both reacts to and alters the electrical conductivity σ, through Joule heating and hydrodynamic expansion, so that j and σ are constantly in flux. Thus, the pit transforms into larger striation and filament structures predicted by the electrothermal instability theory. Both structures are important in applications of current-driven metal: The striation constitutes a density perturbation that can seed the magneto-Rayleigh-Taylor instability, while the filament provides a more rapid path to plasma formation, through 3D j redistribution. Simulations predict distinctive self-emission patterns, thus allowing for experimental observation and comparison.
We present an overview of the magneto-inertial fusion (MIF) concept Magnetized Liner Inertial Fusion (MagLIF) pursued at Sandia National Laboratories and review some of the most prominent results since the initial experiments in 2013. In MagLIF, a centimeter-scale beryllium tube or ‘liner’ is filled with a fusion fuel, axially pre-magnetized, laser pre-heated, and finally imploded using up to 20 MA from the Z machine. All of these elements are necessary to generate a thermonuclear plasma: laser preheating raises the initial temperature of the fuel, the electrical current implodes the liner and quasi-adiabatically compresses the fuel via the Lorentz force, and the axial magnetic field limits thermal conduction from the hot plasma to the cold liner walls during the implosion. MagLIF is the first MIF concept to demonstrate fusion relevant temperatures, significant fusion production (>1013 primary DD neutron yield), and magnetic trapping of charged fusion particles. On a 60 MA next-generation pulsed-power machine, two-dimensional simulations suggest that MagLIF has the potential to generate multi-MJ yields with significant self-heating, a long-term goal of the US Stockpile Stewardship Program. At currents exceeding 65 MA, the high gains required for fusion energy could be achievable.
The magneto-Rayleigh-Taylor instability (MRTI) plays an essential role in astrophysical systems and in magneto-inertial fusion, where it is known to be an important degradation mechanism of confinement and target performance. In this Letter, we show for the first time experimental evidence of mode mixing and the onset of an inverse-cascade process resulting from the nonlinear coupling of two discrete preseeded axial modes (400- and 550-μm wavelengths) on an Al liner that is magnetically imploded using the 20-MA, 100-ns rise-time Z Machine at Sandia National Laboratories. Four radiographs captured the temporal evolution of the MRTI. We introduce a novel unfold technique to analyze the experimental radiographs and compare the results to simulations and to a weakly nonlinear model. We find good quantitative agreement with simulations using the radiation magnetohydrodynamics code hydra. Spectral analysis of the MRTI time evolution obtained from the simulations shows evidence of harmonic generation, mode coupling, and the onset of an inverse-cascade process. The experiments provide a benchmark for future work on the MRTI and motivate the development of new analytical theories to better understand this instability.
The Sandia Z facility has the world’s largest pulsed power machine and includes the multi-kJ Z-Beamlet laser. Z has been used for inertial confinement fusion research for over 25 years, in addition to supporting other high energy density science [1] . Until 2006, wire array z-pinches were used to produce the highest soft x-ray power and total x-ray energy of any laboratory facility at the time using two differet indirectdrive fusion concepts. These remain of future interest, but the largest uncertainty in scaling is the capsule physics that is best addressed using the National Ignition Facility. Today, research on Z is studying the use of magnetic pressure to directly compress solid liners containing fusion fuel [2] , such as the Magnetized Liner Inertial Fusion (MagLIF) concept that demonstrated the fundamental principles of magnetoinertial fusion in the laboratory [3] .
The “Decel” platform at Sandia National Laboratories investigates the Richtmyer–Meshkov instability (RMI) in converging geometry under high energy density conditions [Knapp et al., Phys. Plasmas 27, 092707 (2020)]. In Decel, the Z machine magnetically implodes a cylindrical beryllium liner filled with liquid deuterium, launching a converging shock toward an on-axis beryllium rod machined with sinusoidal perturbations. The passage of the shock deposits vorticity along the Be/D2 interface, causing the perturbations to grow. In this paper, we present platform improvements along with recent experimental results. To improve the stability of the imploding liner to the magneto Rayleigh–Taylor instability, we modified its acceleration history by shortening the Z electrical current pulse. Next, we introduce a “split rod” configuration that allows two axial modes to be fielded simultaneously in different axial locations along the rod, doubling our data per experiment. We then demonstrate that asymmetric slots in the return current structure modify the magnetic drive pressure on the surface of the liner, advancing the evolution on one side of the rod by multiple ns compared to its 180° counterpart. This effectively enables two snapshots of the instability at different stages of evolution per radiograph with small deviations of the cross-sectional profile of the rod from the circular. Using this platform, we acquired RMI data at 272 and 157 μm wavelengths during the single shock stage. Finally, we demonstrate the utility of these data for benchmarking simulations by comparing calculations using ALEGRA MHD and RageRunner.
We present a new analysis methodology that allows for the self-consistent integration of multiple diagnostics including nuclear measurements, x-ray imaging, and x-ray power detectors to determine the primary stagnation parameters, such as temperature, pressure, stagnation volume, and mix fraction in magnetized liner inertial fusion (MagLIF) experiments. The analysis uses a simplified model of the stagnation plasma in conjunction with a Bayesian inference framework to determine the most probable configuration that describes the experimental observations while simultaneously revealing the principal uncertainties in the analysis. We validate the approach by using a range of tests including analytic and three-dimensional MHD models. An ensemble of MagLIF experiments is analyzed, and the generalized Lawson criterion χ is estimated for all experiments.