The National Institute of Justice strives to assist criminal justice practitioners through research, development, and evaluation of technologies and methods. RAND researchers interviewed an extensive sample group to assess priorities at the state and local levels, the means by which those agencies commonly receive information on technology, and the effectiveness of outreach by the National Law Enforcement and Corrections Technology Center
PURPOSE:To characterize the interfractional variability in lung tumor volume, position, and tumor boundaries.METHODS:Cone-beam computed tomography (CBCT) scans were acquired weekly during the course of treatment for 34 lung cancer patients (1-20 scans) with large tumors. Spatial registration based on bones was performed between contoured planning CT and CBCT. Gross tumor volume (GTV) on each CBCT was then contoured. Tumor volume, centroid, and boundaries variability were quantified. A commercial deformable registration software was tested and results were compared to manual contours.RESULTS:Mean volume reduction was 41 ± 32% (p < 0.001) after an average time of 51 days. Tumor centroid drifts were 0.03, 0.14, and -0.13 cm in right-left (RL), anterior-posterior (AP), and superior-inferior (SI) directions with standard deviations of 0.55, 0.50, and 0.51 cm. GTV boundaries displacements were -0.27, -0.14, and -0.16 cm with standard deviations of 0.64, 0.57, and 0.59 cm in RL, AP, and SI directions. Relative error between deformed and manual contours with the commercial deformable registration software rose up exponentially with the GTV decrease.CONCLUSIONS:GTV size changes for large lung tumors are similar to those for standard tumors. Magnitude absolute values of displacement vector for centroid and boundaries shifts show that there is not a preferred direction for the drifts but shrinkage.
PURPOSE:To implement SPECT-based optimization in an anatomy-based aperture inverse planning system for the functional avoidance of lung in thoracic irradiation.MATERIAL AND METHODS:SPECT information has been introduced as a voxel-by-voxel modulation of lung importance factors proportionally to the local perfusion count. Fifteen cases of lung cancer have been retrospectively analyzed by generating angle-optimized non-coplanar plans, comparing a purely anatomical approach and our functional approach. Planning target volume coverage and lung sparing have been compared. Statistical significance was assessed by a Wilcoxon matched pairs test.RESULTS:For similar target coverage, perfusion-weighted volume receiving 10 Gy was reduced by a median of 2.2% (p=0.022) and mean perfusion-weighted lung dose, by a median of 0.9 Gy (p=0.001). A separate analysis of patients with localized or non-uniform hypoperfusion could not show which would benefit more from SPECT-based treatment planning. Redirection of dose sometimes created overdosage regions in the target volume. Plans consisted of a similar number of segments and monitor units.CONCLUSIONS:Angle optimization and SPECT-based modulation of importance factors allowed for functional avoidance of the lung while preserving target coverage. The technique could be also applied to implement PET-based modulation inside the target volume, leading to a safer dose escalation.
Optimal choice of beam energy in radiation therapy is easy in many well‐documented cases, but less obvious in some others. Low‐energy beams may provide better conformity around the target than their high‐energy counterparts due to reduced lateral scatter, but they also contribute to overdosage of peripheral normal tissue. Beam energy was added as an optimization parameter in an automatic aperture‐based inverse planning system. We have investigated a total of six cases for two sites (prostate and lung), representative of deep‐seated and moderately deep‐seated tumors. For one case for each site, different numbers of beam incidences were considered. The other cases for each site were optimized using a fixed number of incidences. Four types of plans were optimized: 6 MV, 23 MV, and mixed energy plans with one or two energies per incidence. Each plan was scored with a dose‐volume cost function. Cost function values, number of segments, monitor units, dose‐volume parameters, and isodose distributions were compared. For the prostate and lung cases, energy mixing improved plans in terms of cost function values, with a more important reduction for a small number of beam incidences. Use of high energy allowed better peripheral tissue sparing, while keeping similar target coverage and sensitive structures avoidance. Low energy contribution to monitor units usually increased with the number of beam incidences. Thus, for deep‐seated and moderately deep‐seated tumors, energy optimization can produce interesting plans with less peripheral dose and monitor units than for low energy alone.PACS numbers: 87.55.de, 87.55.dk, 87.56.N‐
PURPOSE:To verify the potential of aperture-based intensity-modulated radiotherapy (AB-IMRT) to realize dose escalation plans for non-preselected non-small-cell lung cancer (NSCLC) patients, using photon beam energy optimization. METHODS AND MATERIALS:Seven cases of NSCLC were retrospectively studied. Clinical reference plans were made at 60 Gy by an experienced dosimetrist. Dose escalation was applied to PTV2, a subvolume within the main PTV1. Escalation plans were optimized by considering beam angles (table and gantry), energy (6 and 23 MV) and weights, for an increasing dose to the PTV2, starting from 66 Gy and keeping 30 fractions. RESULTS:In five cases, doses over 78 Gy could be achieved before exceeding organs at risk (OARs) standard tolerance. Peripheral overdosages, as well as lung and spinal cord tolerance doses, limited escalation. Means+/-SD V(95%) parameters were (97.3+/-0.9)% for PTV1s and (96.7+/-2.2)% for PTV2s. Doses to OARs were also maintained at acceptable levels. Optimized plans made use of both low- and high-energy beams and had a similar number of monitor units compared to the 60 Gy clinical plans. CONCLUSIONS:The AB-IMRT system can successfully realize dose escalation for a sizeable number of cases. Plans produced contained few large segments, and are applicable to a wide range of tumor volumes and locations.
Inverse planning in external beam radiotherapy often requires a scalar objective function that incorporates importance factors to mimic the planner's preferences between conflicting objectives. Defining those importance factors is not straightforward, and frequently leads to an iterative process in which the importance factors become variables of the optimization problem. In order to avoid this drawback of inverse planning, optimization using algorithms more suited to multiobjective optimization, such as evolutionary algorithms, has been suggested. However, much inverse planning software, including one based on simulated annealing developed at our institution, does not include multiobjective-oriented algorithms. This work investigates the performance of a modified simulated annealing algorithm used to drive aperture-based intensity-modulated radiotherapy inverse planning software in a multiobjective optimization framework. For a few test cases involving gastric cancer patients, the use of this new algorithm leads to an increase in optimization speed of a little more than a factor of 2 over a conventional simulated annealing algorithm, while giving a close approximation of the solutions produced by a standard simulated annealing. A simple graphical user interface designed to facilitate the decision-making process that follows an optimization is also presented.
To automatically determine seed and needle numbers and dispositions within the target volume to achieve optimized dose distribution of tramperineal "'1 permanent implants.
Purpose: Treatment planning of ultrasound-guided transperineal 125I permanent prostatic implants is a timeconsuming task, due to the large number of seeds used and the very large number of possible source arrangements with the target volume. The goal of this work is to develop an algorithm based on fast simulated annealing allowing consistent and automatic dose distribution optimization in permanent 125I prostatic implants.