AIMS:Hypertrophic cardiomyopathy (HCM) is the most common inherited heart disease. Insertable cardiac monitors (ICMs) are increasingly used in this population to provide closer monitoring, with the potential for notification systems. However, little is known regarding the psychological impact this information may have on patients. The Abbott Confirm Rx™ ICM has the capability of connecting to the patient's smartphone to enable active participation in their care, as well as two-way communication between the patient and their care providers. This study aimed to explore individuals' experiences of having a smartphone-enabled ICM to monitor for arrhythmias in HCM. METHODS AND RESULTS:Semi-structured interviews were conducted with 10 participants. Utilizing a grounded theory approach, the interview guide was modified based on emerging themes throughout the study. Reflexive thematic analysis was applied to categorize interview data into codes and overacting themes, with each interview independently coded by two study members. Analysis revealed three key themes: (i) psychological impact, (ii) educational needs, and (iii) technology expectations. Participants reported that receiving feedback from ICM transmissions resulted in improved symptom clarity, providing reassurance, and aiding implantable cardioverter defibrillator decision-making. Some participants reported uncertainty regarding when to send manual transmissions. Lastly, participants reported the app interface did not meet expectations with regard to the amount of data available for patients. CONCLUSION:Overall, utilizing a smartphone app to facilitate two-way communication of ICM transmissions was well accepted. Future directions include addressing gaps in educational needs and improvements in the patient interface with increased access to data.
A trial fibrillation (AF) occurs in 22% to 32% of patients with hypertrophic cardiomyopathy (HCM), 1,2 with ≈50% experiencing subclinical/ asymptomatic AF on cardiac rhythm monitoring devices, including implantable loop recorders, implantable cardioverter- defibrillators (ICDs), and permanent pacemakers. 3 Nonsustained ventricular tachycardia (NSVT) is associated with a higher risk of sudden cardiac death in patients with HCM. 4 Faster, longer, and repetitive episodes of NSVT may confer greater risk. 5 Current guidelines do not directly address the role of different arrhythmia screening strategies (screening frequency, role of extended monitoring, wearable devices) and optimal management of de-tected arrhythmias. We conducted an international multicenter survey to evaluate practice patterns and expert opinions regarding AF and NSVT screening and management at HCM comprehensive care centers. 1 electrophysiology The
Background:Sudden cardiac death (SCD) risk stratification in hypertrophic cardiomyopathy (HCM) currently relies on arrhythmic burden quantification by 24 or 48-hour Holter monitoring. Whether this approach adequately captures arrhythmic burden, compared with longer-term continuous monitoring, is unclear. We sought to assess the long-term incidence of nonsustained ventricular tachycardia (NSVT) in HCM patients at low or moderate SCD risk, using implantable cardiac monitors (ICMs) paired with a novel Bluetooth-enabled 2-way communication platform.Methods:This prospective, single-arm, observational study enrolled 33 HCM patients. Patients were implanted with an Abbott (Chicago, IL) Confirm Rx ICM and monitored using a protocolized care pathway.Results:A total of 20 patients (60.6%) had ≥ 1 episode of NSVT recorded on the ICM, the majority of whom had previous Holter monitors that did not identify NSVT (60%, n = 12). A total of 71 episodes of NSVT were detected. Median time to first NSVT detection was 76.5 days (range: 0-553 days). A total of 19 patients underwent primary prevention implantable cardioverter defibrillator implantation during an average follow-up of 544 days (range: 42-925 days). A total of 172,112 automatic transmissions were received, and 65 (0.04%) required clinical follow-up. A total of 325 manual transmissions were received and managed. A total of 14 manual transmissions (4.3%) required follow-up, whereas 311 (95.7%) were managed solely with a text message.Conclusions:Surveillance and reporting systems utilizing 2-way communication enabled by novel ICMs are feasible and allow remote management of patients with HCM. Prolonged monitoring with ICMs identified more patients with nonsustained arrythmias than did standard Holter monitoring. In many cases, this information impacted both SCD risk stratification and patient management.
Hypertrophic cardiomyopathy (HCM) is the most common inherited cardiomyopathy, presenting significant clinical heterogeneity. Arrhythmia risk stratification and detection are critical components in the evaluation and management of all cases of HCM. The 2020 American Heart Association/American College of Cardiology HCM guidelines provide new recommendations for periodic 24-48-hour ambulatory electrocardiogram monitoring to screen for atrial and ventricular arrhythmias. A strategy of more frequent or prolonged monitoring would lead to earlier arrhythmia recognition and the potential for appropriate treatment. However, whether such a strategy in patients with HCM results in improved outcomes is not yet established. The available evidence, knowledge gaps, and potential merits of such an approach are reviewed. Cardiac implantable electronic devices provide an opportunity for early arrhythmia detection, with the potential to enable early management strategies in order to improve outcomes.