A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. This paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.
Segmented Adaptive-Gap in-Vacuum Undulator (SAGU) prototype with different period lengths and gaps in segments for production of high flux and brightness hard X-rays is under development at NSLS-II. According to radiation flux and brightness calculation results, SAGU promises a significant spectral performance gain compared to a conventional in-vacuum undulator, especially in hard X-ray range. In order to reduce the cost of the project, three existing mechanical carriages of Mini-Gap Undulators from the former NSLS X-ray ring were partially de-assembled, redesigned and optimized in order to meet the required mechanical performance of the device. The magnetic module assembly of the first segment has been carried out using a sorting technique which progressively optimizes the magnetic field quality of the device. Additional magnetic tuning, using small dipole kick magnets and virtual shimming, is planned to further improve the electron trajectory straightness, in particular to compensate the angular kicks experienced by the electron beam at segment junctions as it travels through the device. This paper will describe the magnetic and mechanical design as well as the field measurement results, and the magnetic adjustment implemented to properly tune the field strength and minimize the total field integral produced by the segments.
A 3.0 m long In-Vacuum Undulator (IVU) is employed at the National Synchrotron Light Source II (NSLS-II) for the Hard X-ray Nanoprobe (HXN) beamline providing structural and X-ray fluorescence imaging with world-leading spatial resolution. On July 1st 2018 a gearbox shaft in the gap drive train assembly sheared due to corrosion fatigue caused by stress due to mechanical misalignment. The device was extracted from the storage ring and measured. The magnetic field measurements detected a degradation of the magnetic performance as well as a localized demagnetization of the magnetic modules of the first 3 upstream periods. This paper describes the mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.
The SST-EPU60 is a pure permanent magnet Elliptically Polarized Undulator (EPU) APPLE-II* type developed at Advanced Design Consulting (ADC) for the Synchrotron Radiation Center at University of Wisconsin–Madison [1]. This device was selected to be reused for the Spectroscopy Soft and Tender (SST) beamline at the National Synchrotron Light Source II (NSLS-II). However, due to the more stringent performance requirements of the NSLS-II storage ring, magnetic field tuning was necessary to achieve required specification. This paper reports the details of the SST-EPU60 refurbishment activities including the additional magnetic field measurements and the final results of the magnetic adjustment.
The Soft Inelastic X-ray scattering (SIX) and the Electron-Spectro-Microscopy (ESM) are two beamlines under construction at National Synchrotron Light Source-II (NSLS-II). The specifics of these two beamlines required the use of two long Advanced Planar Polarized Light Emitter-II (APPLE-II) undulators, as a source that provides both circularly and vertically polarized radiation. Thus, we designed 3.5 m and 2.7m long APPLE-II type undulators for SIX and ESM. The NSLS-II ID group is responsible for the magnetic optimization of these two long undulators. In this paper, we first summarize the APPLE-II magnetic and mechanical design. Then, we discuss the magnetic performance of the first APPLE-II achieved with the shimming performed at BNL.
The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring, the transition region was redesigned. The control system was also updated to NSLS-II specifications. This paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.
The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed. We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.
The National Synchrotron Light Source-II (NSLS-II) project is now in the final stage of construction. The Linac, the Booster synchrotron, and the Storage Ring magnets girder assemblies have been installed. The first damping wiggler has been delivered and its field characteristics are carefully measured. A Three Pole Wiggler (3PW) and Apple-II type elliptically polarizing undulators (EPUs) have been fabricated by the vendors. Two 3.0m long in-vacuum undulators (IVUs) and one 1.5m long IVU are almost complete and waiting for factory acceptance tests. One 3.0m long IVU for Inelastic X-ray Scattering beamline is in fabrication by a different vendor. Recently two 2.8m long IVUs for long straight sections (LSSs) have been added to the project for "future beamlines". In addition, two 1.5m long IVUs and one 2.8m long IVU for LSSs have been procured for Advanced Beamlines for Biological Investigations with X-rays (ABBIX) project funded by National Institure of Health (NIH). Further, two 3.5m long EPUs for LSSs are being designed for NSLS-II Experimental Tools (NEXT) -Major Item of Equipment (MIE) project. To succeed these conventional IVUs, PrFeB based cryo-permanent magnet undulator (CPMU) is considered as next generation device of hard X-ray sources. An In-Vacuum Magnetic Measurement System (IVMMS) for cold in-situ Hall probe mapping of CPMUs up to 1.5m in length has been developed. Summary of the current status of each project and future plans for the NSLS-II ring will be discussed.
As the length of insertion devices (ID’s) increase for synchrotron light sources, so does the need to have larger ultra high vacuum (UHV) sealed chambers, which in turn necessitates the use of creative ways of sealing these large chambers in the UHV range (10 -11 torrs).The method specified below was used to seal a 4-meter test vacuum chamber successfully in the ultra high vacuum range. This method could be used for sealing ID chambers of lengths larger than 4 meters in the UHV range due to its simplicity and reduced cost advantage. This test chamber was also baked for 3 cycles to check for the integrity of the seals and final vacuum levels.
Both in-vacuum undulators (IVUs) and cryogenic permanent magnet undulators (CPMUs), each important to third-generation light sources, are best characterized in their operating environment. To create a precision Hall probe map of an IVU/CPMU (IVU hereafter), an in-vacuum magnetic measurement (IVMM) system is proposed. Point-by-point measurement of field and trajectory error informs corrective tuning.A novel design concept for a universal IVMM System has been developed and explored. The IVMM seals to the rectangular Ultra High Vacuum (UHV) flange of the IVU and shares its common vacuum space. Moreover, a modular design permits a wide range of IVUs of varying magnetic length to be mapped with a single IVMM, and is thus cost effective when multiple IVUs of varying configurations are planned. Here we review aspects of the modular IVMM design concept.
Short period (14.5mm) hybrid undulator arrays composed of Praseodymium Iron Boron (Pr2Fe14B) magnets (CR53, NEOMAX, Inc.) and vanadium permendur poles have been fabricated at Brookhaven National Laboratory. Unlike Neodymium Iron Boron (Nd2Fe14B) magnets which exhibit spin reorientation at a temperatures below 150K, PrFeB arrays monotonically increase performance with lower operating temperature. It opens up the possibility for use in operating a cryo-permanent magnet undulator (CPMU) in the range of 40K to 60K where very efficient cryocoolers are available. Magnetic flux density profiles were measured at various temperature ranges from room temperature down to liquid helium (LHe) using the Vertical Testing Facility (VTF) at the National Synchrotron Light Source-II (NSLS-II). Temperature variations of phase error have been characterized. In addition, we examined the use of textured Dysprosium (Dy) poles to replace permendur poles to obtain further improvement in performance.
We report the first experimental characterization of efficiency and spectrum enhancement in a laser-seeded free-electron laser using a tapered undulator. Output and spectra in the fundamental and third harmonic were measured versus distance for uniform and tapered undulators. With a 4% field taper over 3 m, a 300% (50%) increase in the fundamental (third harmonic) output was observed. A significant improvement in the spectra with the elimination of sidebands was observed using a tapered undulator. The experiment is in good agreement with predictions using the MEDUSA simulation code.
The experimental observation of FEL efficiency enhancement using a tapered undulator in a single-pass seeded FEL at the NSLS SDL is reported. The last 2.5 m of the 10 m NISUS undulator was linearly tapered so that the magnetic field strength at the end of the undulator was reduced by 5%. The FEL energy gain along the undulator was measured for both the tapered and un-tapered undulators. We observed that the FEL efficiency was more than doubled by applying the taper. The experimental results are compared with the numerical simulation code,GENE- SIS1.3 [1].
One of the challenges of small-gap superconducting undulators is measurement of magnetic fields within the cold bore to characterize the device performance and to determine magnetic field errors for correction or shimming, as is done for room-temperature undulators. Both detailed field maps and integrated field measurements are required. This paper describes a 6-element, cryogenic Hall probe field mapper for the NSLS superconducting undulator Vertical Test Facility (VTF) [1]. The probe is designed to work in an aperture only 3 mm high. A pulsed-wire insert is also being developed, for visualization of the trajectory, for locating steering errors and for determining integrated multi-pole errors. The pulsed-wire insert is interchangeable with the Hall probe mapper. The VTF and the magnetic measurement systems can accommodate undulators up to 0.4 m in length.