Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.
mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.
The National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Lab (BNL) is a third-generation medium-energy storage ring with 3 GeV and sub-nm-rad horizontal emittance, equipped with a top-off capability of 500 mA. It is designed to deliver an extremely intense photon beam across a wide spectral range, from the far-infrared to the very hard X-ray region. This outstanding performance is achieved through a combination of bending magnets (BM), three-pole wigglers (3 PW), and advanced insertion device (ID) sources. Six three-pole wigglers have been constructed at the NSLS-II IDs Lab. These devices are used to produce broadband radiation with lower angular power density and to monitor the electron beam emittance and energy spread. This paper describes the R&D activities focused on developing the required magnetic and mechanical designs, along with magnetic field optimization and the final magnetic measurement results. It also covers the spectral brightness, flux, power density, spatial and angular output properties of the 3 PWs, including their commissioning results and their effects on the performance of the NSLS-II storage ring.
The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. This paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.
Insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator's magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. This fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.
This paper presents the results of an analysis focused on the behavior of emittance, energy spread and radiated power, as well as their variations in relation to the complement of active insertion devices in National Synchrotron Light Source II (NSLS-II) operations. The spectra of radiated power of the installed insertion devices and analytic values of the emittance are compared to that measured by the NSLS-II online diagnostics. A conceptual design of a compensation wiggler that will maintain a constant emittance or energy spread is investigated for NSLS-II and a potential low emittance upgrade scenario.
The focusing property of an ellipsoidal monocapillary has been characterized using the ptychography method with a 405 nm laser beam. The recovered wavefront gives a 12.5×10.4μm2 focus. The reconstructed phase profile of the focused beam can be used to estimate the height error of the capillary surface. The obtained height error shows a Gaussian distribution with a standard deviation of 1.3 μm. This approach can be used as a quantitative tool for evaluating the inner functional surfaces of reflective optics, complementary to conventional metrology methods.
In-vacuum undulators (IVU) [1–7] are used extensively at light source facilities, in particular at medium-energy storage rings, where these devices are the main sources of high-brightness hard X-ra...
The Soft Inelastic X-ray scattering (SIX) and the Electron-Spectro-Microscopy (ESM) are two beamlines under construction at National Synchrotron Light Source-II (NSLS-II). The specifics of these two beamlines required the use of two long Advanced Planar Polarized Light Emitter-II (APPLE-II) undulators, as a source that provides both circularly and vertically polarized radiation. Thus, we designed 3.5 m and 2.7m long APPLE-II type undulators for SIX and ESM. The NSLS-II ID group is responsible for the magnetic optimization of these two long undulators. In this paper, we first summarize the APPLE-II magnetic and mechanical design. Then, we discuss the magnetic performance of the first APPLE-II achieved with the shimming performed at BNL.
The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring, the transition region was redesigned. The control system was also updated to NSLS-II specifications. This paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.
The paper presents an overview of the main functions and new application examples of the "Synchrotron Radiation Workshop" (SRW) code. SRW supports high-accuracy calculations of different types of synchrotron radiation, and simulations of propagation of fully-coherent radiation wavefronts, partially-coherent radiation from a finite-emittance electron beam of a storage ring source, and time-/frequency-dependent radiation pulses of a free-electron laser, through X-ray optical elements of a beamline. An extended library of physical-optics "propagators" for different types of reflective, refractive and diffractive X-ray optics with its typical imperfections, implemented in SRW, enable simulation of practically any X-ray beamline in a modern light source facility. The high accuracy of calculation methods used in SRW allows for multiple applications of this code, not only in the area of development of instruments and beamlines for new light source facilities, but also in areas such as electron beam diagnostics, commissioning and performance benchmarking of insertion devices and individual X-ray optical elements of beamlines. Applications of SRW in these areas, facilitating development and advanced commissioning of beamlines at the National Synchrotron Light Source II (NSLS-II), are described.
National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm. rad, which could be further reduced to 0.5 nm. rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH funded beamlines called "Advanced Beamlines for Biological Investigations with Xrays" (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.
National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy with the horizontal emittance of the electron beam being 0.9 nm.rad. Nine In-Vacuum Undulators (IVUs) are utilized at the NSLS-II as of February 2016. All IVUs have a unique side window derived from the experience from the CHESS facility in Cornell University. An R&D activity called “Vacuum Seal Test” was conducted to ensure the viability of aluminum wire seal. Another R&D activity to develop a measurement system for Cryogenic Permanent Magnet Undulator (CPMU)1) was also performed. Other in-air devices, namely damping wigglers (DWs) and elliptically polarizing undulators (EPUs) utilize extruded aluminum chambers with Non-Evaporable Getter (NEG) coating. The beam-based integral estimates were obtained from the virtual kicks at the upstream and downstream of the undulator that best fit the measured orbit distortion in a model lattice with Tracy. In some cases, there are fairly large discrepancies between magnetic measurement data and observed integrals by the beam. Beam studies were carried out to explain the discrepancies mentioned earlier. The latest experiences on ID development and commissioning are discussed in conjunction with related activities in the world.