The paper reports the first demonstration of in situ laser-induced desorption - quadrupole mass spectrometry (LID-QMS) application on a large scale fusion device performed in summer 2023. LID-QMS allows direct measurements of the fuel inventory of plasma facing components without retrieving them from the fusion device. The diagnostic desorbs the retained gases by heating a 3 mm diameter spot on the wall using a 1 ms long laser pulse and detects them by QMS. Thus, it can measure the gas content at any wall position accessible to the laser. The successful LID-QMS application in laboratory scale and on medium size fusion devices has now been demonstrated on the larger scale and it is already foreseen as tritium monitor diagnostic in ITER. This in situ diagnostic gives direct access to retention physics on a short timescale instead of campaign-integrated measurements and can assess the space-resolvedefficacy of detritation methods. LID-QMS can be applied on many materials: on Be deposits like in JET, B deposits like in TEXTOR, C based materials or on bulk-W.
JET, the world’s largest operating tokamak with unique Be/W wall and tritium handling capability, completed a Deuterium-Tritium (D-T) campaign in 2021 (Maggi et al 29th Fusion Energy Conf. ) following a decade of preparatory experiments, dedicated enhancements, technical rehearsals and training (Horton et al 2016 Fusion Eng. Des. 109–111 925). Operation with tritium raises significant technical, safety and scientific challenges not encountered in standard protium or deuterium operation. This contribution describes the tritium operational requirements, pulses and technical preparations, new operating procedures, lessons learned and details on the achieved operational availability and performance. The preparation and execution of the recent JET tritium experiments benefitted from the previous experience in 1991 (Preliminary Tritium Experiment), 1997 (DTE1 campaign) and 2003 (Trace Tritium Campaigns) and consisted of the following five phases: technical rehearsals and scenario preparation, tritium commissioning, 100% tritium campaign, D-T campaign (DTE2), tritium clean-up. Following the clean-up JET resumed normal operation and is currently undertaking a further D-T campaign (DTE3).
A sequence of fuel recovery methods was tested in JET, equipped with the ITER-like beryllium main chamber wall and tungsten divertor, to reduce the plasma deuterium concentration to less than 1% in preparation for operation with tritium. This was also a key activity with regard to refining the clean-up strategy to be implemented at the end of the 2nd DT campaign in JET (DTE2) and to assess the tools that are envisaged to mitigate the tritium inventory build-up in ITER. The sequence began with 4 days of main chamber baking at 320 °C, followed by a further 4 days in which Ion Cyclotron Wall Conditioning (ICWC) and Glow Discharge Conditioning (GDC) were applied with hydrogen fuelling, still at 320 °C, followed by more ICWC while the vessel cooled gradually from 320 °C to 225 °C on the 4th day. While baking alone is very efficient at recovering fuel from the main chamber, the ICWC and GDC sessions at 320 °C still removed slightly higher amounts of fuel than found previously in isotopic changeover experiments at 200 °C in JET. Finally, GDC and ICWC are found to have similar removal efficiency per unit of discharge energy. The baking week with ICWC and GDC was followed by plasma discharges to remove deposited fuel from the divertor. Raising the inner divertor strike point up to the uppermost accessible point allowed local heating of the surfaces to at least 800 °C for the duration of this discharge configuration (typically 18 s), according to infra-red thermography measurements. In laboratory thermal desorption measurements, maintaining this temperature level for several minutes depletes thick co-deposit samples of fuel. The fuel removal by 14 diverted plasma discharges is analysed, of which 9, for 160 s in total, with raised inner strike point. The initial D content in these discharges started at the low value of 3%–5%, due to the preceding baking and conditioning sequence, and reduced further to 1%, depending on the applied configuration, thus meeting the experimental target.
The new JET ITER-like wall (made of beryllium and tungsten) is more fragile than the former carbon fiber composite wall and requires active protection to prevent excessive heat loads on the plasma facing components (PFC). Analog CCD cameras operating in the near infrared wavelength are used to measure surface temperature of the PFCs. Region of interest (ROI) analysis is performed in real time and the maximum temperature measured in each ROI is sent to the vessel thermal map. The protection of the ITER-like wall system started in October 2011 and has already successfully led to a safe landing of the plasma when hot spots were observed on the Be main chamber PFCs. Divertor protection is more of a challenge due to dust deposits that often generate false hot spots. In this contribution we describe the camera, data capture and real time processing systems. We discuss the calibration strategy for the temperature measurements with cross validation with thermal IR cameras and bi-color pyrometers. Most importantly, we demonstrate that a protection system based on CCD cameras can work and show examples of hot spot detections that stop the plasma pulse. The limits of such a design and the associated constraints on the operations are also presented.
After completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 x 10(19) m(-3), central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.
Recent improvements in software tools and methodology have allowed us to perform a more comprehensive in-vessel calibration for all mid-infrared camera systems at JET. A comparison of experimental methods to calculate the non-uniformity correction is described as well as the linearity for the different camera systems. Measurements of the temperature are assessed for the different diagnostics.
The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.
A new Disruption Mitigation System (DMS) based on Massive Gas Injections (MGI) has been installed at the JET-tokamak. The key component of this system is a fast eddy current driven valve, which is capable of injecting up to 4.6 x 10(-3) MPa m(3) in less than 5 ms. Along with this valve a new gas handling system has been installed, whose control had to be integrated into the JET-operation. The operation of the DMS requires interaction with several other systems. Although Massive Gas Injections are used to ameliorate potentially severe damage to the tokamak plant and plasma facing components caused by disruptions, they introduce a high risk for example to auxiliary heating systems or diagnostics, which could be damaged by high vacuum pressures. In addition to this, the presence of high pressure (of noble and flammable gases) in combination with high voltages represents a risk not only to the actual DMS plant itself (in case of a failure) but also to personnel in the vicinity. These varieties of risks have been addressed and are described in this article. (C) 2015 Elsevier B.V. All rights reserved.
The Joint European Torus (JET) is the largest tokamak currently in operation in the world. One of the greatest challenges of JET is the integrated commissioning of all its major plant systems. This is driven, partially, by the size and complexity of its operational infrastructure and also by the fact that, being an international environment, it has to address the issues of integrating, commissioning and maintaining plant systems developed by third parties.The ITER tokamak, now in construction, is a fusion device twice the size of JET and, being a joint effort between the European Union, China, India, Japan, South Korea, the Russian Federation and the USA, it will share on a wider scale all of the JET challenges regarding integration and integrated commissioning of very large and complex plant systems.With the scope of taking advantage from the history and experience of JET, Fusion for Energy (F4E) has worked together with the Culham Centre for Fusion Energy (CCFE), the host and operator of JET, for the provision of ITER relevant user experiences related to the integrated commissioning of the tokamak. This work presents and discusses the main results and the methods that were used to extract and translate the commissioning experience information into ITER requirements. (C) 2015 Elizabeth A. KensingerElizabeth.kensinger@bc.edu. Published by Elsevier B.V. All rights reserved.
In the recent melt experiments with the JET tungsten divertor, we observe that the heat flux impacting on a leading edge is 3-10 times lower than a geometrical projection would predict. The surface temperature, tungsten vaporisation rate and melt motion measured during these experiments is consistent with the simulations using the MEMOS code, only if one applies the heat flux reduction. This unexpected observation is the result of our efforts to demonstrate that the tungsten lamella was melted by ELM induced transient heat loads only. This paper describes in details the measurements and data analysis method that led us to this strong conclusion. The reason for the reduced heat flux are yet to be clearly established and we provide some ideas to explore. Explaining the physics of this heat flux reduction would allow to understand whether it can be extrapolated to ITER. (C) 2014 Published by Elsevier B.V.
The mirror-linked divertor spectroscopy diagnostic on JET has been upgraded with a new visible and near-infrared grating and filtered spectroscopy system. New capabilities include extended near-infrared coverage up to 1875 nm, capturing the hydrogen Paschen series, as well as a 2 kHz frame rate filtered imaging camera system for fast measurements of impurity (Be II) and deuterium Dα, Dβ, Dγ line emission in the outer divertor. The expanded system provides unique capabilities for studying spatially resolved divertor plasma dynamics at near-ELM resolved timescales as well as a test bed for feasibility assessment of near-infrared spectroscopy.
Arcs are the potentially most dangerous events related to Lower Hybrid (LH) antenna operation. If left uncontrolled they can produce damage and cause plasma disruption by impurity influx. To address this issue an arc real time control and protection imaging system for the Joint European Torus (JET) LH antenna has been implemented. The LH system is one of the additional heating systems at JET. It comprises 24 microwave generators (klystrons, operating at 3.7 GHz) providing up to 5 MW of heating and current drive to the JET plasma. This is done through an antenna composed of an array of waveguides facing the plasma. The protection system presented here is based primarily on an imaging arc detection and real time control system. It has adapted the ITER like wall hotspot protection system using an identical CCD camera and real time image processing unit. A filter has been installed to avoid saturation and spurious system triggers caused by ionization light. The antenna is divided in 24 Regions Of Interest (ROIs) each one corresponding to one klystron. If an arc precursor is detected in a ROI, power is reduced locally with subsequent potential damage and plasma disruption avoided. The power is subsequently reinstated if, during a defined interval of time, arcing is confirmed not to be present by image analysis. This system was successfully commissioned during the restart phase and beginning of the 2013 scientific campaign. Since its installation and commissioning, arcs and related phenomena have been prevented. In this contribution we briefly describe the camera, image processing, and real time control systems. Most importantly, we demonstrate that an LH antenna arc protection system based on CCD camera imaging systems works. Examples of both controlled and uncontrolled LH arc events and their consequences are shown.
As part of the ILW project, new diagnostics have been installed in order to protect the plasma-facing components (PFCs). Here we present the diagnostics used to monitor the PFC temperature, thermocouples and cameras, and assess the consistency of their measurements. In dedicated limited L-mode plasmas, the surface of the limiter tiles are heated up to 900°C. The comparison of surface temperature measurements from IR and near IR cameras, which have been calibrated against a black-body source, leads to a Be emissivity of 0.18, comparable with the theoretical one. Energy calculation derived from thermocouples, which are embedded in both limiters and divertor target plates (W-coated CFC), is compared to a 1D model based on thermal quadrupole approach (benchmarked with an ANSYS model) associated to an inversion computation. The analysis of 20 pulses shows that a good energy balance is achieved within the error bar of the model, assessed to be of 30%.
The use of programmable logic controllers (PLC) for automation of electromechanical processes is an industrial control system technology. It is more and more in use within the fusion community. Traditionally PLC based systems are operated and maintained using proprietary SCADA systems (supervisory control and data acquisition). They are hardly ever integrated with the fusion control and data acquisition systems.An overview of the state of the art in fusion is given in the article.At JET an inhouse "black box protocol" approach has been developed to communicate with any external system via a dedicated http based protocol. However, a PLC usually cannot be modified to implement this special protocol. Hence, a software layer has been developed that interfaces a PLC by implementing the PLC specific communication part on one side and the black box protocol part on the other side. The software is completely data driven i.e. editing the data structure changes the logic accordingly. It can be tested using the web capability of the black box protocol. Multiple PLC types from different vendors are supported, thus multiple protocols to interface the PLC are in use. Depending on the PLC type and available tools it can be necessary to program the PLC accordingly.Wendelstein 7-X uses another approach. For every single PLC a dedicated communication from and to CoDaC is implemented. This communication is projected (programmed) in the PLC and configurable (data driven) on the CoDaC side. The protocol is UDP based and observed via timeout mechanisms. The use of PLCs for Wendelstein 7-X is standardized. Therefore a single implementation on the CoDaC side allows communication with any PLC. Measured data from the PLC is archived in the mass data store. Set points from CoDaC can be visualized from within the PLC visualization environment.A detailed description, discussion and comparison of the JET and W7-X approaches is given. (c) 2012 Published by Elsevier B.V.
For the new ITER-like wall at JET, two new infrared diagnostics (KL9B, KL3B) have been installed. These diagnostics can operate between 3.5 and 5 μm and up to sampling frequencies of ∼20 kHz. KL9B and KL3B image the horizontal and vertical tiles of the divertor. The divertor tiles are tungsten coated carbon fiber composite except the central tile which is bulk tungsten and consists of lamella segments. The thermal emission between lamellae affects the surface temperature measurement and therefore KL9A has been upgraded to achieve a higher spatial resolution (by a factor of 2). A technical description of KL9A, KL9B, and KL3B and cross correlation with a near infrared camera and a two-color pyrometer is presented.