BackgroundIn view of the rising global burden of severe symptomatic aortic stenosis, its early recognition and treatment is key. Although patients with classical low-flow, low-gradient (C-LFLG) aortic stenosis have higher rates of death after transcatheter aortic valve implantation (TAVI) when compared with patients with high-gradient (HG) aortic stenosis, there is conflicting evidence on the death rate in patients with severe paradoxical low-flow, low-gradient (P-LFLG) aortic stenosis. Therefore, we aimed to compare outcomes in real-world patients with severe HG, C-LFLG, and P-LFLG aortic stenosis undergoing TAVI. Methods and ResultsClinical outcomes up to 5 years were addressed in the 3 groups of patients enrolled in the prospective, national, multicenter SwissTAVI registry. A total of 8914 patients undergoing TAVI at 15 heart valve centers in Switzerland were analyzed for the purpose of this study. We observed a significant difference in time to death at 1 year after TAVI, with the lowest observed in HG (8.8%) aortic stenosis, followed by P-LFLG (11.5%; hazard ratio [HR], 1.35 [95% CI, 1.16-1.56]; P<0.001) and C-LFLG (19.8%; HR, 1.93 [95% CI, 1.64-2.26]; P<0.001) aortic stenosis. Cardiovascular death showed similar differences between the groups. At 5 years, the all-cause death rate was 44.4% in HG, 52.1% in P-LFLG (HR, 1.35 [95% CI, 1.23-1.48]; P<0.001), and 62.8% in C-LFLG aortic stenosis (HR, 1.7 [95% CI, 1.54-1.88]; P<0.001). ConclusionsUp to 5 years after TAVI, patients with P-LFLG have higher death rates than patients with HG aortic stenosis but lower death rates than patients with C-LFLG aortic stenosis.
Background: Women with ST-segment elevation myocardial infarction (STEMI) experience greater delays for percutaneous coronary intervention-facilitated reperfusion than men. Whether women and men benefit equally from current strategies to reduce ischaemic time and whether there are gender differences in factors determining delays is unclear. Methods: Patient delay (symptom onset to first medical contact) and system delay (first medical contact to percutaneous coronary intervention-facilitated reperfusion) were compared between women (n=967) and men (n=3393) in a Swiss STEMI treatment network. Trends from 2000 to 2016 were analysed, with additional comparisons between three time periods (2000-2005, 2006-2011 and 2012-2016). Factors predicting delays and hospital mortality were determined by multivariate regression modelling. Results: Female gender was independently associated with greater patient delay (P=0.02 vs. men), accounting for a 12% greater total ischaemic time among women in 2012-2016 (median 215 vs. 192 minutes, P<0.001 vs. men). From 2000-2005 to 2012-2016, median system delay was reduced by 18 and 25 minutes in women and men, respectively (P<0.0001 for trend, P=n.s. for gender difference). Total occlusion of the culprit artery, stent thrombosis, a Killip class of 3 or greater, and presentation during off-hours predicted delays in men, but not in women. A Killip class of 3 or greater and age, but not gender or delays, were independently associated with hospital mortality. Conclusions: STEMI-related ischaemic time in women remains greater than in men due to persistently greater patient delays. In contrast to men, clinical signs of ongoing chest discomfort do not predict delays in women, suggesting that female STEMI patients are less likely to attribute symptoms to a condition requiring urgent treatment.
Aim: To assess the accuracy of multi-detector computed tomography (MDCT) derived pulmonary vessel measurements in predicting pulmonary hypertension (PH) among patients with severe symptomatic aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). Background: PH is common among patients with severe AS undergoing TAVI and is associated with adverse outcomes. MDCT is the imaging modality of choice to assess anatomical dimensions among patients selected for TAVI. Methods: One hundred and thirty-nine patients with severe AS undergoing TAVI with both CT scans and right heart catheterizations (RHC) were included. CT diameters of the main pulmonary artery (MPA), right (RPA) and left (LPA), and ascending aorta (AA) were measured. The relationship between CT measurements and PA pressures assessing using RHC was tested with linear regression. Results: The CT derived ratio of the diameter of the MPA to the diameter of the AA (PA/AAratio) correlated best with mean PA pressure (R-2 = 0.48) and PA systolic pressure (R-2 = 0.50). Receiver operating characteristic curve analysis showed that the PA/AAratio is a moderate predictor of PH (AUC 0.74, 95% CI 0.65-0.83, p < 0.0001) and that the optimal cut off point is 0.80 (sensitivity 56%, specificity 88%, positive predictive value 95.5%, negative predictive value 30.6% for PH). Conclusions: Elderly patients with severe AS and PA/AAratio values >= 0.80 on MDCT are more likely to have PH but PH cannot be reliably excluded among such patients with lower PA/AAratio values.
BACKGROUND:Drug-eluting stents combining an ultrathin cobalt-chromium stent platform with a biodegradable polymer eluting sirolimus have been shown to be non-inferior or superior to thin-strut, durable-polymer, everolimus-eluting stents in terms of 1 year safety and efficacy outcomes. METHODS:In the randomised, single-blind, multicentre, non-inferiority BIOSCIENCE trial, we compared biodegradable-polymer sirolimus-eluting stents with durable-polymer everolimus-eluting stents in patients with chronic stable coronary artery disease or acute coronary syndromes. Here, we assess the final 5-year clinical outcomes of BIOSCIENCE with regards to the primary clinical outcome of target lesion failure, which was a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation. The primary analysis was done by intention to treat. The BIOSCIENCE trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS:2008 (95%) of 2119 patients recruited between March 1, 2012, and May 31, 2013, completed 5 years of follow-up. Target lesion failure occurred in 198 patients (cumulative incidence 20·2%) treated with biodegradable-polymer sirolimus-eluting stents and in 189 patients (18·8%) treated with durable-polymer everolimus-eluting stents (rate ratio [RR] 1·07, 95% CI 0·88-1·31; p=0·487). All-cause mortality was significantly higher in patients treated with biodegradable-polymer sirolimus-eluting stents than in those treated with durable-polymer everolimus-eluting stents (14·1% vs 10·3%; RR 1·36, 95% CI 1·06-1·75; p=0·017), driven by a difference in non-cardiovascular deaths. We observed no difference between groups in cumulative incidence of definite stent thrombosis at 5 years (1·6% in both groups; 1·02, 0·51-2·05; p=0·950). INTERPRETATION:5-year risk of target lesion failure among all-comer patients undergoing percutaneous coronary intervention is similar after implantation of ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents or thin-strut, durable-polymer, everolimus-eluting stents. Higher incidences of all-cause and non-cardiovascular mortality in patients treated with biodegradable-polymer stents eluting sirolimus than in those treated with durable-polymer stents eluting everolimus warrant careful observation in ongoing clinical trials. FUNDING:Clinical Trials Unit of the University of Bern and Biotronik.
Background Early withdrawal of recommended antiplatelet treatment with clopidogrel adversely affects prognosis following percutaneous coronary interventions. Optimal antiplatelet treatment is essential following ST ‐segment elevation myocardial infarction ( STEMI ) given the increased risk of thrombotic complications. This study assessed the frequency, predictors, and clinical impact of early prasugrel cessation in patients with STEMI undergoing primary percutaneous coronary interventions. Methods and Results We pooled patients with STEMI discharged on prasugrel in 2 prospective registries (Bern PCI Registry [ NCT 02241291] and SPUM ‐ ACS (Inflammation and Acute Coronary Syndromes) [ NCT 01000701]) and 1 STEMI trial ( COMFORTABLE ‐ AMI (Comparison of Biomatrix Versus Gazelle in ST‐Elevation Myocardial Infarction) [ NCT 00962416]). Prasugrel treatment status at 1 year was categorized as no cessation; crossover to another P2Y 12 ‐inhibitor; physician‐recommended discontinuation; and disruption because of bleeding, side effects, or patient noncompliance. In time‐dependent analyses, we assessed the impact of prasugrel cessation on the primary end point, a composite of cardiac death, myocardial infarction, and stroke. Of all 1830 included patients (17% women, mean age 59 years), 83% were treated with new‐generation drug‐eluting stents. At 1 year, any prasugrel cessation had occurred in 13.8% of patients including crossover (7.2%), discontinuation (3.7%), and disruption (2.9%). Independent predictors of any prasugrel cessation included female sex, age, and history of cerebrovascular event. The primary end point occurred in 5.2% of patients and was more frequent following disruption (hazard ratio 3.04, 95% confidence interval,1.34–6.91; P =0.008), without significant impact of crossover or discontinuation. Consistent findings were observed for all‐cause death, myocardial infarction, and stent thrombosis following prasugrel disruption. Conclusions In this contemporary study of patients with STEMI , early prasugrel cessation was not uncommon and primarily involved change to another P2Y 12 ‐inhibitor. Disruption was the only type of early prasugrel cessation associated with statistically significant excess in ischemic risk within 1 year following primary percutaneous coronary interventions.
Long-term clinical outcomes of new-generation drug-eluting stents in complex anatomic and clinical settings are not well defined. This study assessed the impact of patient and lesion complexity on 2-year outcomes after coronary revascularization with ultrathin strut biodegradable-polymer (BP) sirolimus-eluting stents (SES) versus durable-polymer (DP) everolimus-eluting stents (EES). In a prespecified analysis of the BIOSCIENCE randomized trial (NCT01443104), complex patients (911 of 2,119; 43%) were defined by the presence of acute ST-elevation myocardial infarction (MI); left ventricular ejection fraction <= 30%; renal dysfunction; insulin-treated diabetes; treatment of ostial lesion, bypass graft, unprotected left main lesion; or 3-vessel intervention. The primary end point was target lesion failure (TLF), a composite of cardiac death, target vessel MI, and clinically indicated target lesion revascularization. At 2.years, complex compared with simple patients had a greater risk of TLF (14.5% vs 7.4%, risk ratio 2.05, 95% confidence interval 1.56 to 2.69; p <0.001). The difference was sustained beyond 1 year on landmark analysis. Complex patients had higher rates of the patient-oriented composite end point of death, any MI, or any revascularization (23% vs 14.4%; p <0.001) as well as definite stent thrombosis (1.6% vs 0.4%, p = 0.006). There were no differences in TLF and patient-oriented composite end point between the BP-SES versus DP-EES, consistently among simple and complex patients. In conclusion, patient and lesion complexity had a durable adverse impact on clinical outcomes throughout 2 years of follow-up in this all-comers randomized trial. Safety and efficacy of new-generation BP-SES and DP-EES were comparable, irrespective of complexity status. (C) 2016 Elsevier Inc. All rights reserved.
Background Rehospitalizations ( RH s) after ST ‐elevation myocardial infarction carry a high economic burden and may deteriorate quality of life. Characterizing patients at higher risk may allow the design of preventive measures. We studied the frequency, reasons, and predictors for unplanned cardiac and noncardiac RH s in ST ‐elevation myocardial infarction patients undergoing primary percutaneous coronary intervention. Methods and Results In this post‐hoc analysis of the COMFORTABLE AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST‐Elevation Myocardial Infarction; NCT00962416) trial including 1137 patients, unplanned cardiac and noncardiac RH s occurred in 133 (11.7%) and in 79 patients (6.9%), respectively, at 1 year. The most frequent reasons for unplanned cardiac RH s were recurrent chest pain without evidence of ischemia (20.4%), recurrent chest pain with ischemia and coronary intervention (16.9%), and ischemic events (16.9%). Unplanned noncardiac RH s occurred most frequently attributed to bleeding (24.5%), infections (14.3%), and cancer (9.1%). On multivariate analysis, left ventricular ejection fraction (22% increase in the rate of RH s per 10% decrease; P =0.03) and angiographic myocardial infarction Syntax score (34% increase per 10‐point increase; P =0.01) were independent predictors of unplanned cardiac RH s. Age emerged as the only independent predictor of unplanned noncardiac RH s. Regional differences for unplanned cardiac RH s were observed. Conclusions Among ST ‐elevation myocardial infarction patients undergoing primary percutaneous coronary intervention in the setting of a randomized, clinical trial, unplanned cardiac RH s occurred in 12% with recurrent chest pain being the foremost reason. Unplanned noncardiac RH s occurred in 7% with bleeding as the leading cause. Left ventricular ejection fraction and Syntax score were independent predictors of unplanned cardiac RH s and identified patient subgroups in need for improved secondary prevention. Clinical Trial Registration URL : http://www.clinicaltrials.gov . Unique identifier: NCT 00962416.
AIMS We sought to assess the performance of drug-eluting stents combining an ultrathin cobalt-chromium platform with a biodegradable polymer across categories of increasing SYNTAX score (SS). METHODS AND RESULTS Patients included in the BIOSCIENCE trial and randomly allocated to treatment with biodegradable polymer sirolimus-eluting stents (BP-SES) or durable polymer everolimus-eluting stents (DP-EES) were categorised according to SS tertiles (low <8, medium 8-15, high >15). The primary endpoint, target lesion failure (TLF), was defined as a composite of cardiac death, target vessel myocardial infarction and clinically indicated target lesion revascularisation. The patient-oriented endpoint (POCE) included death, myocardial infarction, or any repeat revascularisation. The SS was available in 2,041 out of 2,119 patients (96.3%). At two-year follow-up, patients with an SS >15 experienced higher rates of both TLF and POCE as compared to patients with medium and low SS (14.5% vs. 8.1% and vs. 5.9%, p<0.001; 22.7% vs. 14.9% and vs. 12.4%; p<0.001), respectively. Comparable rates of the composite endpoints were documented for both stent types in each category of SS. CONCLUSIONS Increasing lesion complexity as assessed by SS was associated with higher rates of TLF and POCE in a contemporary PCI population with minimal exclusion criteria. BP-SES and DP-EES showed comparable performance across the entire spectrum of CAD severity.
Severe aortic stenosis (AS) and mitral regurgitation (MR) are the two most common valvular lesions referred for surgical intervention in Europe and frequently co-exist. In patients with both severe AS and significant MR referred for surgical aortic valve replacement (SAVR), a concomitant mitral valve intervention is typically performed if the MR is severe, despite the higher associated perioperative risk. The management of moderate MR among SAVR patients is controversial and depends on a number of factors including MR aetiology (i.e., organic versus functional MR), feasibility of repair and patient risk profile. Moderate or severe MR is present in up to one-third of patients undergoing transcatheter aortic valve implantation (TAVI), is mainly of functional aetiology and is typically left untreated. Although data are conflicting, a growing body of evidence suggests that significant MR exerts an adverse effect on both short- and long-term clinical outcomes after TAVI. Moderate or severe MR improves in just over half of patients following TAVI and recent data suggest MR is more likely to improve among patients receiving a balloon-expandable as compared with a self-expandable transcatheter heart valve.
Background: To investigate clinical outcomes of percutaneous coronary intervention using a sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES) compared with a permanent polymer everolimus-eluting stent, Xience (PP-EES) in patients with high risk (ST-segment elevation and non-ST-segment elevation myocardial infarction) acute coronary syndromes (ACS) enrolled in the CENTURY II trial.Methods: CENTURY II is a prospective, multicenter, randomized, single blind, controlled trial comparing BP-SES and PP-EES, with primary endpoint of target lesion failure (TLF) at 9 month post-stent implantation. Out of 1123 patients enrolled in CENTURY II trial, 264 high risk ACS patients were included in this subgroup analysis, and the clinical outcomes including target lesion failure (TLF), target vessel failure (TVF), cardiac death, myocardial infarction, and stent thrombosis were evaluated at 24 months.Results: The baseline clinical, angiographic and procedural characteristics were similar between two groups. At 24 months, TLF occurred in 6.3% of patients receiving a BP-SES and 6.5% of patients receiving a PP-EES (P = 0.95); TVF was 6.3% in patients receiving a BP-SES and 9.4% in patients receiving a PP-EES (P = 0.36). There were no significant differences in cardiac death, myocardial infarction and stent thrombosis rate.Conclusions: BP-SES achieved similar safety and efficacy outcomes as PP-EES in this ACS subgroup of CENTURY II study, at 24-month follow-up. This finding is hypothesis-generating and needs to be confirmed in larger trials with longer follow-up. (C) 2016 Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license
AIMSOur aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial.METHODS AND RESULTSThe BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis.CONCLUSIONSIn this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.
Case reportA 70-year-old caucasian male was admitted for elective aortic valve replacement (AVR) because of severe, symp tom atic aortic stenosis.Preoperative transthoracic echocardiography (TTE) showed a concentric hypertrophic left ventricle with preserved left ventricular ejection fraction (EF 65%) and a severely calcified aortic valve with a maximum pressure gradient (PG) of 82 mm Hg and a mean PG of 52 mm Hg.The preoperative left and right heart catheterisation revealed a mean PG of 54 mm Hg and an aortic valve area (AVA, according to the Gorlin Equation) of 0.74 cm 2 .Preprocedural coronary angio graphy revealed only minor coronary artery disease.The EuroSCORE II was 2.15% and the STS score for mortality was 1.11%.Owing to a Figure 1: Transoesophageal echocardiography views of the prosthetic aortic valve before starting anticoagulation (short axis [A] and long axis [B]).A B Summary Late valve thrombosis is uncommon after trans catheter aortic valve implantation.Herein, we describe such a complication after transcatheter aortic valve implantation of an Edwards SAPIEN XT aortic bioprosthesis valve.
Background: Transradial access (TRA) for coronary angiography (CA) is thought to be superior to the transfemoral approach (TFA) in patients presenting with an acute coronary syndrome (ACS) regarding access site complications and bleeding events.As an institution that primarily uses TFA for CA, we switched to TRA during the year 2012.The aim of this study was to look for differences in bleeding events, procedure times, contrast use in ACS patients and door-to-balloon (dtb) times in STEMI patients comparing the TRA and TFA, respectively.Methods/results: A total of 789 ACS patients underwent CA in 2012.Of these, 502 patients had the TFA and 287 patients the TRA for CA.The overall bleeding rate was 14.1% for TFA and 5.3% for TRA (p <0.01) using the BARC (bleeding academic research consortium) criteria.Access siterelat ed bleeding events were 10.5% in the TFA group and 3.9% in the TRA group (p = 0.01).There were no differences regarding procedure times or contrast use between the two groups.In a multivariate analysis, gender, age, Gp IIb/IIIa use and access site were independent predictors of bleeding events.Of the 789 patients, 428 were STEMI patients.Dtb time was 106 ± 100 minutes (including transfer patients).There was no difference regard ing dtb time between the TRA and the TFA group. Conclusion:For experienced "femoral operators", a switch to the radial access site is feasible and safe.There is no increase in dtb time, fluoroscopy time or contrast use, but a significant decrease in bleeding events with the radial approach in patients presenting with ACS.
Background— Pulmonary hypertension (PH) frequently coexists with severe aortic stenosis, and PH severity has been shown to predict outcomes after transcatheter aortic valve implantation (TAVI). The effect of PH hemodynamic presentation on clinical outcomes after TAVI is unknown. Methods and Results— Of 606 consecutive patients undergoing TAVI, 433 (71.4%) patients with severe aortic stenosis and a preprocedural right heart catheterization were assessed. Patients were dichotomized according to whether PH was present (mean pulmonary artery pressure, ≥25 mm Hg; n=325) or not (n=108). Patients with PH were further dichotomized by left ventricular end-diastolic pressure into postcapillary (left ventricular end-diastolic pressure, >15 mm Hg; n=269) and precapillary groups (left ventricular end-diastolic pressure, ≤15 mm Hg; n=56). Finally, patients with postcapillary PH were divided into isolated (n=220) and combined (n=49) subgroups according to whether the diastolic pressure difference (diastolic pulmonary artery pressure−left ventricular end-diastolic pressure) was normal (<7 mm Hg) or elevated (≥7 mm Hg). Primary end point was mortality at 1 year. PH was present in 325 of 433 (75%) patients and was predominantly postcapillary (n=269/325; 82%). Compared with baseline, systolic pulmonary artery pressure immediately improved after TAVI in patients with postcapillary combined (57.8±14.1 versus 50.4±17.3 mm Hg; P =0.015) but not in those with precapillary (49.0±12.6 versus 51.6±14.3; P =0.36). When compared with no PH, a higher 1-year mortality rate was observed in both precapillary (hazard ratio, 2.30; 95% confidence interval, 1.02–5.22; P =0.046) and combined (hazard ratio, 3.15; 95% confidence interval, 1.43–6.93; P =0.004) but not isolated PH patients ( P =0.11). After adjustment, combined PH remained a strong predictor of 1-year mortality after TAVI (hazard ratio, 3.28; P =0.005). Conclusions— Invasive stratification of PH according to hemodynamic presentation predicts acute response to treatment and 1-year mortality after TAVI.
Background Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bulach, Switzerland) with the durable polymer-based Xience Prime/Xpedition everolimus-eluting stent (EES) (Xience Prime/Xpedition stent, Abbott Vascular, IL) in an all-comers patient population.Design The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer sirolimus-eluting stents (SES) or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least 1 lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary end point target lesion failure (TLF) is a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for noninferiority, inclusion of 2,060 patients would provide more than 80% power to detect noninferiority of the biodegradable polymer SES compared with the durable polymer EES at a 1-sided type I error of 0.05. Clinical follow-up will be continued through 5 years.Conclusion The BIOSCIENCE trial will determine whether the biodegradable polymer SES is noninferior to the durable polymer EES with respect to TLF.
Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent.We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104.Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority &lt;0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014).In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study.Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.