Our purpose was to investigate polymeric gels for use as a highly transparent radiotherapy bolus and determine the relevant physical and dosimetric properties. We first quantified tensile properties (maximum stress, strain, and Young modulus) for various polymeric gels, along with a commercial bolus product in order to illustrate the wide variety of potential materials. For a select polymeric gel with tensile properties similar to currently used radiotherapy bolus, we also evaluated mass and electron density, effective atomic number, optical transparency, and percent depth dose in clinical megavoltage photon and electron beams. For this polymeric gel, mass density was 872 ± 12 and 896 ± 13 g/cm3 when measured via weight/volume and computed tomography Hounsfield units, respectively. Electron density was 2.95 ± 0.04 ×1023 electrons/cm3. Adding fused silica (9% by weight) increases density to that of water. The ratio of the effective atomic number to that of water without and with added silica was 0.780 and 0.835 at 1 MeV, 0.767 and 0.826 at 6 MeV, and 0.746 and 0.809 at 20 MeV. Percent depth dose for 6 MV photons was within 2% of water within the first 2.5 cm and after scaling by the density coincided within 1% out to >7 cm. For 6 and 20 MeV electrons, after scaling for density D80% was within 1.3 and 1.5 mm of water, respectively. The high transparency and mechanical flexibility of polymeric gels indicate potential for use as a radiotherapy bolus; differences in density from water may be managed via either using "water equivalent thickness" or by incorporating fused silica into the material.
Purpose/Objective:While our department is heavily invested in computer-based treatment planning, we historically relied on paper-based charts for management of Radiation Oncology patients. In early 2009, we initiated the process of conversion to an electronic medical record (EMR) eliminating the need for paper charts. Key goals included the ability to readily access information wherever and whenever needed, without compromising safety, treatment quality, confidentiality, or productivity.Methodology: In February, 2009, we formed a multi-disciplinary team of Radiation Oncology physicians, nurses, therapists, administrators, physicists/dosimetrists, and information technology (IT) specialists, along with staff from the Duke Health System IT department. The team identified all existing processes and associated information/reports, established the framework for the EMR system and generated, tested and implemented specific EMR processes.Results:Two broad classes of information were identified: information which must be readily accessed by anyone in the health system versus that used solely within the Radiation Oncology department. Examples of the former are consultation reports, weekly treatment check notes, and treatment summaries; the latter includes treatment plans, daily therapy records, and quality assurance reports. To manage the former, we utilized the enterprise wide system, which required an intensive effort to design and implement procedures to export information from Radiation Oncology into that system. To manage "Radiation Oncology" data, we used our existing system (ARIA, Varian Medical Systems.) The ability to access both systems simultaneously from a single workstation (WS) was essential, requiring new WS and modified software. As of January, 2010, all new treatments were managed solely with an EMR. We find that an EMR makes information more widely accessible and does not compromise patient safety, treatment quality, or confidentiality. However, compared to paper charts, time required by clinicians to access/enter patient information has substantially increased. While productivity is improving with experience, substantial growth will require better integration of the system components, decreased access times, and improved user interfaces. $127K was spent on new hardware and software; elimination of paper yields projected savings of $21 K/year. One year after conversion to an EMR, more than 90% of department staff favored the EMR over the previous paper charts.Conclusion: Successful implementation of a Radiation Oncology EMR required not only the effort and commitment of all functions of the department, but support from senior health system management, corporate IT, and vendors. Realization of the full benefits of an EMR will require experience, faster/better integrated software, and continual improvement in underlying clinical processes.
Purpose: To assess the impact of new technologies on deviation rates in radiation therapy (RT).Methods and Materials: Treatment delivery deviations in RT were prospectively monitored during a time of technology upgrade. In January 2003, our department had three accelerators, none with "modern" technologies (e.g., without multileaf collimators [MLC]). In 2003 to 2004, we upgraded to five new accelerators, four with MLC, and associated advanced capabilities. The deviation rates among patients treated on "high-technology" versus "low-technology" machines (defined as those with vs. without MLC) were compared over time using the two-tailed Fisher's exact test.Results: In 2003, there was no significant difference between the deviation rate in the "high-technology" versus "low-technology" groups (0.16 % vs. 0.11 %,p = 0.45). In 2005 to 2006, the deviation rate for the "high-technology" groups was lower than the "low-technology" (0.083 % vs. 0.21 %,p = 0.009). This difference was caused by a decline in deviations on the "high-technology" machines over time (p = 0.053), as well as an unexpected trend toward an increase in deviations over time on the "low-technology" machines (p = 0.15).Conclusions: Advances in RT delivery systems appear to reduce the rate of treatment deviations. Deviation rates on "high-technology" machines with MLC decline over time, suggesting a learning curve after the introduction of new technologies. Associated with the adoption of "high-technology" was an unexpected increase in the deviation rate with "low-technology" approaches, which may reflect an over-reliance on tools inherent to "high-technology" machines. With the introduction of new technologies, continued diligence is needed to ensure that staff remain proficient with "low-technology" approaches. (c) 2007 Elsevier Inc.